SDR 2008UALA00484Epsu · faultyEMERGENCY LIGHTS FAIL TEST WITH EPSU FWD L EFG MSG. EPSU FAILURE. REPLACED EPSU.SDR 2008UALA00486Oxygen Bottle · low pressureO2 BOTTLE LOW AT SEAT ROW 26ABC. REMOVED AND REPLACED O2 BOTTLE.SDR 2008UALA00510Slide · shortedEMERGENCY LIGHT SYSTEM TEST FAILS WITH CFDS MESSAGE EXT LOAD FWD LEFT. ELECTRICAL SHORT WITHIN FWD LEFT SLIDE ASSY. REPLACED SLIDE AT FWD LT DOOR. ALL CHECKS ARE NOW NORMAL.SDR 2008UALA00442Lanyard · out of positionLANYARD FOR DOOR 2R IS NOT PACKED INTO SLIDEPACK AND EXTENDS ABOUT 2 FT. REINSTALLED LANYARD AND CHECKED SLIDE ARMING AND DISARMING POSITIONS, ALL NORMAL.SDR 2008UALA00462Light · inoperativeSEAT MOUNTED FLOOR PROXIMITY EMERGENCY ESCAPE LIGHT OUT AT SEAT 24C. REPLACED LIGHT ASSY.SDR 2008UALA00447Sill · corrodedR2 DOOR SILL PLATE HAS 3 SPOTS OF CORROSION AT FR 68. MAJOR REPAIR ACCOMPLISHED.SDR 2008UALA00405Slide · shortedTHE "EXT LOAD AFT LEFT" DISPLAYED DURING EMERGENCY LIGHT TEST. ELECTRICAL SHORT IN AFT SLIDE (RT). REPLACED AFT RT SLIDE. TESTED, PERFORMED NORMALLY. NO REPEATS.SDR 2008UALA00390Connector · looseEMERGENCY LIGHT TEST FAILS BATTERY AFT L. LOOSE CONNECTOR AT AFT EMERGENCY POWER SUPPLY. RESET/RESEATED CONNECTOR, TESTED NORMALLY.SDR 2008UALA00350Strap · out of positionPART OF SLIDE PACK IS HANGING FROM DOOR 1R WHILE THE DOOR IS CLOSED. D RING STRAP WAS OUTSIDE OF PACK ASSY, SECURED THE D RING STRAP, INSP SLIDE. ALL OK.SDR 2008UALA00367Computer · faultyON DEPARTURE FIRST OFFICERS PITCH TRIM DID NOT WORK. AIRCRAFT PITCHED UP UNTIL OVERRIDDEN WITH NOSE DOWN JOYSTICK COMMAND. CAPT PITCH TRIM WORKS NORMAL WHEN COUPLED WITH EITHER AUTOPILOT. ELAC2 FAULT. REPLACED ELAC2, OPS CHECKED GOOD.SDR 2008UALA00314Proximity Sensor · failedRTFL DUE TO A GEAR UPLOCK INDICATION PROBLEM. FAILURE OF NOSE L-G EXT PROX SENSOR 25GA. REPLACED SENSOR 25GA, PERFORMED GEAR SWINGS, ALL NORMAL OPS.SDR 2008UALA00316Wire · shortedCABIN EMERGENCY LIGHTS TEST FAILED EXT LOADS FWD L. WIRING SHORT IN SLIDE PACK. REPLACED SLIDE AT DOOR 1R. OPS CHECKED NORMALLY.SDR 2008UALA00318Epsu · faultyEPSU BATTERY EMER R FAULT FOUND WHEN TESTING EMERGENCY LIGHTS. FAULTY EPSU. REPLACED EPSU, OPS CHECKED NORMALLY.SDR 2008UALA00310Epsu · failedEMERGENCY LIGHTS TEST FAILED, FAULTS AFT LEFT BATTERY. EPSU FAILURE. REPLACED AFT LEFT EPSU, OPS CHECKED NORMAL.SDR 2008UALA00288Connector · looseEMERGENCY LIGHTS FAIL TEST SHOW BATTERY AFT LEFT. LOOSE CONNECTOR. RESEATED CONNECTOR. LIGHTS TESTED NORMAL.SDR 2008UALA00276Controller · faultyFLIGHT DIVERTED DUE FLIGHT DECK DOOR LOCK CYCLING OPEN, DOOR NOT SECURE. FAULT LIGHT ILLUMINATED. DOOR CONTROLLER MALFUNCTION. REPLACED DOOR CONTROLLER.SDR 2008UALA00252Structure · damagedUPPER FWD PART OF FUSELAGE DAMAGED WHERE IT MEETS RADOME. DAMAGE IS APPROX 1-4 IN BY 1-4 IN. PERFORMED MAJOR REPAIR AT LCQ.SDR 2008UALA00213Control Unit · malfunctionedCREW REPORTS LANDING GEAR DID NOT RETRACT AFTER T/O. PFR SHOWS 25GA FAULT, SERVICED NOSE GEAR STRUT, REPLACED LGCIU NR 2 ACCOMPLISHED A TEST FLIGHT WITH THREE SUCCESSFUL DEPLOY AND RETRACTIONS. A/C HAS NOT HAD THIS ISSUE SINCE JAN 15, 2008.SDR 2008UALA00253Sill · corrodedR2 DOOR SILL PLATE HAS CORROSION AT FASTENER HOLE LOCATION FWD END AT FR66 AND AT AFT END AT FR 69 ON OUTER RADIUS. PERFORMED MAJOR REPAIR AT LCQ.SDR 2008UALA00227Pressure Switch · failedFLIGHT DIVERTED DUE TO GREEN HYDRAULIC PUMP FAILURE. NR 1 ENG PUMP PRESS SWITCH FAILURE. REPLACED NR 1 ENG PUMP PRESS SWITCH, OPS CHECKED OK. ALSO REPLACED CASE DRAIN FILTER AS PRECAUTIONARY. FILTER WAS CLEAN WHEN REMOVED, NO CONTAMINATION.SDR 2008UALA00224Epsu · faultyLEFT AFT ENTRY DOOR EMERGENCY EXIT LIGHT HAS BATTERY FAULT. EPSU FAULTY. REPLACED EPSU.SDR 2008UALA00226Skin · damagedLIGHTNING STRIKE AT FRAME 12 ON RIGHT SIDE IS AT FWD EDGE OF SKIN PANEL. HOLE IS BURNED 100% OF SKIN ABOUT .125". ABOUT 50% BURN THROUGH FOR .25". MORE THAN 10% BURN THROUGH FOR .625". INTEGRITY NOT COMPROMISED. REPLACED ELEVATOR AND PERFORMED MAJOR REPAISDR 2008UALA00202Computer · malfunctionedRTFL WITH A FLIGHT MANAGEMENT COMPUTER FAILURE. *S/D* RESET FMGC 1 AND 2 AND CROSS LOADED, OK- UPDATED FMS DATA UA30801001 17JAN TO 24FEB. OPS CHECKING NORMALLY.SDR 2008UALA00251Oxygen Mask · faultyFWD OXYGEN MASK-CAPT SIDE WILL NOT TEST IN CRADLE. MASK WAS NOT POSITIVELY STOWED, THUS STILL ON. SWITCHED OUT CAPT/FO AND STOWED PROPERLY. ALL NORMAL.SDR 2008UALA00225Cover · missingSEATS 11C, 20C & 21C ARE MISSING THE EMERGENCY LIGHT LENS COVER. UNKNOWN PASSENGER DAMAGE. REPLACED LENS ON EMERGENCY LIGHTS ASSY AT ROW 11C, 20C, 21C. ALL LIGHTS OPERATIONAL.SDR 2008UALA00229Power Supply · dischargedEMERGENCY LIGHTS FAILS TEST. FAULTS EPSU UNIT LEFT. EPSU FAILURE. REPLACED EPSU, OPS CHECKED NORMAL.SDR 2008UALA00247Smoke Detector · faultySMOKE LAVATORY DETECTOR FAULT ECAM. SWAPPED DETECTOR WITH AFT LAV AND RETESTED, ALL NORMAL.SDR 2008UALA00205Power Supply · dischargedEMERGENCY EEL LIGHTS INOP FROM FRONT OF AC TO ROW 6. FAULTY EPSU. REPLACED EPSU, GROUND TEST NORMAL.SDR 2008UALA00206Cylinder · low pressureDOOR 1L EMERGENCY CYLINDER PRESSURE GAUGE READS ZERO. SERVICED CYLINDER TO FULL. NO REPEATS.SDR 2008UALA00180Wire Harness · damagedEEL LIGHT AT ROW 2 IS INOP. DAMAGE TO EEL SEAT HARNESS. REPLACED EEL LIGHT SEAT HARNESS AT ROW 2. OPS CHECKED NORMAL.SDR 2008UALA00177Control Handle · wornAFTER TAKEOFF TOOK 3 ATTEMPTS TO RAISE GEAR HANDLE. WEAR/PLAY IN THE LANDING GEAR CONTROL HANDLE. REPLACED THE LANDING GEAR CONTROL HANDLE. GEAR SWINGS ARE NORMAL.SDR 2008UALA00152Bottle · low pressureDOOR 2L ASSIST BOTTLE PRESSURE READS 7.0 PSI. SHOULD READ APPROX 1740 PSI. SERVICED DOOR ASSIST BOTTLE TO CORRECT PRESSURE.SDR 2008UALA00155Cover · out of positionDOOR 1L SLIDE