SDR 2002UALA00788Skin · crackedTHERE IS A 2.5 INCH CRACK IN FUSELAGE AT LOWER AFT RADIUS OF DOOR 1R OPENING. MAJOR REPAIR ACCOMPLISHED. REPAIR ANGLE INSTALLED. VERIFIED CRACK FREE AFTER DAMAGE REMOVED.SDR 2002UALA00816Skin · crackedTHERE IS A 2.5 INCH CRACK IN FUSELAGE COMING OFF LOWER AFT RADIUS OF DOOR 1R OPENING. MAJOR REPAIR ACCOMPLISHED. THREE LAYER REPAIR USED DUE TO CRACK THROUGH STRAP, SKIN & BONDED DOUBLER.SDR 2002UALA00775Bulkhead · crackedSTATION 178 BULKHEAD CRACKED AT RBL 517 INBOARD SIDE LOWER ANTENNA. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR.SDR 2002UALA00789Battery Pack · shortedEMERGENCY EXIT LIGHTS ROWS 8 THROUGH 14 INOPERATIVE. ORANGE LIGHT AT EMERGENCY EXIT ROW 9 DIM. RECONNECTED LIGHT STRIP. OPS CHECK FOUND SHORTED POWER PACK. REPAIRED POWER PACK.SDR 2002UALA00771Skin · damagedLEFT HAND FUSELAGE AT APPROXIMATELY STATION 360 AND STRINGER 16L HAS GOUGE AND DENT. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2002UALA00772Window Frame · corrodedLEFT HAND NR 5 CABIN WINDOW FRAME LOWER AFT CORNER INBOARD EDGE HAS EXCESSIVE MATERIAL LOSS IN SEAL CONTACT AREA DUE TO CORROSION REMOVAL. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED AND INSTALLED EXTERNAL LOWER HALF DOUBLER REPAIR.SDR 2002UALA00773Circuit Breaker · failedDIVERTED TO DEN DUE TO LOSS OF GENERATOR. THE AIRCRAFT WAS DIVERTED TO DENVER WITHOUT INCIDENT. AMT CREW ISOLATED CAUSE OF FAILURE DUE TO NR 2 TRANSFER BUS NORMAL CIRCUIT BREAKER (C821) AS BAD. THE CIRCUIT BREAKER WAS REPLACED, AND THE AIRCRAFT WAS RETURNEDSDR 2002UALA00774Circuit Breaker · failedDIVERTED TO DEN DUE TO ELECTRICAL PROBLEMS. CREW REPORTED NR 2 TRANSFER BUS CIRCUIT BREAKER (C821) POPPED IN CRUISE & IN SMOOTH AIR. REPORTED LOSING FIRST OFFICER'S INSTRUMENTS INCLUDING EADI AND EHSI. THE AIRCRAFT WAS DIVERTED TO DEN WITHOUT INCIDENT. AMTSDR 2002UALA00757Floorbeam · corrodedCABIN STATION 987 FLOORBEAM CAP CORROSION REMOVAL BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. ACCOMPLISHED SPLICE REPAIR.SDR 2002UALA00758Panel · faultyLANDED UNDER AMBER ALERT DUE TO CARGO FIRE LIGHT ILLUMINATED ON FINAL APPROACH. MAINTENANCE REMOVED AND REPLACED THE CARGO DETECTION PANEL, BOTH FIRE BOTTLES, METERING VALVE, DIVERTER VALVE, LINE FILTERS, PERFORMED INSPECTION OF THE CARGO COMPARTMENT DISCHARGSDR 2002UALA00753Skin · dentedEXTERNAL FUSELAGE DENTED AT APPROXIMATELY STATION 410 BETWEEN STRINGER 25R AND 26R. DENT IS WITHIN 10 INCHES OF CUTOUT AND WITHIN 3 INCHES OF SKIN SPLICE. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED DOUBLER REPAIR.SDR 2002UALA00750Skin · crackedEXTERNAL FUSELAGE AT KEEL BEAM STATION 698 LBL 4 LOWER SKIN CRACKED. MAJOR REPAIR ACCOMPLISHED. EXTERNAL DOUBLER INSTALLED.SDR 2002UALA00746Crease Beam · corrodedSTRINGER 17R CREASE BEAM HAS CORROSION FROM STATION 294 TO 328 RBL 58 INBOARD ANGLE. MAJOR REPAIR ACCOMPLISHED. REPLACED SECTION OF CREASE BEAM INBOARD CHORD ANGLE.SDR 2002UALA00747Crease Beam · corrodedRIGHT HAND CABIN STATION 727B TO 727C STRINGER 17R WL 208 CREASE BEAM WEB CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM WEB.SDR 2002UALA00748Floorbeam · corrodedFLOORBEAM AT BODY STATION 335 RBL 16 TO RBL 24 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOORBEAM.SDR USAASB02078Engine · making metalCLT - FLT 379 - AFTER TAKEOFF, CREW NOTED AN OVERTEMP CONDITION ON THE RIGHT ENGINE. THE TOWER INFORMED THE CREW THAT BLACK SMOKE WAS POURING FROM THE ENGINE. THE CREW REDUCED POWER ON THE RIGHT ENGINE. THE FLIGHT RETURNED TO CLT AND LANDED WITH NO FURTHER SDR 2002UALA00744Stringer · crackedLEFT HAND BODY STATION 188 STRINGER 17L IS CRACKED. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLERS.SDR 2002UALA00745Crease Beam · corrodedLEFT HAND CABIN STATION 727C TO 727D STRINGER 17 WL 208 CREASE BEAM WEB CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB.SDR 2002UALA00740Frame · crackedSTATION 867 FRAME IS CRACKED AT STRINGER 9R RIVET HOLE. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2002UALA00741Crease Beam · corrodedCREASE BEAM WEB CORRODED 3 AREAS STATION 620 - 640 RIGHT HAND SIDE. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER 17R CREASE BEAM WEB.SDR 2002UALA00742Frame · crackedRIGHT HAND STUB FRAME STATION 294 STRINGER 17R WL 208 CRACKED. MAJOR REPAIR ACCOMPLISHED. INSTALLED FILLER AND DOUBLER.SDR 2002UALA00727Frame · crackedCABIN FRAME STATION 847 CRACKED AT STRINGER 9L RIVET. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2002UALA00728Frame · crackedCABIN STATION 867 STRINGER 9L FRAME IS CRACKED AT RIVET. MAJOR REPAIR ACCOMPLISHED. INSTALLED FILLER AND DOUBLER.SDR 2002UALA00729Frame · crackedCABIN STATION 887 STRINGER 9R FRAME IS CRACKED AT RIVET. MAJOR REPAIR ACCOMPLISHED. INSTALLED FILLER AND DOUBLER.SDR 2002UALA00725Frame · crackedCABIN FRAME AT STATION 847 STRINGER 9R IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPAIR ANGLE INSTALLED.SDR 2002UALA00711Skin · damagedLEFT HAND FUSELAGE SKIN SURFACE AT BS420, TWO AREAS HAVE EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER AND FILLER REPAIR.SDR 2002UALA00712Skin · dentedLOWER FUSELAGE SKIN IS DENTED BELOW FORWARD PIT DOOR CUTOUT FORWARD CORNER. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA00713Frame · crackedLEFT HAND SIDE BS 188 CHORD AT STRINGER 17L CRACKED. MAJOR REPAIR ACCOMPLISHED. INSTALLED CHORD DOUBLER AND SKIN DOUBLER.SDR 2002UALA00714Frame · gougedAFT CARGO PIT FRAME STATION 727E, STR 25L-26L, LBL 14 HAS DEEP GOUGE. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED DOUBLER AND FILLER REPAIR.SDR 2002UALA00715Stringer · damagedSTATION 727B STRINGER 19L ON INBOARD FLANGE HAS EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED DOUBLER AND STRAP REPAIR.SDR 2002UALA00716Frame · gougedAFT PIT LEFT HAND FRAME STATION 727D GOUGED ON FORWARD SIDE AT RADIUS, BETWEEN STRINGER 19L AND 20L. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR ANGLE.SDR 2002UALA00717Skin · damagedLOWER EXTERIOR FUSELAGE SKIN AT FORWARD CARGO DOOR LOWER AFT CUTOUT CORNER HAS EXCESS MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED DOUBLER AND STRAP REPAIR.SDR 2002UALA00704Frame · crackedCABIN STATION 616 FRAME CHORD WEB IS CRACKED JUST BELOW STRINGER 17R. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED FILLER AND ANGLE REPAIR.SDR 2002UALA00705Skin · damagedLOWER FUSELAGE SKIN AT FORWARD CARGO DOOR CUTOUT, LOWER FORWARD CORNER HAS 30 PERCENT MATERIAL LOSS AFTER BLENDING. MAJOR REPAIR ACCOMPLISHED. EXTERNAL DOUBLER INSTALLED.SDR 2002UALA00700Skin · damagedLEFT HAND UPPER FUSELAGE SKIN BELOW CABIN WINDOW AT STATION 410 WAS BLENDED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED DOUBLER REPAIR.SDR 2002UALA00701Skin · gougedLEFT HAND FUSELAGE AFT OF ENTRY DOOR 2L GOUGED AT TWO AREAS. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. INSTALLED DOUBLER REPAIR.SDR 2002UALA00702Frame · damagedAFT PIT FRAME STATION 727E BLENDED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. REPAIR STRAP INSTALLED.SDR 2002UALA00703Frame · damagedSTATION 727C FRAME AT STRINGER 19L BLENDED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. REPAIR STRAP INSTALLED.SDR 2002UALA00677Skin · damagedLEFT HAND UPPER FUSELAGE SKIN BELOW CABIN WINDOW AT STATION 390 WAS BLENDED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR USAASA02036P-Lead · faultyAIRCRAFT FAILED THE EMERGENCY LIGHTS TEST. MAINTENANCE REPLACED THE EMERGENCY POWER SUPPLY UNIT.SDR 2002UALA00664Skin · dentedEXTERIOR FUSELAGE DENTED AT BS 800, STR 25R, RBL 64. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER AND FILLER.SDR 2002UALA00665Frame · puncturedRIGHT HAND CABIN BODY STATION 520 STRINGER 16R2 FRAME CHORD PUNCTURED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW ANGLE.SDR 2002UALA00656Frame · dentedSTATION 787 FRAME HAS DENT ON TOP FLANGE BETWEEN STRINGER 23R AND 24R. MAJOR REPAIR ACCOMPLISHED. EXTENDED A SPLICE PLATE AND INSTALLED FILLER.SDR USAASA02035Wire · brokenAN EMERGENCY LIGHT WAS INOPERATIVE AT SEAT 9D. MAINTENANCE REPAIRED A BROKEN WIRE. OPERATIONALLY CHECKED OK.SDR 2002UALA00815Light · inoperativeEMERGENCY EXIT LIGHT FLOOR MOUNTED LIGHTING STRIP AFT OF SEAT ROW 13 INOPERATIVE. REPLACED POWER STRIP & EMERGENCY EXIT LIGHT AS NEEDED.SDR 2002UALA00649Bear Strap · damagedAFT CARGO DOOR CUTOUT AFT EDGE BEAR STRAP HAS TWO AREAS OF EXCESSIVE MATERIAL LOSS DUE TO DAMAGE BLEND OUT. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER TRIPLER REPAIR.SDR 2002UALA00653Floorbeam · corrodedAFT CABIN FLOORBEAM AT STATION 946 RBL 20 HAS EXCESSIVE MATERIAL LOSS DUE TO CORROSION REMOVAL. MAJOR REPAIR ACCOMPLISHED. INSTALLED REINFORCEMENT ANGLE.SDR 2002UALA00654Frame · dentedAFT PIT FRAME DENTED STATION 727B AT STRINGER 25L. MAJOR REPAIR ACCOMPLISHED. INSTALLED REINFORCEMENT ANGLE REPAIR.SDR 2002UALA00655Stringer · crackedLEFT HAND FORWARD CABIN, STRINGER 10L CRACKED AT STATION 297. MAJOR REPAIR ACCOMPLISHED. REPLACED WITH NEW STRINGER.SDR 2002UALA00647Stiffener · chafedNR 1 FUEL TANK AT WINGROOT, 20 INCHES AFT OF FORWARD SPAR, LOWER STIFFENER HAS DEEP WEAR ON UPPER SURFACE OF LOWER FLANGE DUE TO CHAFING OF FUEL LINE. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR ANGLE.
Back to GE CFM56 series