N916FR, cancelled Apr 13, 2009
Service difficulty reports · 48
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N916FR' AND deregistration_id = 'N916FR-2009-04-13' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N916FR' AND deregistration_id = 'N916FR-2009-04-13' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200800196Lamp · burned outDURING C4 S1 C CHECK INSPECTION NOTED LIGHT OUT IN AFT LEFT OVERWING EXIT. MAINTENANCE REMOVED AND REPLACED LAMP IN AFT LEFT EMERGENCY OVERWING LIGHT 63WL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 33-51-15-000-001 AND AMM 33-51-15-400-001. UPON COMPLETION OSDR F3LA200800195Bracket · corrodedDURING C4 S1 C CHECK INSPECTION NOTED L2 DOOR SLIDE UPPER AFT MOUNT BRACKET HAD CORROSION. MAINTENANCE REMOVED AND REPLACED L2 DOOR SLIDE UPPER AFT MOUNT BRACKET IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECSDR F3LA200800194Bracket · corrodedDURING C4 S1 C CHECK INSPECTION NOTED R2 DOOR SLIDE UPPER AFT MOUNT BRACKET HAD CORROSION. MAINTENANCE REMOVED AND REPLACED R2 DOOR SLIDE UPPER AFT MOUNT BRACKET IN ACCORDANCE WITH SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTSDR F3LA200800183Seat · corrodedDURING C4 S1 C CHECK INSPECTION NOTED CORROSION AT MOUNTING HOLES AFT LEFT FLIGHT ATTENDANT SEAT. MAINTENANCE REMOVED AND REPLACED AFT LEFT FLIGHT ATTENDANT SEAT IN ACCORDANCE WITH THE REQUIRMENTS OF AMM 25-22-41-400-011. UPON COMPLETION OF THE REPAIR IT WASSDR F3LA200800191Floorboard · puncturedDURING C4 S1 C CHECK INSPECTION NOTED FORWARD GALLEY FLOORBOARD 222EF HAS TWO PUNCTURES IN TOP RIGHT EDGE OF FLOORBOARD. MAINTENANCE REPAIRED PUNCTURES IN GALLEY FLOORBOARD 222EF IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 53-12-00 PAGE 205 AND PAGE 206. MAINSDR F3LA200800189Floor Panel · damagedDURING C4 S1 C CHECK INSPECTION NOTED FLOOR PANEL 232MF HAS HOLE IN FACE 1/4 INCH DIAMETER, 3 INCHES FROM INBOARD EDGE AND 3 FEET FROM FORWARD EDGE. MAINTENANCE REPAIRED DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 53-02-00 PAGE 205 FIGURE 201. UPON COMSDR F3LA200800188Fitting · corrodedDURING C4 S1 C CHECK INSPECTION NOTED GIRT BAR FITTING WAS REMOVED ON R1 DOOR DUE TO CORROSION UNDER SPACERS. MAINTENANCE FABRICATED NEW NUT CLIP PLATES IN ACCORDANCE WITH THE REQUIREMENTS OF AIRBUS DRAWING D53112534. MAINTENANCE INSTALLED NEW DRAIN PANS ANDSDR F3LA200800202Support Fitting · corrodedDURING C4 S1 C CHECK INSPECTION, NOTED CENTER FLOORBEAM SUPPORT FITTING BETWEEN C59 AND C60 CORRODED. MAINTENANCE REMOVED CORROSION ON SUPPORT FITTING AND REINSTALLED SUPPORT FITTING AND CENTER FLOORBEAM IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11 ANDSDR F3LA200800163Floor Panel · delaminatedDURING C4 S1 C CHECK INSPECTION REPORTED FLOOR PANEL 261CG HAD DELAMINATION FROM ONE SCREW HOLE. MAINTENANCE REPAIRED FLOOR PANEL 261CG IN ACCORDANCE WITH SRM 53-08-00 STEP 8J, SRM 51-77-11 PARAGRAPH A11 AND SRM 51-44-21 PARAGRAPH 3A. UPON COMPLETION OF THE SDR F3LA200800162Floorbeam · corrodedDURING C4 S1 C CHECK INSPECTION REPORTED CORROSION WAS FOUND ON NUT CLIP HOLE FLOORBEAM Y1292 AT FRAME 67 AND WAS FOUND UNSERVICEABLE. MAINTENANCE REMOVED AND REPLACED FLOORBEAM Y1292 AT FRAME 67 IN ACCORDANCE WITH SRM 51-42-11 PARAGRAPHS 5 AND 7 AND AIRBUS DSDR F3LA200800161Floor Support · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION AT NUT PLATES FWD CARGO PIT RIGHT SIDE FLOOR SUPPORT PLATE FRAME 28 TO FRAME 31. MAINTENANCE REMOVED AND REPLACED SUPPORT PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11. UPON COMPLETION OF TSDR F3LA200800160Floor Support · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE AFT BULKHEAD FLOOR SUPPORT PLATE, IN THE FORWARD CARGO PIT, AT FRAME 31, BETWEEN STRINGERS 38 LEFT AND 38 RIGHT. MAINTENANCE REMOVED AND REPLACED THE PLATE IN ACCORDANCE WITH THE REQUIREMENTSDR F3LA200800159Floor Support · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND AROUND THE NUT PLATE HOLES OF THE FLOOR SUPPORT PLATE ON THE LEFT SIDE OF THE FORWARD CARGO COMPARTMENT BETWEEN FRAMES 28 TO 30. MAINTENANCE REMOVED AND REPLACED THE FLOOR PLATE IN ACCORDANCE WITH SDR F3LA200800158Dummy Rail · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON DUMMY RAIL Y503.2 AT FRAME 16. MAINTENANCE REMOVED AND REPLACED THE DUMMY RAIL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11. UPON COMPLETION OF THE INSTALLATION, THE NEW DUMMY RAIL SDR F3LA200800157Floor Support · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON FLOOR SUPPORT-Y1292, BETWEEN FRAMES 16 AND 20. MAINTENANCE REMOVED AND REPLACED THE CORRODED FLOORBEAM IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11 AND A319 SRM 51-72-11. UPON COMPLSDR F3LA200800190Floorbeam · corrodedDURING C4 S1 C CHECK INSPECTION NOTED CORROSION AT NUT PLATES AFT PIT LEFT FLOORBEAM UNDER COVER PROFILE AT FRAME 56 LOCATED FROM STRINGER 38 LEFT TO 38 RIGHT. MAINTENANCE FABRICATED REPLACEMENT PART IN ACCORDANCE WITH THE REQUIREMENTS OF AIRBUS DRAWING D5347SDR F3LA200800185Floorbeam · corrodedDURING C4 S1 C CHECK INSPECTION NOTED CORROSION AT NUT PLATES AFT PIT LEFT HAND FLOORBEAM UNDER COVER PROFILE AT FRAME 58 LOCATED FROM STRINGER 38 LEFT TO 38 RIGHT. MAINTENANCE FABRICATED AND REPLACED FLOORBEAM SUPPORT FITTING IN ACCORDANCE WITH THE REQUIREMESDR F3LA200800184Mount · corrodedDURING C4 S1 C CHECK INSPECTION NOTED RIGHT WIND SCREEN LOWER ATTACH MOUNTS WERE CORRODED. MAINTENANCE REMOVED AND REPLACED RIGHT WINDSCREEN LOWER ATTACH MOUNTS IN ACCORDANCE WITH THE REQUIRMENTS OF WORK CARD CP725-18. UPON COMPLETION OF THE REPAIR IT WAS INSDR F3LA200800173Fitting · corrodedDURING C4 S1 C CHECK INSPECTION NOTED R2 FORWARD GIRT BAR FITTING PLATE CORODDED IN SEVERAL PLACES. MAINTENANCE REMOVED AND REPLACED FITTING PLATE. OKAY TO INSTALL AND INSTALL WILL BE ACCOMPLISHED ON WORK CARD CP753-36.SDR F3LA200800171Fitting · corrodedDURING C4 S1 C CHECK INSPECTION NOTED R1 FORWARD GIRT BAR FITTING PLATE WAS CORRODED IN SEVERAL PLACES. MAINTENANCE REMOVED AND REPLACED FITTING PLATE. OKAY TO INSTALL AND INSTALL WILL BE ACCOMPLISHED ON WORK CARD CP7553-12.SDR F3LA200800198Support · corrodedDURING C4 S1 C CHECK INSPECTION NOTED FRAME 59 COVER PROFILE NUT PLATE HOLES WERE CORRODED FROM STRINGER 38 RIGHT TO 38 LEFT. MAINTENANCE BLENDED OUT CORROSION AND INSTALLED NEW SUPPORT AT FRAME 59 STRINGER 41 LEFT IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 5SDR F3LA200800152Plate · crackedDURING C4 S1 C CHECK, INSPECTION REPORTED A CRACK WAS FOUND IN THE MOULLION PLATE LOCATED AFT OF THE L2 DOOR FRAME AT THE JOINT SHEET ATTACH POINT. MAINTENANCE REMOVED AND REPLACED THE MOULLION PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11, PSDR F3LA200800203Floor Panel · delaminatedDURING C4 S1 C CHECK INSPECTION NOTED FLOOR PANEL 222EF DELAMINATED AT EDGE. MAINTENANCE REPAIRED FLOOR PANEL 222EF IN ACCORDANCE WITH THE REQUIREMENTS OF EA A9-53R-30217 AND SRM 53-02-00. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800201Floorbeam · corrodedDURING C4 S1 C CHECK INSPECTION NOTED AFT CARGO PIT CENTER FLOORBEAM BETWEEN C58 AND C59 NUT PLATES HAVE SIGNS OF CORROSION. MAINTENANCE REMOVED OLD FLOORBEAM AND REPAIR ANGLES, FABRICATED NEW FLOORBEAM AND REPAIR ANGLES IN ACCORDANCE WITH THE REQUIREMENTS OFSDR F3LA200800187Floor Panel · corrodedDURING C4 S1 C CHECK INSPECTION NOTED FLOOR PANEL 221PF LAV A HAS CORROSION ON BOLT HOLES. MAINTENANCE RECEIVED NEW FLOOR PANEL 221PK, OKAY TO INSTALL AND INSTALL WILL BE ACCOMPLISHED ON ROUTINE CARD CP753-12.SDR F3LA200800186Strip · corrodedDURING C4 S1 C CHECK INSPECTION NOTED BOTH LEFT 1 AND RIGHT 1 GAP STRIPS CORRODED ON LOWER SURFACE. MAINTENANCE REMOVED AND REPLACED LEFT 1 AND RIGHT 1 GAP STRIPS IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-12-12 PAGE BREAK 401. UPON COMPLETION OF THE REPASDR F3LA200800172Floor Support · corrodedDURING C4 S1 C CHECK INSPECTION NOTED CORROSION AROUND NUT PLATES AFT CARGO PIT FLOOR PROFILE BETWEEN C55 AND C56. MAINTENANCE CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR DOUBLER IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-35-00 AND SRM 51-42-11 PSDR F3LA200800178Profile · corrodedDURING C4 S1 C CHECK INSPECTION NOTED CORROSION AROUND NUT PLATES AFT CARGO PIT LEFT FLOOR PROFILE AT C 58. MAINTENANCE REMOVED AND REPLACED PROFILE IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11 PARAGRAPH 5 AND 6 AND AIRBUS DRAWING D53476318. UPON COMPSDR F3LA200800177Floorbeam · corrodedDURING C4 S1 C CHECK INSPECTION REPORTED NUT PLATE CORRODED OUTBOARD OF CENTER FLOORBEAM AFT CARGO PIT C 56 1. MAINTENANCE REMOVED AND REPLACED NEW C 56 PROFILE PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11 PARAGRAPH 6 AND AIRBUS DRAWING 17D539749SDR F3LA200800174Floorbeam · corrodedDURING C4 S1 C CHECK INSPECTION REPORTED FLOORBEAM Y1292 SHOWS SIGNS OF CORROSION AT FRAME 16. MAINTENANCE REPLACED ONE SECTION OF THE BEAM IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11 AND BLENDED OTHER AREA LOCATED AT 62.875" AFT OF FWD END OF BEAM ISDR F3LA200800136Dummy Rail · corrodedDURING C4 S1 C-CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON DUMMY RAIL Y503.2 AT FRAME 16. MAINTENANCE REMOVED AND REPLACED DUMMY RAIL IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11. UPON COMPLETION OF THE INSTALLATION THE NEW RAIL WAS INSPECTED ANSDR F3LA200800199Floor Panel · delaminatedDURING C4 S1 C CHECK INSPECTION NOTED FLOOR PANEL 261HG HAS DELAMINATION AROUND EDGES. MAINTENANCE REPAIRED FLOOR PANEL 261HG IN ACCORDANCE WITH THE REQUIREMENTS OF EA A9-53R-30226. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800156Floor Panel · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE UNDERSIDE OF FLOOR PANEL 222FF. MAINTENANCE REMOVED THE CORRODED PANEL. THE NEW PANEL WAS INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF TASK CARD CP 753-12. UPON COMPLETION OF THE INSTASDR F3LA200800155Floor Panel · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE UNDERSIDE OF FLOOR PANEL 221FF. MAINTENANCE REMOVED CORRODED PANEL. THE NEW PANEL WAS INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF TASK CARD CP 753-12. FOLLOWING INSTALLATION OF THE NESDR F3LA200800204Sill · corrodedDURING C4 S1 C CHECK INSPECTION NOTED R2 DOOR SILL HAS CORROSION AROUND NUT CLIP HOLE AT FRAME 66. MAINTENANCE FABRICATED REPAIR ANGLE IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 53-41-14, FABRICATED LEFT AND RIGHT REPAIR ANGLES IN ACCORDANCE WITH THE REQUIREMSDR F3LA200800154Floor