SDR 29GA91279070111ATransducer · failedDURING CLIMB, NOTICED THE RT ENGINE OIL PRESSURE WAS BELOW 90 PSI, ALL OTHER ENGINE INDICATIONS WERE NORMAL. ADVISED ATC OF THE DIVERSION AND DECLARED AN EMERGENCY. LANDED WITHOUT FURTHER INCIDENT. R & R RT ENGINE OIL PRESSURE TRANSDUCER.SDR CA110711016Fcu · inoperativeRIGHT ENGINE N1 AND TORQUE ACCELERATED UNCONTROLLED WHEN POWER WAS APPLIED ON TAKEOFF.SDR CA110704001Bearing · failedEIR PT6A 2011-075, IN CRUISE AT FL 190, A LARGE BANG FOR THE L/T ENGINE FOLLOWED BY A RAPID RISE IT ITT WAS EXPERIENCED. AS THE ITT WAS RISING TO APPROX 860, THE CREW REDUCED TORQUE TO MAINTAIN ITT WITHIN LIMITS. THE TORQUE WAS REDUCED TO 2000 FT/LBS WHERE SDR GLBA20110627GSkin · crackedMAJOR REPAIR - DURING A SCHEDULED ROUTINE INSP, MX FOUND A CRACK IN THE INNER SKIN OF THE EMERGENCY EXIT AT 6A, VERT LENGTH 3.25"M ABD HORZ 3". MX REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 11-1900-52-007. MATERIALS UTILIZESDR CA110810009Connector · faultyELT BEGAN SOUNDING ON THE GROUND FOR NO APPARENT REASON. FAULTY "D" SUB CONNECTOR AT REMOTE SWITCH OF ELT SYS CAUSES ELT TO TRANSMIT INTERMITTENTLY. REPLACED CONNECTOR WITH MIL CRIMP TYPE. NO FURTHER FAILURES REPORTED.SDR CA110614016Line · damagedCREW HAD RT BL FAIL ANNUNCIATOR ILLUMINATE IN FLIGHT. WHEN COMPLETING THE REQUIRED CHECK LIST TURNING THE BLEED OFF THERE WAS NO CORRESPONDING DECREASE IN ENGINE ITT. MX FOUND THAT THE FLARE ON PN 129-550084-X WAS CRACKED.SDR CA110614004Governor · malfunctionedABORTED TAKEOFF DURING TAKEOFF ROLL, AS THE PILOT ADVANCED THE POWER LEVER, THE ENGINE ACCELERATED AND WITH A TARGET PROPELLER SPEED OF 1700 RPM SET, IT WENT TO 1803 RPM AND THE SPEED COULD NOT BE CONTROLLED. THE T/O WAS ABORTED. TROUBLESHOOTING IS FOCUSING ONSDR CA110614007Engine · overtemp(CAN) LT ENGINE ITT WENT OVER 860 DEGREES IN FLIGHT AND MADE ABNORMAL SOUNDS. ENGINE SHUTDOWN CARRIED OUT. ENGINE HAS BEEN RETURNED TO O/H SHOP FOR TEARDOWN.SDR CA110610008Precooler · crackedTHE PILOT REPORTED THE ENGINE HAD MARGINAL PERFORMANCE DURING HIGH AMBIENT TEMP CONDITIONS WITH ANTI-ICE ON THE ENGINE WAS TEMPERATURE LIMITED. ALL ENGINE AIR SYS WERE INSPECTED AND MX DISCOVERED THE RT ENGINE PRECOOLER HAD CRACKED ON THE INLET SIDE WELD JOINSDR GLBA20110603GAutofeather Sys · malfunctionedPILOT REPORTED THAT THE LT ENGINE AUTOFEATHERED ON FINAL, EACH ENGINE SET TO 300LBS, ADVACED TO 1000 LBS LT ENGINE AUTOFEATHERED UNTIL POWER WAS ADVANCED. MX RIGGED BOTH ENGINES IAW WITH THE MM, OPS CK GOOD.SDR GLBA201106031Valve · malfunctionedLT ENG AUTO FEATHERED ON FINAL, EACH ENGINE SET TO 300 LBS, ADVANCED TO 1000 LBS, LT ENG AUTO FX UNTIL POWER ADVANCED ABOVE 1200 LBS. MAINTENANCE ADJUSTED RT ENGINE BETA VALVE AND LOW PITCH SOLONOID REF AIM72-50 AND T.C. 1900-ENGINERUN SHEET.SDR GUUA95753060111ADoor Frame · crackedDURING SCHDULED ROUTINE STRUCTURAL INSP DISCOVERED CARGO DOOR FRAME CRACKED APPROX 2.0 INCHES AT TOP FORWARD AREA OF FRAME BETWEEN FS 456 AND FS 468.25. STOP DRILLED ENDS OF CRACK AND INSTALLED 10.0 INCH REPAIR DOUBLER.SDR CA110518001Line · crackedENGINEERING INVESTIGATION REPORT EIR PT6A 2011-053 UPON ARRIVAL THE ENGINE WAS DISASSEMBLED TO REMOVE THE GG CASE. ONCE REMOVED, IT WAS READILY APPARENT THAT THE P3 TUBE WAS CRACKED JUST FORWARD OF THE POINT WHERE IT PASSES THROUGH THE PRESSURE VESSEL FORWARD SDR GLBA201105131Unknown · odorTHE PILOT REPORTED THAT DURING DESCENT THEY SMELLED FUEL. MX CLEANED THE EPA CANNISTER AND CHECKED FUEL VALUES ON BOTH ENGINES, PERFORMED FCD 1900-08-30-01 STEPS 3&4, NO FURTHER DEFECTS NOTED.SDR CA110516013Control System · out of rigPOWER ROLL BACK/IFSD DURING CLIMB, THE LT ENGINE NG ROLLED BACK TO 73 PERCENT WITH ASSOCIATED DECREASE IN FUEL FLOW. POWER LEVER ADVANCE HAD NO EFFECT AND THE ENGINE WAS SHUTDOWN AS A PRECAUTIONARY MEASURE. THE ACFT RETURNED TO THE POINT OF DEPARTURE WHERE ANSDR GUUA94057050211CStringer · corrodedDURING SCHEDULED X-RAY INSP DISCOVERED RT WING FWD LOWER BONDED J STRINGER HAS CORROSION BETWEEN WS 114.25 AND 124.25 . REMOVED CORROSION AND INSTALLED REPAIR STRAP.SDR CA110428002Turbine Wheel · damaged(CAN) DISCOVERED THAT THE PROPELLER SHAFT WOULD ROTATE IN A CLOCKWISE DIRECTION PILOT`S VIEW, FREELY WITH A "CLUNKING" NOISE BUT WOULD BIND WHEN ATTEMPTING TO ROTATE THE PROPELLER SHAFT IN THE OPPOSITE DIRECTION DURING THE RECEIVING INSPECTION. 1 OF THE INTESDR GLBA20110428FStructure · damagedMAJOR REPAIR - MX REPORT THAT DURING REFUELING, THE FUEL TRUCK STRUCK THE RT STABILON, THE RT STABILON WAS REPLACED ON 192GL. MX REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 11-1900-55-007. MATERIALS UTILIZED ARE INCLUDED IN THSDR CA110426001Blade · failed(CAN) ENGINEERING INVESTIGATION REPORT EIR PT6A 2011-047. THIS ENGINE WAS SENT TO FOR INVESTIGATION OF 2ND STAGE PT BLADE FAILURE REPORTED BY THE CUSTOMER. OPERATOR REPORTED THAT AFTER SETTING THE TAKEOFF POWER, THERE WAS A LOUD BANG ACCOMPANIED BY A SUDDEN SDR CA110427009Blades · fractured(CAN) POWER LOSS/IFSD UPON APPLYING POWER FOR T/O, A LOUD NOISE WAS HEARD. THE ENGINE WAS SHUTDOWN AND THE ACFT TAXIED BACK TO THE GATE. POST EVENT INSPECTION REVEALED THAT THE FRACTURE OF THE 2ND STAGE POWER TURBINE BLADES.SDR 5APR577Y59Proximity Sensor · faultyPILOT REPORTED FLAP CAWS AFTER SELECTING FROM 0 TO 15 DEGREES. 1 RESET ON GROUND PERFORMED ON PREVIOUS LEG. RESOLUTION TO CORRECT THIS SITUATION IS AS FOLLOWS. THE LT FLAP ROTATION TRANSMITTER PN 973.30.33.112 WAS AT FAULT AND WAS REPLACED, IAW AMM 12-A-27-5SDR CA110415001Skin · delaminated(CAN) LT UPPER FWD NACELLE COVER PANEL STARTED DELAMINATING AND TEARING BACK WHILE IN FLIGHT. PASSENGERS NOTIFIED THE FLIGHT CREW AND THE ACFT LANDED WITHOUT INCIDENT. ANOTHER PANEL WAS INSTALLED AND ACFT RETURNED TO SERVICE.SDR CA110427007Blades · fractured(CAN) ABORTED T/O. SECOND STAGE POWER TURBINE BLADES WERE FOUND FRACTURED. THE ENGINE IS BEING REPLACED.SDR GUUA94955040511BStringer · crackedDURING SCHEDULED ROUTINE INSP, DISCOVERED VERTICAL STAB RT SIDE APPEARS TO HAVE CRACKS AT EACH OF THE 3 CHORD STRINGERS AT CSS 54.026. STOP DRILLED CRACKS AND INSTALLED REPAIR STRAPS THREE EACH.SDR CA110413001Gas Generator · seized(CAN) UNCOMMANDED SHUTDOWN DURING FLIGHT TEST FOR CERTIFICATE OF APPROVAL PURPOSES, THE ENGINE WAS SHUTDOWN AND RELIT IAW OPERATING HANDBOOK. 2 MIN AFTER RE-LIGHT, THE ENGINE SHUTDOWN UNCOMMANDED AND COULD NOT BE RE-STARTED. AN UNEVENTFUL SINGLE ENGINE LANSDR GUUA94531031511AEngine · malfunctionedPILOT REPORTED NR 1 ENG N1 AND TORQUE DECREASED CONTINUOUSLY IN FLIGHT WHEN TORQUE REACHED 0 ENGINE SECURED. DIVERTED, LANDED WITHOUT INCIDENT. (OPEN)SDR GUUA94531031411AFuel Control · failedPILOT REPORTED INFLIGHT THE LEFT LOW FUEL PRESSURE ANNUNCIATOR ILLUMINATED, DECLARED AN EMERGENCY DIVERTED TO JAX SECURED THE ENGINE LANDED WITHOUT INCIDENT. REPLACED LEFT ENGINE FUEL CONTROL AND HIGH PRESSURE FUEL PUMP GROUND PERFORMANCE CHECK WITH POWER ASDR CA110303003Hose · leaking(CAN) ENGINE FUEL PUMP TO FIREWALL HOSE ASSY ON LT ENGINE FOUND TO BE LEAKING AND IT`S FIRE SLEEVE SATURATED IN FUEL. HOSE WAS REMOVED FROM ACFT. THE FIRE SLEEVE WAS REMOVED REVEALING A HOLE IN THE HOSE.SDR GUUA94161022511AAnnunciator · no indicationPILOT REPORTED WITH N1 AT 95 PERCENT "AFX DISABLE" ANNUNCIATOR WAS ILLUMINATED AND LT AFX WAS NOT ILLUMINATED. RERACKED ANNUNCIATOR FAULT DETECTION PCB AUTOFEATHER TEST OPS CHECK GOOD.SDR GUUA93353022211AAngle · crackedDURING SCHEDULED ROUTINE INSP, DISCOVERED CRACK FWD ANGLE AT FS 150 TOP STRUT ASSY SUPPORT BRACKET NUTPLATE. REMOVED DAMAGED ANGLE AND INSTALLED FILLER ANGLE AND REPAIR SPLICES.SDR GUUA93353022211BAngle · crackedDURING SCHEDULED ROUTINE INSP, DISCOVERED LT WING FUSELAGE CLOSING ANGLE CRACKED 1.0 INCH AT FS 288.0. STOP DRILLED CRACK AND INSTALLED REPAIR ANGLE.SDR GUUA95652021911BDoor · obstructedDURING SCHEDULED ROUTINE INSP DISCOVERED RT AFT EMERGENCY EXIT DIFFICULT TO OPEN. ADJUSTED UPHOLSTERY ON RT AFT EMERGENCY EXIT OPS, CHECK GOOD.SDR GLBA20110215FStructure · crackedDURING A SCHEDULED ROUNTINE INSP MX, FOUND THE RT STABILON HAS A .5" HOLE 9" FROM T/E CORNER, CRACK RADIATED FROM INBD EDGE OF HOLE 1" IN LENGTH. MAINTENANCE COULD NOT REPAIR RT STABILON, REPLACED RT STABILON IAW BMM 55-10-01-201, NO RII REQUIRED FOR INSTALLASDR CA110214020Relay · failedLANDING GEAR WOULD NOT EXTEND WHEN THE GEAR SELECTOR WAS MOVED TO THE DOWN POSITION. GEAR WAS EXTENDED USING MANUAL HAND PUMP WITH NO OTHER PROBLEMS. UPON INSP IT WAS DISCOVERED THERE WAS MOISTURE IN THE MLG RELAY CAUSING IT TO FREEZE IN FLIGHT. THIS WAS PROSDR GLBA20110204GStringer · crackedMAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSP, MX FOUND A CRACK IN THE STRINGER 9AR AT FS 451.0, .4" IN LENGTH. MAINTENANCE REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS I.A.W. EO 11-1900-53-007. MATERIALS UTILIZED ARE INCLUDED IN THSDR GLBA20110204FFrame · crackedMAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSP, MX FOUND 2 CRACKS AT THE FRAME FS 456.0 RADIATING FROM STRINGER 9AR CUTOUT, UPPER CRACK .6" IN LENGTH, LOWER CRACK .35" IN LENGTH. MAINTENANCE REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIOSDR GLBA20110204HSkin · debondedMAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSP, MX FOUND THE AIRSTAIR DOOR LOWER INNER SKIN DEBONDED, AREA 16" X 6" FROM LOWER EDGE INWARD TO STOP HINGE. MAINTENANCE REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS I.A.W. EO 11-1900-52-0SDR GLBA20110203FFrame · crackedMAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSP, MX FOUND A CRACK IN THE FRAME AT FS 280.73 AT STRINGER 5R CUTOUT, .2" IN LENGTH. MAINTENANC PERFORMED ANOTHER INSPECTION ON THE AREA AND FOUND THE THE CRACK WAS A PEN MARK FROM ORIGINAL MANUFACTURE.SDR GUUA94352010611AHandle · stiffDURING SCHEDULED ROUTINE INSP, DISCOVERED RT AFT EMERGENCY EXIT DOOR INNER HANDLE STIFF TO OPERATE. LUBRICATED RT EMERGENCY EXIT DOOR INNER HANDLE. OPS CHECK NORMAL.SDR GUUA95257010311ASkin · corrodedDURING SCHEDULED ROUTINE INSP, DISCOVERED RT WING UPPER SKIN T/E CORROSION AND DEBOND BETWEEN WING STA 138.00 AND 160.25. REMOVED DAMAGED SKIN AND INSTALLED AN EXTERNAL DOUBLER REPAIR.SDR GUUA95657010311ASkin · damagedDURING SCHEDULE ROUTINE INSP, DISCOVERED A HOLE APPROX 0.032 IN IN DIAMETER ON THE RT WING UPPER SKIN T/E. INSTALLED CR3213-4-1 RIVET IN THE HOLE.SDR GUUA95253010311ASkin · chafedDURING SCHEDULED ROUTINE INSP, DISCOVERED SKIN CHAFED AT FUSELAGE STA 258 AND BUTT LINE 29.5 ON THE LT SIDE OF THE ACFT. REPAIRED SKIN CHAFE BY INSTALLING COVER PATCH.SDR GUUA95532123110AAnnunciator · inoperativePILOT REPORTED LANDING GEAR "R" ANNUNCIATOR INOPERATIVE. RESET "R" ANNUNCIATOR IN SOCKET. OPS CHECK NORMAL.SDR GLBA20101229FAngle · crackedMX FOUND A 1.5" CRACK IN THE BEND RADIUS AT THE RT HEAVY ANGLE AT FS 288. MX REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSP EO 10-1900-53-064. MATERIALS UTILIZED ARE INCLUDED IN THE EO.SDR GUUA94652122710AHandle · bindingDURING SCHEDULED ROUTINE INSP, DISCOVERED LT EMERGENCY EXIT HANDLE HARD TO OPEN. LUBRICATED LT EMERGENCY EXIT HANDLE.SDR GUUA93332122510ALamp · looseNOSE GEAR INDICATION LOOSE. RESECURED NOSE GEAR INDICATION LAMP.SDR GUUA93332122510BAnnunciator · looseNOSE GEAR INDICATION LOOSE. RESECURED NOSE GEAR ANNUNICATOR.SDR GUUA93832122210ADiode · inoperativeDURING APPROACH, LANDING GEAR HANDLE LIGHTS INOPERATIVE. REPLACED DIODE AND SOCKET 14 ON CONNECTOR P200. OPS CHECK SATISFACTORY.SDR GUUA95552121910ALatch · out of adjustPILOT REPORTS AIRSTAIR DOOR DIFFICULT TO CLOSE. RE-INDEXED CAM LATCHES OPS CHECK GOOD.SDR GUUA94071121710ABracket · crackedDURING MAGNETIC PARTICLE INSP, DISCOVERED ENGINE TRUSS COWL BRACKET WELD AREAS CRACKED. PERFORMED WELD REPAIR TO ENGINE TRUSS COWL BRACKET WELD AREA CRACKS. FOUND DURING MAGNETIC PARTICLE INSP.
Back to Pratt & Whitney Canada PT6A-67D