N995CF
Service difficulty reports · 505
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N995CF' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N995CF' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA001041Controller · failedAUTO PRESSURIZATION FAILED SHORTLY AFTER TAKEOFF, DURING MANUAL CONTROL THROUGH FL 290 CABIN CLIMBED UNCONTROLLABLY AT 2000 FPM. DEFERRED PER MEL 21-10 CAT C. DMI CNTL NR C9037012-7913 DUE 8-14-00. PLACARD INSTALLED.SDR RRXA001005Warning Light · illuminatedON CLIMBOUT (APPROX 5,000 FEET) NR 2 ENGINE FIRE WARNING/MASTER CAUTION ILLUMINATION/AURAL WARNING. SHUTDOWN NR 2 ENGINE, DISCHARGED BOTH FIRE BOTTLES.SDR RRXA001003Downlock Switch · inoperativeNR 2 DURING MANUAL EXTENSION CHECKS 0 HYD PRESS. NO NOSE GEAR GREEN LIGHT AND BOTH GEAR NOT LATCHED LT AND GEAR DOOR (RED) LIGHTS STAYED ON. CYCLED GEAR SEVERAL TIMES, NO HELP. RAN EMERGENCY CHECK LIST. RETURNED TO AIRPORT. REMOVED AND REPLACED NLG DOWNLOSDR RRXA002459Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN WELD 3 O CLOCK POSITION INSIDE THRUST REV AFT OF BUCKET, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND EO NR 00SDR RRXA002355Cover · damagedDURING A MAINTENANCE VISIT FOUND TEMPORARY REPAIRS DONE TO THE CROSS SLIDE COVER ON B PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW DOOR COVER IAW DC-8 SRM 51-3-0 AND EO NR 00-04SDR RRXA002351Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PLANK NR 2 STA 233 TO 315, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 5-16SDR RRXA002293Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE MAIN CABIN FLOOR PLANK ROW 8 AT STA 1240 - 1460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APSDR RRXA002250Spoiler Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE NR 3 GROUND SPOILER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NR 3 PANEL IAW DC-8 MM 27-61-1. (CORROSION DAMAGE RECORDED IN EWSDR RRXA002242Spoiler Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE NR 1 GROUND SPOILER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED SPOILER IAW MM 27-61-0. (CORROSION DAMAGE RECORDED IN EWA CORROSSDR RRXA002244Vane · damagedDURING A MAINTENANCE VISIT FOUND SCREW HOLES ELONGATED AND BUSHINGS MISSING ON THE RIGHT WING RIGHT O/B FLAP VANE NR 5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED BUSHING PER EO NR 00-SDR RRXA002194Vane · damagedDURING A MAINTENANCE VISIT FOUND AN ELONGATED BOLT HOLE ON THE RIGHT O/B FLAP VANE NR 6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED BUSHING IAW EO NR 00-047 WITH APPROVED 8110-3 DATED SDR RRXA002639Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 500 - 660 ROW 1 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0SDR RRXA002450Floorboard · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED END TO THE FLOOR PLANK AT STA 800 - 1020, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DASDR RRXA002448Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 800 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH ASDR RRXA002339Seat Track · gougedDURING A MAINTENANCE VISIT FOUND A GOUGED SEAT TRACK AT FUSELAGE STA FS 425 XCW 22.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DAMAGED AREA IAW DC-8 SRM 53-2-3 AND EO NR 00-047 WITH APPROVSDR RRXA002299Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT STA 1250 - 1460 AND XCW 47 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIRED SEAT TRACK IAW DC-8 SRSDR RRXA002200Pin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MLG RETRACT PIN AND PIN BOSS SO MA-AI-3210-01:03 LT MLG RETRACT PIN AND BOSS PIN INSPECTION NEEDED C/W, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8S RM 51-1-8. FABRSDR RRXA002635Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK RT UPPER SKIN AT STA 1460 - 1606, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-SDR RRXA002485Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 3 FLOOR PLANK AT STA 800 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH ASDR RRXA002460Seat Track · damagedDURING A MAINTENANCE VISIT FOUND GOUGED AND ELONGATED HOLES TO THE SEAT TRACK AT FS 925 - 962 XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW PART AND INSTALLED IAW DC-8 SRM 53-2-3, FIG 12, SDR RRXA002452Floorboard · crackedDURING A MAINTENANCE VISIT FOUND HOLES AND CRACKS TO THE FLOORBOARD AT FS 860 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DSDR RRXA002439Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1500 - 1560 XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW EO NR 77-995CF DATED 5-22-00 AND ROSESDR RRXA002438Seat Track · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED SEAT TRACK AT FS 1540 - 1560 XCW 22 LT, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-995CF DATEDSDR RRXA002437Seat Track · misdrilledDURING A MAINTENANCE VISIT FOUND ELONGATED AND MISDRILLED HOLES