N995CF
Service difficulty reports · 505
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N995CF' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N995CF' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA002323Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE AT STA 1420 LEFT ABOVE L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-8.SDR RRXA002314Web · damagedDURING A MAINTENANCE VISIT FOUND A JAGGED METAL PIECE OF MEMBRANE AT STA 1000 - 1020 AT L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED WEB IAW DC-8 SRM 51-1-21, 51-1-4 ANDSDR RRXA002418Intercostal · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN THE INTERCOSTAL AT FS 560 - 580 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4 AND 51-1-21.SDR RRXA002414Intercostal · damagedDURING A MAINTENANCE VISIT FOUND A CUTOUT WITH NO REPAIR ON THE INTERCOSTAL BETWEEN STA 320 - 340 RT AND RBL 10 INCHES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAWSDR RRXA002310Web · tornDURING A MAINTENANCE VISIT FOUND HOLES TORN OUT BETWEEN STA 560 - 580 XCW 12 INCHES LEFT AT CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW WEB IAW DC-8 SRM 51-1-21 ANDSDR RRXA002303Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RIGHT WING RIGHT O/B LEADING EDGE O/B EDGE UPPER AND LWR SKIN INTERIOR AT XFS 710, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND SDR RRXA002280Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON SKIN LEFT WING O/B LEADING EDGE O/B SECTION AT STA XW 761.695 24 INCHES FWD OF FRONT SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED SDR RRXA002218Finger Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE FINGER DOUBLER COCKPIT SUBFLOOR AT STA 148 TO 144 AND L20L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DSDR RRXA002332Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM TO FRAME ATTACH ANGLE AT STA 1586 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-3-SDR RRXA002316Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND HOLES TO THE INTERCOSTAL AT FS 640 - 660 AND L14R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21, 53-2-0, 51-1-4 ASDR RRXA002315Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND HOLES TO THE INTERCOSTAL AT FS 700 - 717 AND L5R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW INTERCOSTAL IAW DC-8 SRM 51-1-21, 51-1-4 ANSDR RRXA002335Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL AT FS 798 TO 830 AND L5R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 53-2-0, 51-1-4 AND 51-1SDR RRXA002333Longeron · crackedDURING A MAINTENANCE VISIT FOUND A CRACK APPROX 2.5 INCHES LENGTH AT THE RT W/W LONGERON 24 STA 879, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 53-2-3,SDR RRXA002322Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN RADIUS OF SUPPORT ANGLE ON RT BETWEEN STA 920 AND 902 LONGERON 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SDR RRXA002273Intercostal · damagedDURING A MAINTENANCE VISIT FOUND A HOLE TO THE INTERCOSTAL AT FS 340 - 360 AND L5R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAAW DC-8 SRM 51-1-4 AND 51-1-21.SDR RRXA002193Skin · dentedDURING A MAINTENANCE VISIT FOUND THE SKIN DENTED AT RIGHT WING O/B LEADING EDGE AT STA XFS 685, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED RIVETS AND DENT FILLER IAW DC-8 SRM 57-2-1.SDR RRXA002398Finger Doubler · damagedDURING A MAINTENANCE VISIT FOUND A RIVET PULLED THROUGH THE FINGER DOUBLER ON THE LT HORIZ STAB REAR SPAR ACCESS AT STA 221, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED SDR RRXA002330Rivet · looseDURING A MAINTENANCE VISIT FOUND LOOSE RIVETS ON LWR DOOR RETAINERS RT FWD EXIT OPENING OVERWING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-0.SDR RRXA002309Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOOR CHANNEL SUPPORT AT STA 600 XCW 6 INCHES LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-21, 51-1-SDR RRXA002275Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED LWR RIB ON THE LEFT WING O/B LEADING EDGE I/B SEGMENT AT STA 603.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SDR RRXA002271Frame · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN THE FRAME AT FS 320 AND L14R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED GUSSET IAW DC-8 SRM 51-1-21A, 53-2-0, 51-1-4 AND 51-1-21.SDR RRXA002227Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1220 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-20D AND EO SDR RRXA002307Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOORBEAM SUPPORT AT STA 500 XCW 6 INCHES LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-21 AND 51-1-4SDR RRXA002306Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOORBEAM SUPPORT AT STA 500 XCW 6 INCHES RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-21 AND 51-1-4SDR RRXA002217Skin · damagedDURING A MAINTENANCE VISIT FOUND A BROKEN PIECE TOP OF L1 DOOR , DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW DOUBLER IAW DC-8 SRM 51-1-21 AND 51-1-4.SDR RRXA002251Spoiler Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE IN SEVERAL AREAS ON THE NR 4 GROUND SPOILER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PANEL IAW DC-8 SRM 27-61-0. (CORROSION DAMASDR RRXA002215Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BOTTOM RIB ON THE LEFT I/B HORIZ STAB I/B LEADING EDGE FRAME AT XFS 166, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS SDR RRXA002214Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE I/B BOTTOM RIB ON THE LEFT I/B STAB LEADING EDGE FRAME AT XFS 172, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-SDR RRXA002396Bracket · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES ON THE ATTACH ANGLE BRACKET ON THE RT LEADING EDGE CENTER SECTION O/B SLOT DOOR PANEL AT STA XFS 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRSDR RRXA002331Attach Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED ATTACH ANGLE IN THE MAIN CABIN INTERIOR FRAME AT STA 900 AND L11L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SSDR RRXA002327Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE WEB ATTACH FITTING AT FS 1400 AND L21R FRAME TO PRESS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-20D, 5SDR RRXA002394Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 760.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002393Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 772.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002392Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 822.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002391Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 828.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002390Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 847.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM SDR RRXA000114Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM 1380 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000136Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM, AT STA 1140 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000135Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1160 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000134Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1180 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000133Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1200 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000132Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1220 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000131Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1240 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000130Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1260 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000129Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1280 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000128Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1300 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000127Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1320 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000126Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1340 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000125Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1360 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000124Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FLOORBEAM AT STA 1400 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.
Back to N995CF