SDR DLL10010128Unknown · odorELECTRICAL ODOR REPORTED IN VICINITY OF ROW 30 SEATS ABC, NO SMOKE OBSERVED. DROPPED CEILING PANELS AND PSU PANELS FROM ROWS 27 AB TO 31 AB, NO EVIDENCE OF ANY ODOR OR ELECTRICAL DAMAGE. CHECK COCKPIT AND LOWER GALLEY C/B PANELS FOR POPPED C/BS, ALL OK.Jan 24, 2001 · N1734D · Lkheed 10113851 · Air Distribution SystemSDR DLL10002290A/C Pack · odorON TAXI OUT STRONG FUMES REPORTED-RETURNED TO GATE FOR VISUAL INSPECTION. NONE REPORTED. AFTER T/O FUMES REPORTED AGAIN. ISOLATED PACK NR 3, NO CHANGE. ISOLATED NR 1 PACK, SOME DECREASE. REPLACED NR 2 ACM PER M/M. RAN PACKS FOR 2 HOURS. NO FUMES NOTEDNov 23, 2000 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10002239Engine · leakingON CLIMBOUT, ALL THE AFT LAV SMOKE DETECTORS WENT OFF. ON RETURN TO GATE, STRONG OIL SMELL AND BLUE HAZE IN CABIN. FOUND NUMBER 3 ENGINE LEAKING OIL AND ENTERING PNEUMATIC SYSTEM. REPLACED ENGINE.Nov 17, 2000 · N1734D · Lkheed 10113851 · Engine Oil Distribution (Airframe Furnished)SDR DLL10002184A/C Pack · failedON TAKEOFF ODOR DETECTED IN CABIN SMELL LIKE AN OVERHEATING PACK SLIGHT HAZE NOTED IN AFT CABIN, 2 LAV SMOKE DETECTORS ACTIVATED BRIEFLY ALL ACM AND PACK INDICATIONS NML. FOLLOWED POM PROCEDURES AND SECURED NR 3 PACK HAZE DISSIPATED FWD TO MCO AND PNov 7, 2000 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10002139Acm · smokeOILY SMOKE IN AFT CABIN ON CLIMBOUT. ISOLATED NR 1 ENG AND PACK, SMOKE DISSIPATED. FOLLOWED AIR CONDITIONING SMOKE PROCEDURE IN POM. ENDED UP WITH 1 PACK OFF AND OTHER SWITCHES LATCHED. REPLACED NR 1 ACM AND INNER DUCT HOUSING TO THE HEAT EXCHANGER. REPLAOct 31, 2000 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10002127Housing · leakingNR 1 ENG OIL QTY DROPPED FROM 16 TO 4 QTS IN 1.5 HRS OIL QTY DECREASED TO ZERO, ENGINE SHUTDOWN PER POM 23-107. RAPID DECREASE IN OIL QTY OIL PRESS REMAINED ABOVE 40 PSI UNTIL LANDING. FOUND GEARBOX CHIP DET MISSING FROM HOUSING AND OIL LEAKING OUT. REPLACEOct 27, 2000 · N1734D · Lkheed 10113851 · Engine Oil Distribution (Airframe Furnished)SDR DLL10001458Acm · failedON CLIMBOUT WITH 3 PACKS ON, CABIN FILLED WITH LIGHT BLUE SMOKE. REPLACED NR 3 ACM.Aug 2, 2000 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10001272Computer · failedDURING NAV ACCURACY CHECK AFTER TAKEOFF, NR 2 AND NR 3 INS NOT WITHIN TOLERANCE. REPLACED NR 2 AND NR 3 CAROUSELS.Jul 6, 2000 · N1734D · Lkheed 10113851 · Independent Position Determining SystemSDR DLL10992380Engine · failedBIRD STRIKE ON NR 1 ENGINE AT LIFTOFF. ENGINE BEGAN TO VIB, SURGE, STALL AND TGT ROSE TO 900 DEGS FOR GREATER THAN 30 SECS. REPLACED ENGINE.Oct 27, 1999 · N1734D · Lkheed 10113851 · Engine (Turbine/Turboprop)SDR DLL10991516Tire · failedNR 3 RT TIRE THREW RECAP ON LANDING. RUPTURING 2 HYD LINES CAUSING A LOSS OF C-SYSTEM HYD FLUID ON TAXI