IAE V2527-A5
Service difficulty reports · 8,011
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2527A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012071803891Slide · failedDOOR 2L ESCAPE SLIDE REMOVED FOR TROUBLESHOOTING. REPLACED DOOR 2L ESCAPE, SLIDE PACK ASSY.SDR UALA2012071803900Light · no testEMERGENCY LIGHT FAILED TEST. REPLACED DOOR ESCAPE SLIDE PACK ASSY REF AMM. ACCOMPLISHED EMERGENCY LIGHT TEST REF AMM 33-51-00-501 AND TESTED OK.SDR UALA2012071803901Liner · damagedNR 1 ENGINE MISSING 1.5 INCH BY 1.5 INCH SECTION IN THE FAN CASE ATTRITION LINER AT 1 O'CLOCK POSITION. REPAIRED PER MT 72-017 REF PTT 6822015 AND PTT 6822019.SDR UALA2012071603832Apu · faultyAPU HAS A VERY LOUD HIGH PITCH SCREAM-WHISTLE WHEN ON. BLEED VALVE POSITION DOES NOT MATTER. APU EXTREMELY LOUD. INLET AND EXHAUST NO OBVIOUS DISCREPANCIES. BLEED ON OR OFF NO CHANGE. FOUND SMALL AMOUNT OF METAL ON MAIN DRAIN CHIP DETECTOR. REPLACED APU.SDR UALA2012071603815Battery · no testPERFORMED EMERGENCY LIGHT TEST PER 3SVC, FOUND EPSU BATTERY FWD LT DISPLAYED. REPLACED BATTERY, TESTED NORMAL.SDR UALA2012071703848Oxygen Mask · failedFIRST OFFICERS OXYGEN MASK DOES NOT REPRESSURIZE AFTER SELF TEST. REPLACED FIRST OFFICERS OXYGEN MASK STOWAGE BOX, LEAK CHECKED GOOD. OPS CHECKED NORMALSDR UALA2012071803879Actuator · faultedAUTO FLT 'YAW DAMPER 1' DISPLAYED ON UPPER ECAM SCREEN. NR 1 YAW DAMPER INOPERATIVE. REPLACED ACTUATOR.SDR UALA2012071803881Oxygen Mask · unwanted deployON CLIMB OUT PASS O2 MASKS IN SEATS 1EF DEPLOYED. MASKS HAD TO BE SECURED WITH DUCT TAPE. REPACKED MASK PER AMM. PERFORMED. ACCOMPLISHED DROP TEST.SDR UALA2012071603830Ground Stud · looseRIGHT FWD CABIN DOOR ECAM ILLUMINATED 4 TIMES DURING DESCENT. DOOR OPS NORMAL. FOUND GROUND STUD 2050VN LOOSE CAUSING INTERMITTENT ECAM DOOR WARNING FAULT. SECURED GROUND WIRE, FWD RT DOOR INDICATION CHECKS NORMAL.SDR UALA2012071603831Slide · faultyEMERGENCY LIGHT FAILED TEST. FAULTS EXTERIOR AFT LEFT LOAD. TROUBLESHOT PER TSM 33-51-00 PG256 AND MT33-01. BOTH ORIGINAL SLIDES ARE BAD.SDR UALA2012071603828Flap System · malfunctionedFLAPS LOCKED, ALIGNMENT FAULT DISPLAYED ON UPPER ECAM SCREEN F-CTL. TROUBLESHOT REF MT AND TSM TASK. RT APPU WAS OUT OF TOLERANCE. REPLACED RT APPU PER MM. RAN FLAPS WITH NO FAULTS.SDR GTIA20120713456Accumulator · low pressureR2 SERVICE DOOR OPENING ACCUMULATOR REQUIRES N2 SERVICE. SERVICED R2 DOOR OPENING ACCUMULATOR IAW AMM 52-10-00-614-001-A.SDR UALA2012071303784Diaphragm · damagedMAIN ENTRANCE DOOR ASSIST BOTTLE READS 0 PSI. REPLACED DIAPHRAGM.SDR UALA2012071303785Oxygen Mask · unwanted deployDUE