Pratt & Whitney Canada PT6A-67D
Service difficulty reports · 1,812
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6A67D' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6A67D' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA120309003Switch · out of adjust(CAN) THROUGH APPROX. 14000, 3.5 DIFF "CABIN DOOR ILLUMINATED". THEN ON APPROACH CABIN DOOR LIGHT EXTINGUISHED, APPROXIMATELY 0.5 DIFF. SYS INVESTIGATED AND ADJUSTED CABIN UPPER DOOR SWITCH. SYS FUNCTION TESTED, ALL PROVED SATISFACTORY.SDR CA120228012Bearing · failed(CAN) EIR PT6A 2012-022, DURING CLIMBOUT THERE WAS A LOUD BANG AND THE ENGINE WAS SHUTDOWN. O/H CONFIRMED THAT THE ENGINE HAD SUFFERED A BEARING FAILURE. AFTER REMOVAL OF THE ACCESSORY GEARBOX ASSY IT WAS NOTICED THAT THE NR 1 BEARING WAS BROKEN CAUSING SECOSDR 29GA2012022293671Mount · crackedDURING MAGNETIC PARTICLE INSPECTION, DISCOVERED ENGINE TRUSS MOUNT WELD AREA CRACKED AND TRUSS TUBE CHAFED. PERFORMED WELD REPAIR TO ENGINE MOUNT ATTACH POINTS WELD AREAS AND ENGINE TRUSS TUBE IN ACCORDANCE WITH FAA APPROVED DATA.SDR CA120206001Bracket · bent(CAN) THE ACFT HAD A DOOR UNSAFE LIGHT COME ON IN FLIGHT THAT RESULTED IN THE ACFT DIVERTING TO ANOTHER AIRPORT. THE DOOR WARNING LIGHT SYS WAS INSPECTED WITH NO FAULTS FOUND AND RETURNED TO SERVICE. THE ACFT COMPLETED THE FLIGHT WITH NO PROBLEMS. THE NEXT SDR GLBA20120127FB-Nut · leakingPILOT REPORTED AT 22,000 MASTER WARNING WITH A RT LOW OIL PRESSURE ANNUNCIATOR, GOT THE LIGHT AND HAD 2300 LBS OF TORQUE DROPPED TO BELOW 2000 LBS, OIL WAS 45 TO 50, PRECAUTIONARY-SHUTDOWN THE RT ENG & DELCARED AN EMERGENCY. MX FOUND A LOOSE B-NUT ON THE RT ESDR 29GA95721012712AEngine · malfunctionedFLIGHT: 4005 TPA/TPA DURING CLIMBOUT LOUD POP CAME FROM LEFT ENGINE FOLLOWED BY SMOKE COMING FROM PILOT AIR VENTS. SECURED AND SHUT DOWN LEFT ENGINE. NO PRIMARY OR SECONDARY INDICATION OF A FIRE. RETURNED TO TPA LANDED WITHOUT INCIDENT. REPLACED LEFT ENGINSDR CA120127009Flap System · malfunctioned(CAN) ON FINAL APPROACH, WITH FLAPS SET TO 17 DEG, THE CREW NOTICED THAT THEY WERE HAVING TO APPLY A SUBSTANTIAL AILERON CORRECTION. WHEN THE FLAPS WERE SELECTED FULL DOWN FOR LANDING, NO MOVEMENT WAS NOTED. THE CREW SUSPECTED A SPLIT FLAP CONDITION AND LANDSDR CA111219001Engine · fod(CAN) THE INITIAL REPORT FROM THE CUSTOMER INDICATED THAT A FOD INCIDENT HAD OCCURRED AND FOREIGN MATERIAL PASSED THROUGH BOTH MODULES RESULTING IN THE DISCOVERED DAMAGE. OVERHAUL SHOP CONFIRMED THE PRESENCE