SDR SWIA2019090446259Transmitter · failedENROUTE HYD CAUTION 1B AND 2B DISPLAYED. EMERGENCY DECLARED. QRH FOLLOWED. MSGS CLEARED. (FLT#5675) CLOSED REMOVED AND REPLACED RT FLAP POSITION TRANSMITTER IAW AMM. RAN OPERATIONAL TEST OF ACMP IAW AMM TO VERIFY THE CORRECT ACTION WITH HYDRAULICS AND FLAP POSSDR ASOA2018121465343Skin · dentedREF: CO# 7476718 JOB# 7747675 OP# 62: FUSELAGE SKIN REPAIR REQUIRED BELOW CARGO DOOR BETWEEN FS 605.0 TO FS 625.0 AND STR 18L TO 22L. C/A: PERFORMED PERMANENT REPAIR I.A.W. EXPRESSSJET ECTC REO 601R-53-61-6789.SDR ASOA2018121435341Skin · corrodedREF: CO# 7476718 JOB# 7747675 OP# 57 LOWER WING PLANK CUTOUT FOR RH BOOST PUMP HAS MULTIPLE INDICATIONS NOTED AROUND ENTIRE CIRCUMFERENCE ON HORZ AND VERTICAL SURFACE 50% FSH. FAILED NDT INSP. C/A: PERFORMED MAJOR REPAIR CARD NO: REO 601R-57-21-2908 BLENDED TO