IAE V2527-A5
Service difficulty reports · 8,011
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012102206007Structure · damagedLEFT MLG DOOR WHEEL BUMP OUTER SURFACE HAS LIGHTNING STRIKE. REPAIRED PER SRM.SDR UALA2012102206043Computer · faultyELAC 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. - F-CTL. RESET BOTH ELAC 1 & 2. PERFORMED OPERATIONAL TEST OF ELAC 1 AND 2 PER AMM. NO FAULTS. ELAC 2 FAULT SHOWED AGAIN AT POWER TRANSFER. REPLACED ELAC 2 PER AMM, OPS TESTED OKAY. PERFORMED CAT III PER AMM, OSDR UALA2012102206044Bellows · damagedCAPTAINS SIDE STICK BOOT STARTING TO RIP. ITEM TEMP REPAIRED PER MT 27-031. RPLC'D CAPTAINS SIDE STICK BELLOWS.SDR UALA2012102306054Slide · unserviceableLEFT OFF-WING SLIDE ENCLOSURE PANEL BALL LOCKS ARE PAINTED. SLIDE NEEDS TO BE REPLACED. (REF AMM 25-62-42 -401, MT 25-029, AND M&E BULLETIN 12-011. REPLACED SLIDE AND OPS CHECKED.SDR UALA2012101805955Ram Air Turb · leakingHYD LEAK FROM NEW RAT AND PUMP.SDR UALA2012101805962Target · faultyCREW REPORTED LANDING GEAR WOULD NOT RETRACT. FOUND TARGET LEVERS ITEM 100 & 120 REF IPC 32-21-11-14, EXTREMELY WORN AND SUPPORT ITEM 70 HAD A LOOSE ATTACHMENT BOLT REF IPC. SECURED BOLT ON SUPPORT AND REPLACED 2EA TARGET LEVERS FOR SYS 1 & 2. ALSO REPLACEDSDR UALA2012101805953Control Unit · malfunctionedOPERATIONAL TEST OF SDCU 10WQ FAILS. CABIN INDICATIONS ARE NORMAL, STEP 4. A. NO FLIGHT DECK EFFECTS OCCUR (NO MSTR CAUTION, CONT CHIME OR ECAM ALERT) FOR ANY & ALL LAVS. REPLACED SDCU PER AMM, NO HELP. RE-INSTALLED ORIG UNIT. TESTED SYSTEM. TESTED SYSTEMSDR UALA2012101705942Trunnion · shearedTRUNNION ASSY FOUND SHEARED AT LOWER END ON R1 DOOR. COMPLETED INSTALLED SPRING ROD. OPS OF DOOR NORMAL.SDR UALA2012101805958Carpet · out of positionDOOR 2L WILL NOT ARM AND APPEARS TO BE JAMMED. FOUND CARPET COVERING GIRT BAR FITTING. REPOSITIONED CARPET AND DOOR ARMED WITH NO FURTHER PROBLEMS.SDR UALA2012101805959Seal · tornSEAL BELOW LEFT OVERWING SLIDE TORN. PERFORM INTERIM REPAIR PER ECRA 5330-04349 PART 1.SDR UALA2012101805951Unknown · malfunctionedAFT LAV SMOKE ALARM SOUND THEN TURNED OFF ON ITS OWN. NO SMOKE OR FUMES WERE DETECTED. TESTED SYSTEM REF AMM 26-17-00 PG 503 AND EC-RA 2617-01002. SYSTEM PASSED TEST.SDR UALA2012101905977Engine · bird ingestionFOUND EVIDENCE OF BIRD STRIKE ON NR 1 ENGINE INLET AT 2:00 POS AND 1:00 ON ENGINE CORE. FOUND NO EVIDENCE OF RUBBING ON THE FAN ATTRITION LINERS. FOUND NO DAMAGE ON THE FAN BLADES. NI ROTATION OK