Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2012072500728Stop Pin · wornFWD RT EMERGENCY EXIT UPPER, MIDDLE AND LOWER BACK UP STOP PINS ALONG AFT EDGE OF DOOR HAVE WEAR. BLENDED IAW SRM 51-14-00-02-04. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLENDED AREAS FOUND TO BE WITHIN LIMITS IAW RD 8/4-52-805. PRIMED IAWSDR QXEA2012072500729Stop Pin · wornFWD RT EMERGENCY EXIT UPPER AND MIDDLE BACK UP STOP PINS ALONG FWD EDGE OF DOOR HAVE WEAR. BLENDED IAW SRM 51-14-00-02-04. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-06-910-801, PT 1. BLENDS FOUND TO BE WITHIN LIMITS IAW RD 8/4-52-805. PRIMED IAW RDSDR QXEA2012072500730Threshold · corrodedFWD PAX DOOR THRESHOLD PLATE BETWEEN STA X8.00 AND 24.000 HAS AREAS OF CORROSION ON TOP AND BOTTOM SURFACES. REMOVED THRESHOLD FOM IAW SRM 51-42-05-02-01. FOUND TO BE OUT OF LIMITS IAW SRM 53-20-23-02-01. THRESHOLD CHANNEL FOUND TO BE OUT OF LIMITS IAW SRM SDR QXEA2012072500732Structure · corrodedFWD PAX DOOR STEP ASSY AFT GOOSENECK AND AFT GOOSENECK BACKING PLATE HAS CORROSION. REMOVED AFT GOOSENECK REF AMM 52-11-23-000-801. DRILLED NEW GOOSENECK REF AMM 52-11-23-400-801. REPLACED BACKING PLATE WITH NEW FROM STOCK. INSTALLED GOOSENECK AND GOOSENECSDR QXEA2012072500734Light · no testFLOOR PATH LIGHTING INBD OF FORWARD CARGO BAY FAILED 10 MINUTE ILLUMINATION TEST. REPLACED EFFECTED FLOOR STRIP.SDR QXEA2012072500735Light · damagedCABIN FLOOR PATH LIGHTING STRIP DISBONDED AND OR DISCOLORED AT ROW 4 AND ROW 2. REPLACED EFFECTED LIGHT STRIPS.SDR QXEA2012072500739Light · overheatedF/A REPORTS ELECTRICAL BURNING ODOR IN AFT CABIN AREA. FOUND TO BE LIGHTS IN AFT CARGO COMPARTMENT. REPLACED BOTH AFT CARGO BAY LIGHT ASSYS & TERMINAL LUGS. OPS CHECKED GOOD. RETURNED TO SERVICE.SDR QXEA2012072400740Transducer · malfunctionedBRAKES INEFFECTIVE ON LANDING ROLL OUT. ON POST FLIGHT FOUND NR 1 & 4 BRAKES COOL AND NR 2 & 3 HOT. R & R RT INBD WHEEL SPEED TRANSDUCER IAW AMM TASKS 32-46-11-000-801 AND 32-46-11-400-801. PERFORMED FUNCTION CHECKS IAW AMM TASK 32-46-00-720-801 AND 32-46-SDR CA120801007Engine · failed(CAN) DURING CLIMB, PILOT REPORTED A LOUD RUMBLE FOLLOWED BY A YAW, NR 1 ENGINE ITT WENT IN TO THE RED WITH NP AND TQ FLUCTUATING. PILOT SHUTDOWN THE NR 1 ENGINE. ACFT SAFELY RETURNED. ENGINE REMOVED AND SENT TO MFG FOR INVESTIGATION. ENGINE CHANGE COMPLETEDSDR CA120802005Oil System · overtemp(CAN) DURING CLIMB, A LOUD RUMBLE WAS FOLLOWED BY ACFT YAW WITH NR 1 ENGINE TEMPERATURE GOING INTO THE RED BAND AND TORQUE FLUCTUATING. THE PILOT ELECTED TO SHUT THE ENGINE DOWN BEFORE RETURNING TO THE DEPARTURE POINT WHERE AN UNEVENTFUL SINGLE ENGINE LANDINGSDR QXEA2012072300716Light · damagedEMERGENCY FLOOR PATH LIGHTING AT ROWS 18-19 HAVE DISCOLORED LAYERS. ALSO STRIPS AT FORWARD CARGO BAY AREA DISCOLORED AND IN FRONT OF THE G6 GALLEY. REPLACED ALL EFFECTED STRIPS AS REQUIRED IAW 33-51-16-00-801 AND 33-51-196-400-801.SDR QXEA2012072300717Light · damagedDISCOLORED FLOOR PATH LIGHTING STRIPS ALONG THE G6 GALLEY AREA AND THE FORWARD CARGO DOOR AREAS. REPLACED AS REQUIRED.SDR QXEA2012072300726Frame · corrodedFRAME BS 236.00 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 29P AND 30P. REMOVED CORROSION IAW SRM 51-21-00-00-02. REMAINING THICKNESS .038", CONFIRMED CRACK FREE. MATERIAL LOSS WITHIN LIMITS. RESTORED SURFACE PROTECTION.SDR QXEA2012072300725Frame · corrodedFRAME BS 136.0 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 31P AND 33. REMOVED CORROSION FROM FRAME X136 IAW RD 8/4-53-2344. REMAINING THICKNESS 0.39. CONFIRMED CRACK FREE. MATERIAL LOSS WITHIN LIMITS. APPLIED SURFACE PROTECTION AND PROTECTIVE COATINGS.SDR QXEA2012072300723Frame · corrodedFRAME X32.400 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 32P TO 32S. BLENDED CORROSION IAW RD 8/4-53-2344. REMAINING MATERIAL IS 0.38". CONFIRMED CRACK FREE. ALODINED AND PRIMED AREA AND PAINTED.SDR QXEA2012072200718Light · damagedEMERGENCY FLOOR PATH LIGHTING STAINED TOP COAT AT ROWS 20 AND ROW 1 AND AFT GALLEY. REPLACED EFFECTED STRIPS AS REQUIRED.SDR QXEA2012072100719Light · damagedEMERGENCY FLOOR PATH LIGHTING AT FORWARD ENTRY, LT SEGMENTS 2 & 11 AND RT SEGMENT 10, REQUIRE REPLACEMENT. REPLACED EFFECTED SEGMENTS AS REQUIRED IAW CMM 33-51-01.SDR QXEA2012072100721Switch · damagedEMERGENCY LIGHT SWITCH COVER ADJACENT TO FWD F/A JUMP SEAT DAMAGED. R & R MAPCO SWITCH COVER BY DOOR. OPS CHECK GOOD, A/C OK FOR SERVICE.SDR QXEA2012071900713Light · damagedTHE EMERGENCY FLOOR PATH LIGHTING DISCOLORED IN FRONT OF THE BAGGAGE DOOR (FWD) AND ALSO IN FRONT OF ROW 1. REPLACED AS REQUIRED IAW TC 6-33-70.SDR QXEA2012071900714Light · unserviceableFLOOR PATH LIGHTING REQUIRED REPLACEMENT AT LT SIDE SEGMENT 1, RT EMERGENCY EXIT, RT SEGMENT 6, RT SEGMENT 9. REPLACED ALL AS REQUIRED IAW AMM 33-51-16-00-801 AND 33-51-16-400-801.SDR QXEA2012071900715Light · damagedFLOOR PATH LIGHTING STRIP DISCOLORED AT RT NR 7 SEGMENT, LT NR 1 SEGMENT. REPLACED AS REQUIRED IAW CMM 33-51-01.SDR QXEA2012071900720Actuator · malfunctionedON CLIMOUT PASSING THROUGH APROX 12,000 FT, NOTED OIL TEMP AT 107 DEG AND CLIMBING ON THE NR 2 ENGINE. CONDUCTED THE HIGH OIL TEMP CHECKLIST, WHICH REDUCED THE POWER AND MONITORED FOR 10 MINUTES, FOLLOWING 10-12 MINUTES OIL TEMP WAS AT 113 DEG AND THE NR 2 ENSDR QXEA2012071900698Bearing · corrodedAFT RT SERVICE DOOR 2 LIFT AND LATCH MECHANISM SHAFT BEARINGS HAVE CORROSION. REPLACED BEARINGS IAW AMM 52-41-11-400-801.SDR CA120801010Valve · failed(CAN) AIR TURNBACK FOR NR 1 ENGINE HIGH OIL TEMPERATURE. CLIMBING THROUGH FL200, NR 1 ENGINE OIL TEMPERATURE INCREASED BEYOND 107 DEGREES. FAULT CODE 737 RETRIEVED FROM CDS. OIL COOLER THERMAL VALVE REPLACED. ACFT RETURNED TO SERVICE.SDR CA120801013Actuator · failed(CAN) DURING CLIMB, NR 2 ENGINE OIL TEMP CLIMBED TO 113 FOR 12 MINS. FLIGHT CREW COMMANDED IN FLIGHT SHUTDOWN AFTER A HIGH OIL TEMPERATURE WAS