CFM International LEAP-1A33
Service difficulty reports · 132
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'LEAP1A33' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'LEAP1A33' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA201912061508Warning Message · false activationAIR ENGINE 1 BLEED LOW TEMP ECAM GROUNDED - YES. RESET BMC #1 AND BITE TEST, TEST GOOD AND FAULT CLEARED PER AMM 36-11-00-740-001-ASDR ASAA201912091510Wire Harness · faultedENGINE #1 IGN A FAULT DURING START UP. AFTER THIRD START ATTEMPT ITS STARTED BUT DISPLAYED ENG 1 START FAULT AND ENG 1 IGN FAIL. GROUNDED - YES. DEFERRED. VERIFIED ENG 1 IGN A FAULT, ITEM RELEASED PER MEL 74-31-01-01-C, MX PROCEDURE C/W SWAPPED OF IGN SYS HARSDR ASAA2019120371497Igniter · failedAFTER 2 FADEC START ATTEMPTS OF # 1 ENGINE RECEIVED "ENG 1 IGN A" INOP STATUS MSSG. (BOTH ENGINES AUTOMATICALLY STARTED SUCCESSFULLY ON IGN B). MEL 74-31-01-01-C. GROUNDED - YES. R & R ENG #1 IGNITER SYS A IAW AMM 74-21-10 PB 401 OPS CHK GOOD , A/C RELEASED SDR ASAA2019112531440Warning Message · false activationAIR ENGINE #1 BLEED LOW TEMP GROUNDED - YES. PERFORMED TSM 36-11-00-810-A98 UP TO STEPS 4A(2). NO FAULTS NOTED. NO MAINTENANCE ACTION NECESSARYSDR ASAA2019112291404Warning Message · false activationAPU BLEED FAULT GROUNDED - YES. ACCOMPLISHED OPERATIONAL TEST OF APU BLEED PER AMM 36-12-00-710-001-A OPS CK GOOD, OK FOR SERVICE A&P 4238317SDR ASAA2019111631367Warning Message · false activationECAM FUEL ACT XFER FAULT GROUNDED - YES. TRANSFERED FUEL FROM ACT TO CENTER TANK AND ECAM MESSAGE AND ACT FAULT. CLEARED. 15312. REF MM 28-25-00-869-056-C AND 28-25-00-869-002A.SDR ASAA2019111541346Warning Message · illuminatedCLASS II MX MESSAGE ENG #1 FADEC GROUNDED - YES. RESET FADEC #1 PER AMM 73-22-00-710-040 OPS CK GOODSDR ASAA2019102831108Valve · misinstalledON CLIMB W/ WING ANTI-ICE ON ECAM AIR ENG 1 BLEED WING ANTI ICE OFF BUT BLEED TEMP ENG 1 AT CRUISE STILL 65C ( OPPOSITE SIDE 200C) GROUNDED - YES. UPON INSPECTION OF FAN AIR VALVES, FOUND THE FLUSH ROD BOLT NOT CONNECTED & ROD HANGING. REINSTALLED ROD TO THE FSDR ASAA2019101931061Pressure Sensor · faultyENGINE 1 OIL SENSOR FAULT GROUNDED - YES. R/R OIL FILTER DIFFERENTIAL PRESSURE SENSOR IAW AMM 79-35-05. LEAK AND OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. MCC JACK NOTIFIED. LIST UPDATED. PLACARD REMOVED. MDDR 72193 CLEARED.SDR ASAA2019092330816Warning System · false activationENGINE 1 FADEC MAINTENANCE MESSAGE ON SHUTDOWN. GROUNDED - YES. ACCOMPLISHED FADEC TEST PER AMM 73-29-00, OPS CHECK GOOD. MESSAGE CLEARED. OK FOR SERVICE.SDR ASAA2019092130814Warning System · activatedENGINE #2 HIGH OIL PRESS SMR FAULT GROUNDED - YES. DEFERRED - WATCH ITEM.SDR ASAA2019091330672Warning System · false activationENGINE 1 OVER-THROTTLE PROTECTION