ENGINE NR 1 SERIAL V10483 REQUIRES LPC AND HPC BORESCOPE INSPSDR UALA2012101805961Seat · looseTHE 32ABC WHOLE ROW IS LOOSE AND IS A ROCKER. SECURED SEAT IN TRACK.SDR UALA2012101805960Unknown · malfunctionedNOSE WHEEL STEERING PULLS TO THE LEFT REQUIRES CONSTANT TILLER INPUT. ACCOMPLISHED CHECK PER T/S MANUAL 32-51-00-810-823-A. NO DEFECTS NOTED. WINDS ARE GUSTING AT 26 KNOTS AT ORD. CREW COMMENT WOULD BE APPRECIATED.SDR UALA2012101605889Unknown · faultyEMERGENCY LIGHT AT SEATS 25ABC INOPERATIVE. INSPECTED FOR BROKEN WIRES, NONE FOUND. REMOVED AND REPLACED BULBS, NO HELP. SUSPECT BAD SOCKET AT THE SEAT.SDR UALA2012101705936Seal · leakingNR 2 ENGINE CHG DUE TO TOWER SHAFT-GEARBOX MATING SURFACE OIL LEAK. ENGINE DOWN FOUND. WILL NEED SEALS AND PLUGS PRIOR TO FLT HAVE ACCESS TO INSTALL PARTS ONCE ENGINE IS UP. REMOVE AND INSTALL ENGINES REF MT71-017. REPLACED NR 2 ENG IAW MT71- 017. ACCOMSDR UALA2012101705947Accumulator · failedEMERGENCY GENERATION TEST FAILED, FOUND BLUE ACCUM PRESS ZERO. REMOVED AND REPLACED BLUE POWER ACCUMULATOR PER MM, OPS CHECKS NORMAL.SDR UALA2012101805973Battery · faultyWHEN PERFORMING EMERGENCY LIGHT TEST ACCT DOOR 2R SLIDE INSTALLATION, GOT CIDS MESSAGE EMERGENCY BATTERY FWD LEFT. REPLACED FWD LEFT EMERGENCY LIGHT BATTERY. EMERGENCY LIGHT TEST CHECKED OK.SDR UALA2012101605895Battery Pack · failedCABIN EMERGENCY LIGHT TEST FAILED. EPSU BATTERY EMERGENCY L OF FWD FLIGHT ATT PANEL. REPLACED BATTERY PACK.SDR UALA2012101705930Oxygen Mask · faultyOXYGEN BOTTLE MISSING-USED AT 37A. OXYGEN PRESSURE WAS GOOD. MASK WAS BAD. REMOVED AND REPLACED 02 MASK.SDR UALA2012101605907Plate · defectiveDOOR 1L HAS PLASTIC BLOCKING ARMED INDICATOR. REPLACED THE ARMED - DISARMED SIGHT GLASS PLATE.SDR UALA2012101605908Unknown · faultyF/O RUDDER PEDALS DON`T RETRACT WITHOUT PULLING THEM WITH YOUR FEET.SDR UALA2012101505884Warning System · false activationL WINDOW ANTI-ICE ECAM. WHC1 TEST OK, NO FAULTS NOTED. CHECKED LT SLIDING WINDOW PRIMARY AND SPARE TEMP SENSOR RESISTANCES. BOTH SENSORS RESISTANCES WITHIN LIMITS AT 590-600 OHMS.SDR UALA2012101605888Rod End · out of adjustDOOR 2R SLIDE ARM LT CONT FLASHES. HANDLE MOVING. VIDEO DOCUMENTATION. ACFT NEEDS FLT CHECK. ADJUSTED FLEX CONTROL ROD LOWER ROD END PER AMM. CHECK DOOR RIG AND GAPS REF MM 52-13-22 AND SWITCH REF MM 52-71-00 ACCOMPLISHED. FOUND GIRT BAR ARMING MECHANISMSDR UALA2012101505867Floorboard · damagedIN REFERENCE TO SMC2, FLOORBOARD WAS FOUND TO BE SPONGY AND