IN. REPLACED TIRE AND LINES.Jul 5, 1999 · N1734D · Lkheed 10113851 · TireSDR DLL10990426Engine · failedENG FLAME-OUT OCCURED 5 MINUTES AFTER T/O ON CLIMBOUT. APPARENTLY RESULTED FROM FAILURE OF NR 1 ENG FUEL HP SOV. REPLACED ENGINE.Mar 1, 1999 · N1734D · Lkheed 10113851 · Engine (Turbine/Turboprop)SDR DLL10990250Power Supply · inopEMERGENCY EXIT LIGHT FLOOR TRACK INOP FWD CABIN. REPLACED POWER SUPPLY.Feb 6, 1999 · N1734D · Lkheed 10113851 · Emergency LightingSDR DLL10982240Battery Pack · dischargedFWD EMER EXIT LIGHTS ILLUM TWICE DURING FLIGHT. FOUND BATTERY PACK AT 1L DOOR OPS INTERMITTENTLY. REPLACED SAME, OPS CK GOOD.Oct 30, 1998 · N1734D · Lkheed 10113851 · Emergency LightingSDR DLL10981315O-Ring · leakingENG NR 1 SHUTDOWN IN FLT DUE TO HIGH FUEL FLOW AND FUEL USED INDICATIONS WITH ENG AT IDLE F/F IND. 9,500 TO 10,000 LBS. POM COMPLIED WITH FOR HIGH FUEL USE AND ENG SHUTDOWN. FOUND O-RING SEAL LEAKING AT FUEL FILTER FUEL LINE. REPLACED SEAL PER MM AND ENG RUJun 22, 1998 · N1734D · Lkheed 10113851 · Engine Fuel DistributionSDR DLL10980993Skin · crackedTWO FASTENER HOLES WERE FOUND CRACKED IN THE LOWER WING SKIN AT THE END OF THE SKIN SPLICE STRAP AT STRINGER 10, IWS 570. THE CRACKS ARE THE SUBJECT OF SID AD 95-20-04, R1 (ITEM 57-3-4). THE CRACKS WERE REMOVED BY OVERSIZING THE HOLES WITH AN INSURANCE CUT.May 8, 1998 · N1734D · Lkheed 10113851 · Wing, Plate/SkinSDR DLL10972490Valve · malfunctionedNR 2 PACK OVHRHEAT ON TAXI OUT, SMOKE AND FUMES IN THE CABIN. ALSO, NR 3 PACK CAN NOT BE CONTROL WITH SWITCH IN COCKPIT. REPLACED FLOW CONTROLLED VALVE, NO HELP. REPLACED NUMBER 3 TURBINE BYPASS VALVE.Nov 28, 1997 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10971792Pack Valve · seizedON TAXI OUT, CABIN FILLED WITH SMOKE FOUND NR 3 PACK VALVE NOT FULLY CLOSED. REPLACED PACK VALVE.Sep 13, 1997 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10971029Frame · crackedDURING THE ACCOMPLISHMENT OF SI 7-63916-12AD, OPN 88 NDT FOUND A .75 INCH LONG CRACK IN THE LWR HORIZONTAL WEB OF THE STA 983 FRAME. REPAIRED FRAME PER LCC-7622-325 AND LCC-7622-328 WITH THE EXCEPTION THAT THE LCC-7622-328-110 AND -112 FITTINGS WILL BE MMay 21, 1997 · N1734D · Lkheed 10113851 · Fuselage Main, FrameSDR DLL10970964Skin · dentedTHE FUSELAGE SKIN WAS FOUND WITH A DEEP DENT AT FS 293 BETWEEN STR 15 AND 16. REMOVAL OF THE DAMAGE RESULTS IN A CUT OUT SIZED 4.5 LONG (FWD / AFT) BY 2.5 WIDE (UP/DOWN). REPAIR DOUBLER AND TRIPLER FROM 0.063 2024-T3 AL CLAD MATERIAL. TAPER EDGES, FILLER FRMay 9, 1997 · N1734D · Lkheed 10113851 · Fuselage Main, Plate/SkinSDR DLL10970962Skin · dentedTHE FUSELAGE SKIN BETWEEN STA 860 TO 866 AND STR 48 TO 50 WAS FOUND DENTED AND REQUIRED CUTOUT. THE CUTOUT, THROUGH THE SKIN AND THE L-2 DOOR SURROUND DOUBLER, MEASURES 6 FORE/AFT BY 12 CIRCUMFERENTIALLY. THE SKIN PANEL