IAE V2527-A5
Service difficulty reports · 8,009
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013051303303Structure · damagedREMOVED RT WING FENCE DUE TO DAMAGE. REPLACED RT WING TIP FENCE IAW AMM.SDR UALA2013051403348Fire Detector · faultyFIRE LOOP A FAULT DISPLAYED ON UPPER ECAM SCREEN, ENG 1. REPLACED NR 1 FDIU REF MM 26-12-34 SYS CHECKS NORMAL WHILE AT THE GATE.SDR UALA2013051303314Seal · missingPILOTS REPORTED SOMETHING FLAPPING UNDER THE RT SIDE OTBD SPOILER. REMOVED DAMAGED PART OF SEAL. OTBD RT FLAP TRACK FAIRING INBD BLADE SEAL PARTIALLY MISSING. REPLACED SEALS ON RT OTBD FLAP FAIRING.SDR UALA2013051303301Screw · missingRAMP REPORTED BLOWOUT PANEL BORDER STRIP ON SECOND INBD CEILING PANEL MISSING TWO SCREWS. REPLACED MISSING SCREWS.SDR UALA2013051403351Battery · no testEMERGENCY LIGHT SYS AFT FAILED TEST. REPLACED BATTERY IAW AMM, OPS CHECKED OK.SDR UALA2013051403347Computer · faultedAFTER 3 HOURS IN CRUISE, FWD CABIN TEMP RAN AWAY & HAD TO RUN IT AT THE FULL COLD STOP. NO WARNINGS OR FAILURE MESSAGES ON PFR. PREVIOUS LEGS HIT P1 CONT 7HH. REPLACED P1 CONT IAW 21-61-34-000-001-A AND 21-61-34-400-001-A. OPS TEST PASSED.SDR UALA2013050903253Anti-Ice System · inoperativeAFT WASTE WATER DRAIN MAST HEATING SYSTEM(S) INOPERATIVE. SAMC COMMENTS: CIDS LIGHT ILLUMINATED.SDR UALA2013051303293Blade · damagedNR 2 ENGINE 1EA FAN BLADE FAILS TAP TEST MARKED. REPLACED NR 2 ENGINE 1EA BLADE.SDR UALA2013051303302Valve · leakingLONG TERM HYDRAULIC LEAK FROM DRAIN HOLES AFT OF FWD CARGO DOOR ACTUATOR. INSTALLED CARGO BAY DOOR SELECTOR VALVE ON FWD DOOR. LEAK CHECKED, OKAY.SDR UALA2013050903256Shock Absorber · lowLANDING GEAR SYSTEM DISAGREE MSG, RTFL. LG SYS DISAGREE MESSAGE DISPLAYED AND UNABLE TO RAISE LANDING GEAR AFTER TAKEOFF. CREW CYCLED GEAR THRU SEVERAL CYCLES AND NO HELP. LOUD BANGING NOISE HEARD AFTER GEAR CYCLING ATTEMPT. ACFT ALSO SHOWS IN FLT PHASE 8 SDR UALA2013050903240Skin · dentedFUSELAGE SKIN HAS 2 ADJACENT DENTS, JUST AFT OF FRAME STA 23 AT STR 22L. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER INSTALLED PER SRM 53-21-11 FIG 215 AT SMB C CHECK WRITE-UP E3138F.SDR UALA2013050903254Electronic Unit · failed1 AFT CABIN DEU-B HAS FAILED, CAUSING AFT F/A PANEL AND MANY CABIN LIGHTS TO BE INOP. REMOVED AND REPLACED DEU B. PERFORMED CIDS TEST. TEST OKSDR UALA2013050903252Seal · missingFOUND ON LT WING CANOE FAIRING, SEAL MISSING APPROX TWO FEET LONG BEHIND NR 1 ENGINE ABOVE PANEL 477A. REPLACED SEAL.SDR UALA2013051403350Power Supply · no testEMERGENCY LIGHTS