N838CA, cancelled Nov 12, 2020

Service difficulty reports · 58

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N838CA' AND deregistration_id = 'N838CA-2020-11-12'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20170322013Window · detachedEMERGENCY EXIT WINDOW FELL OUT. REINSTALLED THE ANGLE TO INNER WINDOW. INSTALLED THE WINDOW. OPS CHECKED GOOD.Mar 22, 2017 · N838CA · Dhav DHC8311 · Flight Compartment WindowsSDR JJBA20170310008Connector · defectiveSMOKE OBSERVED AT 1CD OVERHEAD LIGHT AND LIGHTS EXTINGUISHED. REPLACED DEFECTIVE CONNECTOR BS2-P2/J2.Mar 10, 2017 · N838CA · Dhav DHC8311 · Light System WiringSDR JJBA20170117014Smoke Detector · false activationLAVATORY SMOKE DETECTOR SOUNDED IN FLIGHT. R & R THE SMOKE DETECTOR.Jan 17, 2017 · N838CA · Dhav DHC8311 · Smoke DetectionSDR JJBA20161202007Fire Loop · failedCREW RECEIVED MASTER WARNING AND CHECK FIRE DETECTOR LIGHTS. RAN CHECKLIST AND DISCOVERED LOOP A ON THE NR 1 ENGINE FAULTED. R & R THE FIRE LOOP A. OPS CHECKED GOOD. NO OTHER DEFECTS NOTED.Dec 2, 2016 · N838CA · Dhav DHC8311 · Fire DetectionSDR JJBA20160805005Battery · dischargedEMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT BATTERIES, OPS CK SATISFACTORY, ADDITIONAL PN 61-0478-11, OFF: SN:9801269, TT:28739.27, TC:37849, CMA0006, TT:13542.33, TC:16061/ H096, TT:34211.33, TC:37303.Aug 5, 2016 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20160719009Sign · inoperativeEMERGENCY EXIT SIGN AT ROW 2 IS INOPERATIVE. R & R THE SIGN. OPS CHECKED GOOD.Jul 19, 2016 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20160531001Smoke Detector · inoperativeWHEN POWER APPLIED, LAVATORY SMOKE ALARM KEEPS BEEPING. R & R LAVATORY SMOKE DETECTOR.May 31, 2016 · N838CA · Dhav DHC8311 · Smoke DetectionSDR JJBA20160511007Power Supply · inoperativeCEILING EMER LIGHTS INOPERATIVE AT 2 & 3. R & R PS2 POWER SUPPLY.May 11, 2016 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20160510006Relay · failedALL OVERHEAD LIGHTS ON THE RT SIDE OF THE CABIN DO NOT ILLUMINATE. SMOKE WAS REPORTED BY THE FLIGHT CREW & MX PERSONNEL. FOUND WIRES & ELEC EQUIP TO BE BURNT. FOUND 3326BS2J2 P2 CONNECTOR BURNED. R & R PLUS & RELAY PN DSC157-1.May 10, 2016 · N838CA · Dhav DHC8311 · Passenger Compartment LightingSDR JJBA20160507004Battery · dischargedOVERHEAD EMER EXIT SIGN INOPERATIVE AT 3 & 7. R & R EMER BATTERIES AT POSITION PS3 & PS4.May 7, 2016 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20160507003Light · inoperativeSEAT 18D UNDERWING EMER EXIT LIGHT WILL NOT ILLUMINATE. R & R EMER LIGHT ASSEMBLY.May 7, 2016 · N838CA · Dhav DCH1CHIPMUNK · Emergency LightingSDR JJBA20160501001Unknown · malfunctionedEMERGENCY LIGHTS FAILED TO ARM ON FIRST TRY. PERFORMED SYS RESET & TESTED SATISFACTORY.May 1, 2016 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20160428017Power Supply · inoperativeTWO CEILING EMER LIGHTS INOPERATIVE