TO THE SEAT TRACK AT FS 1360 - 1430, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND ESDR RRXA002436Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES ON THE SEAT TRACK AT FS 1060-XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW EA NR 77-995CF DATED 5-22-00 AND ROSENBASDR RRXA002435Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1530 - 1560 XCW 22 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW DC-8 SRM 53-2-0, FIG 12, EA NR 77SDR RRXA002434Seat Track · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE SEAT TRACK AT FS 1380 - 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-995CF SDR RRXA002433Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1300 - 1380 XCW 59.5 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APPROSDR RRXA002432Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1260 - 1380 XCW 22 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-3, FIG 12 ASDR RRXA002431Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 980 - 1125 XCW 57 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 7SDR RRXA002430Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1400 - 1440 XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-9SDR RRXA002429Seat Track · damagedDURING A MAINTENANCE VISIT FOUND GOUGES AND MISDRILLED HOLES IN THE SEAT TRACK AT FS 1220 - 1260, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NSDR RRXA002428Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 822-849 XCW 57 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-9SDR RRXA002427Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 960 - 980 AND XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW DC-8 SRM 53-2-3, FIG 12, 51-1-3SDR RRXA002426Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 883 - XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW DC-8 SRM 51-3-0, ROSENBALM DSDR RRXA002425Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 980 - XCW O, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW ROSENBALM DWG NR 24300 AND EA NR 77-995CF DATED SDR RRXA002424Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 525 - XCW 22.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED TRACK IAW ROSEMBALM DWG NR 24300 AND EO NR 77-995CFSDR RRXA002422Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 460-XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW EO NR 77-995CF DATED 5-22-00 ANSDR RRXA002421Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 690 - 702, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW EA NR 77-995CF, ROSENBALM DWG NR 24SDR RRXA002420Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 440-XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW EA NR 77-995CF, ROSENBALM DRAWING NSDR RRXA002358Skin · dentedDURING A MAINTENANCE VISIT FOUND 2 DENTS BEHIND THE JACK PAD AT STA 280 BETWEEN L36L - L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DENTED AREAS IAW DC-8 EO NR 00-047 WITH APPROVED 8110-SDR RRXA002352Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE FLOOR PLANK AT STA 1240 TO 1460 ROW 10 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8SDR RRXA002301Floorboard · damagedDURING A MAINTENANCE VISIT FOUND HOLES ELONGATED AND CHAFED UNDERSIDE ON NR 5 FLOOR PANEL 320 - 620 ROW 4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH ASDR RRXA002300Floorboard · crackedDURING A MAINTENANCE VISIT FOUND CRACKED OUT FASTENER HOLES TO THE NR 7 FLOOR PANEL 320 - 620 FLOORBEAM ATTACH POINT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK IAW EO NR 00-047 WSDR RRXA002233Scoop · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT FWD W/W DRAIN SCOOP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 51-3-0, 53-2-0 AND EO NR 00-047 WITH APPSDR RRXA002354Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND A HOLE DRILLED VERTICALLY FROM FLOORBEAM ON THE DOUBLER ON INTERCOSTAL AT STA 670 X-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. INSTALLED OVERSIZED FASTENERS AND RSDR RRXA002234Scoop · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT DRAIN SCOOP FWD OF MAIN W/W, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 53-2-0 AND EO NR 00-047SDR RRXA002243Skin · damagedDURING A MAINTENANCE VISIT FOUND COUNTER SINKS FOR ATTACHMENT FASTENERS EXCEED SRM LIMITATIONS ON THE LEFT O/B LEADING EDGE I/B SEGMENT AT XFS 560 - 710, DAMAGE EXCEEDS LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND SDR RRXA002338Bracket · misinstalledDURING A MAINTENANCE VISIT FOUND IMPROPERLY INSTALLED BRACKETS INSTALLED ON THE LEFT I/B FLAP I/B UPPER FLAP VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW VANE IAW EOSDR RRXA002497Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOORBEAM SUPPORT ANGLE FR 1320 X+36 Z-8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-89 SRM 51-1-4, 51-1-21 AND 51-1
Back to N995CF