WILL NOT TEST WITH MESSAGE EPSU COMM FWD LEFT DISPLAYED. REPLACED DOOR 1 LT EPSU AND BATTERY IAW AMM 33 51-38, OPS CHECKED EMERGENCY LIGHTS GOOD.SDR UALA2013050803216Stringer · corrodedFORWARD CARGO BAY STRINGER 43L HAS CORROSION BETWEEN FR 28 & FR 28. CORROSION OUT OF LIMITS. REPLACED STRINGER IAW SRM 51-42-11 PG 7. MAJOR REPAIR.SDR UALA2013050803223Screw · looseLOOSE SCREW ON INBD LEADING EDGE JUST BELOW SLATS. TIGHTENED LOOSE SCREW.SDR UALA2013050903238Stringer · corrodedFORWARD CARGO BAY STRINGER 43 LEFT, HAS SPOT CORROSION BETWEEN FR 24 & FR 28. CORROSION OUT OF LIMITS. REPLACED STRINGER IAW SRM 51-42-11 PG 7. MAJOR REPAIR.SDR UALA2013050703169Actuator · failedROW 24 ABC FAILED O2 MASK DROP CHECK. SEAT 24 ABC ARE INOP. NEED ACTUATOR ASSY ON O2 CONTAINER REF CMM 35-21-73A-001C. REPLACED ACTUATOR PCN 649-2759. PERFORMED OPERATIONAL CHECK OF MANUAL MASK RELEASE PER AMM 35-23-00-710-001-A. NO FAULTS. PLACARD REMOVSDR UALA2013050703170Power Supply · not seatedDURING 2 SVC CHECK OF EMERGENCY LIGHTS EPSU INT LOAD EMER L. RESEATED LEFT OVERWING POWER SUPPLY TESTED OK PER MM.SDR UALA2013050703200Windshield · defectiveRIGHT WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. - ANTI ICE PROG TEXT: ACCOMPLISH CHRONIC REVIEW. LAST LEG REPORT, RT WINDOW SENSOR GND. NO TIME TO FIX. INF- :SEE PTT SEQ #2406001 FOR WIRING TROUBLESHOOTING INFO. NO WIRING DISCREPANCIES FOUND. TSM TASKSDR UALA2013050703168Oxygen Mask · dislodgedON LANDING OXYGEN MASK FELL ROW 8ABC. STOWED MASKS AND ACCPLISHED DROP CHECK OF ALL CONTAINERS PER MT 35-003, OPS CHECKED GOOD.SDR UALA2013050803222Computer · faultyFUEL QTY CH 1 FAULT. REMOVED AND REPLACED FQIC IAW AMM 28-42-34. OPS CHECK GOOD.SDR UALA2013050703197Window · delaminatedFIRST OFFICER'S SLIDING WINDOW HAS DELAMINATION OUT OF LIMITS 4 INCHES WIDE PER AMM-56-12-11-06 AT AFT SIDE OF WINDOW. REMOVED AND REPLACED RIGHT SLIDING WINDOW PER MM 56-12-11.SDR UALA2013050803224Wire · shortedCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. FOUND MICROPHONE WIRE IS INTERMITTENT IN O2 BOX. WHEN WIGGLED, COMMS IS INTERMITTENT. REPLACED CAPTAIN'S OXYGEN MASK STOWAGE BOX REF AMM35-12-41-00-0-001 A. CHECKS OK REF AMM 35-12-41-710-001A.SDR UALA2013050703198Seat · defectiveF/O SEAT FWD AFT HAS A GRINDING FEEL ON THE TRACK BOTH WITH MANUAL AND ELECTRONIC FUNCTION. REPLACED FO SEAT ASSY PER MM, OPS CHECK GOOD.SDR UALA2013050703207Wire Harness · arcedLEFT WINDOW ANTI ICE DISPLAYED ON UPPER ECAM SCREEN. TWO POPS WERE HEARD AND SAW AN ARCING IN THE VICINITY OF