NOTED, IAW CHECK LIST. ACFT LANDED BACK AT AIRPORT. MAINTENANCE ACTION, OIL COOLER DOOR ACTUATOR REPLACED. ACFT RSDR QXEA2012071800705Light · damagedEMERGENCY FLOOR PATH LIGHTING HAS STAINED TOP COATING ROWS 1, 7, 12, AND 20. REPLACED EFFECTED PATH LIGHT STRIPS.SDR QXEA2012071800706Light · deterioratedCABIN FLOOR PATH LIGHTING DETERIORATED AT SEGMENTS 1, 2, 4, 6, 7, 8, 10, 11, AND FORWARD CARGO BAY AREA. REPLACED EFFECTED EMERGENCY LIGHT STRIPS.SDR QXEA2012071800710Light · delaminatedDELAMINATED AND UNSERVICABLE FLOOR PATH LIGHTING AT 9 AND 10. REPLACED.SDR QXEA2012071800711Light · deterioratedFLOOR PATH LIGHTING FROM THE WINDAGE BULKHEAD TO THE CENTER OF THE CABIN IS ALL DISCOLORED. REPLACED.SDR QXEA2012071800712Light · unserviceableEMERGENCY FLOOR PATH LIGHTING STRIP AT THE CABIN ENTRY TO THE CENTER CABIN IS UNSERVICABLE. REPLACED THE FLOOR PATH LIGHTING AS REQUIRED.SDR QXEA2012071800699Frame · corrodedFRAME X281 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 27P AND 32P. REMOVED CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS .030". CONFIRMED CRACK FREE. REMOVED MATERIAL FOUND TO BE OUT OF LIMITS BETWEEN STRINGERS 31P AND 32P. REMOVED DAMAGED FLANGE ANSDR QXEA2012071800696Frame · corrodedFRAME X489.500 LOWER FLANGE HAS CORROSION BETWEEN STRINGER 23P AND 24P. REMOVED 3 RIVETS AND CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .031", CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. CORROSION IS LISDR QXEA2012071800700Frame · corrodedFRAME FLANGE AT STA 236 BETWEEN STR 23P 24P HAS CORROSION. REMOVED 2 RIVETS TO FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. CORROSION FOUND TO BE LIMITED TO THE REINFORCING ANGLE ON TOP OF FRAME FLANGE AND IS OUT OF LIMITS IAW SRM 5SDR QXEA2012071800702Bearing · migratedCHAFING ON FORE RUDDER UPPER PCU ATTACH FITTING DUE TO MIGRATED BEARING. REMOVED PCU ACTUATOR ROD IAW AMM 27-23-06-000-801. REMOVED BEARING AND BLENDED ATTACH FITTING IAW SRM 51-41-20-02-02, TEMP REV 55-002. MIN REMAINING THICKNESS NOTED .375", CONFIRMED CRSDR QXEA2012071800703Attach Fitting · chafedCHAFING ON FORE RUDDER LOWER PCU ATTACH FITTING DUE TO MIGRATING BEARING. REMOVED PCU ACTUATOR ROD IAW AMM 27-23-06-000-801. REMOVED BEARING AND BLENDED ATTACH FITTING IAW SRM TEMP REV 55-002 AND 55-41-20-02-02. CONFIRMED AFFECTED AREA CRACK FREE, MIN REMAISDR QXEA2012071800704Skin · dentedLEFT EXTERIOR FUSELAGE MULTIPLE DENTS IN AREA BETWEEN STATIONS X281.00 X321.00 AND STRINGERS 15L AND 21L. DENT DAMAGE FOUND TO EXCEED LIMITS OF RD 8/4-53-666. CONFIRMED DAMAGE CRACK FREE REF NTM 51-00-01-250-801 PT 6. RECEIVED RD 8/4-53-4591 PERMANENT REPAISDR QXEA2012071700690Transducer · malfunctionedBRAKES FELT WEAK. INBD BRAKES FELT HOTTER THEN THE OTBD BRAKES. BRAKE TEMP SPLIT 100 DEGREES INBD TO OTBD. PLACED ANTI SKID SYS ON MEL 32-40-2. CLEARED ON 7/17 BY: PERFORMED FUNCTIONAL TEST OF THE ANTI-SKID SYSTEM IAW AMM 32-46-00-720-802. BRAKE PRESSURESSDR