N997CF, cancelled Mar 18, 2004
Service difficulty reports · 124
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N997CF' AND deregistration_id = 'N997CF-2004-03-18' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N997CF' AND deregistration_id = 'N997CF-2004-03-18' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA010033Indicator · faultyON TAKEOFF ROLL NR 1 ENG EGT TEMP WENT TO 575 DEGREES AND WAS CLIMBING OUTSIDE TEMP 22 EPR 1.88 N1 & FF WERE EVEN ACFT SPEED WAS 70 KNOTS. PERFORMED EGT INDICATOR AND HARNESS TEST IAW MM 77-20-4, & BARFIELD TEST SET INSTRUCTIONS FOUND NR 1 EGT INDICATOR TO SDR RRXA010015Hydraulic Line · rupturedON TAXI IN A/C LOST ALL HYD FLUID. FOUND FLEX LINE ON STOW PUMP RUPTURED. REMOVED AND REPLACED FLEX LINE. LEAK AND OP CK''S GOOD. A/C RETURNED TO SERVICE.SDR RRXA001094O-Ring · damagedRADAR SPOKE IS FUZZY AND TILT POINTS TO THE GROUND AT ALL TIMES. REPLACED DAMAGED O-RING ON BACK OF RADAR RT WAVE GUIDE. PERFORMED FUNCTIONAL TEST PER DC-8 MM 34-41-0, SYSTEM OPS NORMAL ON GROUND.SDR RRXA000285Frame · crackedREPAIR CRACK ON FRAME AT STA 340 BETWEEN L20L AND L21L AND CRACKED WEB PN5772787-13. FABRICATED AND INSTALLED REPAIR ITEM PER EWA SKETCH 04-30-2000-001. BOEING REF BCAG/LBD-ISCC-04300SDR RRXA000198Pin · brokenAFTER TAKE OFF FROM DEN UPON GEAR RETRACTION A LOUD NOISE WAS HEARD AND THE LEFT MAIN GEAR REMAINED DOWN. PER VERIFIED ALT GEAR DOOR LIGHT ON AND SPOILER PRESS REMAINED UP. BOTH DOORS NOT LATCHED AND GEAR NOT LATCHED, REMAINED ON. FOUND EYE BOLT-PIN ON LT SDR RRXA000182Engine · leakingDURING CLIMBOUT, NOTED NR 1 ENGINE LOW OIL PRESS LIGHT ILLUMINATED. NR 1 OIL PRESS 20 PSI AND DROPPING, OIL TEMP DECREASING, NR 1 OIL QUANTITY 1.5 GAL AND DECREASING EVEN AFTER ENGINE WAS SHUTDOWN. PERFORMED INFLIGHT ENGINE SHUTDOWN AND QRH PROCEDURES INITIASDR RRXA991469Skin · corrodedDURING LINE INSPECTION FOUND 6 EACH POPPED FASTENERS ON EXTERNAL SKIN AT STA 270 AND LONGERON 21 RIGHT. INSPECTED ENTERNAL AREA AND FOUND DOUBLER WITH CORROSION DAMAGE BEYOND LIMITS. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLEDSDR RRXA99804Packing · missingHYDRAULIC OIL LOW LIGHT CAME ON HYDRAULIC QUANTITY DECREASING, RESERVOIR LOW PRESSURE LIGHT ON. EMERGENCY PROCEDURE INITIATED. EMERGENCY DECLARED. FOUND HYD LINE MISSING PACKING REPLACED PACKING RAN ENGINES AND AUX PUMP. NO LEAKS NOTED, OPS NORMAL.SDR RRXA99897Actuator · failedON TEST OF FUEL DUMP SYSTEM, WHEN DUMP SWITCH WAS PLACED TO DRAIN THE CHUTES WOULD NOT MOVE TO DRAIN. TRIED MANUAL DRAIN, NO HELP. FUEL CONTINUED TO DUMP TO STAND PIPES. REMOVED AND REPLACED DUMP CHUTE ACTUATOR IAW DC8 MM 28-30-2, OPS CK GOOD AT THIS TIME.SDR RRXA991186Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FWD CARGO COMP C-2 DOOR CUT-OUT BETWEEN STA 500 AND STA 560, BL 34 RIGHT AT FITTINGS. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW AND INSTALLED FSDR RRXA991176Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, ATTACH ANGLE, RT W/W AT STA 879, BL 0, WL 16 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC8 SRM 51-1-4 (PAGE 1);SDR RRXA991225Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, LT CABIN FLOOR BETWEEN STA 680 AND STA 700 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 PGS SDR RRXA991226Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, CABIN FLOOR PLANK AT STA 1460 AND BL 6 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51-1-8 PGS 16 ANDSDR RRXA991224Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1500 AND STA 1520 AT BL 36 LEF. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991237Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1160 AND STA 1270 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991236Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1000 AND STA 1160 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR DOUBLERS IAW DC8 SRM 51-1-8 PG 16SDR RRXA991235Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1460 AND STA 1500 AT BL 26 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER SDR RRXA991234Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1270 AND STA 1300 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991233Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 1360 AND STA 1420 AT BL 22 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991232Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1360 AND STA 1440 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991231Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 580 AND STA 700 AT BL 28 