Service difficulty reports · 79
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR FDEA2019060311203Sequence Valve · misaligned6685 ON GEAR EXTENSION RECEIVED UNSAFE INDICATION FOR RT MLG ON SYS 1 SYS 2. COMPLIED WITH QRH PROCEDURES AND LG GRAVITY EXTENSION CHECKLIST. GEAR DOORS REMAINED OPEN, UNEVENTFULL LANDING KLRD. (ON LOW APPROACH, TOWER CONFIRMED RT MLG HUNG UP). TROUBSDR FDEA2018042601120Power Supply · failedEMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY AND BATTERY 29WLI IAW AMM 33-51-14-04-09. OPS CHECKED GOOD.SDR FDEA201705031343Jackscrew · lack of lubeWHEN SELECTING FLAPS TO 15, NOTICE BINDING LEAVING THE SLATS/FLAPS 15/0 GATE AT FLAPS 15 RECEIVED FLAP FAULT SYS 1 AND 2. CYCLED THE FLAP HANDLE, NO CHANGE. QRH PROCDURES COMPLETED. LANDED FLAPS 0. REMOVED AND REPLACED THE FLAP/SLAT HANDLE COMMAND SENS
See all 79 reports