N625AW, cancelled Jun 22, 2015
Service difficulty reports · 236
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N625AW' AND deregistration_id = 'N625AW-2015-06-22' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N625AW' AND deregistration_id = 'N625AW-2015-06-22' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2014111900003Proximity Sensor · inoperativeON TAKEOFF NLG DOOR REMAINED OPEN & UNLOCKED. ACCOMPLISHED TROUBLESHOOTING PROCEDURES. REPLACED NLG PROXIMITY SENSORS 30GA & 31GA IAW AMM 32-31-73-000-005-A & 32-31-73-400-005A. OPERATIONS CHECKED GOOD.SDR USAA2014103000002Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE AT ROWS 13, 17, 19, 24 & AFT GALLEY. REPLACED EMER LIGHTS POWER SUPPLY UNIT IAW AMM 33-51-38. OPERATIONS CHECKED OK.SDR USAA2014093000002Oil System · overservicedAPU SMELL AT GATE WET SOCK PLUS IRRITATION TO LUNGS & EYES. ACCOMPLISHED JOB CARD 26L00021001 & 26L00021002. FOUND APU OIL TO BE THE PROBLEM DECONTAMINATED APU COMPARTMENT.SDR USAA2014070200007Power Supply · failedBC 1 CHECK EMER POWER SUPPLY UNIT 13WL FAILED EMER LIGHT CHECK. REPLACED EMER POWER SUPPLY UNIT 13WL IAW AMM 33-51-38-400-001-A. PERFORMED OPERATIONS CHECK IAW JOB CARD 26L00025011, CHECKED GOOD.SDR USAA2014070200006Power Supply · failedC3 CHECK 10WL EMER POWER SUPPLY UNIT FAILED LIGHT CHECK. REPLACED 10WL EMER POWER SUPPLY UNIT LT FWD IAW AMM 33-51-38-400-001A. PERFORMED OPERATIONS CHECK IAW JOB CARD 26L00025011, CHECKED GOOD.SDR USAA2014070200005Slide · defectiveC3 CHECK SLIDE EXPANDED & COVER WILL NOT FIT PROPERLY ON AFT SIDE. R & R SLIDE IAW JOB CARD 26L00025011-AFTLH.SDR USAA2014062400004Slide · malfunctionedC1 CHECK L1 DOOR SLIDE HITS THE SIDE OF THE ACFT. REPLACED L1 DOOR SLIDE IAW JOB CARD 26100025011.SDR USAA2014061700013Floor Panel · damagedC1 CHECK HOLE DAMAGE ON FLOOR PANEL BETWEEN FRAME 54 TO 58 & BETWEEN -Y765 TO -Y1292. REPLACED FLOOR PANEL BETWEEN FRAME 54 TO 58 & BETWEEN -Y765 TO -Y1292 IAW SRM 51-72-11.SDR USAA2014061600005Shear Tie · crackedC1 CHECK CRACK ON SHEAR TIE AT FRAME 74, STRINGER 9R. REPLACED SHEAR TIE AT FRAME 74, STRINGER 9R IAW SRM 51-21-11 & EA 105986.SDR USAA2014061600007Seat Track · corrodedC1 CHECK CORROSION ON SEAT TRACK AT FRAME 54+15 INCHES, RBL 51. REPLACED SEAT TRACK AT FRAME 54+15 INCHES, RBL 51 IAW SRM 53-41-15-201 & EA 105989.SDR USAA2014061700009Floorbeam · corrodedC1 CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM UPPER SURFACE AT FRAME 67, Y 1292. REPLACED FLOORBEAM UPPER SURFACE AT FRAME 67, Y 1292 IAW SRM 51-72-11 & DWG D53472000.SDR USAA2014061600009Floorbeam · corrodedC1 CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FRAME 70, Y 160. REPLACED FLOORBEAM AT FRAME 70, Y 160 IAW DWG D53472000.SDR USAA2014061600008Floorbeam · corrodedC1 CHECK LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FRAME 66 & 5 INCHES, Y771. REPLACED FLOORBEAM AT FRAME 66 & 5 INCHES, Y771 IAW DWG D53472000.SDR USAA2014060900016Floorbeam · corrodedBC1 CHECK. CABIN FLOORBEAM CORRODED BETWEEN FRAME 66 & 70 AT Y765. R & R FLOORBEAM IAW SRM 51-42-11 & DWG D53472000.SDR USAA2014060900015Floorbeam · corrodedBC1 CHECK CABIN FLOORBEAM CORRODED BETWEEN FRAME 68 & 69 AT Y1292. R & R FLOORBEAM IAW SRM 51-72-11 & DWGS D53472188202, D53472000 & D53470100.SDR USAA2014050700007Lens · missingEMERGENCY LIGHT LENS MISSING AT ROW 16 LT. INSTALLED EMERGENCY LIGHT LENS AT ROW 16 LT.SDR USAA2014041400012Windshield · brokenLEFT CAPTAIN’S OUTER WINDOW PANE OVERHEATED & SHATTERED. REPLACED LT CAPTAIN’S OUTER WINDOW IAW AMM 56-11-11.SDR USAA2014041100007Windshield · crackedLEFT CAPTAIN`S OUTER WINDOW PAIR OVERHEATED & SHATTERED. ECAM ANTI-ICE LT WINDSHIELD. REPLACED LT CAPTAIN`S OUTER WINDOW IAW AMM 56-11-11, OPERATIONS CHECKED GOOD.SDR USAA2014032100004Power Supply · inoperativeEMERGENCY LIGHT TEST FAILED. REPLACED EPSU OVERWING RT SIDE.SDR USAA2014032100002Battery · dischargedAFT, SWIVEL, FLIGHT ATTENDANT FLASHLIGHT REQUIRES BATTERY REPLACEMENT. REPLACED AFT, SWIVEL, FLIGHT ATTENDANT FLASHLIGHT BATTERY.SDR USAA2014021000006Drain Valve · noisyLOUD NOISE COMING FROM AREA OF DOOR 1R STARTING ABOUT 7000' ON CLIMB OUT. IAW NON-ROUTINE NR 3057781, 3057758, 3057722, 3057755, 3057768, 3057802 & 3057804. REPLACED FWD GALLEY LAVATORY A ANTI-SIPHON DRAIN, AVIONICS FAN, DUCT EXTRACTION, GND POWER SERVICE DSDR USAA2014021000004Butterfly Valve · noisyEXTREMELY LOUD NOISE HEARD FROM BEHIND FWD GALLEY WATER SPIGOT. IAW LOG PAGES 3057775, 3057778 & 3057736, REPLACED COOLING AIR INLET CHECK VLV & BUTTERFLY VLV & TIGHTENED FOUR EACH DUCT CLAMPS.SDR USAA2014012700003Apu · odorCABIN ODOR, WHEN THE PILOTS TURNED ON APU A STRONG ODOR OCCURRED AS SOON AS THE JET WAY DOOR WAS OPEN. THE CREW DID NOT REQUEST MEDICAL ATTENTION, THE ACFT WAS SWAPPED.SDR USAA2014010200009Control Unit · inoperativeRETURN TO FIELD DUE TO ENG NR 2 THRUST REVERSER PRESSURIZED ECAM MESSAGE ON CLIMB OUT THROUGH FLIGHT LEVEL 320. REPLACED THE NR 2 ENGINE HYDRAULIC CONTROL UNIT.SDR USAA2013090900010Power Supply · inoperativeEMERGENCY LIGHT ESPU TEST FAILED. REPLACED ESPU WITH SERVICEABLE UNIT AND OPS CHECKED OK IAW AMM 33-51-38-0401--A.SDR USAA2013070100007Lens · missingROW 22 ACFT LT CLEAR EMERGENCY PATH LIGHT LENS MISSING. REPLACED ROW 22L EMERGENCY PATH LIGHT LENS.SDR USAA2013070100006Lens · missingROW 9 AC LEFT RED EMERGENCY PATH LIGHT MISSING RED LENS. REPLACED ROW 9L EMERGENCY PATH LIGHT LENS.SDR USAA2013062700008Spring · weakAFT LAVATORY A/C RT TRASH FLAP INOPERATIVE. REPLACED SPRING ON TRASH RECEPTACLE FLAP.SDR USAA2013062400022Unknown · odorF/A REPORTED A CIGARETTE LIKE ODOR IN BACK OF ACFT ALONG WITH AN ACRID ODOR. 1 OF THE F/A REPORTED FEELING NAUSEA AND EYE IRRITATION. ANOTHER F/A FELT DIZZY AND ILL WITH HIVE LIKE SYMPTOMS. THE PILOTS REPORTED NAUSEA ALONG WITH EYE AND THROAT IRRITATION. SDR USAA2013062600009Unknown · odorCABIN ODOR DURING FLIGHT. MX INSPECTED CABIN FOR AIR QUALITY, NO DISCREPANCIES FOUND.SDR USAA2013061700002Cover · missingEMERGENCY LIGHT COVER MISSING OVER ACFT LT OVERWING. REPLACED MISSING LENS COVER ON THE LT OVERWING.SDR USAA2013050900005Lens · missingEMERGENCY EXIT LIGHT RED LENS 11D MISSING. REPLACED EXIT SIGN ON SEAT 11D.SDR USAA2013050900003Lens · missingROW 11 FLOOR EMERGENCY EXIT LIGHTS WILL NOT ILLUMINATE. EXIT LIGHT ILLUMINATES, NO DEFECT. REPLACED MISSING LENS.SDR USAA2013050100012Floor Panel · delaminatedGO GO MOD - METAL SURFACE DAMAGE ON FLOOR PANEL 132FF BETWEEN STA 1163 TO STA 1323 & BETWEEN S35R TO S40R. REPLACED FLOOR PANEL 132FF IAW A320 AMM 25-54-11 & EA 204786.SDR USAA2013050100009Floor