SDR AALA20001747Wire · reversedDFW - DURING OVERNIGHT MAINTENANCE COACH, EMERGENCY EXIT FLOOR PATH LIGHT HAVE REVERSE POLARITY. CORRECTED POLARITY COACH EMERGENCY EXIT FLOOR PATH LIGHT WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20001411Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FROM ROW 9 TO AFT END OF AIRCRAFT INOPERATIVE. REPAIRED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP AT SEAT 9D. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA991018Solenoid · defectiveDFW - FLT 1068 - EN ROUTE DFW/CLT AFTER TAKEOFF, UNABLE TO RAISE LANDING GEAR HANDLE. AIR INTERRUPTED, RETURNED DFW, AND LANDED WITHOUT INCIDENT. REPLACED ANTI-RETRACT SOLENOID. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA990323Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS AT FORWARD GALLEY INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT STRIP AT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA982131Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AT SEAT ROW 6 HAD ONE BULB INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT SEAT ROW 6. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980413O-Ring · defectiveSAT - FLT 249 - DURING CRUISE, NR 1 HYDRAULIC QTY DEPLETED TO ZERO. CREW FOLLOWED ALTERNATE PROCEDURES TURNING OFF SYSTEM NR 1 PUMPS ON ENGINES 1 AND 2. LANDING GEAR ALTERNATE PROCEDURES WERE FOLLOWED AND THE AIRCRAFT LANDED SAT WITH NO FURTHER INCIDENT. RESDR AALA960242Inverter · defectiveBNA - FLT NR 580 - DURING APPROACH TO BNA, FWD BEGAN CHIMING NUMEROUS TRIPLE ALERTS, NR 1 FMC WENT OUT. NR 1 MFDU WENT OUT. ESSENTIAL AC BUS WARNING ANNUNCIATED ON RIGHT MFDU FOLLOWED BY FAULTS ON YAW DAMPER SYSTEM 1 AND 2 AND NR 1 AND 2 AUTOTHROTTLE SYSTEMSSDR AALA951561Valve · defectiveDFW - FLT 0544 - AFTER TAKEOFF DFW WHEN LANDING GEAR RETRACTED, THE NLG ALERT ON THE MFDU WAS ACTIVATED. RECYCLED GEAR WITH SAME RESULT. AIRCAFT RETURNED DFW AND LANDED WITHOUT INCIDENT. REPLACED SEQUENCING VALVE AND RESTRICTOR. SYSTEM GROUND CHECKED, NORM