TO INADVERTENT O2 MASK DROP AT ROW 20ABC, MT 35-003 COMPLIED WITH. ACCOMPLISHED O2 SYSTEM RELEASE CHECK PER MT35-003 AND AMM 35-23-00-710-001, CHECKED GOOD.SDR UALA2012071303797Duct · cloggedCOCKPIT HARD TO COOL ALL PHASES OF FLT. FOUND FLT DECK TEMP SENSOR REFERENCE AIR DUCT CLOGGED. CLEANED DUCT. PERFORMED OPS CHECK PER MM. SYSTEM OPS NORMAL.SDR UALA2012071203773Computer · faultyON TAKEOFF, CLIMB-OUT HAD TO USE EXCESSIVE FORWARD STICK INPUT TO KEEP PITCH FROM INCREASING. REPLACED ELAC 2. REPLACED ELAC 2 AS PER MM, CHECKED GOOD PER MM. ACFT IS FULL LAND III CAPABLE.SDR UALA2012071303793Outflow Valve · faultedHEARD & FELT LOW FREQUENCY RUMBLE. NO PRESSURE DIFFERENCES OFF ENGINE BLEED AIR. CPC 2 SYS IN CHARGE. REPLACED AVIONICS DUCT PER AMM. PRESSURIZED ALL DUCTS AND CHECKED FOR ADDITIONAL LEAKS -NONE FOUND. PERFORMED AVIONICS EQUIPMENT VENTILATION ADJUSTMENT ASDR UALA2012071103714Static Port · damagedSCRATCH IN EXTRA CRITICAL RVSM STATIC PORTS AREA L SIDE OF FUSELAGE. SCRATCH IS 2 1-2 INCHES LONG AND 1 INCH ABOVE FIRST OFFICER STATIC PORT, DEPTH OF SCRATCH IS 0.0005 WHICH IS OUT OF ALLOWABLE DAMAGE LIMITS PER MM. LIGHTLY BURNISHED DAMAGED AREA REF SRMSDR UALA2012071103712Battery Pack · failedEMERGENCY LIGHT TEST HAS FAILED MESSAGE EPSU BATTERY FWD LT. REPLACED BATTERY PACK.SDR UALA2012071103740Bushing · wornFOUND FWD HINGE BUSHING ON RT AFT NLG DOOR WORN. REPLACED DOOR.SDR UALA2012071203772Skin · scratchedSCRATCH ON L2 DOOR SKIN 11.25 INCH BELOW DOOR HANDLE CUT OUT, 14 INCHES AFT OF LEADING EDGE OF DOOR. SCRATCH IS VERTICAL AND 1.75 INCHES LONG. SCRATCH IS 2.25 INCHES AFT OF NEAREST RIVETS. REWORKED SCRATCH PER SRM. ALODINED AND PRIMED AREA. WITHIN LIMITS SDR UALA2012070903673Battery · no testDURING 3SV EMERGENCY LIGHT CHECK, FAULTED EMERGENCY BATTERY RIGHT, ON CIDS PANEL. REPLACED RT OVERWING POWER SUPPLY BATTERY, OPS AND TESTED NORMAL PER AMM.SDR UALA2012070903680Oxygen Box · brokenDURING OXYGEN MASK DROP TEST, FOUND SEATS 28 DEF O2 PANEL PARTS BROKEN, PANEL WILL NOT RESET. FOUND DOOR ACTUATOR BENT AND JAMMED. REPLACED 02 BOX AND PERFORM DROP TEST PER MM. OPS CHECKED GOOD.SDR UALA2012070903682Oxygen Box · damagedDURING DROP TEST, FOUND SEATS 2AB O2 PANEL RESET BUTTON WILL NOT ENGAGE. REPLACED 02 BOX AND PERFORM DROP TEST PER MM. OPS CHECKED GOOD.SDR UALA2012070903679Oxygen Mask · detachedO2 BOTTLE ABV SEAT 37E, MASK IS NOT ATTACHED. REPLACED O2 BOTTLE.SDR UALA2012071103736Indicator · inoperativeRUDDER TRIM POSITION INDICATOR INOP. REPLACED RUDDER TRIM INDICATOR.SDR UALA2012070903668Battery · no testPER 3 SVC ACFT FAILS EMERGENCY LIGHT TEST FOR FWD