IS A BONDED ASSEMBLY CONSISTING OF A 0May 9, 1997 · N1734D · Lkheed 10113851 · Fuselage Main, Plate/SkinSDR DLL10970298Skin · corrosionCORROSION FOUND AT STA 1645 AND STR 29 AFTER BULGE FOUND. A 12 BY 5 SECTION OF SKIN AND DOUBLER WERE TRIMMED TO REMOVE IT. ER/A INSTALLED REPAIR DOUBLER.Jan 27, 1997 · N1734D · Lkheed 10113851 · Fuselage Main, Plate/SkinSDR DLL10970127Pack Valve · malfunctionedSMOKE FROM AIR CONDITIONING THROUGHOUT CABIN, MID CABIN TEMP 200 DEGREES NR 3 PACK ACM DISCHARGE TEMP 140 DEGREES. LOCKED NR 3 PACK VALVE CLOSED, FWD TO MCO AND PLACARD PER MEL 21-21-01A.Jan 22, 1997 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10962405Duct · rupturedNR 2 ENG PNEUMATIC DUCT RUPTURE AFT OF BAGGAGE BIN WALL IN NR 3 BIN DAMAGING DUMP CHUTE TO AFT LAVATORIES RESULTED IN J-AREA OVHT AND AFT CARGO HOT LIGHT.Oct 28, 1996 · N1734D · Lkheed 10113851 · Pneumatic Distribution SystemSDR DLL10962094Batteries · dischargedEMERGENCY FLASHLIGHT AT R4 DOOR INOP REPLACED BATTERY AND BULB. CKS OK.Sep 10, 1996 · N1734D · Lkheed 10113851 · Emergency LightingSDR DLL10962093Light · inoperative3R EXTERIOR EMER EXIT LGT INOP. RELAMPED. CKS OKSep 10, 1996 · N1734D · Lkheed 10113851 · Emergency LightingSDR DLL10961899Power Supply · inoperativeCABIN EMERGENCY EXIT SIGNS AT 2L AND LT CLASS DIVIDER INOP. REPLACED PWR SUPPLY, TESTS OK.Aug 14, 1996 · N1734D · Lkheed 10113851 · Emergency LightingSDR DLL10960712Megaphone · inoperativeFWD MEGAPHONE INOP. REPLACED FWD MEGAPHONE, OPS CK NORMAL.Mar 30, 1996 · N1734D · Lkheed 10113851 · Emergency EquipmentSDR DLL10953546Duct · crackedDURING CLIMB-OUT THROUGH FL 220, A MUFFLED BANG WAS HEARD. AFT OVERFLOW VALVE WENT FULL CLOSED AND FWD VALVE SLOWLY WENT CLOSED. AS AIRCRAFT CLIMBED THROUGH FL 280, LEVEL AT FL 350 CBN, CLIMB AT 100 FPM. UNLATCHED COOL AIR OVRBD SWITCH. DESCENDED TO FL 240Aug 29, 1995 · N1734D · Lkheed 10113851 · Air Distribution SystemSDR DLL10953535Pack · smokingSMOKE IN AFT CABIN DURING FLT - ISOLATED NR 3 PACK AND APPEARED TO CLEAR - PACK TEMPS NORMAL. CORR. ACTN. CHKD ALL 3 A/C PACKS AND OK. RAN SYSTEMS ON GROUND WITH NO ODORS OR VISIBLE POLLUTANTS IN CABIN. RENDERED NR 3 PACK INOP PER MEL 21-51-07A AND PLAAug 29, 1995 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10953232Pack · failedAFTER TAKEOFF, WHEN PACKS TURNED ON THERE WAS A LOUD GRINDING NOISE PLUS SMOKE AND FUMES IN COCKPIT AND CABIN. TURNED OFF NR 1 PACK SMOKE AND FUMES DISSIPATED. NR 1 PACK WAS REPLACED, OPERATION NORMAL.Jul 27, 1995 · N1734D · Lkheed 10113851 · Cabin Cooling SystemSDR DLL10951349Blkhd Angle · crackedDURING LETTER CHECK, FOUND FS 1363 BULKHEAD LOWER CHORD ANGLE CRACKED BETWEEN STRINGER 18 AND STRINGER 19. REPAIRED PER SRM 53-11-00 PG 931.Mar 28, 1995 · N1734D · Lkheed 10113851 · Fuselage Main, Bulkhead
Back to N1734D, cancelled Mar 12, 2001