THE SLIDING WINDOW WIRING. REMOVED AND REPLACED LEFT SLIDING WINDOW WIRE HARNESS WITH NEW HARDWARE PER ESPM 20-33-00, AMM 56-12-11, AWM 30-42-03 ANSDR UALA2013050603140Engine · stalledSTALL DISPLAYED ON UPPER ECAM SCREEN DURING OFF IDLE ACCELERATION. ENGINE NOT SHUTDOWN. STALL OCURRED AT 210 DURING LEVEL OFF. RAN CHECKLIST. DID NOT REOCCUR. HEARD AUDIBLE STALL. TROUBLESHOOT PER TSM 71-00-00-810-809-A. REPLACED INEENG PER MT 71-01-SDR UALA2013050703199Latch · brokenOXYGEN MASKS DROPPED AT 11 ABC. OXYGEN PANEL DOOR LATCH BROKE OFF DOOR. SECURED O2 PANEL AT 11 SEATS 11ABC. PERFORMED OPERATIONAL CHECK OF MANUAL MASK RELEASE OF ALL O2 MASKS. SEATS OK FOR SERVICE.SDR UALA2013050703164Blade · damagedNR 1 ENGINE FAILED VIBRATION TEST. FIRST STAGE FAN BLADES REMOVED PER MM. BLADE DAMAGE. BLADE AND DAMAGE IS OUT OF LIMITS PER 72-31-11-200-010-B. PER AMM MAX BLEND LIMIT IS .040, AREA BLENDED MEASURES .0625 DEEP. REPLACED NR 14 BLADE PER MM 72-13-11-400SDR USAA2013050700008Actuator · inoperativeRIGHT ENGINE HIGH EGT DURING TAKEOFF, AT APPROXIMATELY 800 FT, HEARD A BANG, RIGHT ENGINE EGT EXCEEDED MAXIMIUM TEMPERATURE OF 635 DEGREES. REMOVED AND REPLACED VSV ACTUATOR. PERFORMED BORESCOPE INSPECTION WITH NO FINDINGS. REMOVED AND REPLACED NR 2 ENGINE OUSDR UALA2013050703177Door · bentAIRCRAFT HAS LOUD SQUEAL IN COCKPIT UNABLE TO HEAR COMMUNICATIONS. ACP ACFT GRD PRESSURIZATION PER REQUEST OF TOMC. FOUND NO PRESSURE LEAKS IN FLT DECK WERE FOUND, SUSPECT REMOVAL OF DAMAGED EXTERNAL PWR DOOR DF262 WAS CAUSE FOR LOUD SQUEAL. EXTERNAL PWR DOSDR UALA2013050703180Smoke Detector · defectiveLAVATORY DET FAULT DISPLAYED ON UPPER ECAM SCREEN. - SMOKE FWD LAV SMOKE DET WILL NOT TEST. REPLACED FWD LAV SMOKE DETECTOR BITE TEST IS NOW GOOD, MSG HAS CLEARED.SDR UALA2013050703175Panel · dislodgedCEILING PANEL FELL DOWN SEAT POSITION 37 DEF. SECURED PANEL IAW ECRA 2523-01105 FOR 2D.SDR UALA2013050703179Control Panel · inoperativeCAPTAIN CANNOT HEAR OR TRANSMIT ON MINITEL. TRIED THREE DIFFERENT MINITELS. REPLACED AUDIO PANEL.SDR UALA2013050703176Hydraulic System · leakingFLUID DRIPPING FROM BOTTOM OF FSLG. REPLACED PTU, OP AND LEAK CHECKED GOOD.SDR UALA2013050703181B-Nut · leakingHYDRAULIC FLUID LEAKING FROM LEFT MLG. PUDDLE UNDER THE GEAR. FOUND B-NUT LOOSE ON LOWER BRAKE SERVO VALVE. SECURED B-NUT, NO LEAKS NOTED.SDR UALA2013050603158Hinge Pin · missingOXYGEN MASK DOOR ON FIRST OFFICER`S SIDE IS DAMAGED. FOUND OXYGEN MASK COMPARTMENT COVER MISSING HINGE PIN AT LEFT UPPER CORNER. REPLACED PIN.SDR