Service difficulty reports · 49
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR AALA006095Duct · leakingLAS - AT APPROXIMATELY 1000 FT ON TAKEOFF, THE TAIL COMPT TEMP HIGH AND MASTER WARNING LIGHT CAME ON. DELAYED 30 SECONDS TO SEE IF LIGHT WOULD GO OUT AND PULLED POWER BACK TO 1.4 EPR. LIGHT STAYED ON. DECLARED AN EMERGENCY AND MADE IMMEDIATE RETURN TO LAS. SDR AALA006085Actuator · malfunctionedSJC - ON CLIMB-OUT AT 9000 FEET, UNCOMMANDED LEFT RUDDER INPUT. QUICKLY ABOUT ONE-THIRD OF FULL TRAVEL. PRIOR TO THAT WITH RUDDER TRIM CENTERED A SIGNIFICANT AMOUNT OF RT AILERON WAS REQUIRED TO FLY WINGS LEVEL. IE AFTER LEFT UNCOMMANDED RUDDER, AIRCRAFT FLSDR AALA006076Battery · inoperativeLAX-CCI - CABIN EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY ON LEFT FORWARD EXIT EMERGENCY LT, EXIT LT AND CABIN EMERGENCY LTS. OPS CHECK OK. (M)