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991230Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 760 AND STA 800 AT BL 32 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC8 SRM SDR RRXA991229Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 600 AND STA 740 AT BL 6 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC8 SRM 5SDR RRXA991228Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 420 AND STA 520 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991227Ffloorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, CABIN FLOOR PLANK BETWEEN STA 580 AND STA 700 AT BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991242Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE,CABIN FLOOR PLANK BETWEEN STA 1240 AND STA 1280 AT BL 12 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLESDR RRXA991241Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK AT STA 1220 AND BL 18 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 PGS 39/4SDR RRXA991240Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1120 AND 1140 AT BL 12 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 FISDR RRXA991239Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1040 AND STA 1060 AT BL 32 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991238Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1100 AND STA 1120 AT BL 32 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991251Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 700 AND STA 822 AT BL 49 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991250Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 460 AND STA 540 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991249Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 900 AND STA 920 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991248Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 700 BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR FILLER AND ANGLE IAW DC8 SRM 51-1-8 PG 16SDR RRXA991247Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 1460 AND STA 1480 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC8 SRM 53-2-3 FIG 10 PSDR RRXA991246Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1460 AND STA 1480 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991245Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 1400, BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 52-2-3 PGS 39/40 FIGSDR RRXA991244Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 880, BL 38 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGS 39/SDR RRXA991243Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 717 AND STA 759 AT BL 36 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991189Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, WEB, CABIN RT TOP OF LOWER CARGO DOOR BETWEEN STA 480 AND STA 520 AT BL 53 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DSDR RRXA991255Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 600 AND STA 620 AT BL 8 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51SDR RRXA991254Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 660 AND STA 680 AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991253Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 840, BL 4 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51-1-8 PG 16 AND 53-2-SDR RRXA991252Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 800, BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGSSDR RRXA991256Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 580 AND STA 879 AT BL 13 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51SDR RRXA991257Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN INT UNDER FLOOR PLANK TOP W/W AT STA 980, BL 24 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 51-1-8 PG SDR RRXA991258Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOORBEAM AT STA 580, BL 45 RIGHT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER ANGLE IAW FAA APPROVED JOSSAIR, COSDR RRXA991185Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE,FUSELAGE SKIN BETWEEN STA 1118 AND STA 1165 BETWEEN LONGERONS 32 RIGHT AND LONGERON 34 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DCSDR RRXA991184Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CENTER TANK AFT TOP SKIN PANEL AT STA 857, BL 46 RIGHT, 2 FORWARD OF REAR SPAR. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUSDR RRXA991183Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN TOP OF W/W UNDER FLOOR BETWEEN STA 902 AND STA 920 AT BL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW EAF-M