IN CEILING & MISSING ONE COVER. R & R EMER LIGHT POWER SUPPLY 3351-PS2. FOUND BROKEN WIRE 3351-17A20-2, SPLICED. ADDITION PART 61-0478-11, SN H106 TSN - 160 CSN - 173.Apr 28, 2016 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20160411013Plate · buckledLADDER PLATE BUCKLED, REPAIRED.Apr 11, 2016 · N838CA · Dhav DHC8311 · Wing Miscellaneous StructureSDR JJBA20160218011Floorbeam · corrodedFORWARD CTR LT FLOORBEAM HAS SIGNS OF CORROSION, STATION X149.0 TO X180.4. R & R FWD COUNTER LT FLOORBEAM.Feb 18, 2016 · N838CA · Dhav DHC8311 · Fuselage Main, Floor BeamSDR JJBA20150822003Connector · disconnectedLAVATORY SMOKE DETECTOR WILL NOT TEST. FOUND CONNECTOR LOOSE.Aug 22, 2015 · N838CA · Dhav DHC8202 · Fire Protection System WiringSDR JJBA20150701013Hydraulic Line · damagedAT 100 FT HYD CAUTION LIGHT ILLUMINATED. UPON LANDING THE NOSE WHEEL STEERING FAILED, THEN LOST ALL HYD QTY FROM NR 2 HYD SYS. R & R NLG DOWNLOCK ACTUATOR, DOWN PRESS HOSE, BLEED THE NR 2 HYD SYS.Jun 30, 2015 · N838CA · Dhav DHC8202 · Hydraulic System, MainSDR JJBA20150505005Engine · shutdownNUMBER 2 ENG SHUTDOWN UNCOMMANDED ON TAKEOFF ROLL. R & R NR 2 ENG.May 5, 2015 · N838CA · Dhav DHC8311 · Engine (Turbine/Turboprop)SDR JJBA20150329018Battery · defectiveONE OVERHEAD EMER LIGHT INOPERABLE & THE RT SIDE EMER EXIT LIGHT INOPERABLE. SWAPPED EMER BATTERIES PS1 & PS2.Mar 29, 2015 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20150304007Ecu · faultyNUMBER 1 ENG DOES NOT PRODUCE MORE THAN 75% TORQUE ON TAKEOFF. R & R NR 1 ECU.Mar 4, 2015 · N838CA · Dhav DHC8311 · Fuel Control/Turbine EnginesSDR JJBA20150216003Test Switch · out of alignmentLAVATORY SMOKE DETECTOR WILL NOT TEST. FOUND TEST BUTTON OUT OF ALIGNMENT, REALIGNED BUTTON.Feb 16, 2015 · N838CA · Dhav DHC8311 · Smoke DetectionSDR JJBA20140827009Connector · not seatedEMERGENCY LIGHTS DO NOT COME ON. RESEATED PLUG TO FLIGHT ATTENDANT EMER PUSH BUTTON. OPERATIONAL CHECKED SATISFACTORY.Aug 27, 2014 · N838CA · Dhav DHC8311 · Light System WiringSDR JJBA20140718020Transmitter · faultyNUMBER 2 OIL PRESS FLUX IN FLIGHT 0-35PSI. NO WARNING LIGHT NOTED. R & R NR 2 ENG OIL PRESS TRANSMITTER.Jul 18, 2014 · N838CA · Dhav DHC8311 · Engine Oil PressureSDR JJBA20140708017Tire · burstNUMBER 3 MAIN TIRE BURST ON TAKEOFF. R & R NR 3 & NR 4 MAIN WHEEL ASSEMBLIES.Jul 8, 2014 · N838CA · Dhav DHC8311 · TireSDR JJBA20140703013Wire · looseCABIN EMER LIGHTS CAME ON IN FLIGHT. REPAIRED LOOSE WIRE ON FLIGHT ATTENDANT PANEL SWITCH.Jul 3, 2014 · N838CA · Dhav DHC8311 · Light System WiringSDR JJBA20140622011Unknown · malfunctionedNUMBER 2 PROP DID NOT COME OUT OF 900 RPM WHEN CREW TRIED TO INCREASE TO 1200 RPM ON LANDING. GND RAN ACFT, INSPECTED NR 2 ENG PUSHRODS TO PCU & NO DEFECTS FOUND. OCF REQUIRED.Jun 22, 2014 · N838CA · Bombdr DHC8400 · Propeller Indication SystemSDR JJBA20140515007Sign · misinstalledOVERHEAD EXIT SIGN ABOVE ROW 