FAULT. GROUNDED - YES. PERFORMED ENG 1 IDLE TEST ON CHANNEL A AND B, NO FAULTS NOTED PER TSM 73-21-01-810-922-A. NO MAINTENANCE ACTION REQUIRED.SDR ASAA2019081030352Sensor · failedENG 1 CHANNEL B FUEL STRAINER SENSOR FAULT SEEN FOR SMR CHECK T/C 73-0000-L1-1-VAMENG 2 CHANNEL A FUEL STRAINER SENSOR FAULT SEEN FOR SMR CHECK. T/C 73-0000-L1-1-VAM GROUNDED - YES. R&R FUEL STRAINER SENSOR IAW AMM 73-34-10 SYSTEM TESTED & LEAK CHECKED OK.SDR ASAA2019071030014Warning System · activatedENGINE 2 HP TIP CTL FAULT MESSAGE OPENED, THEN CLOSED ON CLIMB. GROUNDED - YES. PERFORMED TSM TASK 75-31-00-710-081-A STEPS 4.B (1) (A) (B) (C) AND 4.B (2) (A) (B) (C), CLEANED BOTH RECETACLES. NO HELP. VERIFIED FAULT, RELEASED PER MEL 75-21-01, ACCOMPLISHED MSDR ASAA2019070629932Unknown · malfunctionedENGINE 2 HP TIP CONTROL FAULT. GROUNDED - YES. ACCOMPLISHED TSM 75-22-810-819A FAULT OF THE LPTCC VALVE (POSITION FAILED OPEN) #2 ENGINE. OPERATIONAL ENGINE IDLE TEST ON CHANNEL A AMM 75-22-810-819A. TEST SHOWED NO FAULTS AND NO MX ACTION REQUIRED.SDR ASAA2019062869835Fault Message · false activationENGINE 1 REV MINOR FAULT. GROUNDED - YES. PERFORMED THRUST REVERSER CYCLING TEST ON BOTH CHAN FOR BOTH ENGS REF AMM 73-29-00-740-804-A. NO FAULTS NOTED. OPS CHECKS GOOD.SDR ASAA2019062429699Igniter · faultedENGINE 2 IGNITION B FAULT, GROUNDED - YES. R & R THE NR 2 ENGINGER IGNITION B IGNITER IAW AMM 74-21-10. PERFORM ENG IDLE TEST NO FAULT.SDR ASAA2019062439687Engine · stalledNR 2 ENGINE STALL ON ECAM ON POWER REDUCTION IN INITIAL DESCENT. AIRCREW FELT A YAW AND QUICK DROP AND RETURN OF ENGINE PARAMETERS, NO EXCEEDANCES NOTED. GROUNDED - YES. REMOVED AND REPLACED THE NR 2 ENGINE IAW AMM 71-00-51.SDR ASAA2019061129688Valve · failedDURING CLIMB OUT, ECAM ENGINE 1 HP TIP CONTROL FAULT RECCURING HAD TO ENGINE CANCEL. GROUNDED - YES. REMOVED AND REPLACED ENGINE 1 LPTACC VALVE FIN 4186KS . REF AMM 75-22-05PB401 PERFORMED IDLE TEST (MENU MODE) REF 73-29-00-740-803-A . TEST OK. ACCOMPLISHEDSDR ASAA2019060759615Warning Message · false activationCLASS II MAINT MSG AIR BLEED. GROUNDED - YES. DEFERRED. RMA PENDINGSDR ASAA2019040848925Thrust Reverser · faultedENGINE 1 REV MINOR FAULT. GROUNDED - YES. ONE DEFERRAL. ETOPS RESTRICTEDSDR ASAA2019040848927Valve · failedENGINE 1 FUEL RETURN VALVE. VALVE NOT CLOSED. GROUNDED - YES. PERFORMED ACTUATORS TEST PER AMM 73-29-00-740-802-A. TEST OK. NO FAULTS NOTED AT THE TIME OF THE TEST.SDR ASAA2019033128843Igniter · damagedENGINE 2 IGNITION B FAULT GROUNDED - YES. #2 EXCITER & #2 IGINITION LEAD WERE PREVIOUSLY REPLACED DEFECT 8038515 & 8056845 RESPECTIVELY. HARNESS FOUND FUSED TO IGNITER HARNESS (IGNITER LEAD) & IGNITER REPLACED IAW AMM 71-51-43 & AMM 74-21-10 SYSTEM TEST OK ALSDR ASAA2019040198841Line · crackedDURING VISUAL INSP OF ENG 2 HIGH OIL