OF FOD ON THE COMPRESSOR ASSY. REVIEW OF THE CT BLSDR CA111216002Insulator · cracked(CAN) WHEN THE HEAT EXCHANGER WAS REMOVED FOR CLEANING, IT WAS NOTICED THAT THE ACM, INSULATOR, HAD A LARGE CRACK. THIS CRACK IS BEHIND THE COOLING FAN, ALSO THE PACKING, PN 69494J152, IN THE CONTAINMENT HOUSING WAS DETERIORATED AND COMING OUT. THE ACM WAS REPSDR CA111213005Balance Weight · damaged(CAN) AN INSPECTION OF THE LOWER CONTROL COLUMN INSTALLATION WAS CARRIED OUT AFTER BEING MADE AWARE OF ANOTHER OPERATOR SUBMITTING A SDR 20111212006 FOR THE ELEVATOR CONTROL JAMMING PRIOR TO TAKEOFF. THE INSPECTION REVEALED THAT THE STABILIZING WEIGHT, 101-52SDR CA111222010Counterweight · damaged(CAN) DURING AN INTERNAL INSPECTION OF THE ELEVATOR BOB-WEIGHTS ON OUR FLEET OF 1900 ACFT IT WAS DISCOVERED THAT DAMAGE WAS PRESENT ON THE BOB-WEIGHT NEAR THE EDGE OF THE WEIGHT WHERE THE STOP BOLT CONTACTS THE WEIGHT.SDR CA111212006Counterweight · damaged(CAN) THE CREW HAD CONDUCTED THE NORMAL CONTROL TRAVEL CHECKS PRIOR TO TAXING TO POSITION. DURING THE TAKEOFF ROLL THE ELEVATOR CONTROLS FELT HEAVY & APPEARED TO BE JAMMED OR STICKING, REQUIRING MORE FORCE THAN USUAL TO ROTATE. THE CREW SUBSEQUENTLY ABORTED SDR GLBA20111207JCable · brokenPILOT REPORTED THAT THE DOOR SNUBBER CABLE IS BROKEN. MX REPLACED THE DOOR CABLE IAW 52-10-00, OPS CHECKED GOOD.SDR GLBA201112052Door · openDURING THE PASSENGER BRIEFING (WITH ENGINES NOT RUNNING), A PASSENGER OPENED UP THE 6C EMERGENCY EXIT DOOR. MX REINSTALLED THE EMERGENCY EXIT DOOR.SDR GLBA201112024Pump · leakingFUEL LEAKING OUT OF MAIN DRAIN LT NACELLE. MX R & R LT LOW PRESSURE FUEL PUMP.SDR CA111201001Engine · malfunctioned(CAN) TWO MIN. AFTER T/O, THE CABIN FILLED WITH SMOKE AND AN EMERGENCY WAS DECLARED. THE CREW RETURNED TO THE DEPARTURE AIRPORT WHERE ON SHORT FINAL AT 100` ALTITUDE, THE LOW OIL PRESSURE WARNING CAME ON ENGINE NR 2. THE A/C LANDED SAFELY AND BOTH ENGINE WERE SDR CA111124002Bearing · failed(CAN) LT GENERATOR FAIL LIGHT CAME ON IN FLIGHT. ACFT CONTINUED TO DESTINATION. MAINTENANCE DISPATCHED TO LOCATION FOR TROUBLESHOOTING/REPAIR. UPON INSPECTION OF STARTER/GENERATOR, IT WAS NOTED THAT THERE WAS DAMAGE TO THE COOLING FAN, AND A LARGE AMOUNT OF SDR CA111130001Turbine Blades · failed(CAN) DURING TAKEOFF THE ACFT HAD AN ENG POWER SECTION PT BLADE FAILURE. ENG WILL BE REMOVED & SENT FOR INVESTIGATION. MFG WILL INVESTIGATE TO ESTABLISH ROOT CAUSE & SUPPLEMENT THE REPORT ONCE THE INFORMATION IS AVAILABLE.SDR 