Service difficulty reports · 26
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR DXTA2025040803003Handle · malfunctionedMAIN DOOR HANDLE: MAIN ENTRANCE DOOR EXTERIOR HANDLE WILL NOT STAY STOWED. IT DOES NOT SPRING STOWED. CORRECTIVE ACTION: REMOVED EXTERIOR DOOR HANDLE AND REPLACED BROKEN DOOR SPRING WITH NEW UNIT P/N: SL5204-2 AND REPLACED COTTER PIN WITH NEW UNIT P/N: MS24665SDR DXTA2025021902387Condenser · faultedUPON TAKEOFF ROTATION THE AMBER ACM OVERHEAT ANNUNCIATOR ILLUMINATED. OT WAS ACCOMPANIED WITH A BURNING SMELL IN THE AIRCRAFT. THE SMELL LASTED FOR A FEW MINITES AND WAS NOT NOTICEABLE AGAIN. THE REAR TAILCONE ACCESS COMPARTMENT ALSO SMELLED NORMAL UPON INSPESDR DXTA2024120901391Cable · frayedCAPTAIN MLG BRAKE PEDAL: LEFT SEAT RIGHT BRAKE PEDAL HAS VERY LITTLE BRAKING AND MECHANICAL BINDING SOUND. INSPECTED AND FOUND THE PILOT LEFT SEAT RIGHT BRAKE CABLE FRAYED AND PARTIALLY BROKEN UNDER FLOOR PANEL BELOW SEAT. R&R FRAYED CABLE
See all 26 reports