NTSB investigations · 1
Matched to this aircraft by N663US and the event date: up to this one’s cancellation.
FAA incident reports · 4
FAA accident and incident reports matched to this aircraft by N663US and the event date: up to this one’s cancellation.
Incident 20121225028449ICruise/Level Flight · Anchorage, AKFrom the statement provided from the crew, the PIC was piloting the aircraft during take-off from atl enroute to nrt. The SIC reported hearing a ?thump? When he raised the gear. Once they raised the flaps, a slight vibration was observed and members of the…Incident 20080214832909IOther Ground Ops · Narita, JA(-23) Flight 1, a B-747-400 operating from Narita, japan to hong kong had a minor fire in the overhead during passenger boarding. After being placed in the overhead bin, a passenger's carry-on baggage caught fire above seats 35B and c. flight attendants on…Incident 19930320011689IFinal Approach-IFR · Detroit, MIStruck runway lights on final approach. Found hole in NR4 engine inlet cowl and fan blade damage.Incident 19910919041729IForced/Precautionary Landing · Narita, JACabin pressure and fire warning on climb out declared emergency. Returned.fire NR2 engine area electic cables arcing
Service difficulty reports · 175
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR DALA2015092505849Attach Fitting · dirtyL1 DOOR SLIDE, WHEN ARMED DOES NOT GO INTO A DESIRED DETENT, BUT INDICATED ARMED ON EICAS SCREEN, THE YELLOW BALL RISES INFLIGHT SO LESS THAN 50 PERCENT OF BALL IS VISIBLE IN WINDOW. REMOVED METAL DEBRIS FROM SLIDE AFT ATTACH FITTING ON FLOOR.SDR DALA2015050303046Battery Pack · inoperativeEMERGENCY LIGHT IN U/D, FWD HALF INOPERATIVE ON SERVICE CHECK. REPLACED BATTERY PACK WITH SERVICEABLE AT M335; CHECKED M312 AND M7052 IAW AMM 33-51. PERFORMED OPERATOR TEST & NORMAL. 7035643.SDR DALA2015043003044Skin · crackedFOUND CRACK AT FS 2370 S-15L. MEASURED CRACK AND TOTAL LENGTH IS 1.3750". REMOVED DAMAGE IAW SRM 53-00-01, REPAIR 1. PERFOMRED HFEC, DAMAGE CONTAINMENT, OF CUTOUT IAW NDT MANUAL 51-00-00, PART 6. PERFORMED BHEC OF EXISTING FASTENERS IAW NDT 51-00-00, PART 6
See all 175 reports