29GA94272112011AEngine · malfunctionedFLIGHT: 4073 CLE/LWB DURING TAKEOFF ROLL HEARD A LOUD BANG COMING FROM THE LEFT ENGINE A LOSS OF POWER AND A HUMMING NOISE AFTER ENGINE SHUTDOWN AND VISUAL INSPECTION SEVERAL BUMPS ARE FOUND ON THE LEFT ENGINE EXHAUST. REPLACED LEFT ENGINE ASSEMBLY.SDR CA111117002Strut · corroded(CAN) DURING MAINTENANCE, A SHOCK STRUT FLUID LEAK WAS NOTED ON THE NOSE GEAR OF A SN UE79. THE LOWER SHOCK ABSORBER TUBE WAS REMOVED TO FACILIATE SEAL REPLACEMENT. DURING THE PROCESS TO REPLACE THE SEAL, SEVERE CORROSION WAS NOTED AT THE LOWER END OF THE UPSDR CA111117010Pump · unserviceable(CAN) LT ENGINE NOT GOING PAST 30 PERCENT NG ON START. THIS WAS AN INTERMITTENT SNAG ON FIRST START OF DAY WOULD BE DIFFICULT TO START THEN WOULD HAVE NO ISSUES. AFTER SOME TROUBLESHOOTING THAT DID NOT FIX THE ISSUE, THE LT ENGINE HIGH PRESSURE FUEL PUMP WAS SDR GLBA20111107GSwitch · inoperativePILOT REPORTED THAT THE AUTOFEATHER IS DISARMING WHEN THE NR 1 POWER LEVER IS REDUCED TO 93 PERCENT. MX REPLACED THE HP SWITCH.SDR CA111113001Engine · malfunctioned(CAN) WHILE ON T/O ROLL, THE ENGINE STARTED TO "RUNAWAY" AND REACHED 128 PERCENT TORQUE AND POSSIBLY OVER 1000 DEGREES TEMPERATURE BEFORE THE T/O WAS ABORTED. POST EVENT INSPECTION FOUND NO ISSUES WITH THE RIGGING. TROUBLESHOOTING IS ON-GOING WITH VERIFICATIOSDR GLBA20111019FFcu · leakingPILOT REPORTED THAT THERE IS A LEAK COMING FROM THE SMALL DRAIN ON THE LT ENGINE. MX REPLACED THE LT HP FUEL PUMP AND FCU, OPS AND LEAK CHECKED GOOD.SDR GLBA201110181Bulb · burned outEMERGENCY LIGHT UNDER GLARESHIELD ON CAPT SIDE INOPERATIVE FOUND DURING PREFLIGHT INSPECTION BY CREW. MX DETERMINED BULB WAS BURNED OUT AND REPLACED THE BULB.SDR 29GA95773101711ATransfer Tube · leakingFLIGHT: 4017 BIM/FLL PILOT REPORTED STRONG FUEL SMELL IN CABIN NOTICED WHEN BOTH ENGINES RUNNING AND LEFT BLEED OPEN. REPLACED FOUR TRANSFER TUBES AND ORINGS ON NUMBER ONE ENGINE FUEL NOZZLES AT SIX O`CLOCK POSITION LEAK CHECK GOOD.SDR CA111019020Cooling Fan · damaged(CAN) DURING RE-INSTALL OF THE HEAT EXCHANGER, AFTER CLEANING, NOTICED THAT THE FAN BLADES OF THE ACM WERE DAMAGED. A FUTHER INVESTIGATION FOUND THAT THE BLADES ALSO DAMAGED THE CASE AND THERE WAS PLAY IN SUPPORT BEARING. REF CMM 21-51-33, FIG ITEM 59.SDR GLBA20111017GPump · leaking"SUP" -MX REPORTED THAT THE LT HP FUEL PUMP WAS LEAKING. MX REPLACED THE FCU, OPS CK GOOD.SDR GLBA20110914001Annunciator · inoperativePILOT REPORTED THAT AUTOFEATHER