SUSPECT CRACKING-FLEXING. DOES NOT MEET CRITERIA OF MT 53-007 OR SRM 53-02-00 TO CONTINUE IN SERVICE. REMOVED AND REPLACED FLOOR PANEL 151DF FWD OF DOOR.SDR UALA2012101505874Cover · brokenEMERGENCY LIGHT LENSE COVER BROKEN SEAT 21C (RED). REPLACED LIGHT ASSY, EMERGENCY LIGHT TEST OK.SDR UALA2012101505878Interface Unit · malfunctionedELEC PROBLEMS, RTFL. NEED TO CHG NR 2 EGIU PER FIM 24-20-00-810-831-A. REPALCED NR 2 EGIU PER MM. NEED TO REPLACE (4XU2)GLC AUX CT L NR 2 RELAY, PER FIM 24-20-00-810-832-A. REPLACED (4XU2) GLC 2 AUX CONTROL RELAY. REPLACED 3XU2 SWITCH RAN 124269 ENGINE TWSDR UALA2012101505871Panel · damagedCREASE IN PANEL 314AR FOUND ON WALKAROUND. MAJOR REPAIR ACCOMPLISHED: REFER TO ECRA 5241-01025. OK FOR 2 CYCLES. INSTALLED DOUBLER.SDR UALA2012101505843Light · inoperativeR2 DOOR CABIN PRESSURE RED WARNING LIGHT INOPERATIVE. ACCOMPLISHED MT 52-011 ALL LIGHTS, OPS CHECKED NORMAL.SDR UALA2012101505844Light · inoperativeL2 DOOR CABIN PRESSURE RED WARNING LIGHT INOPERATIVE. ACCOMPLISHED MT 52-011, ALL LIGHTS OPS CHECKED NORMAL.SDR UALA2012101605902Seal · detachedOUTER SEAL ON DOOR 1L WINDOW IS PARTIALLY DETACHED. SEAL REPLACED.SDR UALA2012101505872Fan · cloggedLOUD HUM WITH VIBRATION IN AFT GALLEY AREA. CONNECTOR REMOVED AND SECURED FROM FAN 35HN. REMOVED AND REPLACED VENTILATION EXTRACTION FAN PER MM. FOUND OLD VENT FAN CLOGGED. CLEANED INLET AND EXHAUST DUCT. OPS CHECKS NORMAL.SDR UALA2012101205814Strip · unsecureAFT PIT BLOWOUT PANEL PROTECTIVE STRIP HANGING DOWN. REMOVED AND REPLACED BLOW OUT PANEL AS PER MM.SDR UALA2012101105786Striker · failedCOCKPIT DOOR 'FAULT' LIGHT AND DOOR CONTROLLER 'TOP STRIKE' OR 'LOWER STRIKE' LIGHT IS ON. REPLACED LOWER DOOR STRIKER, FAULT MESSAGE CLEARED. DOOR LOCKS CHECKED GOOD.SDR UALA2012101205807Cap · damagedLIGHTNING STRIKE HOLE IN RUDDER TIP. LIGHTNING STRIKE DISCOVERED ON RUDDER UPPER CAP APPROXIMATELY ONE INCH FWD OF TRAILING EDGE (HOLE IN BOTH LEFT AND RIGHT SIDE). HOLE DAMAGE ON RT SIDE IS APPROX 1.4 IN L BY 1 IN WIDE. DAMAGE OF LEFT SIDE IS APPROX 3-8 INSDR UALA2012101205808Lens · crackedRIGHT AFT OVERWING EMERGENCY LIGHT LENS CRACKED. REPLACED LENS BY FBO MECH. NO FURTHER DEFECTS NOTED.SDR UALA2012101105777Bottle · missingOXYGEN BOTTLE MISSING, USED AT R2 DOOR. REPLACED CYLINDER.SDR UALA2012101105785Case · peelingNR 1 ENGINE AT 1130 POSITION LOOKS LIKE SKIN OF ENGINE IS PEELING AND A COUPLE OF RIVETS POPPED. PERFORMED INTERIM REPAIR PER ADVANCE REVISION MT78-14B 