CONSUMPTION FOUND OIL LINE TO AGB CRACKED. GROUNDED - YES. R & R OIL TUBE REF AMM 79-21-05. OPS CHECK LEAKS, NO LEAKS FOUND. ENG # 2 OK FOR SERVICE.SDR ASAA2019032828859Sensor · failedENGINE 1 FUEL SENSOR FAULT, FUEL STRAINER SENSOR. GROUNDED - YES. REMOVED AND REPLACED #1 ENGINE FUEL STRAINER SENSOR 4081 KS PER AMM 73-34-10 PB 401. OPS AND LEAK CHECK GOOD. THIS CLEARS MDDR 65155. WATCH ITEM LOG UPDATED. MCC CARLOS NOTIFIED.SDR ASAA2019032628795Sense Line · leakingDURING INSPECTION FOUND BLEED AIR LEAK ON SENSE LINE ENG NR 1 (SEE RMA 2811 AND MDDR 64918) GROUNDED - YES. R/R ENG 1 ECS INDICATING TUBE PER AMM 36-11-49-400-831-A. OPS / LEAK CK WILL BE C/W ON LP 8034834 ITEM 1. ( P/N: ER9691PO1 )SDR ASAA2019031928713Warning System · false activationENGINE 1 OVER THROTTLE PROTECTION FAULT GROUNDED - YES. PERFORMED FADEC TEST PER AMM 73-29-00-710-802. NO FAULT FOUND. ACFT OK FOR SERVICE.SDR ASAA2019031228620Engine · oil consumptionREF 8025318 NR 1 ENGINE OIL CONSUMPTION GROUNDED - YES. ACCOMPLISHED TSM 79-00-00-810-842-A 1-4 AND 4B 1-4 NO DEFECT NOTED SERVICED NR 2 ENGINE WITH 4 QTS OF OIL REF. LP#8025322 (3) NR 2 ENGINE SN#598239 REPLACED PER W/O# 388938 & 388939.MDDR 64677 CLOSED , WSDR ASAA2019021628186Fadec · malfunctionedENGINE 1 FADEC MESSAGE AT GATE GROUNDED - YES. RESET FADEC 1 AMM 73-29-00-710-040=01 CLASS 2 MSG CLEARED.SDR ASAA2019021028129Ignition Sys · faultedENGINE 2 IGNITION B FAULT GROUNDED - YES. ON DEFERRAL.SDR ASAA2019013127994Harness · failedENGINE NR 2 IGNITER SYSTEM B FAULT NO ENGINE LIGHT UP ONLY SYSTEM A GROUNDED - YES. SWAPPED EIU 1&2, NO HELP FAULT REMAINS. SWAPPED CONNECTORS AT IGNITION EXCITERS FROM A TO B AND FAULT FOLLOWED RETURNED TO ORIGINAL POSITION . FURTHER T/S REQUIRED. PER TSM 74-SDR ASAA2019011227786Warning System · false activationENG 1 REV MINOR FAULT ECAM MSG ON LANDING. GROUNDED - YES. PERFORMED TSM 77-11-00-810-839. NO FURTHER MX ACTION NECESSARY.SDR ASAA20181227572Warning Message · false activationCLASS II AIR BLEED MSG. GROUNDED - YES. RESET FWC 1 AND 2. MSG CLEARED. OK FOR SVC. BMC TEST OK.SDR ASAA2018122527573Sensor · failedDURING W/O 384707, T/C 730000-L1-1 SMR CORRECT FADEC FAULTS SHOWS FUEL STRAINER SNSR FAULT ON ENG 2 CH B. REF TSM 73-34-00-810-102-A SUBTASK B. REF MDDR 62199 FOR WI. GROUNDED - YES. R&R ENG 2 FUEL STRAINER DIFFERENTIAL PRESSURE SENSOR PER AMM 73-34-10 PB 40SDR ASAA2018113027194Engine · faultedENGINE 2 MINOR FAULT GROUNDED - YES. FAULT DID NOT OCCUR 5 CONSECUTIVE FLIGHTS, NO MAINTENANCE ACTION REQUIRE PER TSM 77-11-00-810-840A. OK FOR SVC.SDR ASAA2018112927193Warning System · false activationENGINE 1, EEC CHANNEL B HAS FAULT 0188-FUEL STRAINER DISAGREE. FAULT HAS BEEN REPEATING SINCE 06 NOV. TRANSFERRED FROM NON-ROUTINE, TRAX N/R. GROUNDED - YES. PLACED ON WISDR ASAA2018112127044Warning