Pratt & Whitney Canada PW123
Service difficulty reports · 1,854
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW123' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW123' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA140116003Fitting · cracked(CAN)NR 1 HYDRAULIC ISO VALVE CAUTION INDICATION DURING CLIMB OUT. HYDRAULIC QTY ALSO LOW. EMERGENCY WAS DECLARED AND THE FLIGHT RETURNED TO AIRPORT. FLAP ZERO LANDING CONDUCTED WITHOUT FURTHER INCIDENT. ONCE ACFT WAS PARKED MAINTENANCE NOTICED HYDRAULIC FSDR CA140119007Engine · malfunctioned(CAN) ON TAKEOFF AT ABOUT 500 FT ALTITUDE, CREW NOTICED THE PROPELLER SPEED WAS INCORRECT AND HEARD THE ENGINE SPOOLING UP. THEY PULLED BACK THE POWER AND THE PROPELLER CONDITION LEVER, NOTICED AN OVERTORQUE CONDITION AND IMMEDIATELY ELECTED TO RETURN TO THE SDR CA140114001Fitting · cracked(CAN) DURING REPLACEMENT OF NR 2 ENGINE ON , AN FITTING FOUND CRACKED AT TWO PLACES ON MAIN FUEL HOSE ASSY, BETWEEN ENGINE AND FIREWALL. THE COMPANY HAS INITIATED A FLEET INSPECTION AS A RESULT OF THIS FINDING.SDR CA140114003Terminal · defective(CAN) AFTER THE ACFT TOOK OFF & DURING CLIMB OUT THE CAPTAINS WINDSHIELD STARTED TO FROST UP. CREW NOTICED THE LT WINDSHIELD HT CB ON THE RT AC PANEL HAD TRIPPED. THE ACFT TURNED BACK & RETURNED TO THE AIRPORT. MAINTENANCE COMPLETED THE FOLLOWING TROUBLESHOSDR CA140115003Line · failed(CAN) DURING A SCHEDULED INSPECTION OF AIRCRAFT, MAINTENANCE DISCOVERED THAT PN 215T63010-66 OIL LINE OF THE OIL REPLENISHMENT SYS LOCATED ON THE LT AND RT ENGINES WAS CHAFING AND WORN. THE TITANIUM ANGLE PN 87140552-101 OF THE LOWER ENGINE COWLINGS IS STRIKISDR CA140106007Indication Sys · failed(CAN) DC POWER MONITOR WENT BLANK AFTER GROUND POWER UNIT WAS PLUGGED IT. UPON INSPECTION FOUND DC POWER MONITOR FAILURE AND DC POWER MONITOR TO BE AT FAULT. DC POWER MONITOR REPLACED WITH SERVICEABLE. ACFT RETURNED TO SERVICE.SDR CA140109005Check Valve · leaking(CAN) WHILE ON THE GROUND AT THE AIRPORT TERMINAL THE FLIGHT CREW STARTED THE ENGINES AND NOTICED THAT THE NR 2 HYDRAULIC SYS FLUID HAD DEPLETED. THE RELATED HYDRAULIC PRESSURE INDICATIONS ALSO ILLUMINATED. THE FLIGHT CREW SHUTDOWN THE ENGINES, ONCE THE FLIGHSDR CA140113001Actuator · failed(CAN) DURING A ZONAL INSPECTION OF THE NR 2 NACELLE IT WAS FOUND THAT 1 OF THE 2 ASSIST SPRINGS LOCATED IN THE MLG UPLOCK ACTUATOR WAS BROKEN. THE LT MLG UPLOCK ACTUATOR WAS THEN INSPECTED AND THE SAME CONDITION, 1 OF THE 2 SPRINGS BROKEN WAS ALSO FOUND. THE SDR CA140106010Bearing · disintegrated(CAN) ACCORDING TO OPERATOR REPORT, AFTER LANDING DURING TAXING VIBRATIONS ARE FELT COMING