SDR CA110531003Hose · misinstalledFIRE WARNING DURING INITIAL CLIMB PHASE, THE PILOT RECEIVED A NR 2 ENGINE FIRE WARNING. THE ENGINE WAS SHUTDOWN AND THE ACFT RETURNED TO THE DEPARTURE POINT WHERE AN UNEVENTFUL SINGLE ENGINE LANDING WAS PERFORMED. TROUBLESHOOTING FOUND A FUEL LEAK FROM THE TOSDR CA110516010Turbine Blades · damaged(CAN) ABORTED TAKE-OFF, DURING T/O, THE FLIGHT CREW HEARD NOISES FROM ENGINE NR 2 AND THEY ABORTED T/O. THE ACFT WAS BROUGHT BACK TO THE DEPARTURE AREA WHERE INSPECTION OF THE EXHAUST SHOWED SECOND STAGE POWER TURBINE BLADES DAMAGE. THE ENGINE WILL BE REPLACSDR TRBA2011036Light · detachedEMERGENCY FLOOR LIGHT IN FRONT OF GALLEY CART IS BROKEN. RE-ATTACHED GALLEY EMERGENCY FLOOR LIGHT IAW JIC 33-51-24. NO OTHER DEFECT NOTED.SDR CA110413009Indication Sys · false indication(CAN) LOW OIL PRESSURE/IFSD DURING FLIGHT, THE ENGINE OIL PRESSURE GRADUALLY DROPPED INTO THE YELLOW BAND, THE CREW ELECTED TO SHUT THE ENGINE DOWN BEFORE RETURNING TO THE DEPARTURE AIRPORT WHERE AN UNEVENTFUL SINGLE ENGINE LANDING WAS PERFORMED. POST FLIGHTSDR JJBA2011331224Light · inoperativeDURING PRE-FLIGHT INSP, AIRCREW NOTICED SOME OF THE EMERGENCY LIGHTS INOPERATIVE WHEN TESTING. AIRCREW RESET SYS POWER AND PERFORMED OPS CHECK OF THE EMERGENCY LIGHTING SYS. SYS CHECKED SATISFACTORY. ACFT RELEASED TO FLIGHT STATUS.SDR CA110413004Engine · unknown(CAN) ABORTED T/O THE CREW ABORTED T/O ROLL FOLLOWING ENGINE NR 2 AUTOFEATHER. ACFT RETURNED TO THE GATE WHERE TROUBLESHOOTING IS CURRENTLY TAKING PLACE. TROUBLESHOOTING LEADS TO AFCU REPLACED AS PRECAUTIONARY.SDR TRBA2011030Seal · failedDURING IDLE DESCENTS, BOTH HP VALVES ON, EXHAUST ODOR COMES THROUGH AIR SYS. R & I NEW PROBE DUMMY PLUG SEALS ON NR 2 ENGINE IAW MM 72-01-60. OPS CHECK GOOD NO EXHAUST ODORS AT THIS TIME. NO LEAKS NOTED AT PROBE.SDR CA110331012Engine · shutdown(CAN) IFSD AFTER T/O, THE NR 2 ENGINE SUFFERED AN UNCOMMANDED SHUTDOWN. THE CREW PERFORMED AN AIR TURNBACK AND AN UNEVENTFUL SINGLE ENGINE LANDING FOLLOWED AT ORIGIN AIRPORT. TROUBLESHOOTING IS ON-GOING.SDR CA110331007Wire Harness · damaged(CAN) ABORTED T/O UPON APPLYING POWER FOR T/O, THE ENGINE TEMPERATURE REACHED 800C BEFORE THE THROTTLE MAX STOP WAS REACHED. ALL OTHER PARAMETER WERE NORMAL. THE T/O WAS ABORTED AT A SPEED OF 70KTS. TROUBLESHOOTING IS ON-GOING