FAA incident reports · 1
FAA accident and incident reports matched to this aircraft by N892US and the event date: up to this one’s cancellation.
Service difficulty reports · 10
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR USAAF01078Coalescer Bag · contaminatedRDU-CLT - FLT 487 - SHORTLY AFTER TAKEOFF, THE RIGHT LAVATORY SMOKE DETECTOR ACTIVATED. 30 SECONDS LATER THE LEFT LAVATORY SMOKE DETECTOR ALSO ACTIVATED. THE AIRCRAFT RETURNED TO THE FIELD AND LANDED WITHOUT INCIDENT. BOTH SMOKE DETECTOR ALARMS STOPPED BEFOSDR USAAF00062Battery Pack · dischargedDCA - FOUND THE EMERGENCY LIGHTS INOPERATIVE IN RIGHT LAVATORY AND LAST TWO CEILING POSITIONS. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY IN POSITION EIGHT. OPS CHECK GOOD. (M)SDR USAAF99011Strut · req'd servicePIT - FLT 2160 - AFTER TAKEOFF FROM PIT THE FOLLOWING MESSAGES APPEARED ON THE MULTI FUNCTION DISPLAY UNIT, GND/FLT CTL, TO WARN CONFIG, STAB WARN. FLIGHT CREW DECIDED TO RETURN TO PIT TO HAVE MAINTENANCE LOOK AT THE AIRCRAFT. FLIGHT LANDED PIT WITHOUT FURTHSDR USAAF97104Battery Charger · failedMAINTENANCE FOUND THE FOLLOWING EMERGENCY LIGHTS INOPERATIVE. LEFT AND RIGHT WING FAIRING AND AFT WINDOW EMERGENCY LIGHTS. REPLACED NR 6 AND NR 7 BATTERY PACK AND NR 6 BATTERY PACK CHARGER. (M)SDR 98ZZZM140Battery Pack · dischargedMAINTENANCE FOUND THE FOLLOWING EMERGENCY LIGHTS INOPERATIVE. LEFT AND RIGHT WING FAIRING AND AFT WINDOW EMERGENCY LIGHTS. REPLACED NR 6 AND NR 7 BATTERY PACK AND NR 6 BATTERY PACK CHARGER. (M)SDR USAAF97101Inverter · failedIND - MAINTENANCE FOUND THE FLOOR LEVEL EMERGENCY EXIT LIGHTING INOPERATIVE BETWEEN ROWS 15 AND THE REAR OF THE AIRCRAFT. THEY REPLACED THE INVERTER. (X)SDR USAAF96049Air Cond Pack · failedCHA - FLT 1421 - CREW HEARD A RUMBLING NOISE FROM RIGHT PACK EN ROUTE TO MSY. FIFTEEN MINUTES AFTER NOISE, SMOKE ALARMS WENT OFF. CREW SHUT PACK OFF, DECLARED AN EMERGENCY AND DIVERTED TO CHA. THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND TSDR USAA960204Floor Beam · corrodedPIT - DURING SCHEDULED CORROSION TRACK VISIT FOUND A CORRODED AREA 1 INCH BY 1.5 INCH AT BL 0 TOP T-EXTRUSION STATION 5305 FLOOR BEAM. REMOVED T-EXTRUSION FROM FORWARD FACTORY SPLICE OF FLOOR BEAM. INSTALLED NEW SECTION ANS SPLICED AFT END WITH 2 EACH DOUBLESDR USAAF95004Eel Inverter · failedORF - MTC DISCREPANCY, EMERGENCY FLOOR LIGHTING INOP ROW 16. REPLACED INVERTER. (M)SDR USAA950919Eel Battery Pack · failedCLT - FLT NR 2416 - EXTERIOR EMERGENCY LIGHTS INOP. ISOLATED TO BATTERY PACK SUPPLYING THE AFT EXTERIOR LIGHTS. PRECAUTIONARY PROCEDURE TAKEN, MEL'D SYSTEM. REPLACED BATTERY PACK. (M)