N995CF

Service difficulty reports · 505

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N995CF' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA002294Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES IN THE FLOOR PANEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002206Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT THE UPPER CARGO COMPT FS 1480, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR STRAPS IAW EO May 16, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002650Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1040 RT ROW 8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002641Floorboard · damagedDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1320 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EOMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002496Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOORBEAM SPLICE AT STA 740 X+20, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 811May 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002490Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANK AT FS 1460 - 1580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002473Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 380 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002471Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 340 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002470Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 320 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW EO NR 00-047 WITH APPROMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002467Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 580 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002464Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 520 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW EO NR 00-047 WITH APPROMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002446Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES IN THE FLOOR PANEL AT STA 420 - 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002368Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 - 1580 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002366Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE FLOOR PANEL AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 81May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002365Floorboard · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE IN 3 PLACES TO THE FLOOR PANEL AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 AND EO NR 0May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002364Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE FLOOR PANEL ROW 7 AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED AND BLENDED HOLES IAW EO NR 00-047 WITH APPROVED 8May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002363Floorboard · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE IN 3 PLACES TO THE FLOOR PANEL ROW 7 AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DAMAGE IAW DC-8 SRM 53-2-0 AND EO NR 00-047 WITMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002362Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 - 1480 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED AND BLENDED HOLES IAW EO NR 00-047 WITH APMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002361Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 TO 1500 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED HOLES IAW EO NR 00-047 WITH APPROVED 8110May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002349Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 960, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH AMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002342Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 700, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DATED May 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002264Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM AT STA 1420 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 ANMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002258Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1360 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-4, 51-1-21 May 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002228Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1240 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-20D AND EO NMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002210Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 640, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED STRAPS/FILLERS AND INSTALLED IAW May 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002205Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT THE UPPER CARGO COMPT FS 1500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS AND FILLERS IAMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002202Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1020 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS/FILLERS IAW EO NR 00-047 WITH AMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002341Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM AT FS 780, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH AMay 13, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002399Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FASTENER HOLE ON THE LT CHIN SCOOP RAM AIR DUCT SKIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH AMay 12, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002395Vane · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED ATTACHMENT HOLES AND T/E OF FLAP SEPARATING AT THE LT FLAP VANE AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW MM 27-51-14.May 12, 2000 · N995CF · Doug DC862 · Trailing Edge FlapsSDR RRXA002388Vane · delaminatedDURING A MAINTENANCE VISIT FOUND ELONGATED AND DELAMINATED HOLES ON THE LEADING OF THE LEFT O/B FLAP VANE NR 6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW MM 27-51-14. (CORROMay 12, 2000 · N995CF · Doug DC862 · Trailing Edge FlapsSDR RRXA002249Vane · delaminatedDURING A MAINTENANCE VISIT FOUND ELONGATED AND DELAMINATED SCREW HOLES ON THE RIGHT O/B FLAP VANE NR 3 ON THE L/E OF THE VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NR 3 FLAP VANE IMay 12, 2000 · N995CF · Doug DC862 · Trailing Edge FlapsSDR RRXA002498Frame · damagedDURING A MAINTENANCE VISIT NEED TO COMPLY WITH MA AM-5310-01:00 EWA FRAME REPAIR AT FS 920 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. C/W MA-AM-5310-01:00 AND RECEIVED AND INSTALLED REPAIR IAAW DC-8 SRM 51May 11, 2000 · N995CF · Doug DC862 · Fuselage Main, FrameSDR RRXA002651Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN THE FLOOR SUPPORT ATTACHED TO FRAME AT STA 380 AND L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110May 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002412Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 360-XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH APPMay 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002409Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 400-XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-20D, 51-1-21 AND EO NR 00-04May 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002408Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 380-XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-4, 51-1-20D, 51-1-21 AND EO May 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002324Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 340 AND XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH May 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002298Floor Support · crackedDURING A MAINTENANCE VISIT FOUND CRACKS IN THE FLOOR SUPPORT AT STA 440 BETWEEN L31R TO L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACKS IAW EO NR 00-047 WITH APPROVED 8110-3 DATMay 10, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002254Link · gougedDURING A MAINTENANCE VISIT FOUND A PORK CHOP GOUGE TO THE LEFT HAND WING O/B FLAP STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RETURNED TO SERVICE IAW EO NR 00-047 WITH APPROVED 8110-3 DATED May 10, 2000 · N995CF · Doug DC862 · Trailing Edge FlapsSDR RRXA0022532Panel · damagedDURING A MAINTENANCE VISIT FOUND HOLES ELONGATED ON THE LT WING T/E LWR HINGED PANEL 577A MOUNT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PANEL IS ACCEPTABLE AND RETURNED TO SERVICE IAW EO NR 00-047 WITH APPMay 10, 2000 · N995CF · Doug DC862 · Wing, Plate/SkinSDR RRXA002245Fitting · chafedDURING A MAINTENANCE VISIT FOUND CHAFING AND A GOUGED T/E ON THE RIGHT I/B FLAP CANOE FITTING AT STA 68, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RETURNED TO SERVICE IAW EO NR 00-047 WITH APPROVEDMay 10, 2000 · N995CF · Doug DC862 · Trailing Edge FlapsSDR RRXA002203Floorbeam · gougedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UPPER CHORD FLOORBEAM AT STA 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED GOUGES SMOOTH IAW EO NR 00-047 WITH APPROVED 8110-3 DATMay 10, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002417Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 500 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-May 9, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002213Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE, DOUBLE DRILLED HOLES, GOUGES AND MISSING NUT PLATES AT VARIOUS PLACES AT STA 225 TO 330 AND L21L TO L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.May 9, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002410Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL AT BOTH ENDS AT STA 1300 TO 1320 AND L4L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-21 AND May 7, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002652Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LONGERON 35L BETWEEN STA 1586 - 1568 LT SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0,May 6, 2000 · N995CF · Doug DC862 · Fuselage Main, Longeron/StringerSDR RRXA002407Keelbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE KEEL BEAM AT STA 815 - 781 AND L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-1-4, May 6, 2000 · N995CF · Doug DC862 · Fuselage Main, KeelSDR RRXA002402Duct · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED AND BLOWN OUT DE-ICE DUCT ON THE RT CHIN SCOOP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-7 ANDMay 6, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002246Spar · crackedDURING A MAINTENANCE VISIT FOUND A 2 INCH CRACK TO THE LWR AUX SPAR ANGLE IN RADIUS OF THE RIGHT T/E REAR AUX SPAR AT XRS 86, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTMay 6, 2000 · N995CF · Doug DC862 · Wing Spar
Back to N995CF