ANNUNCIATOR IS INOPERATIVE. OPENSDR GLBA20110912GAnnunciator · inoperativePILOT REPORTED THAT THE AUTOFEATHER OFF ANNUNCIATOR DID NOT ILLUMINATE WITH THE PRESS-TO-TEST. MAINTENANCE REPLACED THE AUTOFEATHER ANNUNCIATOR, OPS CHECKED GOOD.SDR GLBA20110912FSolenoid · dirtyPILOT REPORTED THAT THE LEFT PROPELLER WENT INTO GROUND IDLE DURING LANDING FLARE, RESULTING IN A STONG YAW TO THE LEFT. MX CLEANED THE NR 1 LOW PITCH SOLENOID, OPS CK GOOD.SDR GLBA20110907FBulb · inoperativePILOT REPORTED THAT THE INSTRUMENT EMERGENCY LIGHT ON THE CA'S SIDE BURNED OUT. MX REPLACED THE BULB PN: 1864, IAW BMM 33-10-04, OPS CK GOOD.SDR GLBA20110906GBulb · inoperativePILOT REPORTED THAT THE GEAR HANDLE HAS ONE RED LIGHT THAT IS INOPERATIVE. MAINTENANCE REPLACED THE BULB IAW BMM 33-10-05, OPS CHECKED GOOD.SDR GLBA20110902FAutofeather Sys · malfunctionedPILOT REPORTED THAT THE PROP WENT INTO AUTOFEATHER ON FINAL, THEN CAME BACK OUT, FELT LIKE THE RT SIDE. MX TROUBLESHOT THE SYS IAW WITH THE RUNSHEET AND BMM 61-21-00 SEC 1(A), SYS OPS CHECKED GOOD, OK FOR SERVICE.SDR GLBA20110825FGovernor · inoperativePILOT REPORTED THAT WHEN PERFORMING THE FEATHER TEST THE CB POPS. MX REPLACED THE RT OVERSPEED GOV AND PCB A123 IAW 61-20-01 , MI 24-01, AND TC 1900-7100, OPS CHECKED GOOD.SDR GLBA20110824FPower Lever · splitPILOT REPORTED THAT WITH THE TORQUE SET AT 1000 LBS, RT PROP CYCLED IN & OUT OF FEATHER 3 TIMES WITH THE AFX ARMED. MX FOUND SPLIT IN THE POWER LEVERS, RIGGED LT DEADBAND IAW CH 7 AND OPS CK GOOD REF TC1900-RUN WORKSHEET.SDR GLBA20110823GFuel Control · leakingPILOT REPORTED THAT THE RT ENGINE IS LEAKING FUEL FWD OF THE WHEEL WELL, DRIPPING STOPS ATFTER SHUTDOWN. MX REPLACED THE RT FCU IAW TC 1900-7320.00 AND REPLACED HP PUMP IAW MM 73-10-02 SEC 6, REPLACED STARTER GEN, RIG CHECKS, RUN AND LEAK CHECKED GOOD.SDR GLBA20110822JPump · leakingPILOT REPORTED THAT THERE IS A FUEL LEAK FROM THE HIGH PRESSURE FUEL PUMP DRAIN ON THE LEFT ENGINE. MX REPLACED THE LEFT HIGH PRESSURE FUEL PUMP IAW 73-10-02 AND THE FCU IAW TC. 1900-7320.00, OK FOR SERVICE.SDR CA110817011Actuator · failed(CAN) DURING APPROACH, THE LANDING GEAR WAS SELECTED DOWN. THE NOSE AND LT GEAR CAME DOWN NORMALLY, AND THE PUMP CONTINUED TO RUN WHILE THE RT GEAR SLOWLY DESCENDED. THE RT GEAR EVENTUALLY LOCKED DOWN, AND A NORMAL LANDING WAS MADE. THE ACFT WAS INSPECTED,SDR CA110812006Engine · making metal(CAN) ENGINEERING INVESTIGATION REPORT EIR PT6A 2011-080 - REV 2. THIS ENGINE WAS SENT TO VECTOR AFTER THE OPERATOR REPORTED METAL IN OIL. UPON REVIEW FOLLOWING A LOW OIL PRESSURE INDICATION DURING CLIMB. THIS WAS ENCOUNTERED DURING THE FIRST FLIGHT FOLLOWSDR CA110816008Housing · cracked(CAN) THE CHIP DETECTOR HOUSING ATTACHMENT BOLTS WERE FOUND TO BE CRACKED ON THE NR 1 ENGINE, RESULTING IN ONLY THE O-RING AND LOCKWIRE HOLDING THE CHIP DETECTOR HOUSING IN PLACE PREVENTING AN IN-FLIGHT SHUTDOWN. THIS HAS OCCURRED PREVIOUSLY 150 HOURS PRIOR, ASDR CA110905004Engine · power loss(CAN) UNCOMMANDED AUTOFEATHER DURING TAKEOFF ROLL, WAS REPORTED BY THE FLIGHT CREW. ENGINE WAS NEVER SECURED THEREFORE REACHED MAXIMUM TORQUE VALUE FOR ABOUT 6 MINUTES. AN UNEVENTFUL LANDING WAS CONDUCTED WITH 1 ENGINE IN FEATHER CONDITION. POST LANDING INSPESDR GLBA20110727HPcb · inoperativePILOT REPORTED THAT THE LT AUTOFEATHER SYS DID NOT ARM ON TAKEOFF ROLL. MX REPLACED PCB A123 IAW AIM MI 24-01.SDR GLBA20110727JPcb · inoperativePILOT REPORTED THAT ON DECENT THE RT AUTOFEATHER DID NOT ARM. MX REPLACED PCB A123 PN: 129-304091-9 SN: 735599 IAW AIM MI 24-01, OPS CK GOOD.SDR GLBA20110725FSolenoid · dirtyPILOT REPORTED THAT THE RT ENGINE WENT INTO AUTOFEATHER DURING FLARE. MAINTENANCE CLEANED THE LOW PITCH STOP SOLENOID, PERFORMED AUTOFEATHER OPS CHECKED IAW 61-21-00, SYS OPS CHECKED GOOD.SDR GLBA20110721FPropeller · malfunctionedPILOT REPORTED THAT DURING APPROACH THE LT PROP WAS CYCLING IN AND OUT OF FEATHER WITH ABOUT 500LBS OF TORQUE. R & R LT & RT LOW PRESSURE AUTO FEATHER SWITCHES & RIGGED LT & RT ENG TORQUE IAW CH 7, SECTION 7.5 & BMM 61-21-01, OPS CHECKED GOOD.SDR GLBA20110719FPump · leakingPILOT REPORTED THAT FUEL WAS LEAKING FROM THE NR2 ENGINE GANG DRAIN. MX REPLACED THE NR2 ENGINE DRIVEN FUEL PUMP IAW BMM 73-10-00.SDR GLBA20110715GSwitch · stuck"SUP" - SIG EVENT - PILOT REPORTED THAT THE RT PROP FEATHERED WHEN APPLYING TO POWER. MX FOUND RT AND LT TEST SWITCHES STUCK, R & R BOTH TEST SWITCHES, IAW AIM 12.10.0, OPS CK GOOD.SDR GLBA20110715HPcb · inoperativeDURING THE OVERSPEED TEST ON THE RT ENGINE THE AUTOFEATHER DISABLE ANNUNCIATOR ILLUMINATED. MX REPLACED THE AFX PCB IAW MI 24-01, OPS CHECKED GOOD.SDR GLBA20110714FPropeller · malfunctionedTHE PILOT REPORTED THAT ON APPROACH, AT 500' AGL WITH BOTH TORQUES AROUND 750LBS THE RT ENGINE CYCLED INTO AND OUT OF FEATHER TWICE, ADDED POWER TO 1500LBS AND IT STOPPED. MX FOUND LT ENGINE HIGH & LOW TORQUES OUT OF RIG, RERIGGED POWER LEVERS IAW AIM 7.2.4 &
Back to Pratt & Whitney Canada PT6A-67D