GE CFM56 series
Service difficulty reports · 5,028
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'CFM56' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'CFM56' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2003UALA00020Frame · crackedSTATION 887 FRAME CRACKED AT RIVET HOLE NEAR STRINGER 9L. MAJOR REPAIR ACCOMPLISHED. DOUBLER MANUFACTURED AND INSTALLED.SDR 2003UALA00021Frame · crackedSTATION 887 FRAME CRACKED AT RIVET HOLE NEAR STRINGER 9R. MAJOR REPAIR ACCOMPLISHED. DOUBLER MANUFACTURED AND INSTALLED.SDR 2003UALA00022Frame · crackedSTATION 867 FRAME CRACKED AT RIVET HOLE NEAR STRINGER 9L. MAJOR REPAIR ACCOMPLISHED. DOUBLER MANUFACTURED AND INSTALLED.SDR 2003UALA00030Bulkhead · crackedSTATION 178 BULKHEAD WEB CRACKED AT RBL 1 IN WL 188. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR 2003UALA00031Bulkhead · crackedSTATION 178 BULKHEAD WEB CRACKED AT RIGHT LOWER RADAR MOUNT INBOARD UPPER SIDE. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR 2003UALA00032Frame · crackedCABIN BODY FRAME WEB IS CRACKED BS 400 STRINGER 9L. MAJOR REPAIR ACCOMPLISHED. SPLICED BODY FRAME WEB.SDR 2003UALA00033Crease Beam · corrodedCORROSION ON RIGHT CREASE BEAM INBOARD CHORD FROM BS 294 TO BS 334. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM.SDR 2003UALA00034Frame · dentedAFT PIT RIGHT FRAME STATION 727C DENTED AT RBL 28. MAJOR REPAIR ACCOMPLISHED. FRAME REPAIRED.SDR 2003UALA00035Bearing · failedFLIGHT CREW DECLARED AN EMERGENCY WHEN CREW NOTICED ELECTRICAL SMELL IN THE CABIN DURING DESCENT. SUPPLEMENTAL DATA UPDATE THE RECIRCULATION FAN BEARING FAILED, WHICH CAUSED AN ELECTRICAL SMELL IN THE PASSENGER CABIN AND RESULTED IN CIRCUIT BREAKER C884 POPPINSDR 2003F00083Lens · missing(ORIGINAL CLOSED) EMERGENCY PATH FLOOR PROXIMITY LIGHT AFT OF RIGHT NR 2 OVERWING EXIT MISSING LENS; INSTALLED EXIT LENS AS REQUIRED. OK FOR SERVICE..SDR 2003UALA00019Frame · crackedBODY STATION 867, STRINGER 9R, FUSELAGE FRAME CRACKED AT RIVET HOLE. MAJOR REPAIR ACCOMPLISHED. DOUBLER MANUFACTURED AND INSTALLED.SDR 2003UALA00025Stringer Clip · crackedCABIN STRINGER CLIP CRACKED BS 270 STRINGER 15R. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER CLIP.SDR 2003UALA00026Crease Beam · corrodedCREASE BEAM WEB BELOW FORWARD GALLEY DOOR STA 297 - STA 327 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR SWAA030017Starter · leakingIN-FLT SHUTDOWN, DECLARED EMERGENCY, DURING CRUISE NR 1 ENGINE OIL QUANTITY DROPPED TO 0, OIL PRESS LIGHT ILLUMINATED. REMOVED AND REPLACED NR 1 ENGINE STARTER PER MM.SDR 2003UALA00012Frame · crackedSTATION 827 FRAME CRACKED AT RIVET HOLE AT S9R. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER INSTALLED.SDR 2003UALA00013Frame · crackedSTATION 827 FRAME CRACKED AT RIVET HOLE S9L. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2003UALA00014Frame · crackedSTATION 847 FRAME CRACKED AT RIVET HOLE S9L. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2003UALA00009Frame · crackedSTATION 847 FRAME CRACKED AT RIVET HOLE AT STR 9R. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR 2003UALA00010Frame · crackedSTATION 807 FRAME CRACK AT RIVET HOLE STR S9-R. MAJOR REPAIR ACCOMPLISHED. FRAME DOUBLER INSTALLED.SDR 2003UALA00011Floorbeam · crackedCRACK IN UPPER FLANGE OF CABIN FLOOR INTERCOSTAL AT BS 346 FLOORBEAM BL0 SEEN FROM LOWER SIDE. MAJOR REPAIR ACCOMPLISHED. INSTALLED FILLER AND DOUBLER.SDR 2003UALA00008Frame · crackedSTATION 767, STRINGER 9R, FUSELAGE FRAME CRACKED AT RIVET HOLE. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED AND INSTALLED REPAIR DOUBLER.SDR 2003UALA00018InverterEMERGENCY ELECTRICAL LIGHTING STRIP BETWEEN ROWS 15 AND 21 INOPERATIVE SUPPLEMENTAL DATA UPDATE INOPERATIVE LIGHT INVERTER. REPLACED AND SYSTEM OPS CK GOODSDR SWAA030046Control Quadrant · obstructedIN-FLT SHUTDOWN, PRIOR TO DESCENT, NR 1 ENGINE THRUST LEVER WOULD NOT RETARD. FOUND DEBRIS INSIDE THROTTLE QUADRANT, REMOVED DEBRIS AND OPS CK GOOD PER MM.SDR 2003UALA00128Skin · dentedFASTENER INSTALLED AT STA 478 BETWEEN STRINGER 2R & STRINGER 3R IS INSTALLED IN A COCKED POSITION AND HAS DENTED SKIN. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2003UALA00003Frame · dentedAFT PIT FRAME AT STATION 727B STRINGER 22L, UPPER CAP DENTED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2002UALA01903Skin · dentedDENT IN LEADING EDGE OF RIGHT HAND HORIZONTAL STABILIZER, 8 INCHES INBOARD OF TIP. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2002UALA01904Skin · puncturedPUNCTURE HOLE BETWEEN WL194 AND WL207.5 AND BODY STATION 227.8 AND BODY STATION 243.7. AREA IS JUST FORWARD AND ABOVE RIGHT PITOT TUBE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.INSTALLED REPAIR DOUBLER.SDR USAASB02241A/C Pack · contaminatedALB - FLT 1544 - IMMEDIATELY AFTER TAKEOFF, CREW REPORTED A STRONG BURNING ODOR THROUGHOUT CABIN. AT APPROXIMATELY 5,000 FT, THE SMOKE ALARMS SOUNDED. CAPTAIN DECLARED AN EMERGENCY AND ELECTED TO DIVERT TO ALB. FLIGHT LANDED WITHOUT INCIDENT AND TAXIED TO TSDR USAASB02238Engine · odorPILOT REPORTED THE AFT LAVATORY SMOKE DETECTORS SOUNDED DUE TO AN OIL ODOR IN THE CABIN. FLIGHT LANDED AT EWR WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED DUCTING AND ISOLATED OIL ODOR COMING FROM RT ENGINE. (RT ENGINE RECENTLY EXPERIENCED AN IMPACT WITH SDR 2002UALA01898Clip · crackedBODY STATION 178 LOWER CHORD RBL20, WL188, Z CLIP TO INTERCOSTAL IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED Z CLIP.SDR 2002UALA01892Warning Light · illuminatedAFT CARGO LIGHT CAME ON JUST BEFORE V1. RETURN TO FIELD.SDR 2002UALA01888Frame · crackedFORWARD CABIN FRAME AT STATION 400 IS CRACKED STRINGER 9L. MAJOR REPAIR ACCOMPLISHED. INSTALLED A J-ANGLE DOUBLER.SDR 2002UALA01881Frame · crackedCABIN STATION 847 FRAME IS CRACKED AT FASTENER JUST ABOVE STRINGER 9L. MAJOR REPAIR ACCOMPLISHED. INSTALLED