13SEP2012 AND ECRA 7830-02545.SDR UALA2012101105788Feeder Cable · dirtyALL CABIN LIGHTS FLICKERING ON GROUND WITH ENGINES RUNNING. CHECKED BOTH ENGINE IDG FEEDER CABLES AT PYLON PER MT24-002. LEFT SIDE FOUND CLEAN AND RT SIDE DIRTY. CLEANED. BOTH ENGINES IDG TERMINAL LUGS CHECKS GOOD. PRECAUTIONARY RESET CIDS DIRECTOR AND DESDR UALA2012101005756Actuator · excess playMAIN WW DOOR ACTUATOR HAS PLAY. REPLACED LEFT MLG DOOR ACTUATOR, OP CHECK AND LEAK CHECK OK.SDR UALA2012101005758Control Valve · faultyCABIN TEMP CONTROL TEST FAULTS. NEW VALVE INSTALLED, OPS AND LEAK CHECKED GOOD.SDR UALA2012101005757Gearbox · out of toleranceGEARBOX EXCEEDED, NEEDS REPLACEMENT. SYSTEM TEST OF CONTROL LEAK CHECK, INSTALLED AND BOLTS REPLACED.SDR UALA2012101005753Bracket · damagedFORWARD CARGO DOOR AFT VERTICAL EDGE OF CARGO DOOR PRESSURE SEAT BRACKET MISSING APPROX ONE AND A HALF INCH. PCN 110-3244 & SRM 53-21-29 PG55 ITEM 5A. REPAIRED THE BRACKET PER SRM.SDR UALA2012101005760Control Cable · failedFIRST OFFICER'S RUDDER PEDAL ADJUSTMENT KNOB INOPERATIVE. -CABLE BROKE FROM THE LEVER, UNABLE TO ADJUST THE RUDDER PEDALS AT ALL. REPLACED CABLE PER MM.SDR UALA2012101005763Handle · unsecureCARGO DOOR OPEN EICAS, RTFL. FOUND AFT CARGO DOOR NOT RECESSED AND FAIRED WITH CARGO DOOR SKIN. HANDLE WAS STICKING OUT THREE QUARTERS OF AN INCH. CYCLED DOOR AND SECURED DOOR HANDLE RECESSED FLUSHED TO DOOR SKIN. DOOR HANDLE FLAP DOES ENGAGE AND LOCKS HANSDR UALA2012101205815Oxygen Bottle · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CONFIRMED PRESS DOWN TO APPROX 980 PSI. REMOVED AND SERVICED CREW BOTTLE PER AMM. OPS AND LEAK CHECKS GOOD. SAFETIED VALVE OPEN AFTER BOTTLE RE-INSTALLED.SDR UALA2012101205820Computer · malfunctionedAIRCRAFT CONTINUES TO NOSE UP PITCH AFTER RELEASING SIDE STICK .5DG PER SECOND. REPLACED ELAC 2 PCN 482-9572 PRECAUTIONARY. ACP TSM 27-30-810-853-A. WIRING CHECKS OK, REPLACED NR 2 ELAC PER MM.SDR UALA2012101105787Exhaust Duct · crackedTWO INCH CRACK IN SHEETMETAL IN ENG NR 2 AT 12.30 POSITION IN EXHAUST END. STOPPED DRILLED PER MT78-00. CRACK BEYOND ALLOWABLE MM LIMITS. REPLACED CNA MM 78-11-11.SDR UALA2012101005751Skin · damagedRIGHT WING FUEL TANK LANDING 640MB HAS 1 EA MISDRILLED FASTENER HOLES. REPAIRED HOLE IAW ECRA 5720-02330 WITHOUT DEVIATION.SDR UALA2012101005761Clamp · deterioratedRT WING EMERGENCY SLIDE HAS 3 DETERIORATED CLAMPS. REMOVED AND REPLACED OFF WING SLIDE ASSY RT WING. INSTALLATION COMPLETE.
Back to IAE V2527-A5