N8085U, cancelled May 17, 2006
Service difficulty reports · 99
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8085U' AND deregistration_id = 'N8085U-2006-05-17' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8085U' AND deregistration_id = 'N8085U-2006-05-17' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA010054Accumulator · failedSPOILER PUMP INOP. FOUND SPOILER ACCUMULATOR BLADDER BLOWN AND SPOILER RESERVIOR EMPTY. REMOVED AND REPLACED SPOILER ACCUMULATOR AND SERVICED SPOILER RESERVOIR IAW MM 29-12-02. SPOILER PUMP OP CK GOOD IAW M/M 27-63-25.SDR RRXA011044Wheel · vibrationAT ROTATION NOSE GEAR VIBRATION FELT AND METALLIC SOUND HEARD. REMOVED AND REPLACED LEFT AND RIGHT NOSE WHEEL ASSY IAW DC8 MM 32-41-10. OPS CHECKS GOOD.SDR RRXA010027Door · malfunctionedLOUD NOISE AND BUFFET FROM NOSE SECTION. RIGHT NOSE LANDING GEAR DOOR IN OPEN POSITION WHEN AIRCRAFT TAXIED IN. INSPECTED NOSE GEAR DOORS FOR CONDITION AND OPERATION NO DEFECTS NOTED. RE-SET POSITION, AIRCRAFT OK FOR FURTHER FLIGHT DC-8 M/M 32-20-00.SDR RRXA010003Adi · malfunctionedCAPTAINS GYRO AND FLIGHT DIRECTOR FLAGS IN VIEW WHEN A/C PITCHES UP OR DOWN 3 DEG AND HORIZON FREEZES IN POSITION. REMOVED AND REPLACED CAPT''S ADI, OPS CKS GOOD IAW UAL MM 41-20 -22.SDR RRXA001096Cover · damagedPRECAUTIONARY SHUTDOWN NR 4 ENGINE, NO OIL QUANTITY OR PRESSURE. FOUND HAND CRANKING PAD COVER DAMAGED AND REPLACED COVER. SERVICED ENG, OIL AND LEAK CHECK NORMAL. INSPECTED CHIP DETECTORS AND OIL FILTERS, NO CONTAMINATION FOUND.SDR RRXA001095Duct · failedCLIMBING THRU 12,000 FEET NR 2 ENGINE FIRE WARNING SOUNDED. SECURED ENGINE PER EWW QRH. UPON INSPECTION OF ENGINE FOUND HIGH STAGE BLEED DUCT CRACKED AT FLEX COUPLING. REMOVED AND REPLACED HIGH STAGE BLEED DUCT IAW DC-8 M/M CH 36-11-61 AND FIRE WARNING CHECSDR RRXA002173Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPARTMENT AFT SIDE OF FRAME AT FS 1340 AND LONGERON 30L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ANGLE IAW DC-SDR RRXA002189Spar Cap · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SPAR CAP IN THE CABIN INT BELOW FLOOR LEVEL AT STA 857 AND RBL 48 THROUGH LBL 48, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED SPARSDR RRXA002187Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FUSELAGE INT ON ATTACH ANGLE AT STA 857 TO 859 AND L11R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-8SDR RRXA002188Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FUSELAGE INT AT STA 857 TO 879 AND L12R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ANGLE ASSY IAW DC-8 SRM 51-1-21D FIG 34 SSDR RRXA002186Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE TOP LT WING AFT OF NR 2 ENGINE CENTER SPAR AT STA 252.351, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW PDO8-57-018.SDR RRXA003434Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING TO THE MAIN CABIN R/S AT STA 440 AND L11R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 53-2SDR RRXA002190Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN R/S AT STA 440 AND L11R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW EA PD 08-53-040 AND SRM 51-2-0.SDR RRXA002185Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN CABIN SEAT TRACK AT STA 840 TO 990 AND RBL 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED TRACK IAW DC-8 SRM 53-2-3 FIG 7.SDR RRXA002184Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CABIN AT STA 1260 TO 1280 AND L11R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-20 FIG 45.SDR RRXA002181Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD CARGO COMPARTMENT AT STA 620 AND L35L TO L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FRAME IAW DC-8 SRM 51-1-0 FIG FSDR RRXA002180Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD CARGO COMPARTMENT FRAME AT STA 560 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED SPLICE IAW DC-8 SRM 53-4-0 FIG 1B.SDR RRXA002182Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CABIN INT BELOW FLOOR LEVEL AT STA 879 AND L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FRAME IAW DC-8 SRM 51-1-20D FIG 1D.SDR RRXA002179Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LT FWD FRAME IN THE COCKPIT AT STA 117, 223 AND 220 30 IN LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FRAME IAW DC-8 SRMSDR RRXA002183Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CABIN INT FLOOR LEVEL AROUND CLIP NUT HOLES AT STA 1000 AND RBL 25 THROUGH 44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW CAPSDR RRXA002178Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD LOWER CARGO COMPARTMENT FRAME AT STA 491 AND LONGERON 29R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FRAME IAW DC-8 SRM 53-4SDR RRXA002177Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPARTMENT AT STA 1420 AND L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW DC-8 SRM 51-20-1 FIG 42 AND 53-SDR RRXA003435Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT SIDE OF FRAME IN THE AFT CARGO COMPT AT FS 1340 AND L30L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IASDR RRXA002176Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPARTMENT AT FS 1500 TO 1520 AND LONGER SPLICE 26R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED SPLICE IAW DC-8 SRM 53SDR RRXA002175Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPARTMENT AT STA 1510 AND L27R TO L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4 