FROM THE LT SIDE. AFTER ACFT STOPPED, IT WAS FOUND OUT THAT THE LT WHEEL IS DAMAGED AND THAT THE OUTER WHEEL BEARING IS DISLOCATED, GONE. BEARING, WHAT LEFT OF IT, WASDR CA131213011Engine · malfunctioned(CAN) AFTER TAKEOFF, NR 2 ENGINE OIL PASSAGE WARNING LIGHT ILLUMINATED, THEN LOUD THUMP AND ENGINE SHUTDOWN. EMERGENCY DECLARED AND FLIGHT LANDED UNEVENTFULLY. ENGINE BEING SENT TO SHOP FACILITY AND TSB HAS REQUESTED TO BE PRESENT FOR TEARDOWN.SDR CA131216009Engine · failed(CAN) SHORTLY AFTER TAKEOFF, PASSING 2000`, CREW RECEIVED A NR 2 ENGINE OIL PRESSURE WARNING LIGHT, THEN HEARD A LOUD NOISE. EVIDENCE OF FIRE WAS REPORTED ON THE NR 2 ENGINE. BOTH FIRE BOTTLES WERE DISCHARGED EXTINGUISHING THE FIRE. THE ENGINE WAS SHUTDOWN,SDR HNAA2013120900612Gauge · malfunctionedNR 1 ENGINE FUEL TEMP INDICATOR PEGGED FULL HOT. R & R FUEL TEMP GAUGE AND GROUND RAN ACFT. OPS CHECKED GOOD. OK FOR SERVICE.SDR CA131211005Attach Bracket · broken(CAN) WHILE ON APPROACH THE NOSE GEAR DID NOT EXTEND WHEN GEAR WAS EXTENDED. THE CREW RECEIVED A NLG UNSAFE LIGHT. THE TOWER DID CONFIRM THAT THE GEAR DID NOT EXTEND. THE CREW THEN CARRIED OUT AN ALTERNATE GEAR EXTENSION, HOWEVER, THEY STILL HAVE THE UNSAFE SDR CA131218016Engine · overtorqued(CAN) WHILE ATTEMPTING TO UNFEATHER THE NR 2 PROPELLER, FLIGHT CREW REPORTED 124 PERCENT OF TORQUE ON THE NR 2 ENGINE. SOLID STATE FLIGHT DATA RECORDER (SSFDR) WAS DOWNLOADED AND ENGINE DATA FORWARDED TO THE ENGINE MFG. SSFDR DATA ANALYSIS CONFIRMED THE OVERSDR CA131202012Attach Bracket · detached(CAN) ACFT BOARDING LADDER, FORWARD WELDED ATTACHMENT BRACKET ON THE LADDER IS CRACKED IN THE MOUNTING AREA, BRACKET FITS OVER THE AIRFRAME ATTACHMENT LUG. 3 LADDERS IN OUR FLEET WERE FOUND TO BE CRACKED DURING INSPECTION.SDR CA131202008Autofeather Sys · failed(CAN) THE PILOTS REPORTED THE AUTOFEATHER FAILED TO ARM AND ELECTED TO ABORT THE TAKEOFF AND TO RETURN TO THE GATE. TROUBLESHOOTING IS ONGOING. FDR DATA WAS REQUESTED.SDR CA131126007Control Unit · misinstalled(CAN) DURING ROUTINE MAINTENANCE THE RIGHT HAND ENGINE P2.5/P3 SWITCHING VALVE WAS INSPECTED IAW TASK 7230/30. THIS TASK REQUIRES THE DISASSEMBLY OF THE SWITCHING VALVE IAW THE PRATT & WHITNEY MAINTENANCE MANUAL, WHICH REQUIRES A FULL DISASSEMBLY OF THE VALVE.SDR CA131118024Piston · broken(CAN) DURING PRE-FLIGHT WALKAROUND, THE NOSE GEAR SHOCK-STRUT WAS NOTED TO BE FLAT. UPON CLOSER INSPECTION THE BOTTOM FLANGE, WHICH HAS SPANNER WRENCHING FLATS, ON THE PISTON CAP WAS FOUND CRACKED AND BROKEN OFF. THE PISTON CAP WAS REPLACED. TOTAL CYCLES ON TSDR CA131118021Selector Valve · failed(CAN) LANDING GEAR DID