N8076U, cancelled May 17, 2006
Service difficulty reports · 96
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8076U' AND deregistration_id = 'N8076U-2006-05-17' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8076U' AND deregistration_id = 'N8076U-2006-05-17' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA010061Engine · flamed outNR 4 ENGINE IN FLIGHT FLAME OUT 35000. IAW UAL M/M 71-00-40 PGS 201-206 POWER LOSS/FLAME- OUT INVESTIGATED & CHECKED THE FOLLOWING: ENGINE INLET/ EXHAUST, CHIP DETECTORS, MAIN FUEL PUMP, FUEL CTRL.,NR 3 ENGINE FUEL BOOST PUMP, IGNITOR, FUEL QTY CHECKED LINE LSDR RRXA010046Doubler · corrodedDURING FCD A53-4R2 INSPECTION OF LWR FUSELAGE CORROSION. MX DISCOVERED CORROSION BEYOND LIMITS. REMOVED CORROSION , FABRICATED NEW FINGER DOUBLER AND INSTALLED PER EO 01-143 WITH APPROVED 8110-3 DATED 5/12/01.SDR RRXA011040Restrictor Valve · failedON/BEFORE LANDING, WITH LANDING GEAR HANDLE PLACED DOWN, DOORS WARNING LIGHT ON, LANDING GEAR UNSAFE LT MLG GREEN LIGHT NOT ILLUM. ALT DOOR LT LIGHT ON LT GEAR WOULD NOT EXTEND. RAN EMERGENCY CHECKLIST AND PERFORMED EMERGENCY LEFT GEAR UP LANDING. REMOVED ASDR RRXA010013Pressure Switch · inoperativeNR 4 ENGINE LOW OIL PSI LIGHT INOP. TRANSFERRED TO DMI LIST AS CONTROL B-9616122-0962 CAT: B MEL 7906 ATA 7910 DUE DATE 02MAR01 PLACARD INSTALLED. REMOVED AND REPLACED NR 4 ENG LOW OIL PRESS SW, OPS AND LEAK CHECK GOOD IAW DC-8 M/M 79-32-2. (LOW OIL PRESS SSDR RRXA010004Ballast · odorSTRONG SMOKE ODOR COMING FROM FIRST OFFICERS SIDE, SUSPECT LIGHT BALLAST. TRANSFERRED TO DMI LIST AS CONTROL C-9755071-227 CAT: C MEL 3301 ATA 3310 DUE DATE 20JAN01 PLACARD INSTALLED . REMOVED AND REPLACED LIGHTING BALLAST SIX PACK IAW DC-8 M/M 33-10-0. SDR RRXA003683Tire · failedON LANDING TIRES NR 3 & 4 BLEW. REMOVED AND INSPTED AXEL THREADS. REPLACED NR 3 & 4 WHEEL ASSEMBLIES IAW DC-8 MM 32-41-05. FOUND MLG ANTI-SKID INOP, TROUBLESHOT SYSTEM, FOUND BAD ANTI-SKID CONTROL VALVE. REMOVED AND REPLACED CONTROL VALVE IAW DC-8 MM 32-43-3SDR RRXA003138Splice · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ALONG RADIUS OF THE STRESS PANEL ATTACH POINT END SPLICE AT STA Y=780 AND X=-12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-SDR RRXA003312Angle · corrodedDURING A MAINTENANCE VISIT FOUND A DENT TO THE DOOR JAMB FRAME IN C-CARGO COMPT AT STA 1169 AND LBL 14 WATERLINE -58, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-SDR RRXA003131Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SIDE CUSP WEB AT STA 880 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 AND 51-1-21.SDR RRXA003132Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CUSP WEB AT STA 880 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND 53-2-0.SDR RRXA003133Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL AND DOUBLER BETWEEN FLOORBEAMS AT STA 320 - 324 AND X+40 Z-2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRMSDR RRXA003135Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FAIRING ATTACH ANGLE AT STA 640, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-24 AND 51-1-21.SDR RRXA003321Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE TRACK AT FASTENER HOLE AT FS 1482 AND X=50R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 1F. (CORROSSDR RRXA003134Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL BETWEEN STA 1380 - 1400 AND LBL -18 WATERLINE -35, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-24, 5SDR RRXA003136Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BLEED AIR CONNECTOR DOOR LANDING AT THE RT RAM AIR INLET, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR RRXA003329Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RIGHT WHEEL WELL FITTING AT STA 899 AND L23R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0 FIG 1F. (CORROSDR RRXA000427ALongeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE TOP SIDE FRAME AT STA 1080 RBL-48 THROUGH LBL 448 AND ABOVE LONGERON L33.35, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FASDR RRXA003160Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE HEAT VENT ON THE RT WING CENTER L/E INTERIOR AT STA 352, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2SDR RRXA003148Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT STA Y398-428 AND X23-X27, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG F. CORROSION DAMSDR RRXA003146Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE AFT SIDE OF THE NR 3 LEFT SEAT TRACK AT STA 230 - 240 AND LBL 25 - 29, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SSDR RRXA003145Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT STA 190 - 205, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3. CORROSION DAMAGE RECORDED IN ESDR RRXA003314Doubler · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FWD CARGO COMPT DOOR LEFT EDGE EXTERIOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-20D AND PD-05-52-0SDR RRXA003147Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE FITTING INSIDE BOTTOM LIGHTENING HOLE ON THE FWD CARGO NR 2 DOOR CUTOUT