FAA incident reports · 5
FAA accident and incident reports matched to this aircraft by N219US and the event date: up to this one’s cancellation.
Incident 19990107015539ITakeoff Ground Roll · Minneapolis, MN(-5) Aircraft aborted takeoff at 70 KTS due to dual bleed indication. Maintenance personnel determined that APU bleed valve failed in open postion. Replaced APU load control valve.Incident 19981226042259IForced/Precautionary Landing · Kansas City, MO(-5) December 26, 1998, vanguard airlines Boeing 737-281, N219US, departed Kansas City International Airport, and returned to mci due to a cracked sliding window. Pressurization was not lost, vanguard's maintenance replaced the cracked window, right window…Incident 19970124006839IClimb · Denver, CONarrative: vanguard flight 612 returned to the field (dia) after flying for approximately 20 minutes, enroute to (mci) Kansas city, MO. (PIC) pilot in command was notified by flight attendant of a strong nauseous smell in the forward cabin. PIC elected to…Incident 19960415013459ITo Init Climb(1st Pwr Reduct) · Dallas-Ft Worth, TXNarrative: vanguard airlines (vam) flt 126 departed dfw for ict on takeoff/rotation the stick shaker activated. The crew made a turn back and landed uneventfully at dfw. Delta mx personnel repositioned the stall warning vane and returned the aircraft to…Incident 19891220065419ITakeoff Ground Roll · Miami, FLBlew a tire on takeoff roll. Pilot knew nothing about tire blowing out until he landed at destination.
Service difficulty reports · 90
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR P2EA99354Floorbeam · corrodedSJO - C-CHECK, FLOORBEAM WEB CORRODED AT BS 259.5, FROM WL 208.5 TO WL 206, BETWEEN LBL 13 INCH TO RBL 13 INCH. DEFECT SIZE, LENGTH 16 INCHES, WIDTH 5 INCHES. REPAIRED FLOORBEAM WEB AT BS 259.5 BETWEEN LBL 17 INCH AND RBL 14.5 INCH FROM WL 208.5 TO WL 193. SDR P2EA99351Floorbeam · corrodedSJO - C-CHECK, FLOORBEAM CORROSION AT BS 259.5, WL 208.5, BETWEEN LBL 20 AND RBL 15 INCHES. DEFECT SIZE, LENGTH 14 INCHES, WIDTH 4 INCHES. REPAIRED FLOORBEAM ANGLE AT BS 259 FROM LBL 23 INCHES TO RBL 21.5 INCHES WL 208. ALSO, REPLACED FLOOR BEAM UPPER ANGLESDR P2EA99350Angle · corrodedSJO - C-CHECK, FLOOR SUPPORT ANGLE CORRODED AT BS 270, WL 208.5, BETWEEN RBL 17 INCHE LBL 10 INCH. DEFECT SIZE, LENGTH 10 INCH, WIDTH 2 INCH. REPAIRED FLOOR SUPPORT ANGLE AT BS 270, WL 208.5, BETWEEN LBL 54 INCH TO RBL 25.5 INCH PER COOPESA EO COO-3-53-714-9
See all 90 reports