Panel · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THREE INSERTS ON FLOOR PANEL 261PF. MAINTENANCE REMOVED THE CORRODED PANEL. THE NEW PANEL WAS INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF TASK CARD CP 753-36. FOLLOWING THE INSTALLATION OSDR F3LA200800153Floorbeam · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE FORWARD LAVATORY FLOOR ANGLE BRACKET, ON ITS UNDERSIDE. MAINTENANCE REMOVED AND REPLACED THE ANGLE BRACKET IN ACCORDANCE WITH THE REQUIREMENTS OF A0-25EO-20299. UPON COMPETION OF THE REPLACSDR F3LA200800151Floor Support · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND AROUND THE NUT CLIP HOLES ON FLOOR BEAM Y1292 BETWEEN FRAMES 68 AND 69. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11, PARAGRAPH 6. UPON CSDR F3LA200800140Shear Plate · corrodedDURING C4 S1 CHECK INSPECTION REPORTED CORROSION WAS FOUND ON SHEAR PLATE AT FLOORBEAM Y1732 AFT OF FRAME 69. MAINTENANCE REMOVED AND REPLACED SHEAR PLATE IN ACCORDANCE WITH SRM 51-42-1 PARAGRAPH 6, 7 AND EA A9-53R-30196. UPON COMPLETION OF THE INSTALLATION SDR F3LA200800139Shear Plate · corrodedDURING C4 S1 C-CHECK INSPECTION REPORTED CORROSION WAS FOUND ON SHEAR PLATE AT FLOORBEAM Y1732 AFT OF FRAME 69. MAINTENANCE REMOVED AND REPLACE SHEAR PLATE IN ACCORDANCE WITH SRM 51-42-11 PARAGRAPH 6, 7, 13 AND EA A9-53R-30196. UPON COMPLETION OF THE INSTALLSDR F3LA200800138Support · corrodedDURING C4 S1 C-CHECK, INSPECTION REPORTED CORROSION WAS FOUND AT FRAME SUPPORT OF FLOORBEAM Y1732 AFT OF FRAME 69. MAINTENANCE REMOVED AND REPLACED FRAME SUPPORT IN ACCORDANCE WITH SRM 51-42-11 PARAGRAPH 6, 7 AND 14 AND EA A9-53R-30196. UPON COMPLETION OF THESDR F3LA200800137Support · corrodedDURING C4 S1 C-CHECK, INSPECTION REPORTED CORROSION WAS FOUND AT FRAME SUPPORT OF FLOORBEAM Y1732 AFT OF FRAME 69. MAINTENANCE REMOVED AND REPLACED FRAME SUPPORT IN ACCORDANCE WITH SRM 51-42-11 AND SRM 51-72-11 AND SRM 51-44-11. UPON COMPLETION OF THE INSTALSDR F3LA200800200Support Bracket · corrodedDURING C4 S1 C CHECK INSPECTION NOTED THE NOSE LANDING GEAR DECORATIVE DOOR LOWER ATTACH POINTS ON STRUT WERE CORRODED AND WORN. MAINTENANCE REMOVED AND REPLACED THE NOSE LANDING GEAR SUPPORT BRACKET IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 32-22-15-400-001SDR F3LA200700277Battery · dischargedFLIGHT CREW REPORTED EMERGENCY LIGHTS "ON" CAUSING LOW VOLTAGE ON AIRCRAFT BATTERY. REMOVED AND REPLACED NR 1 MAIN BATTERY IAW AMM 24-38-37 PB401. OPS CHECKED GOOD.SDR F3LA200600158Cable · brokenDURING C-3 CHECK, INSPECTION REPORTED RT EMERGENCY EXIT SLIDE INFLATION CABLE BROKEN. REPLACED RESERVOIR IAW AMM 25-62-46.SDR F3LA200600107Line · leakingDURING CRUISE, FLIGHT CREW REPORTED ECAM READING: HYD GREEN RSVR LO LVL G ENG 1 NR 1 PUMP LO PRESS. FOUND NR 1 ENG HYD LOW PRESSURE SWITCH LINE LEAKING. REPLACED LINE AND LEAK CHECKED NORMAL IAW AMM 29-11-49-000-009 AND 29-11-49-400-005.SDR F3LA200600040Filter · dirtyON SHORT FINAL, A PLASTIC-TYPE BURNING ODOR, WHICH DISSIPATED ON LANDING, NO SMOKE. PERFORMED VISUAL INSP OF CABIN LIVE TV SYSTEM. FOUND SYSTEM OPERATIONAL. PERFORMED TSM TASK 24-00-00-810-823 & TSM TASK 26-15-00-810-804 FOR FUMES & ODORS. NO FAULTS, DAMAGSDR F3LA200500014Fan · inoperativeFLIGHT CREW REPORTED VENT EXTRACT FAULT. NOTICED AIRCRAFT VIBRATION, FRONT RIGHTSIDE, AND SMELL OF ELECTRICAL SMOKE FRONT TO BACK OF AIRCRAFT. DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. MAINTENANCE VERIFIED VENT EXTRACT FAN FAILURE AS CAUSE OF ODOR