AND FOCUSING ON A POSSIBLE INDISDR TRBA2011029Firewall · crackedCRACK ON THE NACELLE REAR SECTION AT THE ANGLE BELOW THE FIREWALL ASSY. INSTALLED NR 2 ENGINE FIREWALL FLANGE IAW SRM 51-25-04.SDR TRBA2011028Lamp · burnedSTAIR LIGHT BURNED OUT ON PAX DOOR STEP. REPLAMED PAX DOOR STAIR LIGHT IAW JIC 33-20-00.SDR TRBA2011022Battery Pack · failedFWD EMERGENCY LIGHTS (INTERIOR) WILL NOT STAY ON. R & R BATT PACK ON POWER SUPPLY FIN NR 43WL IAW W/C 335121, RAI 10010-007. OP CHECK IAW W/C 335000-OPT-10000-002. FOUND GOOD.SDR TRBA2011017Unknown · fumesAFTER NR 1 ENGINE START AND THE NR 1 BLEED SELECTED ON. STRANGE FUMES ENTERED COCKPIT WITH A FAINT BLUE HAZE. BLEED WAS SELECTED OFF AND ODOR DISIPATED. RAN BOTH ENG IAW 72-00-00 CHECKED TEMP AND FULL COLD AND HOT IAW 21-61-00 COULD NOT DUPLICATE.SDR TRBACPCP2011002Support Bracket · corrodedRT WING SPOILER BRACKET SUPPORT SHOWS INTERGRANULAR CORROSION. R & R RT WING SPOILER BRACKET SUPPORT IAW SRM:57-70-00.SDR TRBA2011015Control Unit · erraticDURING DESCENT NR 1 ENGINE LOST POWER FOR 10 SECONDS OR LESS. ENG WARNING ON CAP NR 1 TORQUE INDICATE WENT TO ZERO & ACW GEN WENT OFF LINE. POWER RETURNED TO NORMAL. PERFORMEDED OPS CK IAW EX-055007-CS-20000-001. COULD NOT DUPLICATE THE PROBLEM. OPS CHECKED SDR CA110214009Engine · power lossUNCOMMANDED AUTOFEATHER WHILE ON APPROACH AT APPROX. FL40, THE CREW NOTED A MOMENTARY DROP IN POWER TURBINE SPEED AND TORQUE. THE ENGINE POWER RECOVERED TO NORMAL SETTINGS 12 SECONDS LATER WITH NO PILOT INPUT. AN UNEVENTFUL LANDING FOLLOWED. MULTIPLE FAULTS SDR CA110208012Engine · failed(CAN) ENGINE SHUTDOWN DURING PUSHBACK WHILE THE AIRCRAFT WAS BEING PUSHED BACK FROM THE GATE, SMOKE STARTED COMING OUT OF THE EXHAUST ALONG WITH HIGH ITT INDICATION ON LT ENGINE. ENGINE WAS SHUTDOWN AND AIRCRAFT WAS BROUGHT BACK TO THE GATE WHERE AN INSPECTIONSDR TRBA2011014Lens · missingLENS TO THE EMERGENCY LIGHT MISSING ON THE GALLEY FLOOR. RAR GALLEY EMERGENCY LIGHT IAW ATR 72, JIC 33-50-00. OPS CHECK OK. NO FURTHER DEFECTS NOTED.SDR TRBA2011013Controller · failed(EMERGENCY DECLARED) DURING CRUISE FLIGHT, NR 2 ENGINE PROPELLER FEATHERED AND GOT EEC NR 2 FAULT, IAW CREW DEBRIF, CREW SHUTDOWN NR 2 ENGINE PRECAUTIONARY IAW MFG PROCEDURES. NR 2 ENG PCU REPLACED IAW MM 61-22-00, OPT CHECK AND LEAK CHECK GOOD, ALSO REFERSDR