N8091U, cancelled Apr 13, 2006
Service difficulty reports · 257
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8091U' AND deregistration_id = 'N8091U-2006-04-13' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8091U' AND deregistration_id = 'N8091U-2006-04-13' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA010045Frame · corrodedCOMPLY WITH FCD A53-4R1 INSPECTION FOR LOWER FUSELAGE CORROSION. INSPECTED LOWER FUSELAGE FOR CORROSION. FOUND CORROSION AT STA 100 L36 LEVEL 2 CORROSION. BLENDED CORROSION, BEYOND LIMITS. AIRCRAFT FERRIED TO TENNESSEE TECHNICAL SERVICES, LLC. INSPECTED TSDR RRXA10771Switch · failedDURING A MAINTENANCE VISIT FOUND UNSAFE LIGHT DAMAGE TO LT MLG UNSAFE LIGHT (RED) STAYS ON & NO L/H MLG GREEN LIGHT AFTER SEVERAL GEAR CYLES, GOT GREEN LIGHT ONLY AFTER STEEP BANKS AT LT. SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATEDSDR RRXA10759Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CENTER FWD. FLOOR PANEL AT COCKPIT PANEL #676, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SDR RRXA10764Stringer · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING STR.53 AT STA. 495 AND AFT HORZ. LEG, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW E.O. #01-SDR RRXA10763Fitting · gougedDURING A MAINTENANCE VISIT FOUND GOUGE DAMAGE TO LT. WING CANOE FITTING AT STA.340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. 01-024 WITH APPROVED 8110-3 DATED 03/23/01SDR RRXA10767Skin · damagedDURING A MAINTENCE VISIT FOUND HOLE DAMAGE TO HORZ STAB RT. ELEVATOR AT STA. XE 228.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. 01-024 WITH APPROVED 8110-3 DATED 02/SDR RRXA10765Door Frame · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO RT. MLG BODY DOOR AT AFT O/B CORNER FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. #01-024 WITH APPROVED 8110-3 DATEDSDR RRXA10760Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LAV. FLOOR PANEL AT STA. 46-66, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4 AND SDR RRXA10766Spar · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BOTTOM OF SPAR AT STA. 781 AND INSIDE L/H CENTER TANK THUR MID-SPAR ACCESS HOLE560E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FSDR RRXA10762Skin · damagedDURING A MAINTENANCE VISIT FOUND HOLE DAMAGE TO TAIL CONE SKIN AT STA.1902 AND RT 14 INCHES O/B AND 8 INCHES AFT OF ACCESS DOOR NR 62, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW PART AND INSTALLESDR RRXA10761Bushing · elongatedDURING A MAINTENANCE VISIT FOUND ELONGATED BUSHING DAMAGE TO #3 LT. FLAP 2ND FROM O/B VANE AT 2ND O/B VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED ISDR RRXA10770Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGED TO A-PIT DOOR SEAL FRAME WORN/CRACKED OUT INCLUDING SKIN--LOC CENTER SECTION OF DOOR AT A-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSSDR RRXA10769Bracket · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO A-PIT DOOR SEAL FRAME AT A-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O 01-024 WITH APPROVED 8110-3 DATED 03/13/01.SDR RRXA10768Skin · gougedDURING A MAINTENANCE VISIT FOUND GOUGED DAMAGE TO A-PIT DOOR SEAL FRAME & DOOR SKIN AT THE A-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. 01-024 WITH APPROVED 8110-3 SDR RRXA10773Skin · tool damageDURING A MAINTENANCE VISIT FOUND TOOLING MARK DAMAGE TO LWR. WING SKIN UPPER SURFACE AT STA. XRS 507.625 AND STR. 54, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. 01-024 WSDR RRXA10861Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BRACKET AT STA. 1140-1160 AND L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20DSDR RRXA10744Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO OUTER SKIN L35L AT STA.705, DAMAGE EXCEEDED LIMITATIONS IAW DC-8SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D. (CORROSSDR RRXA10743Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO L/H STRESS PANEL AT KEEL BEAM, AT STA 740, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4.SDR RRXA10742Fitting · gougedDURING A MAINTENANCE VISIT FOUND GOUGING DAMAGE TO RT. CANOE FITTING TOP FWD 3 INCHES AT RT. STA 340, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. #01-024 WITH APPROVED 811SDR RRXA10860Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FILLET ATTACH HOLES AT STA. 640-610 AND L31L TO L28L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED ISDR RRXA10772Bulkhead · crackedDURING A MAINTENANCE INSPECTION FOUND CRACK DAMAGE TO C & D PIT R/H BULKHEAD AT C & D PIT, DAMAGE EXCEEDS LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW E.O.