N17535, cancelled Aug 29, 2001
Service difficulty reports · 32
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17535' AND deregistration_id = 'N17535-2001-08-29' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17535' AND deregistration_id = 'N17535-2001-08-29' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 20000426SH015Jackscrew · making metalDURING INSPECTION OF THE HORIZONTAL STABILIZER JACKSCREW ASSY, METAL SHAVINGS WERE FOUND WITHIN THE GREASE ON AND AROUND THE JACKSCREW. FURTHER, THE ACME SCREW AND NUT WEAR CHECK SHOWED THE END PLAY WAS BEYOND LIMITS. THE ESTABLISHED LIMITS ARE .003 INCH - SDR GTIA9901084Wire · failedMYR - BOTH EMERGENCY NACELLE LIGHTS INOPERATIVE. TRANSFERRED TO DEFERRED MAINTENANCE ITEM NR 333. REPAIRED WIRING AT AFT FLIGHT ATTENDANT PANEL EMERGENCY LIGHTS 'TEST' SWITCH. FUNCTIONAL CHECK GOOD, REF DC-9 WIRING DIAGRAMS 33-31-01. (M)SDR GTIA9900989Wire · looseFORWARD ONE-THIRD OF EMERGENCY FLOOR ESCAPE PATH LIGHTS INOPERATIVE. FOUND WIRES OUT ON FLOOR ROW EIGHT RESECURED AS NECESSARY. OPERATION CHECK GOOD IAW DC-9 MM 33-50. (M)SDR GTIA9900942Wire · looseFORWARD ONE-THIRD OF EMERGENCY FLOOR ESCAPE PATH LIGHTS INOPERATIVE. FOUND WIRE OUT OF FLOOR ROW EIGHT. RESECURED AS NECESSARY. OPERATION CHECKS GOOD IAW DC-9 MM 33-50. (X)SDR GTIA9800075Light · inoperativeOKC - FLT 902 - EMERGENCY FLOOR TRACK BROKE BETWEEN ROWS 11-15. REPAIRED FLOOR TRACK AND LIGHTING IAW DC-9 MM 33-51. OPERATIONAL CHECKS GOOD. (X)SDR GTIA9800020Slide · fell offMAIN CABIN DOOR SLIDE PACK FELL OFF. REINSTALLED MAIN CABIN DOOR SLIDE IAW DC-9 MM 25-62-0, INSTALLATION CHECKS GOOD. RII ACCOMPLISHED. (M)SDR GTIA9700414Battery Pack · dischargedDTW - FLT 610 - ON DAILY INSPECTION, LEFT AND RIGHT EMERGENCY NACELLE LIGHTS WOULD NOT ILLUMINATE. REPLACED LEFT AND RIGHT EMERGENCY NACELLE LIGHTS BATTERY PACKS IAW CHAPTER 33-53-0. OPS CHECK GOOD. (M)SDR GTIA9700413Slide · fell offDTW - FLT 841 - DURING DAILY INSPECTION, FOUND GALLEY DOOR EMERGENCY SLIDE HAD FALLEN OFF. INSTALLED GALLEY DOOR EMERGENCY SLIDE IAW DC9 MM 25-62-0. RII INSPECTION PERFORMED. (M)SDR GTIA9700405Fire Loop · malfunctionedCLIMBING THROUGH 8,000 FEET THE 'A' LOOP LIGHT CAME ON AS WELL AS THE LIGHT FOR NR 1 ENGINE, WENT TO 'B', TEST OK. GROUND OPS CHECKED NR 1 ENGINE FIRE LOOP SYSTEM IAW 26-12-0. COULD NOT DUPLICATE PROBLEM. UNIT OPS CHECKS GOOD. NO DEFECTS NOTED AT THIS TIMESDR CALA9701119Connector · dirtyTHE LT MLG UNSAFE LIGHT REMAINED ILLUMINATED AFTER GEAR EXTENSION ON APPROACH. ABNORMAL PROCEDURES WERE COMPLIED WITH AND THE EMERGENCY GEAR EXTENSION LEVER WAS PULLED. A TOWER FLY-BY WAS PERFORMED AND THE GEAR WAS CONFIRMED DOWN. THE AIRCRAFT LANDED WITHOUSDR CALA9601424Actuator · inoperativeWHEN GEAR WAS RETRACTED ON TAKEOFF, THE GEAR DOOR OPEN AND RIGHT MAIN GEAR UNSAFE LIGHTS REMAINED ILLUMINATED. APPROXIMATELY 15 SECONDS LATER THE SPEED BRAKE SPOILER HANDLE SOUNDED AS THOUGH IT CYCLED TO AIR MODE AND BOTH GEAR UNSAFE LIGHTS EXTINGUISHED. THE SDR CAL951067Latch Spring · lack of lubeFLT NR 1090 - ATL - THE LT MLG RED UNSAFE LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION AND THE GEAR DOOR OPEN LIGHT ILLUMINATED DURING UPLATCH CHECK. THE RED UNSAFE LIGHT AND GEAR DOOR OPEN LIGHT EXTINGUISHED AFTER UPLATCH CHECK. 