TRBA2011012Acm · seized(DECLARED EMERGENCY) AFTER LANDING 13R & TAXI IN WHILE CROSSING 18L AND SELECTING REVERSE TO SLOWDOWN A STRONG ACRID ODOR OF SMOKE WAS NOTED FROM COCKPIT AND ALSO NOTED IN FWD AND REAR CABIN. THE F/O SAW WHITE SMOKE ORIGINATING FROM TOP OF GLARESHIELD VENTS OVSDR CA110208003Fuel Nozzle · leaking(CAN) IFSD DURING FLIGHT, ENGINE SHUT DOWN UNCOMMANDED, 40 NAUTICAL MILES FROM DEPARTURE POINT. POST-FLIGHT VISUAL BY LAO STAFF REVEALED FUEL LEAK AT NR 6 OR 7 FUEL NOZZLE.SDR CA110208011Engine · failed(CAN) ABORTED TAKE-OFF CREW REPORTED SLUGGISH BEHAVIOR ON LT ENGINE AND RH ENGINE TORQUE FLUCTUATION DURING TAKE-OFF ROLL AND ROTATION. THE AIRCRAFT RETURNED TO POINT OF DEPARTURE AND TROUBLESHOOTING IS ONGOING WITH MANUFACTURER ASSISTANCE.SDR CA110125014Oil System · low pressure(CAN) OIL PRESSURE LOSS/IFSD DURING FLIGHT, THE NR 2 ENGINE LOW OIL PRESSURE WARNING CAME ON. THE ENGINE WAS SHUT DOWN AND AN UNEVENTFUL SINGLE ENGINE LANDING FOLLOWED. GROUND INSPECTION FOUND NO OIL LEVEL VISIBLE IN THE SIGHT GLASS, OIL WAS FOUND INSIDE THE ESDR TRBA2011008Lamp · inoperativeEMERGENCY LIGHT MAIN CABIN DOOR INOP. R & R LIGHT BULB IAW MM 33-51-24. CHECKED AND SECURED WIRING. REPAIRED IAW STD PRACTICES 20-10-00.SDR TRBA2011004Lamp · inoperativeEMERGENCY EXIT LIGHT ON MAIN CABIN ENTRY DOOR IS INOP. R & R EMERGENCY EXIT LIGHT BULB ON MAIN CABIN ENTRY DOOR IS IAW AMM 33-50-00. OPT GOOD.SDR TRBA2010151Light · inoperativeGROUND FLOOD LIGHT ON BOTTOM STEP OF MAIN CABIN ENTRY DOOR IS INOP. OPS CHECKED FLOOD LIGHT EMERGENCY LIGHT AT MAIN CABIN DOOR BOTTOM STEP FOUND WORKING PROPERLY TESTED OK IAW JIC 33-50-00.SDR TRBA2010152Bulb · inoperativeFLOOR PROXIMITY, EMERGENCY ESCAPE PATH MARKING SYS HAS MULTIPLE BULBS LIGHT THAT DO NOT ILLUMINATE. OPS TESTED EMERGENCY ESCAPE PATH LIGHT AT FLOOR IAW JIC 33-50-00 WORKING PROPERLY.SDR 2011F00001Power Supply · inoperativeFWD EMERGENCY LIGHTS FAIL TEST. POWER SUPPLY INOPERATIVE.SDR TRBA2010150Cover · brokenFLOOR EMERGENCY LIGHT IN GALLEY MISSING PLASTIC COVER. R & R PROXIMETY LIGHT STRIP IN GALLEY IAW JIC 33-51-21.SDR TRBA2010149Socket · burnedELECTRICAL SMOKE ODOR IN CABIN. AT THIS TIME OPENED MIDDLE TO AFT OVERHEAD BINS, FOUND BURNED LIGHTSOCKET AT OVERHEAD 12AB. REMOVED LIGHT SOCKET AND DEFERRED ON MEL 33-02 AUTH NR 120088-C FIN NR303LGA. CLOSED BINS IAW MM 25-24-21. R & R CEILING LIGHT 12AB BUSDR TRBA2010148Symbol Generator · inoperativeELECTRICAL SMOKE, "EMERGENCY DECLARED" R & R NR 2 SYMBOL GENERATOR. OPS CK OK IAW JIC 34-71-82.SDR TRBA2010146Battery Pack · inoperativeEMERGENCY LIGHTS ARE ON AT ALL TIMES IN FWD CABIN. R & R FWD EMERGENCY LIGHTS POWER SUPPLY 43WL AND POWER SUPPLY BATTERY PACK IAW JIC 33-51-21 10000 AND 33-51-21 10010. OPS TEST SATISFACTORY.SDR TRBA2010145Light · malfunctionedEMERGENCY EXIT LIGHTS REMAIN ILLUMINATED AFTER BEING TURNED OFF/ARMED. RESET SYS AND OPS CHECKED GOOD IAW AMM JIC 33-50-00 OPT 10000 ACFT, OK FOR SERVICE.SDR TRBA2010144Power Supply · inoperativeDURING PREFLIGHT LT FWD EXTERIOR EMERGENCY EXIT FLOOD LIGHT INOP. R & R EMERGENCY POWER SUPPLY FIN NR61WL IAW JIC 33-51-21 OPT CHECK WORKING PROPERLY.SDR TRBA2010143Bulb · misinstalledEMERGENCY LIGHT INOP AT ROW 3. EMERGENCY LIGHT AT ROW 3 DEFERRED MEL 33-29 AUTH 110158-C. FOUND BULB IMPROPERLY SEATED IN SOCKET. RESEATED BULB. ROW 3 EMERGENCY LIGHT OPC GOOD IAW JIC 33-50-00. MEL ITEM RESTORED.SDR TRBA2010140Unknown · smokeSMOKE IN CABIN W/E2 RUNNING NR2 BLEED AND NR2 PAC ON, TEMP SEL TO HEAT WAS ABLE TO CLEAR A LITTLE W/BOTH PACS IN COOL. PERFORMED OPS CHECK OF TEMPERTURE CONTROL SYS IAWJIC 21-6-00. NORMAL OPERATION NOTED.SDR TRBA2010139Unknown · odorELECRICAL SMOKE, MW & CRC DURING NR1 ENGINE START, ODORS IN CABIN. PERFORMED NR 1 ENG RUN UP IAW JIC 72-00-00 AND NO SMOKE ODOR FOUND IN CABIN. CLEANED ELECTRICAL RACKS, SMOKE DETECTOR AND CONNECTOR AND PERFORMED OPS CHECK OF SMOKE DETECTION SYS IAW JIC 26-15SDR TRBA2010138Cover · brokenEMERGENCY LIGHT ON FLOOR AT SEAT 1 BC DOES NOT ILLUMINATE AND COVER BROKEN OFF. SECURED COVER AND ADJUSTED LIGHT BULB ON FLOOR EMERGENCY LIGHT 1 BC IAW ATR JIC 72.SDR TRBA2010135Wire · disconnectedEMERGENCY LT IN CABIN DOOR STEPS INOP. RECONNECTED LAMP WIRE IAW SMP 20-45-00. OPS CK GOOD.SDR TRBA2010136Lamp · inoperativeONE EMERGENCY EXIT LIGHT NOT WORKING IN REAR. RELAMPED WITH BULB FROM SPARE BULB KIT IAW MM 33-60-00. OPS CK GOOD.SDR TRBA2010137Insulation · out of positionDURING CLIMB AT ABOUT 5000 FT F/A REPORTED DETECTING A BURNING RUBBER ODOR AND HEAT AT HER FEET IN HER FWD JUMPSEAT. INSPECTED FWD INTERIOR OF ACFT AND FOUND HEATER SELECTED AND A INSULATION OUT POSTION CAUSING THE FUNNY