18 BACKWARDS. REMOVED & INSTALLED PROPERLY.May 15, 2014 · N838CA · Dhav DHC8311 · Placards and MarkingsSDR JJBA20140327014Pcu · malfunctionedCONDITION LEVER AT MAX, POWER LEVER BROUGHT TO FLIGHT IDLE, THE NR 1 RPM DROPPED FROM 789 TO 650 THEN WENT BACK UP. R & R NR 1 PCU.Mar 27, 2014 · N838CA · Dhav DHC8311 · Propeller Controlling SystemSDR JJBA20140327013Unknown · malfunctionedNR 1 ENG PROP WENT TO FEATHER BY ITSELF WHEN THE POWER LEVER WAS MOVED FROM DISC TO FLIGHT IDLE. INSPECTED RIGGING, OPERATIONAL CHECKED NORMAL. OCF REQUIRED & FAILED.Mar 27, 2014 · N838CA · Dhav DHC8311 · Propeller Feathering/ReversingSDR JJBA20140324012Pump · malfunctionedON CLIMB OUT NR 1 ENG TORQUE SURGED BETWEEN 70 & 100% THEN SHUT DOWN. R & R NR 1 HP FUEL PUMP & MFC. R & R NR 1 TSCU.Mar 24, 2014 · N838CA · Dhav DHC8311 · Engine Fuel PumpSDR JJBA20140320011Battery · dischargedEMERGENCY LIGHTS WILL NOT TEST OR TURN ON. R & R ALL SIX BATTERIES.Mar 20, 2014 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20140311006Indicator · faultyNUMBER 1 ENG OIL PRESS STUCK AT 70 PSI. REMOVED WASHER FROM OIL PRESS REGULATOR. OPERATIONAL CHECK FAILED. R & R NR 1 OIL PRESS GAUGE.Mar 11, 2014 · N838CA · Dhav DHC8311 · Engine Oil PressureSDR JJBA20140223011Placard · missingEMERGENCY EXIT LIGHT AT SEAT 18A PLACARD MISSING. FOUND & RE-INSTALLED PLACARD.Feb 23, 2014 · N838CA · Dhav DHC8311 · Placards and MarkingsSDR JJBA20140222010Battery · dischargedEMERGENCY LIGHTS INOPERABLE. R & R ALL EMERGENCY BATTERIES.Feb 22, 2014 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20140218009Sign · inoperativeLEFT HAND EMERGENCY EXIT DOOR BOTTOM HORIZONTAL EXIT SIGN MULTIPLE LIGHTS INOPERABLE. R & R EXIT SIGN IRW DASH 300 20-45-07.Feb 18, 2014 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20131224005Light · missingFILTER MISSING IAW LT CABIN LOWER EMERGENCY PLACARD LIGHT. REMOVED LT LOWER CABIN EMERGENCY EXIT LIGHT & SPLICED IN NEW EXIT LIGHT ASSEMBLY IRW DH8 Q300 20-45-07.Dec 24, 2013 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20131117008Irs · malfunctionedIRS ALIGN LIGHT INOPERATIVE. R & R IRS CONTROL. OPS CHECKED GOOD.Nov 17, 2013 · N838CA · Dhav DHC8311 · Standard Practices/StructuresSDR JJBA20130822012Switch · failedCABIN PACK HOT LIGHT ILLUMINATED IN FLIGHT. R & R OVERTEMP SWITCH ON CABIN ACM. OPS CHECKED SATISFACTORY.Aug 22, 2013 · N838CA · Dhav DHC8311 · Cabin Cooling SystemSDR JJBA20130703005Connector · looseFORWARD CEILING EMERGENCY LIGHTS INOPERATIVE. MX SECURED CONNECTOR IAW AMM, OPS CHECKED SATISFACTORY.Jul 3, 2013 · N838CA · Dhav DHC8311 · Light System WiringSDR JJBA20130602022Battery Pack · dischargedCREW REPORTED THAT 1 EMERGENCY FLOOR LIGHT WAS INOPERATIVE. THE BATTERIES WERE ALLOWED TO CHARGE AND ALL OPERATIONAL TEST WERE SATISFACTORY.Jun 2, 2013 · N838CA · Dhav DHC8311 · Emergency LightingSDR JJBA20130424012Light · inoperativeCREW REPORTED