Service difficulty reports · 94
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR GTIA2024101238429Unknown · odorFUME EVENT ON DESCENT -PERFORMED TSM 05-50-00-810-831-A. INSPECTED FOR CONTAMINATION PACK 1 IAW AMM 21-51-00. FOUND NO EVIDENCE OF CONTAMINATION. OPERATED APU BLEED TO DUPLICATE FAULT IAW AMM 12-33-21. NO ODOR DETECTED. A/C GOOD TO CONTINUE SVCSDR GTIA2024090938356Unknown · odorFLIGHT ATTENDANTS REPORTS MOLD SMELL IN FWD CABIN.-NO SMELL NOTED AT THIS TIME . PERFORMED APU CHECK FOR LEAKING AND OIL CHECK , NO DEFECT NOTED , REF: A320 AMM TSM 05-50-00-810-831-A. A TYPE 10 TRASH-ETC.SDR GTIA2023111437601Unknown · unknownF/A REPORTS CHEMICAL SMELL FROM AFT GALLEY AND CABIN SMELL COMES + GOES-REF T.I 2100-1908-01 AND T.I 2100-2002-CEO IAW AMM 49-00-00 T.C ACCOMPLISHED. NO DEFECTS FOUND A/C OK FOR SERVICE
See all 94 reports