QXEA2012071700691Unknown · odorBOTH F/A'S REPORT ODOR OF SULFER IN AFT GALLEY. AROUND ROW 19 & 20. AB & CD. INSPECTED AIRCRAFT, COULD NOT DUPLICATE. RETURNED TO SERVICE.SDR QXEA2012071700707Light · dirtyALL EMERGENCY FLOOR PATH LIGHTING STRIPS ARE DIRTY. CLEANED AND OR REPLACED AS REQUIRED.SDR QXEA2012071700708Light · damagedEMERGENCY PATH LIGHTING AT ROWS 5-6 IS DISCOLORED. REPLACED AS REQUIRED.SDR QXEA2012071700722Bulb · inoperativeFORWARD PASSENGER OVERHEAD SIGN HAS SEVERAL BULBS INOPERATIVE. RELAMPED. OPS CHECKED GOOD.SDR QXEA2012071700709Light · deterioratedEMERGENCY FLOOR PATH LIGHT RUNNING IN FRONT OF THE FORWARD CARGO DOOR IS DETERIORATED. REPLACED IAW AMM 33-51-16-000-801 AND 33-51-16-400-801.SDR QXEA2012071700695Frame · corrodedFRAME X156.000 LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 23S AND 24S. REMOVED 4 RIVETS AND CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .028", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 AND 51-00-06-910-801 PT 1. CORROSION LIMITSDR QXEA2012071600669Battery Pack · inoperativeCABIN CEILING EMERGENCY LIGHTS AT STATIONS X341, X459, X584, X683, AND CEILING EXIT LIGHT DO NOT ILLUMINATE WHEN SELECTED FROM EITHER COCKPIT OF F/A LOCATIONS. REPLACED POWER SUPPLY. OPS CHECKS GOOD. RETURNED TO SERVICE.SDR QXEA2012071600694Seat Track · corrodedRT INBD SEAT TRACK NR 11 HAS AREAS OF CORROSION BETWEEN STA X10.500 AND X102.500. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACK NR 11 IAW SRM 51-40-15-02-01 AND SRM 51-42-05-02-01. MATCH DRILLED NEW SEAT TRACK IAW SRMSDR QXEA2012071600701Frame · crackedFRAME 49.500 IS CRACKED BETWEEN STRINGERS 30S AND 29S. REMOVED RIVETS COMMON TO FRAME AND SKIN IAW SRM 51-42-05-02-01, 51-40-15-02-01. REMOVED FLOOR SUPPORT BEAM, INTERCOSTALS, FRAME WEB AND FLANGE AND INTERNAL STRUCTURE IAW SRM 51-40-15-02-01 AND 51-42-05-0SDR QXEA2012071500693Governor · malfunctionedON TAKEOFF NR 2 PROPELLER NEVER REACHED 1020 RPM. PROPELLER REACHED 950 RPM AND TORQUE AT 92 PERCENT, NR 1 ENGINE RUNS NORMALLY AFTER SELECTION TO PROPELLERS 900 RMP EVERYTHING FUNCTIONED NORMALLY. REPLACED NR 2 OVERSPEED GOVERNOR IAW AMM TASK 61-20-26-000-SDR QXEA2012071400667Light · damagedFLOOR PATH EMERGENCY LIGHT STRIPS AT THE FLIGHT COMPARTMENT DOOR AND IN FRONT OF FORWARD CARGO DOOR ARE DAMAGED. REPLACED STRIPS. RETURNED TO SERVICE.SDR QXEA2012071400685Floor Support · corrodedAFTER REMOVAL OF FRAME 49.5 FOUND CORROSION ON FLOOR SUPPORT STATION AT STR 31S. REMOVED CORRODED STATION, TRANSFERRED HOLES TO NEW PART AND INSTALLED CLAMP BRACKETS IAW SRM 51-42-05-02-01, 51-40-15-02-01 AND 51-40-07-02-01. INSTALLED FLOOR SUPPORT STATION ISDR QXEA2012071400670Battery Pack · inoperativeRT FORWARD EMERGENCY EXIT LOWER FORWARD EXIT LIGHT FOUND TO BE INOPERATIVE DURING THE 10 MINUTE FUNCTIONAL TEST. REPLACED THE NR 2 POWER SUPPLY UNIT IAW AMM 33-51-01-000-801. CHECKED GOOD. RETURNED TO SERVICE.
Back to Pratt & Whitney Canada PW150A