Panel · delaminatedGO GO MOD - DELAMINATION ON FLOOR PANEL 132JF BETWEEN STA 1323 TO STA 1483 & BETWEEN S35R TO S40R. REPLACED FLOOR PANEL 132JF IAW A320 AMM 25-54-11 & EA 204786.SDR USAA2013050100008Floor Panel · delaminatedGO GO MOD - DELAMINATION ON FLOOR PANEL 151LF BETWEEN STA 2616 TO STA 2723 & BETWEEN S40L TO S40R. REPLACED FLOOR PANEL 151LF IAW A320 AMM 53-22-12/14 & EA 204786.SDR USAA2013050100007Floor Panel · delaminatedGO GO MOD - DELAMINATION ON FLOOR PANEL 131EF BETWEEN STA 1163 TO STA 1323 & BETWEEN S40L TO S40R. REPLACED FLOOR PANEL 131EF IAW A320 AMM 53-22-12/14 & EA 204786.SDR USAA2013050100006Floor Panel · delaminatedGO GO MOD - DELAMINATION ON FLOOR PANEL 131HF BETWEEN STA 1323 TO STA 1483 & BETWEEN S40L TO S40R. REPLACED FLOOR PANEL 131HF IAW A320 AMM 53-22-12/14 & EA 204786.SDR USAA2013042900021Stringer · corrodedGOGO MOD - CORROSION ON STRINGER 43L AT FR56. REPAIRED STRINGER 43L AT FR56 IAW A320 SRM 53-00-13, FIG 202.SDR USAA2013042300015Flashlight · inoperativeFLASHLIGHT AT FORWARD FLIGHT ATTENDANT STATION NEEDS REPLACEMENT. REMOVED AND REPLACED FORWARD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT.SDR USAA2013040900003Lens · missingROW 11 EXIT LIGHTING ON BOTTOM OF SEAT IN AISLE IS BROKEN OFF. REPLACED MISSING EXIT LIGHT LENS AT SEAT ROW 11 LEFT.SDR USAA2013030500006Bolt · shearedMECHANICS REPORT - FOUND SHEARED BOLT ON SEAT TRACK STRINGER ATTACH POINT AT FORWARD WALL AFT CARGO LEFT SIDE IN CEILING. REPLACED SHEARED BOLT AT SEAT TRACK ATTACH POINT JUST AFT OF FR46 IAW A320 SRM 51-42-11.SDR USAA2013013000017Diaphragm · leakingR2 DOOR ASSIST BOTTLE LOW. REPLACED R2 DOOR ASSIST BOTTLE DIAPHRAGM AND SERVICED IAW AIRBUS MAINTENANCE MANUAL 52-10-00.SDR USAA2013011400025Strap · misroutedDOOR 1R WILL NOT ARM. REROUTED GIRT STRAPS ON R1 DOOR SLIDE IAW AIRBUS MAINTENANCE MANUAL 25-62-44-04.SDR USAA2012110100003Door · out of adjustBC2 CHECK - OUT ADJUSTMENT DIMENSION "B" BETWEEN STRIKER LEVER AND FINGER AT DOOR 832 (L2). ADJUSTED DIMENSION "B" BETWEEN STRIKER LEVER AND FINGER AT DOOR 832 (L2) IAW AMM 52-13-14-820-002-A ITEM 4A, STEP 1.SDR USAA2012103100010Door · out of adjustBC2 CHECK - OUT ADJUSTMENT DIMENSION "A" BETWEEN STRIKER LEVER AND FINGER AT DOOR 831 (L1). ADJUSTED DIMENSION "A" BETWEEN STRIKER LEVER AND FINGER AT DOOR 831 (L1) IAW A320 AMM 52-11-14-820-002-A ITEM 4A, STEP 2.SDR USAA2012110600005Doubler · corrodedC2 CHECK - CORROSION ON EXISTING REPAIR DOUBLER ON FUSELAGE SKIN BETWEEN FR69+5 INCHES TO FR69+17 INCHES & BETWEEN S31R TO S33R. REPLACED EXISTING REPAIR DOUBLER IAW A320 SRM 51-72-11, 53-41-11, PAR 5.D, FIG 205.SDR USAA2012092400013Extinguisher · unserviceableH2O FIRE EXTINGUISHER SEAL MISSING. REMOVED AND REPLACED H2O FIRE EXTINGUISHER IN THE AFT GALLEY AS REQUIRED.SDR USAA2012060600008Autothrust Sys · malfunctionedON FINAL APPROACH WITH APPROACH ACTUATED, AUTOTHRUST APPARENTLY DISCONNECTED AND WENT TO CLIMB POWER. CONFIGURATION WAS FLAP 2, GEAR DOWN. AIRCRAFT QUICKLY ACCELERATED AND OVERSPEED INDICATED FOR FLAPS 2 (ESTIMATED AT ABOUT 10 KNOTS). PERFORMED INSPECTION OFSDR USAA2012051600005Extinguisher · unserviceableAFT PORTABLE FIRE EXTINGUISHER NOT SERVICEABLE. REMOVED AND REPLACED AFT PORTABLE FIRE EXTINGUISHER.
Back to N625AW, cancelled Jun 22, 2015