NOT EXTEND , PERFORMED ALTERNATE SELECTION , GEAR HANDLE LIGHTS ILLUMINATED AND HAD THREE RED. LANDING GEAR SELECTOR VALVE REPLACED IAW AMM 32-30-41. GEAR SWINGS CARRIED OUT, LEAK AND FUNCTION CHECKED SERVICEABLE.SDR CA131118009Sensor · malfunctioned(CAN) THERE WAS AN UNCOMMANDED AUTOFEATHER ON TAKEOFF ON ONE ENGINE. THE ENGINE FEATHERED JUST AFTER THE AUTO-FEATHER SYS ARMED AT APPROXIMATELY 40 KTS. THE TAKEOFF WAS ABORTED. THE TORQUE SIGNAL CONDITIONING UNIT AND TORQUE SENSOR WERE REPLACED AND THE ACFTSDR JJBA20131107006Bonding Strap · looseBONDING STRAP HANGING FROM LT ENGINE COWLING. SECURED BONDING STRAP.SDR CA131111016Propeller · malfunctioned(CAN) DURING TAKEOFF ROTATION, THE NR 1 PROPELLER FEATHERED. THE TORQUE RAPIDLY INCREASED ABOVE NORMAL OPERATING LIMIT AND FLIGHT CREW SHUTDOWN THE ENGINE. AN EMERGENCY WAS DECLARED AND THE ACFT RETURNED, LANDED WITHOUT FURTHER INCIDENT. SOLID STATE FLIGHT DASDR CA131030004O-Ring · failed(CAN) REF: DEFECT-1139169 LT ISO CL CAME ON, ON ROUTE. HYD QTY IN SYS 1 AFTER LANDING WAS 0.8. NR 1 NACELLE NR 1 HYDRAULICS. FLIGHT SPOILER PRESSURE SWITCH O-RING BLOWN, IPC REF 27-14-00 FIG 52 ITEM140. O-RING P/N-NAS1612-6A , REPLACED,LEAK AND FUNCTION CHSDR CA131023006Skin · corroded(CAN) LEFT ELEVATOR BOTTOM SKIN FOUND WITH BONDLINE CORROSION.SDR CA131023007Skin · corroded(CAN) RIGHT ELEVATOR BOTTOM SKIN FOUND WITH BONDLINE CORROSION.SDR CA131022010Pressure Switch · leaking(CAN) DURING DEFUELLING THE ACFT, WHEN THEY PUT THE THE ACFT FUEL BOOSTER PUMP ON. THE TECH FOUND OUT AT THE RT ENGINE A FUEL LEAK COMING OUT AT THE FUEL FILTER DIFFERIENTIAL PRESSURE SWITCH.SDR CA131018014Bolt · wrong part(CAN) FOUND INCORRECT BOLTS INSTALLED ON REAR ENGINE MOUNTS WHILE PERFORMING TASK MP-54-1, MAGNETIC PARTICLE INSPECTION OF REAR MOUNT BOLTS. MFG IPC CALLS FOR BOLT, PN: LM431-131. FOUND BOLT, PN: MS9208 INSTALLED ON BOTH NR 1 ENG & NR 2 ENG REAR MOUNTS, 4 BOSDR CA131011006Bearing · seized(CAN) DURING HEAVY MAINTENANCE INSPECTION, AILERON SYS, MAINTENANCE HAS NOTICED THAT THE AILERONS INPUT OUTER WING QUADRANT BEARING WAS SEIZED ON THE INPUT LEVER. BEARING WERE REPLACED ASPER AMM.SDR JJBA20131009002Unknown · smokeAFTER STARTING NR 2 ENGINE, CAPTAIN NOTICED SMOKE IN THE CABIN AND COCKPIT AND THE DUCT HOT ANNUNCIATION ILLUMINATED. PERFORMED OPS CHECK OF TEMP CONTROL SYS. COULD NOT DUPLICATE.SDR HNAA2013100400527Switch · out of adjustBETA WARNING HORN SOUNDED AFTER TAKEOFF AT APPROX 50 FT, EXTINGUISHED AT 50 FT DURING LANDING. INSPECTED POWER LEVER TRIGGER SWITCH. FOUND TOO TIGHT. ADJUSTED. COMPLETED OPS TEST IAW AMM 31-51-02. OPS CHECKED GOOD.SDR CA131017010Signal Cond Unit · failed(CAN) ABORTED TAKEOFF DUE AUTO-FEATHER FAILED TO ARM. NR 2 TSCU REPLACED AND ENGINE RUNS C/O CHECKED SERVICEABLE C/O IAW MM 72-01-10. 