N314UA, cancelled Feb 29, 2012
Service difficulty reports · 63
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N314UA' AND deregistration_id = 'N314UA-2012-02-29' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N314UA' AND deregistration_id = 'N314UA-2012-02-29' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA06200Connector · looseEMERGENCY EXIT LIGHT STRIP HAS SEGMENT THAT DOES NOT ILLUMINATE BY 2B AND STRIP BY AFT GALLEY BROKEN. SECURED LOOSE CONNECTIONS AT LIGHT STRIPS. BOTH TEST NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA05555Lamp · inoperativeAFT SECTION OF CABIN FLOOR EMERGENCY LIGHTS INOP. FOUND FAULTY LAMP, REPLACED LAMP. OP CHECK GOOD. ACFT OK FOR SERVICE.
SDR 2008UALA05476Light · unsecureEMERGENCY LIGHT INOPERATIVE ROW 16 AND AFT. SECURED EMERGENCY LIGHT AND OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA05460Feeder Cable · damagedEMERGENCY LIGHTS ARE INOP FROM ROW 16 TO AFT GALLEY. REPLACED WALL FEEDER CABLE. EMERGENCY LIGHT BATTERY NEEDS TO CHARGE TO FINISH OPS CHECK.SDR 2008UALA04253Coupling · leakingCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: 1275 PSI AND SLOWLY DECREASING. FOUND THE JUMP SEAT MASK CONNECTION POINT TO ACFT O-RING DAMAGED. REPLACED WITH NEW MASK, OP CHECKED MASK, NORMAL. SERVICED O2 LEVELS. ACFT OK FOR SDR 2008UALA04194O-Ring · leakingCREW O2 INDICATES 680 PSI. FOUND THE JUMP SEAT MASK CONNECTION POINT TO ACFT O-RING DAMAGED. REPLACED WITH NEW MASK, OPS MASK NORMALLY, SERVICED O2. ACFT OK FOR SERVICE.SDR 2008UALA03923Oxygen Bottle · reads low700 PSI ON COCKPIT O2 GAUGE. PLS CHECK DIRECT GAUGE ON BOTTLE AND CONTACT SAM.SDR 2008UALA03856Oxygen Mask · leakingF/O OXYGEN MASK HAS A LOW CONSTANT FLOW WHEN NOT STOWED IN ITS COMPARTMENT. *S/D* SUSPECT PRE FLIGHT CHECKS. REPLACED FIRST OFFICERS OXYGEN MASK, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA02452Light · inoperativeEMERGENCY EXIT LIGHT STRIP ON FLOOR AT THE G6 GALLEY IS INOP. REMOVED AND REPLACED EEL STRIP AT G6 GALLEY FLOOR. OPS CHECKED GOOD.SDR 2008UALA02148Intercostal · crackedL1 DOOR INTERCOSTAL WEBS CRACKED AT STA 294.5 STR 12 LT AND STR 7 LT AND CLIP AT STA 360 AT STR 10 LT. MAJOR REPAIR ACCOMPLISHED: REPLACED WEBS AND CLIP.SDR 2008UALA02147Stringer · crackedSTRINGER SPLICE CHANNEL CRACKED AFT OF FWD ENTRY DOOR AT STRINGER 14 LT. MAJOR REPAIR ACCOMPLISHED: REPLACED CHANNEL.SDR 2008UALA01357Stringer · damagedSTRINGER 23R AT STA 288 DAMAGED. MAJOR REPAIR: ACCOMPLISHED REPAIR.SDR 2007UALA05244Smoke Detector · failedCARGO TEST FAILED A-B FWD AND AFT. SUSPECT CIRCUIT BREAKER LEFT OPEN DURING MAINTENANCE. RESET CIRCUIT BREAKER OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2007UALA04132Unknown · malfunctionedAUTO FAIL LIGHT AND LOST CABIN PRESSURE AT 4000 FEET.
SDR 2007UALA04044Wire · brokenFOUND CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. REPAIRED BROKEN WIRES NEAR LAST ROW AND REMOVED WATER RESIDUE. OPS NORMAL.