THAT THE ROW 1 AFT RED EMERGENCY FLOOR PATH LIGHT WAS INOPERATIVE. MX REPLACED THE EMERGENCY LIGHT STRIP.Apr 24, 2013 · N838CA · Dhav DHC8202 · Emergency LightingSDR JJBA20130410004Unknown · smokeCREW REPORTED THAT DURING TAXI SMOKE WAS DETECTED IN THE CABIN. GROUND MX CREW RAN BOTH ENGINES INDEPENDENTLY AND TOGETHER WITH INDEPENDENT ACM'S FOR OVER 40 MINUTES WITH NO SMOKE OR ANY OTHER ISSUE.Apr 10, 2013 · N838CA · Dhav DHC8311 · Air Distribution SystemSDR JJBA201303060001Acm · inoperativeCREW REPORTED A "BURNING DUST" ODOR DURING TAKEOFF THAT DISSIPATED WHEN THE CABIN HEAT WAS TURNED DOWN. AFTER TAKEOFF, CREW OBSERVED A STRONG MELTING PLASTIC ODOR IN THE COCKPIT AND CABIN. THE CREW RETURNED TO FIELD AND DECLARED AN EMERGENCY. ACFT LANDED WMar 6, 2013 · N838CA · Dhav DHC8311 · Cabin Cooling SystemSDR JJBA20130106002Connector · unsecureDURING PRE-FLIGHT INSPECTION, CREW NOTICED A SECTION OF THE FLOOR EMERGENCY LIGHTING WAS NOT ILLUMINATING. MX DISCONNECTED AND RECONNECTED THE CONNECTOR FOR THE LIGHT STRIP. ALL OPS CHECKS PRODUCED SATISFACTORY RESULTS AND THE ACFT WAS RETURNED TO SERVICE.Jan 6, 2013 · N838CA · Dhav DHC8311 · Light System WiringSDR JJBA20121124008Fuel Filter · warning lightCREW REPORTED THAT THE NR 2 FUEL FILTER BYPASS LIGHT ILLUMINATED IN FLIGHT. CREW DECLARED AN EMERGENCY DUE TO COMMUNICATION ISSUES IN COMBINATION WITH THE BYPASS LIGHT. ACFT FINISHED OUT THE FLIGHT WITHOUT FURTHER INCIDENT. GROUND MX CREW R & R THE HP FUEL Nov 24, 2012 · N838CA · Dhav DHC8311 · Engine Fuel DistributionSDR JJBA20120704003Battery Pack · dischargedDURING PRE-FLIGHT, CREW NOTICED SEVERAL EMERGENCY LIGHTS WERE INOPERATIVE. MX RECHARGED THE EMERGENCY LIGHT BATTERIES. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AFTER BATTERIES HAD CHARGED. THE ACFT WAS RELEASED TO SERVICE.Jul 4, 2012 · N838CA · Dhav DHC8301 · Emergency LightingSDR JJBA20120418005Acm · smokeDURING TAXI, NOTICED APPEARANCE OF SMOKE IN COCKPIT. RETURNED TO GATE. INSPECTED AND FOUNG NR 2 ACM CAUSING THE SMOKE. OPENApr 18, 2012 · N838CA · Dhav DHC8311 · Cabin Cooling SystemSDR JJBA20110919001AConnector · damagedFLIGHT CREW REPORTED THAT THE BAGGAGE SMOKE DETECTOR WARNING ILLUMINATED IN FLIGHT. MX R & R A BROKEN PIN ON THE CONNECTOR PLUG. PERFORMED OPS CHECK SATISFACTORY.Sep 19, 2011 · N838CA · Dhav DHC8202 · Fire Protection System WiringSDR JJBA20110909001Smoke Detector · false indicationFLIGHT CREW REPORTED SMOKE WARNING LIGHT ILLUMINATED IN FLIGHT. MX R & R THE NR 2 SMOKE DETECTOR, PERFORMED OPS CHECK SATISFACTORY.Sep 9, 2011 · N838CA · Dhav DHC8311 · Smoke DetectionSDR JJBA20110908001Battery Pack · dischargedFLIGHT CREW REPORTED THAT THERE ARE A FEW EMERGENCY LIGHTS THAT DO NOT TEST. MX CREW ALLOWED BATTERIES TO RECHARGE AND PERFORMED OPS CHECK WITH NO DEFECTS NOTED.Sep 8, 2011 · N838CA · Dhav DHC8311 · Emergency Lighting
Back to N838CA, cancelled Nov 12, 2020