UALA2013050303123Power Supply · failedWITH LOSS OF POWER, ONLY HALF OF EMERGENCY LIGHTS ILLUMINATE. REPLACED FWD EPSU AND BATTERY REF AMM 33-51-38. REPLACED MID CABIN LEFT BATTERY PER AMM 33-51-38. OPS CHECKED OK.SDR UALA2013050203079Power Supply · no testEMERGENCY LIGHT TEST FAILED. MESSAGE 'EPSU INT LOAD FWD L'. REPLACED FWD EPSU & BATTERY, OPS CHECKED GOOD PER AMM.SDR UALA2013050203065Bullnose · dentedRAMP REPORTED DENT IN LEFT BULLNOSE OF NR 3 SLAT. ACCOMPLISHED PERMANENT REPAIR IAW SRM.SDR UALA2013050303122Line · leakingHYDRAULIC FLUID DRIPPING FROM AFT OF AFT CARGO DOOR. REPLACED LEAKING TUBE ASSY AT AFT CARGO DOOR SELECTOR VALVE IAW MM 20-23-11-300-001-A. OPS AND LEAK CHECKED GOOD. OK FOR SERVICE.SDR UALA2013050103043Gust Lock · inoperativeL1 DOOR WILL NOT LOCK OPEN. REPLACED THE L1 DOOR STAY MECHANISM IAW AMM.SDR UALA2013050103044Transducer · failedFLIGHT CONTROL STATUS MESSAGE DISPLAYED ON THE LOWER ECAM SCREEN. INSTALLED REPAIRED FIRST OFFICER'S SIDE STICK ASSY & PERFORMED OP TEST TASK IAW 27-92-41-710-001-A. PERFORMED SAT AFS AND LAND TEST PER MM 22-97-00. A-C RETAINS CAT IIIB STATUS PER GMM 5-35-40SDR UALA2013050203074Pump · failedECAM CAUTION MESSAGE, ENGINE PUMP LOW PRESSURE. HYD SYSTEM QTY WENT TO ZERO INFLIGHT, GROUND CREW REPORTED MAJOR LEAK. REPLACED NR 2 ENGINE HYDRAULIC PUMP FOR YELLOW SYSTEM IAW MM, LEAK AND OPS CHECKED NORMAL.SDR UALA2013050203075Slide · faultyREPLACE NR 1R EVAC SLIDE. SLIDE AT DOOR 1R WAS MR25823, DASH OFF 2258. REPLACED SLIDE ASSY AS PER MM 25-62-44, OPS CHECKED GOOD. EMERGENCY LIGHT CONNECTOR ATTACHED AND ROUTED, NORMAL ECAM WARNINGS, EMERGENCY LIGHT TESTED OK. ACCOMPLISHED INSPECTION OF SLIDSDR UALA2013043003031Seat · looseENTIRE ROW 37 DEF IS LOOSE AND WIGGLES. FOUND FWD INBD FOOT LOOSE. TIGHTENED FOOT. SEAT ASSY SECURE.SDR UALA2013050203071Psu · unsecurePSU PANEL ABOVE SEATS 31DEF FALLING DOWN - NEEDS SECURED. RE-SECURED PANEL, OK FOR SERVICE.SDR UALA2013043003024Threshold · corrodedR2 DOOR THRESHOLD HAS CORROSION FR 66-68, S23-24R. FOUND OUT OF LIMITS. REMOVED AND REPLACED THRESHOLD IAW SRM 51-42-11 PARA 5, 6, 7 & 3. SRM 51-4 4-11 PG 1 SRM 53-41-14 PAGE 101. MAJOR REPAIR.SDR UALA2013043003030Hinge Bracket · brokenPOTABLE WATER SERVICE PANEL HAS BROKEN LATCH ANGLE. FWD LATCH IS STILL OPERABLE. BUT ANGLE THAT IT LATCHES TO IS BROKEN. MANUFACTURED ANGLE BRACKET IAW MT 52-024 REV B. BRACKET INSTALLED IAW ECRA 5341-01035.SDR UALA2013043003032Handset · inoperativeAFT F/A STATION CANNOT BE HEARD BY COCKPIT. REPLACED HANDSET.
Back to IAE V2527-A5