SDR 2007UALA03718Light · faultyFLOOR EEL LIGHTS VERY DIM FROM SEAT 18 ABC TO AFT GALLEY. REPLACED 3 EEL STRIP LIGHT ASSY'S. EEL LIGHTS OPCK NORMAL.SDR 2007UALA02595Lamp · inoperativeEMERGENCY LIGHT AT SEAT POSITION 5 ABC INOP. [07-27-07] RELAMPED EMERGENCY AISLE L AMP, OPS CHECK.SDR 2006UALA02134Angle · corrodedFWD GALLEY DOOR Z ANGLE CORRODED BS 294.5 - BS 328 RBL 54 -RBL 55 STR 17R TO STR 17R. REMOVED AND REPLACED Z ANGLE, REFERENCE SRM 51-40-02.SDR 2006UALA02133Skin · crackedFWD GALLEY DOOR CUTOUT FUSELAGE SKIN HAS A CRACK RUNNING FROM CUTOUT THROUGH AND PASSED RIVET HOLE AT LOWER AFT CORNER STA 328 STR 17R. REMOVED CRACK. FABRICATED AND INSTALLED DOUBLER, TRIPLER, AND STRUCTURAL FILLER REPAIR PER SRM 53-10-01 REPAIR 2.SDR 2006UALA02132Skin · crackedEXTERNAL FUSELAGE SKIN ELECTRONICS BAY COOLING DUCT CUT OUT AFT SIDE IS CRACKED. REMOVED CRACKED. FABRICATED AND INSTALLED DOUBLER REPAIR PER MM 53-30-99.SDR 2006UALA02128Line · severedNR 2 ENGINE FIREX SUPRESSION LINE FOUND SEVERED IN THE NR 6 FLAP TRACK FAIRING JUST IB OF THE NR 6 FLAP TRANSMISSION. FOUND THAT THE LINE WAS NOT PROPERLY CLAMPED IN PLACE. REPLACED LINE. ENSURED LINE WAS PROPERLY CLAMPED.SDR 2006UALA02125Frame · crackedFWD CABIN STA 294 STR 17R LOWER FRAME CRACKED. REMOVED DAMAGE. FABRICATED AND INSTALLED FILLER AND REPAIR ANGLE. REFERENCE SRM 51-70-11 TABLE III.SDR 2006UALA02124Skin · crackedLT HORIZONTAL STAB TE LOWER SKIN APPROX 64 INCHES FROM FUSELAGE AND 2 INCHES FWD OF REAR SPAR CRACKED. REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR DOUBLER SHIM AND ACCESS PLATES. REFERENCE SRM 5-10-01 REPAIR 6 FIGURE 803.SDR 2006UALA01990Light · inoperativeFOUND EMERGENCY STRIP LIGHTING ON FLOOR INOP FROM EXIT ROW AFT. REPLACED CABLESDR 2006UALA01977Landing Gear · malfunctionedRETURNED TO DEN DUE TO GEAR RETRACTION PROBLEM. FAULTY NOSE LANDING GEAR MODULAR PACKAGE. REPLACED THE MODULAR PACKAGE. ROOT CAUSE UNKNOWN.SDR 2006UALA01184Skin · damagedSKIN DAMAGE WAS FOUND FROM STA 901 TO 919 BETWEEN STR 27L AND 26L.SDR 2006UALA01183Skin · damagedSKIN DAMAGE WAS FOUND BETWEEN STA 917 TO 939 BETWEEN STR 25L AND 26L.SDR 2006UALA01112Skin · gougedAFT BELLY SKIN GOUGED.SDR 2006UALA00648Wire Harness · damagedNR 2 ENG WINDMILLED IN FLIGHT AT 0 PSI OIL PRESS FOR APPROXIMATELY 7 MINUTES. ENG SHUT DOWN DUE TO SUSPECTED FUEL LEAK. ACCOMPLISHED ENGINE WINDMILLING INSPECTION REF JRH2-95-63. ACCOMPLISHED ENGINE IDLE RUN AND LEAK CHECK NO LEAKS NOTED. CHECKED CHIP DETECTOSDR 2006UALA00634Light · inoperativeAFT CABIN EEL LIGHTS INOP FROM ROW 15 AFT TO AND INCLUDING EEL STRIP IN FRONT OF AFT GALLEY CART STOWAGE COMPARTMENT.SDR 2005UALA01446Landing Gear · malfunctionedNO INDICATION OF NOSE GEAR COMING UP. CREW SPOKE WITH SAMC, NO POSITIVE RESULT WITH GEAR. SWITCH S845 "NOSE GR DOWN SENSOR" FAILED. REPLACED SWITCH AND PERFORMED OPERATIONAL CHECK (SWUNG GEAR) OF THE GEAR, CHECKS GOOD.SDR 2005UALA01293Lamp · inoperativeEEL LIGHTS INOP FROM ROW 17 AFT. REPLACED EEL CABLE AND MOST AFT LAMP.SDR 2005UALA00450Bear Strap · damagedAFT CARGO DOOR CUTOUT BEAR STRAP HAS PRE-EXISTING CUTOUT FOR REPAIR. *S/D* MAJOR REPAIR. INSTALLED DOUBLER-TRIPLER REPAIR PER SRM 53-00-01 FIG 230.SDR 2005UALA00440Stringer · corrodedSTR 25L HAS CORROSION FROM STA 767 TO 787.SDR 2005UALA00430Crease Beam · corrodedAFT GALLEY AREA STA 947.5 AND 986 HAS CORROSION, 50 PERCENT MATERIAL LOSS, CREASE BEAM. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW CREASE BEAM & DRAIN PAN.SDR 2005UALA00408Frame · crackedFUSELAGE FRAME IS CRACKED AT STA 616 BELOW STR 17R. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE AND INSTALLED ANGLE DOUBLER.SDR 2005UALA00090Light · inoperativeAFT CABIN EEL LIGHTS INOP FROM ROWS 15 TO AFT GALLEY. REPLACED EEL CABLE AND MISSING END CAP.SDR 2001UALA01402Circuit Breaker · faultyACFT RETURNED TO FIELD DUE TO NR 1 GEN PROBLEMS. ON CLIMB, FLIGHT REPORTED LOSS OF NR 1 GEN BUS & SUSTAINED LOSS OF CAPTAINS INSTRUMENTS: BOTH CAPT'S EFIS DISPLAYS WENT BLANK, NR 1 GEN BUS OFF LIGHT ILLUM, NR 1 TRANSFER BUS OFF LIGHT ILLUM AND C819 NR 1 TRANSDR 2001UALA01401Control UnitUNSCHEDULED LANDING DUE TO ELECTRICAL PROBLEMS. FLIGHT CREW REPORTED A SUSTAINED LOSS OF CAPTAINS INSTRUMENTS IN FLIGHT. BOTH CAPTIANS EFIS DISPLAYS WENT BLANK, THE NO.1 GENERATOR BUS DROPPED OFF LINE, THE NO.2 BUS FAILED TO PICK UP THE NO.1 TRANSFER BUS LOAD,SDR 2001UALA00713Frame · crackedFRAME CRACKED STA 189, WL 206, RIGHT SIDE. MAJOR REPAIR ACCOMPLISHED. INSTALLED WEB REPAIR ANGLE UNDER WEB STIFFENER.SDR 2001UALA00705Attach Fitting · corrodedAFT LEFT AND RIGHT FAILSAFE ATTACH LUGS ON VERTICAL STABILIZER FRETTED. REMOVED BUSHINGS, REWORKED LUG AREA AND INSTALLED NEW BUSHINGS.SDR 2001UALA00689Bulkhead · crackedWEB CRACKED AT UPPER RT RADAR MOUNT OUTBOARD LWR SIDE STA 178. INSTALLED DOUBLER.SDR 2001UALA00683Strap · corrodedWEB SUPPORT STRAP CORRODED. AFT PIT STA 787-820 RBL 19. MAJOR REPAIR ACCOMPLISHED. REPLACED STRAP.SDR 2001UALA00682Door Frame · crackedR1 DOOR CUTOUT FRAME CRACKED AT INBD RADIUS. BS 296.5 STR 7R MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2001UALA00687Mount · crackedCRACK AT LOWER INBD FASTENER OF UPPER LH ANTENNA MOUNT ALONG STRAP EDGE. STA 178. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2001UALA00635Attach Fitting · corrodedVERTICAL STABILIZER LUGS FRETTING ON BUSHING FLANGES. REWORKED VERTICAL STABILIZER ATTACH FITTINGS.SDR 2001UALA00634Threshold · corrodedAFT PIT DOOR THRESHOLD WEB CORRODED AT STA 789. MAJOR REPAIR ACCOMPLISHED.REPLACED THRESHOLD WEB.SDR 2001UALA00627Door Frame · damagedDAMAGE AT AFT CARGO DOOR CUTOUT STA 845, BETWEEN STR 21R AND 22R. TRIMMED OUT AFFECTED MATERIAL. ACCOMPLISHED REINFORCEMENT REPAIR. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00610Doubler · crackedAFT PRESSURE BULKHEAD REPAIR AREA AT 2:00 POSITION SKIN HAS GOUGES OR CRACKS. REMOVED OLD DOUBLER. INSTALLED NEW DOUBLER AND HAT CHANNEL. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00609Shear Tie · crackedFRAME TO STRINGER TIE IS CRACKED, LOCATED AT STA 500D AND STR 19R. INSTALLED DOUBLER AND ATTACHING PARTS.