System · activatedECAM ENG 2 MINOR FAULT GROUNDED - YES. DEFERRED PER MEL 73-30-05.SDR ASAA2018110926839Warning System · false activationENG 2 MINOR FAULT MESSAGE AFTER SHUTDOWN GROUNDED - YES. PERFORMED ENG NR 2 IDLE TEST PER AMM 73-29-00-740-803-A. NO FAULTS FOUND.SDR ASAA2018110626741Warning System · false activationON LANDING RECEIVED ECAM ENG 2 MINOR FAULT GROUNDED - YES. PREFORMED FADEC TEST REF AMM 73-29-00-710-802A AND IDCE TEST REF AMM 73-29-00-740-803-A NO FAULTS NOTED AT THIS TIME FOR ENG 2.SDR ASAA2018102626606Warning System · false activationENG1 FADEC SYS FAULT THR LVR 1 NOT ABOVE IDLE ECAM MESSAGE ON TAXI IN. GROUNDED - YES. PER GENERAL NUISANCE FAULTS AND T/S TIPS ( ISI 73.00.00045 ) MX-ACTION ACCOMPLISHED PER TSM 73-21-01-810-928A NO CONFIRMATION OF FAULT POST ENG 1 IDLE RUN. A/C RELEASED TO SSDR ASAA2018102326576Warning System · activatedCAUTION MSG ENG NR 2 MINOR FAULT GROUNDED - YES. *DEFERRED MEL 73-30-05*SDR ASAA2018101126447Warning System · false activationENG 1 MINOR FAULT GROUNDED - YES. PERFORMED TSM 77-11-00-810-839-A, FAULT APPEARED PHASE 9, NO MAINTENANCE ACTION NECESSARY.SDR ASAA2018100826382Relay · faultyFADEC 2 FAULT MESSAGE ON UPPER ECAM. GROUNDED - YES. IDLE RUN NR 2 ENG PER AMM 71-00-00. NO FAULTS COUND NOT ACCESS FADEC 2 THRU MCDU. FOUND FAULTY RELAY 11KS2 REF AWM 73-25-06 P 0029 SHEET 1 REPLACED RELAY 11KS2 FADEC 2 TEST PER AMM 73-29-00 PB 501.SDR ASAA2018100826383Warning System · false activationENG 2 FADEC FAULT GROUNDED - YES. PERFORMED FADEC TEST & ESN CHANGE PER TSM 73-21-00. TEST OK.SDR ASAA2018092726292Warning Message · false activationENG 2- MINOR FAULT ONLANDING. GROUNDED - YES. PERFORMED ENG 2 FADEC TEST. TEST OK NO FAULTS AT THIS TIME REF AMM 73-29-00SDR ASAA2018092626293Fault Message · false activationENGINE 2 MINOR FAULT GROUNDED - YES. NO FAULTS ON ECAM FADEC TEST IAW LEAP 1A TFU REF 73.20.00.049 MESSAGE CLEAREDSDR ASAA2018092526289Fault Message · false activationENG 2 FADEC SYS FAULT. GROUNDED - YES. PERFORMED FADEC TEST ON ENG 2 CHANNEL A & B REF AMM 73-29-80. TEST OK. PERFORMED TFU REF 73-20-00-049. A/C OK FOR SVC.SDR ASAA2018092826291Fault Message · false activationENGINE 2 FADEC CLASS II STATUS MESSAGEENGINE 1,2 MINOR FAULT GROUNDED - YES. ITEM 1 DEFERREDPERFORMED ENG 1 AND 2 FADEC TEST OPS CK SATISFATCTORY PER TSM 71-00-00-810SDR ASAA2018092426287Warning Message · illuminatedAFTER SHUTDOWN IN GATE MAINT STATUS ENG 2 ANTI ICE ON LOWER ECAM. GROUNDED - YES. DEFERREDSDR ASAA2018092426288Fault Message · false activationENG2 FADEC SYS FAULT .THR LEVER 2 NOT ABOVE IDLE GROUNDED - YES. REF LOG PG 8030102 ITEM-1 AND LOG 8030103 ITEM-1 FOR T/S PER TSM AND FADEC TEST PER AMM 73-29-80-740-803, TEST OK. PERFORMED TFU REF 73.20.00.049. A/C OK FOR SERVICE.
Back to CFM International LEAP-1A33