3X HIGH POWER RUN C/O IAW AMM 71-00-00-05. NO FURTHER REPORT.SDR JJBA20130922013Engine · malfunctionedNR 2 ENGINE TORQUE AND FF FLUCTUATING. LARGE POWER LEVER SPLIT WITH NR 2 REQUIRING MORE INPUT TO ACHIEVE THE SAME POWER AS NR 1 ENGINE. R & R NR 2 ENGINE, OPS AND LEAK CHECKED GOOD.SDR CA130920010Fitting · cracked(CAN) DURING ANNUAL INSPECTION, RT HORIZONTAL STABILIZER-LOWER OTBD FINLET FITTING WAS FOUND SEVERELY CRACKED. MFG CONTACTED FOR REO, REPAIR ENGINEERING ORDER AND PARTS AVAILABILITY. THIS FITTING WAS INSTALLED DURING CONVERSION FROM 215 PISTON TO 215T. DISCUSDR JJBA20130914008Pump · inoperativeDURING CLIMB, NR 2 ENGINE POWER LEVER NOT RESPONSIVE. R & R NR 2 ENGINE MFC AND FUEL PUMP AND RIGGED.SDR CA130916008Case · cracked(CAN) REF: DEFECT-1133302, REPLACE NR 2 ENGINE, SN 123112 DUE TO CRACK FOUND ON TOWER JUST UNDER AND TO THE RT OF HMU FUEL PUMP CLAMP, LEAKING OIL, ORIGINAL DEFECT 1133133 NR 2 ENGINE OIL LEAK RESOLVED ON WO: 400829, TASKCARD: NR-00001, 2 ENGINE REPLACED IAW SDR CA130910001Spu · leaking(CAN) AN ACFT EXPERIENCED PROBLEM ON NR 2 HYDRAULIC SYS DURING APPROACH. THE CREW DECLEARED AN EMERGENCY, PERFORMED ALTERNATE LG EXTENSION AND LANDED. HYDRAULIC LEAKAGE WAS CONFIRMED FROM NR 2 SPU, PN 731840, 2 MECHANICS AND 1 QA INSPECTOR WERE DISPATCHED ONSDR CA130911004Strut · worn(CAN) DURING SCHEDULED ENGINE CHANGE, 1 OF THE REAR ENGINE VERTICAL STRUT WAS FOUND WITH THE BEARING WORN OUT, WAY BEYOND LIMITS. AS PRECAUTIONNARY THE COMPANY HAS INITIATE A FLEET INSPECTION AS A RESULT OF THIS FINDING.SDR CA130924005Pump · fluctuates(CAN) DURING CLIMB IT WAS NOTED THAT THE NR 1 STANDBY HYD PRESSURE WAS FLUCTUATING AROUND 700-1000 PSI. AFTER TRANSITION AND THE PUMP SWITCHED OFF, ENGINEERING ON THE GROUND WAS CONTACTED. REMOVAL/INST OF NR 1 STANDBY HYD PUMP ASSY IAW AMM 32-11-17, EGR C/O SDR CA130909010Propeller · leaking(CAN) DURING ACFT TURN-AROUND FLIGHT CREW NOTICED LARGE AMOUNT OF ENGINE OIL AROUND THE LT PROPELLER & FWD ENGINE COWLS. SUBSEQUENT INVESTIGATION BY MAINTENANCE FOUND THE OIL EMANATING FROM THE NR 3 BLADE SEAL AREA. UPON REMOVAL OF THE BLADE ASSY IT THE BLADSDR CA130830005Skin · debonded(CAN) MULTIPLE AREAS OF MECHANICAL DISBOND FOUND AT FORWARD UPPER FUSELAGE. LOCATION, BS X180, STRS 3S-7S. REPAIR CARRIED OUR IAW RD8-53-13236.SDR CA130826001Spur Gear · cracked(CAN) AT DISASSEMBLY OF THE RGB MODULE, FOR A LIGHT O/H DUE TO MIO (METAL IN OIL), 3 CRACKS WERE NOTED IN THE 2ND STAGE SPUR