AND 51SDR RRXA002174Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPARTMENT IN CENTER ROW OF FASTENERS AT FS 1416 TO 1410 AND L33L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED ISDR RRXA002172Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD CARGO COMPARTMENT DOOR CUTOUT UPPER JAMB RT SIDE SKIN AT STA 284 - 325, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER SDR RRXA002171Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD LOWER CARGO COMPARTMENT AT FS 119 THROUGH 204 AND LONGERON 31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED DOUBLER IAW DC-8 SSDR RRXA002168Clip · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FWD LOWER CARGO COMPARTMENT AT STA 198 AND LONGERON 31 RT TO FRAME CLIP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED CLIP IAW DC-8SDR RRXA002170Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPARTMENT TOP SIDE OF FRAME LEG AT FS 1140, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 FISDR RRXA002169Strap · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT BAGGAGE COMPARTMENT AT FS 1086 - 1100 AND LONGERON 31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW STRAP IAW DC-8 SRM 53-SDR RRXA991289Finger Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FINGER DOUBLER AT LT CUSP LINE STA -32. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER AND FILLER IAW DC8 SRM 53-2-0. (CORROSIONSDR RRXA991032Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, FRAME, FWD PIT AT STA 160, LOWER CAP, BETWEEN LONGERONS 34 RIGHT AND LONGERON 34 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED DOUBLER SDR RRXA991028Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, FRAME, FWD ACCESSORY COMPARTMENT FRAME AT STA 70, BETWEEN LONGERONS 33 LEFT AND LONGERON 31 LEFT, FRAME LOWER CHORD. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SSDR RRXA991036Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, FRAME, BILGE CORROSION UNDER NUT PLATES TOP CAP AND AFT FACE OF WEB FRAME AT STA 1260 BETWEEN LONGERONS 34 LEFT AND LONGERON 34 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATEDSDR RRXA991019Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, LT FRAME STA 1843 TW0 FEET ABOVE HORIZ STAB. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW FAA APPROVED TENNESSEE TSDR RRXA991368Frame · corrosionDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FRAME, AT STA 500, LONGERON 33 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS IAW DC8 SRM 53-2-0 AND 51-1-20. (CORROSDR RRXA991301Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FWD PIT FRAME AT STA 420, BETWEEN LONGERONS 36 AND LONGERON 27 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DSDR RRXA991300Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FWD PIT FRAME AT STA 480, BETWEEN LONGERONS 35 LEFT AND LONGERON 33 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DCSDR RRXA991027Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, UPPER CUSP MEMBRANE, AT STA 560. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED DOUBLERS AND INSTALLED IAW FAA APPROVED TENNESSEE TECH DER ENGISDR RRXA991030Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, BILGE CORROSION FRAME AT STA 1040 BETWEEN LONGERONS 28 LEFT AND LONGERON 33 LEFT AT NUT PLATES. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED SDR RRXA991021Skin · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, SKIN/PLATING, MARKER BEACON ON MOUNTING SKIN BETWEEN STA 640 AND STA 660, BETWEEN LONGERONS 34 LEFT AND LONGERON 34 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DCSDR RRXA991315Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, ENTRANCE AND LAV FLOOR, BETWEEN STA -8.0 AND STA 80. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PANEL SKINS ON 9 EA PANELS IAW DC8 SRSDR RRXA991025Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, FRAME, FWD PIT, AT STA 120, BETWEEN LONGERONS 33 RIGHT AND LONGERON 30 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE DOUBLER AND ISDR RRXA991024Channel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, NOSE COWL CHANNEL 5:30 POSITION AFT SIDE OF CANTED BULKHEAD. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED U CHANNEL IAW FAA APPROVED TENNESSEE SDR RRXA991023Bulkhead · crackedDURING A MAINTENANCE VISIT, FOUND CRACK, CENTER FUSELAGE, SHIELD BULKHEAD, C-PIT FWD BULKHEAD, BENT, CRACKED. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PARTITION AND ATTACH ANGLE IAW FAASDR RRXA991018Skin · damagedDURING A MAINTENANCE VISIT, FOUND SCRAPE, CENTER FUSELAGE, SKIN/PLATE, AT STA 1360, LONGERON 23 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. BLENDED AREA IAW DC8 SRM 51-1-0, TREATED AND PRIMED IAW DC8 SRM 51SDR RRXA991299Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FRAME, BETWEEN STA 280 AND STA 287, AND BETWEEN LONGERONS 28 LEFT AND LONGERON 29 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED RSDR RRXA991026Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, FRAME ATTACH ANGLE, FWD PIT, AT STA 140, LONGERON 31 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ATTACH ANGLE IAW DC8 SRSDR RRXA991033Skin · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, WING, L/E SKIN, UNDER FASTENER RIGHT WING L/E UPPER SURFACE AT STA XFS 13.750 AT FRONT SPAR. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLE
Back to N8085U, cancelled May 17, 2006