'ABNORMAL' PROCEDURES WESDR CAL951020Skin · corrodedHOU - INSPECTION FOUND CORROSION ON SKIN AT STA 250 BELT FRAME, LONGERON 25L. A DOUBLER REPAIR WAS INSTALLED IAW SRM 53-04, FIGURE 38. (X)SDR CAL950991Fitting · corrodedHOU - INSPECTION FOUND INTERGRANULAR CORROSION AT BELTFRAME STATION 832, FITTING TO RIGHT CUSP. THE FITTING WAS REPLACED IAW SRM 51-30-0. (M)SDR CAL951055Bulkhead · corrodedHOU - INSPECTION FOUND CORROSION NEAR T-CAP ON RIGHT SIDE OF AFT PRESSURE BULKHEAD. THE CORRODED SECTION WAS CUTOUT. A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-03, FIGURE 22. (M)SDR CAL951023Doubler · corrodedHOU - INSPECTION FOUND FINGER DOUBLER CORRODED AT STA 218, LONGERON 26L. THE FINGER DOUBLER WAS REMOVED AND REPLACED IAW SRM 51-30-2. (X)SDR CAL951022Bracket · corrodedHOU - INSPECTION FOUND CABIN FLOOR SUPPORT BRACKET AT STA 160, AND 8 INCHES - 10 INCHES, LEFT OF CENTERLINE CORRODED. THE BRACKET WAS REMOVED AND REPLACED IAW SRM 51-30-0. (X)SDR CAL951021Belt Frame · crackedHOU - INSPECTION FOUND A .25 INCH CRACK COMING FROM HI-LOCK HOLE ON BELT FRAME AT STA 980, LONGERON 16R. THE CRACKED SECTION OF BELT FRAME WAS CUT OUT AND A NEW SECTION WAS SPLICED IN PER SRM 53-03, FIGURE 32. (X)SDR CAL950993Frame · crackedHOU - INSPECTION FOUND A 2 INCH CRACK EXTENDING FROM FASTENER HOLE ABOVE FLOOR ON FRAME AT STATION 813. THE FRAME WAS REMOVED AND REPLACED IAW SRM 51-10-03. (M)SDR CAL950992Floor Supports · corrodedHOU - INSPECTION FOUND CORROSION ON CABIN FLOOR SUPPORTS AT STATION 200. THE CORROSION EXTENDED THE FULL LENGTH FROM LEFT TO RIGHT SIDE OF FUSELAGE. FOUR FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-2. (M)SDR CAL950988Frame · crackedHOU - INSPECTION FOUND A 3 INCH CRACK EXTENDING FROM FASTENER IN FRAME AT STATION 794, STRINGER 18L. THE FRAME WAS REPAIRED IAW SRM 53-11-3, FIGURE 1. (M)SDR CAL951057Skin · crackedHOU - INSPECTION FOUND TWO .75 INCH CRACKS AT RIVETS IN SKIN LAP AT STA 1038 ABOVE RIGHT PYLON. A DOUBLER AND FILLER REPAIR WAS INSTALLED IAW SRM 53-04, FIGURE 18. (M)SDR CAL951056Skin · crackedHOOU - INSPECTION FOUND A .75 INCH CRACK IN SKIN LAP AT STATION 1038 ABOVE LEFT PYLON. THE SKIN CRACK WAS CUT OUT. A FILLER AND DOUBLER REPAIR WAS INSTALLED IAW SRM 53-04, FIGURE 18. (M)SDR CAL951024Longeron · corrodedHOU - INSPECTION FOUND LONGERON 30 AT STA 218 CORRODED IN TWO. A LONGERON AND SPLICE WERE INSTALLED IAW SRM 53-02. (X)SDR CAL950995Longeron · crackedHOU - INSPECTION FOUND A .25 INCH CRACK IN LONGERON 8L AT STATION 446. THE LONGERON WAS REPAIRED IAW SRM 53-02. (M)SDR CAL951053Splice · crackedHOU - INSPECTION FOUND A 4 INCH CRACK IN LEADING EDGE SPLICE BETWEEN NR 6 AND NR 7 SLAT TRACK. THE LEADING EDGE SPLICE WAS REPAIRED IAW ECRA 5710-01701. (M)SDR CAL950990Le Splice · crackedHOU - INSPECTION FOUND A 1 INCH CRACK IN LEADING EDGE SPLICE BETWEEN THE NR 3 AND NR 4 SLAT TRACK. A DOUBLER WAS INSTALLED IAW ECRA 5710-01697. (M)SDR CAL950989Spar Cap · corrodedHOU - INSPECTION FOUND INTERGRANULAR CORROSION ON LOWER SPAR CAP AT FXLS 325. THE SPAR CAP WAS REPAIRED IAW SRM 57-01, FIGURE 2. (M)SDR CAL951054Door Jamb · crackedHOU - INSPECTION FOUND A 2 INCH CRACK AT LEFT LOWER CORNER OF AFT PRESSURE BULKHEAD DOOR JAMB. THE DOOR JAMB WAS REPAIRED IAW ECRA 5310-03176 AND EA 653A006. (M)SDR CAL950717Beam · corrodedIAH - DURING INSPECTION, FOUND CORROSION ON LONGITUDINAL BEAM AT FORWARD AIRSTAIR CUTOUT BETWEEN STATION 160 AND 200. THE LONGITUDINAL BEAM WAS REMOVED AND REPLACED IAW SRM 51-30-00. (M)SDR CAL950716Skin · crackedIAH - DURING INSPECTION, FOUND A 1.5 INCH CRACK IN FUSELAGE SKIN AT AFT LOWER CORNER OF FORWARD AIRSTAIR DOOR CUTOUT. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-05, FIGURE 57A. (M)SDR CAL950306Skin · crackedIAH - A .875 INCH CRACK WAS FOUND IN FUSELAGE SKIN AT BS 965R, THREE INCHES ABOVE L15. A DOUBLER WAS INSTALLED IAW SRM 53-04, FIGURE 12B. (W)
Back to N17535, cancelled Aug 29, 2001