#01-024 WITSDR RRXA10749Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SKIN AT STA. 772-721 AND L35L-L36R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW EO#01-024 WITHSDR RRXA10748Skin · gougedDURING A MAINTENANCE VISIT FOUND GOUGED AND DENTED DAMAGE TO SKIN AT STA.1890 AND TAIL POST SUPPORT, DAMAGE EXCEEDED LIMITAIONS IAW DC-8 SRM. REMOVED DAMAGE AND TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-2-1 AND DC-8 SRMSDR RRXA10747Skin · damagedDURING A MAINTENANCE VISIT FOUND HOLE DAMAGE TO SKIN AT HOLE 62 AND RUDDER POWER PACK LEDGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND ISTALLED IAW SRM 51-1-4 AND DC-8 SRM 51-1-21.SDR RRXA10746Brace · crackedDURING A MAINTENACE VISIT FOUND CRACK DAMAGE TO HORZ. BRACE AT STA. 1916 AND DOOR 62, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-4 ASDR RRXA10745Skin · damagedDURING A MAINTENANCE VIST FOUND ELONGATED HOLE DAMAGE TO SKIN AT FWD OF MLG DOORS, DAMAGE ECXEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 51-3-0.SDR RRXA10862Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO INTERNAL SKIN LT WW AT STA. 857-879 AND LBL 0-68.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-3-0 & 53-2-0 FISDR RRXA010687Angle · brokenDURING A MAINTENANCE VISIT FOUND THE "C-PIT" ANGLE BROKEN IN HALF (AFT R/H), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4 AND DC-8 SRSDR RRXA010686Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR BEAM SUPPORT FITTING AT STA 300 AND RBL -24", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRSDR RRXA010685Hand Rail · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SIDE RAIL AT STA 90-220 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 AND DC-8 SRM 51-1-4.SDR RRXA010684Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE GALLEY FLOOR PANEL AT TOP SURFACE PANEL #329, DAMAGE EXCEEDED LIMITATIONS IAAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DCSDR RRXA010683Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CUSP LINE PANEL AT STA 1540-1620 L/H, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA010682Structure · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CUSP RAIL AT STA 210-380 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA010681Fitting · crackedDURING A MAINTENANCE VISIT FOUND A 2.5 INCH CRACK INSIDE BATH TUB FITTING LWR HORIZ. SURFACE TO LT LONGERON 24 STA 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53SDR RRXA010680Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FUEL TANK PANEL LAND 506B AT STA XRS 110 TO 125 S-69 TO S-71, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. #01-024SDR RRXA10868Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION TO BATH TUBE FITTING AT STA. 1690 AND L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51SDR RRXA010679Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CENTER WING SKIN AT STA 960-980 X+45", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 & 53-2-0 FIG. 1F.SDR RRXA010678Guard · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN 2 PLACES TO THE R-1 DOOR SILL GUARD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O.#01-024 WITH APPROVED 8110-3 DATED 02/15/01.SDR RRXA010677Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CENTER WING FLOOR BEAM AT STA 857 X+60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW E.O.#01-024 WITH APPROVED 8110-3 DATED 02/26/SDR RRXA010676Flange · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT FWD TYPE I DOOR FRAME SEAL FLANGE LWR END, DAMAGE EXCEEDED LIMITATIONS IAAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND DC-8 SRM 53-2-0SDR RRXA010675Frame · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE FWD SIDE OF FRAME ON THE R/H FWD TYPE I DOOR FRAME SEAL AT STA 370, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-2SDR RRXA010674Floor Panel · misrepairedDURING A MAINTENANCE VISIT FOUND AN IMPROPER REPAIR TO THE MAIN CARGO FLOOR PANEL AT STA 80 TO 340E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND DC-9 SRM SDR RRXA010673Doubler · bentDURING A MAINTENANCE VISIT FOUND A BENT TO THE UPPER FWD CORNER ON THE DOUBLER FOR "A-PIT" CUTOUT AT STA 320-333, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTASDR RRXA010672Doubler · bentDURING A MAINTENANCE VISIT FOUND A BENT UPPER FWD CORNER TO THE DOUBLER FOR "A-PIT" CUTOUT AT STA 292, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DSDR RRXA10507Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED LOCK HOLES ON THE FE'S FWD SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREAIAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA010510Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE EDGES OF THE FLOOR PANEL CAPT'S SIDE PANEL #676D, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA010509Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE COCKPIT FLOOR PANEL #661 AND CRACKED SCREW HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IASDR RRXA010508Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AROUND PERIMETER TOP & BOTTOM EDGES OF CENTER COCKPIT FLOOR PANEL #677 CHAFF STRIP BROKEN, ELONGATED HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IASDR RRXA010506Skin · corrodedDURING A MAINTENANCE VISIT FOUND DISCOLORATION TO THE SKIN ON INSIDE TANK AT LT LWR WING FUEL VENT BOX UPPER SKIN BETWEEN STRINGERS NR 1 & 2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTASDR RRXA10863Door Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ACCESS HOLE 60 DOOR FRAME AT STA. 1793-1766 AND L34L-L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51
Back to N8091U, cancelled Apr 13, 2006