AFT JAMB AT STA 565 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICASDR RRXA003328Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE SEAT TRACK FLANGE AT STA 1362 AND X+=45 Z+0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 1F. (CORROSSDR RRXA003327Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT STA 1600 AND X+45 X+44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 1F. (CORROSION DAMSDR RRXA003326Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE SEAT TRACK AT STA 1620 - 1640 AND LT X+44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-0 AND 53-2-3 FIG 1. SDR RRXA003324Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON FRAME SPLICE FWD SIDE OF FRAME AT STA 520 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-1-20D SDR RRXA003319Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT WHEEL WELL FRAME AT STA 879 ABOVE L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-6, 51-1-24 AND 5SDR RRXA003155Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE HOT AIR VENTS ON THE LT WING L/E AT STA 282, 341 AND 285, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EA PD08-57-041.SDR RRXA003152Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT STA 1660-1675 AND X-43 TO X-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 53-2-0 AND 51-1-8 PASDR RRXA003143Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME AT STA 540 AND L29L TO 36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 AND 51-1-21 FIG 1B. CORSDR RRXA003141Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT STA 1660-1680 AND X+44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3 PG 35. CORROSION DAMAGSDR RRXA003130Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON FWD SIDE OF SUPPORT FRAME ON THE LT WING TRAILING EDGE FLAP WELL AT STA XW 27, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8SDR RRXA003129Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN THE RADIUS OF THE RIGHT SIDE KEEL BEAM SUPPORT FITTING AT STA Y+791 X-1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC-8 SRM 51-SDR RRXA003128Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM TOP STRAP AT STA 1580 AND X+30 THROUGH X+43, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SUPPORT IAW DC-8 SRM 51-1-4 ASDR RRXA003325Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME IN THE FWD CARGO COMPT AT STA 600 AND L31L TO L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-2SDR RRXA003320Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON UPPER SIDE OF LONGERON AT STA 500 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-1 FIG 7 AND 53-2-0.SDR RRXA003159Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE HOT AIR VENT ON THE LT WING CENTER L/E AT STA 347 - 354, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EA PD08-57-041.SDR RRXA003158Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE HOT AIR VENT ON THE LT WING CENTER L/E AT STA 366 - 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EA PD08-57-041.SDR RRXA003151Bracket · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE UPPER MOUNTING BRACKET ON THE FWD ACCESSORY COMPT AFT BULKHEAD AT STA 70 X-3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SSDR RRXA003323Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AROUND FASTENERS ON THE LONGERON AT STA 1060 TO 1070 AND L33L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, SDR RRXA003322Strap · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE INTERCOSTAL STRAP OVER FRAME AT STA 1080 ABOVE L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-SDR RRXA003318Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LONGERON AROUND FASTENERS AT STA 1070 TO 1080 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 ASDR RRXA003317Fitting · corrodedDURING A MAINTENANCE VISIT FOUND IG CORROSION DAMAGE TO THE T-ANGLE BELOW FLOOR LEVEL ATTACHED TO SKIN AT STA 920 AND L21R TO L22R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DCSDR RRXA003316Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM AROUND HUCKBOLTS AT STA 920 AND -21-X61 THROUGH -X67, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2SDR RRXA003154Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT WING CENTER L/E INTERIOR HEAT VENT AT STA 302 AND 408, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-0 AND EA PSDR RRXA003153Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT WING CENTER L/E HOT AIR VENT AT STA 419, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-8 AND EAPD08-57-036.SDR RRXA003149Web · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE DOOR WEB AT FWD END OF C-BAGGAGE DOOR AT STA 1172 AND -X10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DSDR RRXA003142Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT FS 1680-1700 AND X=25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3 PG 35. CORROSION DAMAGESDR RRXA003137Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING FOR FRAME TO FUSELAGE FWD SIDE OF FITTING AT STA Y=880 AND L21R-L22R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW