Pratt & Whitney Canada PW120A
Service difficulty reports · 2,399
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW120A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW120A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA111214015Engine · power loss(CAN) DURING CRUISE BOTH ENGINES HAD A 10-15 PERCENT ROLL BACK FOR 2-3 SEC. BEFORE RECOVERING SET POWER ON 2 SEPARATE OCCASIONS. THE FLIGHT LANDED UNEVENTFULLY. GROUND RUNS COULD NOT REPLICATE THE PROBLEM AND TROUBLESHOOTING IS ON-GOING.SDR CA111216003Engine · unknown(CAN) DURING CRUISE AT TWO OCCASIONS BOTH ENGINES TORQUE MOMENTARILY ROLLED BACK OF 10-15 PERCENT. THE ACFT LANDED TO DESTINATION WITHOUT FURTHER INCIDENT AND THE ACFT WAS REMOVED FROM SERVICE. MAINTENANCE WAS UNABLE TO REPRODUCE THE POWER LOSS. ELECTRICAL SDR CA111208011Gust Lock · defective(CAN) AFTER REMOVING THE CENTER WING GUST LOCK LEVER, HOUSING, DURING RECTIFICATION OF AN UNRELATED DEFECT, IT WAS NOTED THAT THERE WAS CORROSION AROUND THE PIVOT BORE BUSHINGS. UPON FURTHER INVESTIGATION, MORE CORROSION WAS DISCOVERED BETWEEN THE BUSHINGS IN SDR CA111206014Actuator · worn(CAN) DURING HEAVY MAINTENACE, INSPECTION OF THE LT INBD FLAP ACTUATOR, NR 1 POSITION, REVEALED EXCESSIVE PLAY IN THE INPUT SHAFT. THE ACTUATOR HAS BEEN SENT TO THE VENDOR FOR INSPECTION/REPAIR. A SERVICEABLE ACTUATOR WAS INSTALLED IAW THE AMM. THIS SDR WILLSDR CA111214005Engine · power loss(CAN) DURING REVENUE FLIGHT, PILOT REPORTED POWER ROLL BACK. ENGINE REMAINED IN OPERATION, HOWEVER, AS SOME ENGINE PARAMETERS NEVER RECOVERED, PILOT ELECTED TO PERFORM AN AIR TURNBACK TO AIRPORT.SDR CA111208013Switch · damaged(CAN) AFTER LANDING FLIGHT/TAXI SPOILER SWITCH IN TAXI MODE FAILED AFTER LANDING DURING TAXI TO THE GATE. FLIGHT-TAXI SWITCH WOULD NOT REMAIN LATCHED. REPLACED SPOILER FLT TAXI SWITCH AND RETURNED ACFT TO SERVICE.SDR CA111205006Solenoid Valve · failed(CAN) WHEN THE LANDING GEAR WAS SELECTED UP AFTER DEPARTURE, ALL OF THE NR 2 HYD SYSTEM FLUID WAS LOST AND THE LANDING GEAR DID NOT GO UP BUT REMAINED DOWN AND LOCKED. THE ACFT LANDED SAFELY. MAINTENANCE INVESTIGATION REVEALED THAT THE RT LANDING GEAR DOOR SSDR CA111209001Connector · shorted(CAN) DURING CLIMB THE LT ELEVATOR HORN HEAT CAUTION LIGHT CAME ON. THE ACFT WAS ALREADY OPERATING ON THE SECONDARY HEAT ELEMENT AND THUS RETURNED TO THE MTC BASE IT DEPARTED FROM. DURING MTC T/S IT WAS NOTICED THAT ALL OF THE NAVIGATION LIGHTS WERE U/S ALSO ASDR CA111129009Panel · malfunctioned(CAN) DURING THE APPROACH, THE LT ADVISORY DISPLAY PANEL ID802, STARTED TO FLASH & THE FLIGHT CREW NOTICED AN ELEC SMELL IN THE COCKPIT. THE APPROACH WAS CARRIED ON & THE ACFT LANDED WITHOUT FURTHER INCIDENT. AT THE TIME OF THE INCIDENT, THE ACFT WAS OPERATISDR CA111130008Indicator · malfunctioned(CAN) MAINTENANCE NOTICED DISPLAY ON VSI/TRA TCAS INDICATOR VERY DIM AND FLICKERING. VSI REPLACED WITH SERVICEABLE UNIT. ACFT RETURNED TO SERVICE.SDR CA111122004Bearing Race · broken(CAN) DURING REPLACEMENT OF THE ACFT LT PROPELLER ACTUATOR, THE ENGINEER NOTICED THAT THE NR 1 BLADE, OUTER RACE LOCATED INSIDE THE PROPELLER HUB WAS BROKEN. VISUAL INSPECTION OF THE NR 1 BLADE OUTER RACE, PICTURES 1 & 2, REVEALED PLATING MISSING ON THE LOWERSDR CA111124001Pressure Switch · failed(CAN) DURING TAXI TO THE GATE THE NR 2 ENGINE FUEL FILTER BYPASS LIGHT ILLUMINATED. THE NR 2 DIFFERENTIAL PRESSURE SWITCH WAS REPLACED ALONG WITH THE NR 2 HP FUEL FILTER, PN 7589141. GROUND RUNS WERE CARRIED OUT AND THE ACFT WAS RETURNED TO SERVICE.SDR CA111123005Actuator · failed(CAN) EN-ROUTE, FLIGHT CREW FELT LIKE IF THE FLAPS WERE EXTENDED. THE SPEED WAS REDUCED, THE FLAP SELECTOR CYCLED FROM 0 TO 5 DEGREES & BACK TO 0 DEGREES. HOWEVER THERE WAS NO FLAP MOVEMENT DETECTED. FLAPS POSITION WERE VISUALLY CONFIRMED & FOUND EXTENDED. SDR CA111116002Oil System · low(CAN) JUST AFTER TAKEOFF THE NR 1 ENG OIL PRESS WARNING LIGHT ILLUMINATED & THE OIL PRESS GAUGE WAS FLUCTUATING BELOW 40 PSI. AN IN-FLIGHT ENG SHUTDOWN WAS CARRIED OUT & EMER DECLARED. THE ACFT SAFELY RETURNED TO THE DEPARTURE AIRPORT. INVESTIGATION FOUND TSDR CA111114006Pcu · leaking(CAN) ON CLIMB OUT THE ENG OIL PRESS WARNING LIGHT ILLUMINATED & THE CREW ELECTED TO RETURN. THE ACFT LANDED WITHOUT FURTHER INCIDENT. THE CREW PERFORMED A VISUAL INSPECTION OF THE ENG & FOUND EVIDENCE OF OIL LEAK. INSPECTED THE ENG, REPLACED THE PROPELLER SDR CA111115014Bracket · cracked(CAN) ON A 2C-CHECK WHILE PERFORMING A VISUAL INSPECTION OF RT WING AREA, BYW45.00 TO WING BOX OTBD END, IAW CARD 04-55-31I, RT WING OTBD SPOILER ACTUATOR BRACKET FOUND CRACKED, DWG 85711503.SDR CA111109002Access Panel · departed(CAN) ENGINE TOP PANEL 412CT WAS FOUND NEAR A RUNWAY THRESHOLD BY LOCAL AIRPORT AUTHORITY. IT WAS QUICKLY TRACED BACK TO THE AIRCRAFT. THE PANEL WAS INSPECTED AND FOUND SERVICEABLE. IT WAS SHIPPED TO THE STATION WHERE THE AIRCRAFT WAS SITTING AND INSTALLED. THSDR CA111102002Filter · inoperative(CAN) ENROUTE, CREW RECEIVED NR 2 FUEL FILTER BYPASS CAUTION LIGHT. FLIGHT RETURNED TO DEPARTURE FOR REPAIR. FUEL FILTER AND BYPASS SWITCH REPLACED, GROUND RUNS COMPLETED, CHECKED SERV. SWITCH, PN: 59055-88. FILTER, PN: 7589141.SDR CA111028006Electrical Box · inoperative(CAN) PILOT REPORTED WHILE DOING PRE-FLIGHT CHECKS ALL AVIONICS UNSERVICEABLE, EXCEPT FOR UNS GPS, AND INTERPHONE. NO RADIOS. FOUND REU TO BE AT FAULT AND ODOR COMING FROM IT. REPLACED REU, SYSTEMS CHECKED SERVICEABLE AND ACFT RETURNED TO SERVICE. REU TO BSDR CA111028005Sensor · faulty(CAN) AFTER TAKEOFF WOW CAUTION LIGHT ILLUMINATED FOR APPROX 10 SECONDS, THEN EXTINGUISHED. FLIGHT CONTINUED WITH NO FURTHER FAULTS. TESTED SYS AND FOUND NR 2(RT) NLG WOW SENSOR AT FAULT. REPLACED NLG WOW 2 SENSOR ASSY. INTERMITTENT OPEN ON FAULTY WOW SENSOSDR CA111024004Generator · burned(CAN) THE ACFT WAS STRUCK BY LIGHTNING INBOUND. AT THE TIME OF THE STRIKE THE NR 1 DC GENERATOR WENT OFF LINE BUT WAS RESET SUCCESSFULLY. DURING THE LIGHTNING STRIKE INSP DAMAGE WAS FOUND AT THE FOLLOWING LOCATIONS ON THE ACFT: THE LT AILERON TIP HAD A HOLE SDR CA111025004Line · punctured(CAN) HYD LEAK FOUND ON OTBD NR 2 NACELLE. FOUND TO BE COMING FROM A PIN HOLE IN THE EMERGENCY BRAKE PRESSURE HYD LINE. LINE REPLACED AND SYSTEM TESTED. ACFT RETURNED TO SERVICE.SDR CA111021007Wire · shorted(CAN) DURING TAXI OUT, THE CREW NOTICED A STRONG BURNING ODOR IN THE CABIN AND COCKPIT. THE CREW ELECTED TO STOP IN THE CENTRAL DEICE FACILITY AND EVACUATE THE ACFT. DURING MX T/S THE FOLLOWING ADDITIONAL DEFECTS WERE NOTED: THE NR 2 CARGO SMOKE DETECTOR FAISDR CA111019016Wire · chafed(CAN) THE NR 1 ENGINE OIL PRESSURE WARNING LIGHT CAME ON DURING ROTATION AND CONTINUED TO FLICKER DURING THE INITIAL CLIMB. THE OIL PRESSURE ON THE GAUGE WAS STEADY AND NORMAL. ONCE THE ACFT HAD CLIMBED TO A SAFE ALTITUDE THE ENGINE WAS SHUTDOWN IAW THE QRH SDR CA111018006Acm · inoperative(CAN) AFTER ENGINE START, BOTH BLEEDS WERE SELECTED ON AND THE CABIN AND FLIGHT DECK FILLED WITH A SMOKE HAZE. ENGINES WERE SHUTDOWN AND A RAPID DEPLANEMENT WAS CARRIED OUT. AFTER MX T/S WAS CARRIED OUT THE AIR CYCLE MACHINE AND THE HEAT EXCHANGER WERE REPLASDR CA111011010Acm · seized(CAN) AFTER PUSHBACK THE CREW NOTED A HAZE IN THE CABIN AND A BURNING ODOR. A RAPID DEPLANEMENT WAS CARRIED OUT ON THE RAMP. MX FOUND THE ACM SEIZED. THE ACM WAS REPLACED.SDR CA111012004Bearing Race · damaged(CAN) DURING THE ACCOMPLISHMENT OF TASK DH1-61-10-00-RR-801-0, WHEN THE RT PROP HUB WAS REMOVED, IT WAS FOUND THAT THE NR 2 BLADE BEARING RACE INSIDE THE HUB WAS DAMAGED AND CRACKED. THE BEARING, BEARING RETAINER AND BLADE RACE WERE INSPECTED AND NO DAMAGE WASDR CA111024005Fuel Filter · malfunctioned(CAN) HAD SEVERAL OCCURENCES OF FUEL FILTER BY PASS LIGHT COMING ON IN FLIGHT ON OUR -8 ACFT. WE WERE USING PMA, PN 5905587, HP FUEL FILTER, HAVE NOW STOPPED USING THE FILTER AND ARE USING FILTER, PN 3070542-01. HAD NO OCCURENCES ON AN ACFT WITH THE OEM FILSDR CA111004003Actuator · cracked(CAN) THE ACFT LOST ALL OF THEIR NR 1 HYD SYS FLUID IN THE CLIMB, THEY RETURNED TO THE DEPARTURE AIRPORT. MX INVESTIGATION FOUND THAT THE HOUSING OF THE RT INBD ROLL SPOILER ACTUATOR WAS FRACTURED AND WAS THE CAUSE OF THE LOSS OF FLUID. THE ROLL SPOILER ACTUASDR CA110927005Actuator · inoperative(CAN) REF: DEFECT-1013434, LT OTBD ROLL SPOILER WAS NOT MOVING ON THE PFCS AND CONFIRM VISUALLY NOT TO BE MOVING. LP 624597, DURING PRE FLIGHT CHECK, THE LT OTBD SPOILER WAS NOTED AS NOT MOVING ON PFCS AND VISUALLY CONFIRMED. ALL OTHER FLT CONTROLS NORMAL. HSDR CA110921004Line · leaking(CAN) HYD LEAK FOUND COMING FROM NLG AREA ON WALK AROUND. LEAK FOUND TO BE COMING FROM UP SELECTION TO NLG OVERCENTER ACTUATOR HYD LINE LEAKING EXTERNALLY. HYD LINE REPLACED AND ACFT RETURNED TO SERVICE.SDR CA110915007Blade · debonded(CAN) PROPELLER BLADE HEATER ELEMENT BECOMING DISBONDED FROM BLADE AND BUBBLING.SDR CA110915003Union · cracked(CAN) FITTING AN815-10D FOUND COMPLETELY BROKEN INTO 2 PIECES. NO VISUAL EVIDENCE OF LONG TIME CRACK OR CORROSION.SDR CA110912003Manifold · failed(CAN) MTC CONTROL ADVISED DISPATCH THAT 815 HAD LOST NR 1 HYDRAULIC SYSTEM (LOSS OF FLAPS AND BRAKES). CREW DECLARED AN EMERGENCY WITH ATC AND ARFF WAS MEETING FLIGHT ON TOUCHDOWN. TOW CREW ARRANGED TO TOW ACFT TO GATE. FLIGHT LANDED WITHOUT INCIDENT AT 1957Z.SDR CA110908007Spring Assy · damaged(CAN) LIGHTNING STRIKE ON DESCENT, AT ABOUT 5000`. FOUND EXIT DAMAGE ON RT ELEVATOR SPRING TAB. HOLES BURNED THROUGH TOP AND BOTTOM SKIN AS WELL AS A PIECE BURNED FROM THE T/E. SPRING TAB WAS REPLACED.SDR 3S8R201109020002Rib · cracked429CT FITTING CRACKED ON FINGERNAIL. REPLACED FITTING IAW SRM 54-78-11 AND 51-40-00.SDR CA110830012Pulley · seized(CAN) WHILE INVESTIGATING A DEFECT FOR THE LT MLG FWD DOOR NOT CLOSING AFTER GEAR RETRACTION, THE ACFT WAS PLACED ON JACKS. DURING THE TROUBLESHOOTING OF THE DEFECT, AN ALTERNATE GEAR EXTENSION WAS CARRIED OUT. DURING THE ALTERNATE GEAR EXTENSION THE LT MLG SDR HNAA2011090100264Pcu · failedON CLIMB OUT, NR 2 NP REACHED 1245 AND DROPPED TO 1236, THEN CREW RETARDED TO 1050 AND RETURNED TO FIELD. PROP OVERSPEED WITHIN LIMITS OF MM 61-10-00. R & R NR 2 PCU IAW WC 61-10-10. OPS CHECKED GOOD.SDR CA110825001Actuator · failed(CAN) ACFT EXPERIENCED A ROLL SPOILER THAT FAILED TO EXTEND. ADDITIONALLY, THERE WAS A LOSS OF HYD FLUID. INVESTIGATION REVEALED ROLL SPOILER ACTUATOR PISTON CAP SEPARATION. ACTUATOR WAS REPLACED AND FUNCTION CHECK ACCOMPLISHED.SDR CA110811001Computer · malfunctionedON DEPARTURE THE CREW REPORTED THAT THE NR1 AHRS (ATTITUDE HEADING REFERENCE SYSTEM) WAS OFF BY 10 DEGREES, THEN A MOMENT LATER REPORTED THAT THE NR 2 AHRS WAS DOING THE SAME. ACFT RETURNING TO DEPARTURE. NR 1 AHRS COMPONENT REPLACED. SYSTEM GROUND CHECKED SSDR CA110803020Line · leakingON CLIMB OUT, CREW HAD A LOSS OF THE NR 1 HYD SYS. FLIGHT CONTINUED TO DESTINATION WHERE AN EMERGENCY WAS DECLARED DUE TO NO BRAKE OR STEERING. ACFT LANDED UNEVENTFULLY. MX FOUND A PIN HOLE IN THE NR 1 HYD SYS PRESSURE LINE (PN 82974010-119) (IPC 29-10-00, FSDR CA110803023Terminal Block · corrodedDURING CRUISE FLIGHT AT FL 210, THE CABIN PRESSURE WARNING LIGHT CAME ON AND THE CABIN CONTINUED TO CLIMB TO 11,000 ON ITS OWN. THE CREW HAD NO CONTROL IN AUTO OR MANUAL. THE ACFT DIVERTED. DURING DESCENT THE PRESSURIZATION SYS BEGAN WORKING NORMALLY AGAIN.SDR CA110725010Packing · deterioratedDURING CLIMB, THE CREW RECEIVED A NR 1 ENG HYD PUMP CAUTION LIGHT WITH THE ASSOCIATED PRESSURE AND QUANTITY INDICATORS READING ZERO. AS A RESULT OF THE NR 1 HYD SYS LOSS, THE FOLLOWING SYS WERE INOPERATIVE: FLAPS, INBD ROLL SPOILERS, NORMAL BRAKES, ANT-SKID ASDR CA110718003Line · crackedDEFECT-1000248, COMPLETE LOSS OF NR 2 HYD FLUID AFTER PULLING AWAY FROM THE GATE. LP 618049. (RESOLVED ON W/O: 295549, TASKCARD: NR-00001) FORE AND TRAILING RUDDER REMOVED FOR ACCESS TO HYD LINES. IAW 27-20-11 AMM, LINE IPC REF-27-21-00 15 ITEM 040 . TUBE ASSSDR CA110712003Jackscrew · failedON APPROACH WHEN FLAPS 35 SELECTED, THEY STOPPED AT 15 DEGREES. ON WALKAROUND FOLLOWING LANDING, THE CREW NOTICED THE LT INBD FLAP CAME DOWN ASYMMETRIC AND THE LOWER CORNER DUG INTO THE COMPOSITE PANEL ON THE FUSELAGE AND THE T/E OF THE FLAP WAS DAMAGED. SUSDR CA110630002Tube · leakingDURING CLIMB, CREW OBSERVED THE NR 1 HYD SYS DEPLETING. CREW ELECTED TO CONTINUE ON TO DESTINATION. NEAR DESTINATION, CREW DECLARED AN EMERGENCY AND LANDED WITHOUT FURTHER INCIDENT. LOSS OF THE NR 1 HYD SYS RESULTED IN THE LOSS OF WING FLAPS, INBD ROLL SPOSDR CA110615005Fitting · crackedTHE TAKEOFF WAS REJECTED (BELOW 70 KTS) WHEN THE LT ENGINE OIL PRESSURE WENT TO ZERO. THE RT OIL INLET TUBE ADAPTER FITTING TO THE LT OIL COOLER WAS FOUND BROKEN AND THE TUBE DISCONNECTED. THIS RESULTED IN THE LOSS OF A SUBSTANTIAL AMOUNT OF OIL IN A SHORT PESDR CA110617006Socket · burnedF/A ADVISES THAT THERE IS A BURNING ELECTRICAL ODOR FROM AREA OF 2AC. 547790. DEFECT CONFIRMED SIDEWALL LIGHT SOCKET AT 4AC MELTED. LIGHT DEACTIVATED AND MEL APPLIED. SIDEWALL LIGHT SOCKET ASSY AT 4AC REPLACED, OPS CHECKED SERVICEABLE ACCORDING TO SHOP.SDR CA110610010Actuator · crackedHYD LEAK WAS NOTED FROM THE LT SIDE WING NACELLE AREA DURING ENGINE START UP. UPON CLOSER INSP AFTER ENGINE SHUTDOWN, IT WAS CONFIRMED TO BE COMING OFF THE LT OTBD SPOILER ACTUATOR. THE HSG ON THE ACTUATOR WAS FOUND CRACKED. ACTUATOR REPLACED, ACFT GROUND RSDR CA110607005Actuator · failed(CAN) ON TAKEOFF (AT ABOUT 50 IN THE CLIMB) THE LT INBD ROLL SPOILER DEPLOYED UN-COMMANDED. PASSING THROUGH 1500 IT RETRACTED. THE ACFT RETURNED TO THE BASE WITH NO FURTHER ISSUES. THE LT INBD ROLL SPOILER ACTUATOR WAS FOUND AT FAULT AND WAS REPLACED. SPOI
Back to Pratt & Whitney Canada PW120A