A J-ANGLE DOUBLER.SDR 2002UALA01882Frame · crackedCABIN STATION 867 FRAME CRACKED JUST ABOVE STRINGER 9R. MAJOR REPAIR ACCOMPLISHED. INSTALLED A J-ANGLE DOUBLER.SDR 2002UALA01883Frame · crackedCABIN STATION 807 FRAME CRACKED AT FASTENER JUST ABOVE STRINGER 9R. MAJOR REPAIR ACCOMPLISHED. INSTALLED A J-ANGLE DOUBLER.SDR 2002UALA01878Frame · crackedCABIN STA 827 FRAME CRACKED AT FASTENER ABOVE STRINGER 9R. MAJOR REPAIR ACCOMPLISHED. INSTALLED FRAME REPAIR .SDR 2002UALA01879Frame · crackedAFT CABIN FRAME IS CRACKED STATION 767 STRINGER 9R. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED AND INSTALLED DOUBLER REPAIR.SDR 2002UALA01880Frame · crackedCABIN STATION 807 FRAME CRACKED AT FASTENER JUST ABOVE STRINGER 9L. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED AND INSTALLED FRAME REPAIR.SDR 377PA0009Computer · failedFMC COMPUTER POPS CIRCUIT BREAKER. REMOVED AND REPLACED FMC COMPUTER. BITE CHECK. OK IAW MM.SDR 2002UALA01874Frame · crackedFUSELAGE FRAME, STATION 188, LEFT OUTBOARD CHORD CRACKED AT STRINGER 17 WL 207. MAJOR REPAIR ACCOMPLISHED. CHORD AND WEB REPAIR INSTALLED.SDR 2002UALA01875Frame · crackedCABIN FUSELAGE FRAME STATION 747 IS CRACKED AT STRINGER 9R. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER INSTALLED.SDR 2002UALA01876Frame · crackedFUSELAGE FRAME, STATION 188, RIGHT SIDE IS CRACKED IN OUTBOARD CHORD AT STRINGER 17R. MAJOR REPAIR ACCOMPLISHED. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR.SDR 2002UALA01877Web · crackedFUSELAGE WEB STA 188-199 AT WL 207 ON LEFT SIDE CRACKED IN CUTOUT RADIUS FOR FRAME FLANGE. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB.SDR 2002UALA01884Flap · malfunctionedUPON SELECTING FLAPS ONE, FLAP NEEDLES SPLIT AND FLAPS LOCKED OUT. CREW FOLLOWED FLIGHT MANUAL PROCEDURE AND DIVERTED.SDR 2002UALA01867Skin · damagedRIGHT FUSELAGE SKIN, FORWARD OF POWER RECPT DOOR, HAS EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED AND INSTALLED SKIN REPAIR .SDR 2002UALA01868Clip · crackedCABIN FRAME SUPPORT CLIP ON STRINGER 11R, CRACKED AT STATION 344. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED AND INSTALLED NEW CLIP.SDR 2002UALA01869Skin · dentedEXTERNAL FUSELAGE SKIN IS DENTED AT STATION 312 BELOW STRINGER 24R. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER MANUFACTURED AND INSTALLED.SDR 2002UALA01870Frame · crackedMID CABIN STATION 616 RIGHT FUSELAGE FRAME INNER CHORD CRACKED AT LOWER EDGE, JUST BELOW CABIN FLOOR. MAJOR REPAIR ACCOMPLISHED. REPAIR ANGLE MANUFACTURED AND INSTALLED.SDR 2002UALA01871Stringer Clip · crackedSTRINGER CLIP CRACKED AT STATION 616, STRINGER 2L. MAJOR REPAIR ACCOMPLISHED. STRINGER CLIP REPLACED.SDR 2002UALA01872Bracket · crackedFORWARD CABIN RIGHT SIDE STATION 291.5, STR 11 AND 12 RIGHT, JUST INBOARD OF GALLEY DOOR CUTOUT, ANGLE BRACKET CRACKED. MAJOR REPAIR ACCOMPLISHED. CRACKED ANGLE REMOVED AND REPLACED WITH NEW.
Back to GE CFM56 series