GEARSHAFT WALL, PN 3108316-01, SN RWA27A159. THE CRACKS ARE ORIGINATING FROM THE NR 15 BEARING MATING FACE AND PROPAGATING FORWARD. THESDR CA130828006Wheel · separated(CAN) STARBOARD OUTER MAIN WHEEL SEPARATION AFTER TAKEOFF. ACFT ARRIVED WITH STARBOARD OUTER MAIN WHEEL MISSING ON LANDING, TAXIED TO PARKING WITHOUT FURTHER INCIDENT. INSPECTION WAS CARRIED OUT ON THE STARBOARD MAIN LEG AND AREAS OF THE FUSELAGE AND EMPENNSDR CA130815008Socket · burned(CAN) DEFECT-1128460, OVERHEAD CEILING LIGHT ASSY SHOWING SIGNS OF ARCING AT 5DF. RESOLVED ON W/O: 396234 TASKCARD, NR-00009. OVERHEAD BIN AT 5DF LOWERED FOR ACCESS, AND RE-INSTALLED. LAMP HOLDER ASSY REPLACED AT 5DF AND LAMP REPLACED. OVERHEAD LIGHTS AT 5DSDR CA130904003Control Unit · malfunctioned(CAN) FROM SDR 210041290, DURING TAKEOFF ROLL, PILOT NOT FLYING (PNF - F/O) NOTED THAT THE AUTO FEATHER WAS "SLOWER THAN NORMAL TO ARM" DURING TAKEOFF ROLL BUT SUBSEQUENTLY ARMED WITHIN LIMITS. SHORTLY AFTER ROTATION AT APPROXIMATELY 50FT AGL, PNF HEARD A CHANSDR CA130918003Connector · failed(CAN) CONDUCTING A VISUAL APPROACH, AT APPROXIMATELY 1600` AGL THE LANDING GEAR WAS SELECTED DOWN. THE AMBER LIGHTS IN THE GEAR HANDLE AND RED GEAR UNSAFE LIGHTS ILLUMINATED BUT THE GEAR DOORS REMAINED CLOSED. THE FO AS PF CALLED FOR FLAP 15 BUT I KNEW THE GEASDR CA130819007Controller · malfunctioned(CAN) DURING TAKEOFF, RIGHT ENGINE EXPERIENCED TQ ROLL BACK UNDER 5 PERCENT. CAPTAIN CORRECTED FOR POWER LOSS AND CO-PILOT CONFIRMED RT TQ READING BELOW 5 PERCENT. RT ENGINE STARTED TO FEATHER THEN RETURNED TO NORMAL. CAPTAIN TRIED TO VERIFY GAUGE READING, ASSDR HNAA2013080500444Starter Gen · failedLEFT MAIN BUSS FAULT OCCURRED WHEN SELECTING NR 1 ENGINE START BUTTON WITH ELECTRICAL SMELL. R & R NR 1 STARTER GENERATOR IAW WC 24-30-02R. START CONTACTOR 2431K1 WAS REPLACED IAW MM 24-31-09. OPS AND LEAKED CHECKED GOOD.SDR CA130802003Collar · cracked(CAN) OPERATOR REPORTED DISCOVERY OF DAMAGED BLADE COLLAR DURING ROUTINE AFTER FLIGHT INSPECTION. SOME MATERIAL OF THE COLLAR WAS NOTED AS MISSING. NO OTHER INFORMATION TO REPORT. BLADE HAS BEEN SENT FOR INSPECTION AND REPAIR. PHOTO IN ATTACHMENTS. HS BULLETSDR JJBA20130731014Pump · malfunctionedNR 1 ENGINE FLUCTUATED. R & R ENGINE MFC/HP FUEL PUMP. OPS AND LEAK CHECKS SATISFACTORY.SDR CA130917003Fms · failed(CAN) SMOKE STARTED TO STREAM FROM THE FMS IN FLIGHT, QRH ACTIONED, OXYGEN DONNED, PAN STATUS AND SQUAWKED 7700 ON THE TRANSPONDER. SIGNIFICANT COMMUNICATION ISSUES AROSE THROUGH THE USE OF OXYGEN MASKS EVEN THOUGH THE CORRECT PROCEDURE OF SWITCHING THE INTERP
Back to Pratt & Whitney Canada PW123