LEFT BATTERY. REPLACED LEFT FWD EMERGENCY LIGHT BATTERY. TEST OP CHECKED OKAY.SDR UALA2012070903660Skin · dentedEXTERNAL FUSELAGE DENTED 4 INCHES AFT OF FR 82 APPROX .5 INCH UP FROM STRINGER 2R. MAJOR REPAIR ACCOMPLISHED: EVALUATED DENT AND FOUND IT OUT OF LIMITS OF SRM. CUT OUT DAMAGE AND FABRICATED AND INSTALLED EXTERNAL DOUBLER REPAIR REF SRM 53-51-11 FIG 203 PG 21SDR UALA2012070903661Skin · dentedEXTERNAL FUSELAGE DENTED .5 INCHES AFT OF FR 82 AND 1.75 INCH LEFT OF STRINGER 1L. MAJOR REPAIR ACCOMPLISHED: EVALUATED DENT AND FOUND IT OUT OF LIMITS OF SRM. CUT OUT DAMAGE AND FABRICATED AND INSTALLED EXTERNAL DOUBLER REPAIR.SDR UALA2012070903662Skin · puncturedEXTERNAL FUSELAGE PUNCTURED 3.5 INCH BY 0.5 INCH BETWEEN FRAMES 80-81 AND BETWEEN STRINGERS 1L-1R. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE AND ACCOMP NDT OF CUT OUT. NO CRACKS FOUND. CUT OUT MEASURED AT 3.4 INCH BY 1.6 INCH. FABRICATED AND INSTALLED EXTESDR UALA2012070903663Computer · faultyRUDDER TRIM ISSUE, RETURNED TO FIELD. RT AILERON SHOWS FULL DOWN DEFLECTION ON FLT CTL PAGE, AC IN 3 DEG LT BANK. FUEL LOAD IS BALANCED, ENGINE PARAMETERS NORMAL. REPLACED BOTH ELAC'S PER MM, OPS NORMAL AND COMPLETED CATIII CHECK.SDR UALA2012070903686Skin · dentedHORIZONTAL STABILIZER DENT RIGHT LEADING EDGE OUTBOARD TIP APPROX 8 INCHES. PERMANENT REPAIR ACCOMPLISHED IAW SRM 55-14-11 FIG 203.SDR UALA2012070903687Spar · crackedNR 1 ENGINE PYLON INBD SPAR ANGLE CRACKED NEAR RIB 5. STOP DRILLED CRACK REF SR M54-50-00, WELD PER PMS 01-04-21. PER SRI54-50-00 PARA 3B TABLE 103. SPAR ANGLE REPLACED PER SRM 51-42-11.SDR UALA2012070903696Valve · leakingLARGE HYDRAULIC LEAK COMING FROM AFT WING TO BODY FAIRINGS LT AND RT AND CENTER. ALSO COMING FROM GEAR DOORS. LOCATED LEAK CLEAN AREA. REPLACED YELLOW SYSTEM PRIORITY VALVE. SERVICED YELLOW SYSTEM TO HALF FULL FOR ACCOMPLISHING LEAK CHECK.SDR UALA2012071103725Speaker · failedCOCKPIT TO AFT GALLEY COMM ALERT INOP. PA ALSO INOP AFT GALLEY. REPLACED AFT GALLEY LOUD SPEAKER, OPS CHECKED OK.SDR UALA2012070603643Actuator · activatedNR 2 ENGINE DRY MOTOR AND LEAK CHECK. REMOVED AND REPLACED HPT AND LPT ACTUATOR.SDR UALA2012070903657Skin · dentedEXTERNAL FUSELAGE DENT AT FR 17 AND STR 33R WAS FOUND OUT OF SRM LIMITS. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE AND ACCOMP NDT OF CUT-OUT AND EXISTING FASTENER HOLES FOR CRACKS. NONE FOUND. FABRICATED AND INSTALLED EXTERNAL DOUBLER REPAIR REF SRM 53-11-1SDR UALA2012070603637Ballast · failedFLIGHT ATTENDANTS REPORTED AN ELECTRICAL ODOR IN AFT GALLEY. INSPECTED AFT GALLEY ELECT COMPONENTS, COFFEEMAKERS, OVENS, WORK LIGHTS, FOUND BURNED BALLAST FOR 24LG RT ENTRY LIGHT AT DOOR 2. DISCONNECTED BALLAST AT 7206VC DISCONNECT, VENTILATED CABIN TO DISSISDR UALA2012070603644Diaphragm · failedR-1 DOOR BOTTLE READS 'O' PSI. REMOVED AND REPLACED R-1 DOOR ASSIST BOTTLE DIAPHRAGM, SERVICES R-1 DOOR ASSIST BOTTLE.SDR UALA2012070603631Attach Fitting · corrodedFWD LAVATORY ATTACH POINT AT FLOORBEAM Y518 CORRODED. REPLACED FWD LAV ATTACH POINT BEAM Y518 PER SRM ON PEMCO NR 5072N00468.SDR UALA2012070503621Outflow Valve · faultySKIN AIR EXTRACT EICAS, RTFL. CREW REPORTED NORMAL PRESSURIZATION. REPLACED AEVC AND SKIN AIR OUTLET VALVE AND ACCOMPLISHED OPERATIONAL TEST OF VENTILATION SYSTEM, ALL TESTS PASS.SDR UALA2012070503587Contactor · faultyON FINAL APPROACH, FLIGHT ATTENDANTS SMELLED A SMOKE ODOR BETWEEN OVERWING EMERGENCY EXIT ROW AND ROW 9. NO VISIBLE SMOKE, ONLY ODOR. FO ND DISPLAY INOP. CHATTERING BRAKES, LAX WILL SUPPLY EFS FOR ENGINE RUNS, FBO WORKING ITEMS. REF LOG 1 ON CHATTERING RELSDR UALA2012070503609Slide · faultyR1 DOOR BUSTLE IS NOT COMPATIBLE WITH SLIDE CONFIGURATION. REMOVED AND REPLACED R1 DOOR SLIDE PER AMM. DECORATIVE COVER AND DOOR RE-ARM ACCOMPLISHED ON TASK CARD 4R2590151.SDR UALA2012070503619Cylinder · faultyL2 DOOR PERCUSSION MECHANISM OF DOOR DAMPER EMERGENCY OPERATION CYLINDER HELICOIL OF KNURLED SCREW UNTHREADED WITH SCREW DURING DISARM PROCEDURE. REPLACED L2 DOOR DAMPER EMERGENCY OPERATION CYLINDER, OPS CK GOOD.SDR UALA2012070503614Controller · faultyCFDS TEMP CONTROL TEST IN CDU FAULTS P1 AND P2 CONTROLLERS. REPLACED NR 1 PACK TEMP CONTROLLER (7HH) PER MM. DURING OPS TEST OF CABIN TEMP CONTROLLER, FAILS NR 1 PACK RAM AIR IN ACTUATOR (8HH).SDR UALA2012070303557Slide · damagedNR 1 LEFT EVACUATION SLIDE DMAGED, REPLACED NR 1 LT EVACUATION SLIDE IAW A32 AMM 25-62-44 ON TASK CARD 5121N00245.SDR UALA2012070303558Oxygen Mask · brokenRT CREW O2 AFT MASK HAS CONTROL SLIDE BROKEN. REMOVED AND REPLACED RT CREW AFT O2 MASK IAW MM ON TASK CARD 5121N0002.SDR UALA2012070503607Oxygen Mask · leakingFIRST OFFICERS OXYGEN HARNESS FAILS TO INFLATE AND IS LEAKING. REPLACED 2ND OBSERVER MASK ASSY.SDR UALA2012070303537Servo Control · malfunctionedVIBRATION IN CLIMB, FLIGHT DIVERTED. REPLACED BOTH RIGHT ELEVATOR SERVOS. OPS NORMAL. REPLACED RT BLUE ELEVATOR SERVO CONTROL UNIT, NOISE IS STILL PRESENT AND FELT IN AFT CABIN. REPLACED RIGHT YELLOW SERVO CONTROL. THERE IS STILL HYD CHATTER. MAY BE NORSDR UALA2012070303556Oxygen Mask · damagedRT CREW O2 AFT MASK HAS CONTROL SLIDE BROKEN. REPLACED RT AFT CREW O2 MASK PER AMM 35-12-41 ON PEMCO NR 5121N00021.
Back to IAE V2527-A5