ODOR, RESECURED INSULATION, OPS CHECK SDR TRBA2010134Light · inoperativeSERVICE DOOR EMERGENCY EXIT LIGHT INOP. ADJUSTED FLOOD LIGHT NEXT TO EMERGENCY EXIT SERVICE DOOR IAW JIC 33-50-00, OPS CK GOOD AT THIS TIME.SDR TRBA2010133Connector · dirtyLT MAIN GEAR WOULD NOT RETRACT AFTER T/O STAYED DOWN AND LOCKED PLUS RED UNLOCK WAS ON, (DECLARED EMERGENCY) PLACED ON MEL 32-03 AUTH NR110015DMC. CLEANED CORRODED CONNECTOR AT LT MLG WOW PROX SWITCHES 50GB & 51GB, RESECURED WIRE BUNDLE TO SELECTOR VALVE 13GA,SDR TRBA2010130Fire Detector · false activationWHEN WAITING TO PARK ACFT, NR 1 ENGINE FIRE. DISCHARGED AGENT 1 AND FIRE WENT OUT, WIND WAS 110 AT 3 KNOTS. "DECLARED EMERGENCY" R & R FIRE BOTTLE IAW JIC 26-21-71-RAI 10000 AND CARTRIDGE IAW JC EX-262172-RAI-10000. OPS CHECK GOOD. CLEANED AND INSPECTED ESDR TRBA2010132Bpcu · failedTOTAL ACFT ELECTRICAL FAILURE (BOTH BUSES + INVERTERS) EMERGENCY DECLARED. R & R DC BPCU IAW AMM JIC 24-46-83-RAI-10000 AND JIC 72-00-00-ERU-10000. R & R ACW BUS POWER CONTROL UNIT IAW JIC 24-41-83-RAI-10000-001. OPS CHECK GOOD NO ELECTRICAL DISCREPANCIES NOTESDR TRBA2010131Fan · failedEXHAUST FAN FAULTED WHILE TAXIING TO RUNAWAY. BURNING ODOR IN COCKPIT. AT THIS TIME EXHAUST EXTRACT FAN DEFERRED IAW MEL 21-6 AUTH NR100180D-C. MEL CLEARED ON 1-25-10 AT SJU: R & R AIR EXTRACTION FAN IAW JIC 21-23-21. OPS TEST FOUND OK IAW JIC 21-23-00-OPT-1SDR TRBA2010123Hose · looseBURNING ODOR IN BOTH COCKPIT AND CABIN AS ACFT PULLED INTO RAMP. ODOR DISSAPATED WHEN AC PACKS TURNED OFF. TIGHTENED LOOSE HOSE AT R/S HEAT EXCH. IAW JIC 21-51-51 AND UNCLOGGED L/S ACM WATER SPRAY NOZZLE IAW JIC 21-51-91. PERFORMED ENGINES GRD RUN IAW JIC 1SDR TRBA2010119Brake · wornBRAKES ARE SPONGY. PEDALS CAN BE PRESSED ALL THE WAY TO THE STOPS. R & R NR 2 AND 4 BRAKE ASSY IAW JIC 32-42-55-RAI-10000-005.SDR TRBA2010120Wire · damagedPASSENGER STAIR EMERGENCY LIGHT BURNED OUT. REPAIRED WIRE AT MAIN DOOR CONNECTOR IAW STD PRACTICE ,OPT CK GOOD IAW MM 52 70 00.SDR TRBA2010116Warning Light · illuminatedUNSAFE LANDING GEAR ON THE LT MAIN GEAR ON BOTH PANEL. FOLLOW THE AOE MANUAL CHECK LIST AND RETURNED TO DEPARTURE. (DECLARED EMERGENCY) REMOVED WATER AND CLEANED LT MLG PROXIMITY SWITCHES (WOW) AND PERFORMED NORMAL EXTENSION AND RETRACTION FUNCTIONAL TEST IAW
Back to Pratt & Whitney Canada PW127