COVER HAS MOVED AND PREVENTS SEEING PRESSURE GAUGE. REPLACED ENTIRE SLIDE PACK ASSY.SDR 2008UALA00156Diaphragm · leakingFOUND DOOR 2L DAMPNER AND EMERGENCY OPERATION CYLINDER READING "0" DURING 3 SVC. SUSPECT WEAK/LEAKING DIAPHRAGM AND/OR SEALS. REPLACED EMERGENCY OPERATION CYLINDER DIAPHRAGM AND SEALS. NO REPEATS SINCE ORIGINAL.SDR 2008UALA00125Pressure Switch · failedHYD RAT UPPER ECAM, LOWER ECAM HYD PAGE SHOWS RAT IN AMBER. FAULT IS CLEAR BUT HAS MANY HITS. RAT PRESSURE SWITCH FAILURE. REPLACED RAT PRESSURE SWITCH.SDR 2008UALA00092Oxygen System · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: OXY PRESS 1090 DECREASED 400 PSI SINCE DEN. UNKNOWN INDICATION ISSUE. SERVICED CREW O2 SYSTEM, NO LEAKS NOTED ANYWHERE IN THE SYSTEM.SDR 2008UALA00068Unknown · unknownCAPT LOST PARTIAL NAV DISPLAY FROM 80 MILE RANGE TO 10 RANGE. F/O LOST PARTIAL NAV DISPLAY. RMP FAILURE. SHOP COULD FIND NO IMMEDIATE FINDINGS -CHRONIC UNIT- UNIT WAS REPROGRAMMED BUT NOT YET REINSTALLED ON ANY A/C.SDR 2008UALA00078Unknown · unknownAFTER TAKEOFF BOTH DME'S VARIABLE +/- 20NM, EN ROUTE CONDITION WORSENED TO 100NM AT TIMES. PATCH WITH SAMC & C/B RESET DIDN'T RESOLVE CONDITION. CHECKED DME INTEROGATORS, BITE CHECK OK AND DME DISTANCE TO STATIONS ARE NORMAL. CHECKED AND RESET FMGC COMPUTERSDR 2008UALA00071Battery · dischargedEMERGENCY EXIT LIGHTS ABOVE DOORS FLASH ON-OFF. DISCO EFFECT ON ALL POWER TRANSFERS. WEAK BATTERY. FOUND AFT LEFT EMERGENCY EXIT BATTERY INOP. REPLACED BATTERY, CHECKS NORMAL AT THE GATE.SDR 2008UALA00067Carbon Seal · failedRTFL DUE TO UNIDENTIFIED FUMES ON CLIMBOUT. *S/D* IDG CARBON SEAL LEAKING MISTING OIL INTO BREATHER SYSTEM. REPLACED CARBON SEAL.SDR 2008UALA0039Hydraulic System · failedLANDED UNDER AMBER ALERT DUE TO A FAILED GREEN HYDRAULIC SYSTEM.SDR 2008UALA00039Safety Valve · failedLANDED UNDER AMBER ALERT DUE TO A FAILED GREEN HYDRAULIC SYSTEM. FAILED LANDING GEAR SAFETY VALVE. REPLACED LANDING GEAR SAFETY VALVE (49GA). PERFORMED GEAR CYCLES, OPS CHECKED NORMAL.SDR 2008UALA0002Wire · chafedEMERGENCY LIGHT TEST FAILS 3 SERVICE CHECK.SDR 2008UALA00002Wire · chafedEMERGENCY LIGHT TEST FAILS 3 SVC CK. FOUND WIRES CHAFED UNDER SEAT 4ABC. REPAIRED WIRES AT 4ABC, TESTS ALL NORMAL.SDR 2008UALA00053Epsu · failedEMERGENCY EXIT SIGN AT DOOR 1L AT FLOOR LEVEL INOP DURING EMERGENCY LIGHT TEST. EPSU FAILED. REPLACED EPSU, LIGHTS TEST OK.SDR 2008UALA00054Computer · faultyFLAPS ARE SLOW TO EXTEND. SFCC FAULTY. REPLACED SLAT FLAP CONTROL COMPUTER.SDR 2008UALA0001Battery · failedRIGHT OVERWING EMERGENCY BATTERY FAILS TEST.
SDR 2008UALA0005Bottle · reads lowBOTTLE AT DOOR 2R INDICATES LOW.
SDR 2008UALA0029Slide · out of positionCREW REPORT: SLIDE PACK 2R HAS FALLEN OFF.SDR 2008UALA00001Battery · failedRIGHT OW EMERGENCY BATTERY FAILS TEST. BATTERY FAILURE. REPLACED BATTERY, OPS CHECKED GOOD.