Pratt & Whitney Canada PW150A

Service difficulty reports · 3,094

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE engine_model_key = 'PW150A'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR QXEA2012071400692Propeller · no testNR 1 PROPELLER FAILS ALTERNATE FEATHER CHECK.Jul 14, 2012 · N436QX · Bombdr DHC8402 · Propeller Feathering/ReversingSDR QXEA2012071400731Stringer · corrodedSTRINGER 24S HAS CORROSION AND CORRODED RIVETS BETWEEN STA X216.000 AND X236.000. REMOVED RIVETS, BLENDED CORROSION REF SRM 51-26-00-02-01, 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .030 REF NTM 51-00-04-910-801 PT 1. REMOVED CLEAT REJul 14, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Longeron/StringerSDR QXEA2012071400686Frame · corrodedFRAME X49.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 29S AND 31S. REMOVED 7 RIVETS AND CORROSION IAW RD 8/4-53-2344. FOUND FRAME TO BE CRACKED - REF CONTROL QXEA2012071600701 FOR REPAIR.Jul 14, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR CA120716013Valve · malfunctioned(CAN) ACFT DIVERTED TO AIRPORT DUE ENGINE PROBLEMS. ACFT LANDED SAFELY WITHOUT INCIDENT. FAULT WAS FOR P2.7 VALVE DUAL CHANNEL FAILURE. VALVE REPLACED.Jul 14, 2012 · Bombdr DHC8400 · Engine Bleed Air SystemSDR QXEA2012071300666Light · damagedEMERGENCY LIGHT STRIP BETWEEN F/A SEAT FORWARD AND FLIGHT DECK DOOR DAMAGED. REPLACED LIGHT STRIP. RETURNED TO SERVICE.Jul 13, 2012 · N415QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012071300665Light · damagedFLOOR EMERGENCY PATCH STRIP IN THE COCKPIT ENTRY WORN/DAMAGED. REQUIRES REPLACEMENT. REPLACED LIGHT STRIP IAW 33-51-16-000-801. RETURNED TO SERVICE.Jul 13, 2012 · N412QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012071300668Battery Pack · dischargedEMERGENCY EXIT LIGHTS AT SEAT 19 E/D AND AFT CENTER CEILING LIGHT ARE INOPERATIVE. REPLACED BATTERY PACK. RETURNED TO SERVICE.Jul 13, 2012 · N435QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012071300684Floor Support · corrodedAFT BAGGAGE COMPARTMENT, LT AFT FLOOR SUPPORT WEB HAS AREAS OF CORROSION BETWEEN STA X714.602 AND X783.102. REMOVED FLOOR SUPPORT AND WEB IAW SRM 51-42-05-02-01 AND 51-40-15-02-01. MATCH DRILLED NEW WEB AND SUPPORT IAW SRM 51-40-07-02-01. INSTALLED FLOOR SJul 13, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071300689Generator · failedNR 1 AC GENERATOR WOULD NOT COME ONLINE. FOLLOWED THE EMERGENCY ACTION CHECKLIST. GENERATOR WOULD NOT RESET. REPLACED AC GENERATOR IAW MX 242101, CHECKS GOOD. RETURNED TO SERVICE.Jul 13, 2012 · N433QX · Bombdr DHC8402 · AC Generator-AlternatorSDR QXEA2012071200643Door Frame · scratchedAFT RT SERVICE DOOR AFT DOOR FRAME IS SCRATCHED BELOW SECOND STOP FITTING FROM TOP OF DOOR. SMOOTHED OUT SCRATCH IAW SRM 51-14-00-02-03. MIN THICKNESS REMAINING .060" REF NTM 51-00-04-910-801 PT 1. BLENDED AREA CONFIRMED CRACK FREE REF NTM 51-00-06-910-801 Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, StructureSDR QXEA2012071200650Floor Support · corrodedOTBD FLOOR SUPPORT FOR WARDROBE FLOOR HAS AREA OF CORROSION FROM STA X-15.000 TO X1.00. REMOVED FLOOR SUPPORT BRACKET FOM IAW SRM 51-42-45-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .047 REF NTM 51-00-06-910-801 PT 1. CONFIRMEJul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071200651Frame · corrodedFRAME X196.000 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 31S AND 32S. REMOVED 5 RIVETS AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. FOUND CRACKS IN LOWER FLANGE, CUT AND FABRICATED ANGLE IAW SRM 53-10-15-02-01. FABRICATED ANGLE OUT OJul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012071200652Bulkhead Web · corrodedLT FWD DRAFT BULKHEAD SUPPORT WEB AND ASSOCIATED STRUCTURE AT STA X32.400 HAS AREAS OF CORROSION. THRESHOLD WEB, T ASSY AND ATTACH ANGLE REMOVED FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION ON WEB AND ATTACH ANGLE, FOUND TO BE OUT OF LIMITS IAW SRM 51-21-00Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, BulkheadSDR QXEA2012071200654Skin · corrodedRT WING PANEL LANDING FOR PANEL 623AT HAS PITTING AROUND MULTIPLE HOLES. BLENDED CORROSION IAW RD 8/4-57-441. MINIMUM REMAINING THICKNESS .168", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND Jul 12, 2012 · N408QX · Bombdr DHC8401 · Wing, Plate/SkinSDR QXEA2012071200646Glowstrip · damagedFOUND DAMAGE AT THE SHORT SECTION OF LUMINESCENT TRACK LIGHTING IN THE COCKPIT ENTRY WAY AND THE SECTION THAT RUNS ON THE RT SIDE OF THE AISLE IN FRONT OF THE FWD GALLEY. R & R THE COCKPIT ENTRANCE & RT SIDE IN FRONT OF GALLEY IAW AMM 33-51-16-000/400-801. RJul 12, 2012 · N421QX · Bombdr DHC8402 · Emergency EquipmentSDR QXEA2012071200663Light · defectiveEMERGENCY FLOOR PATH LIGHT AT MAIN CABIN DOOR ENTRY WAY HAS PAINT ON IT 18" SECTION. INSTALLED NEW EMERGENCY LIGHT ASSEMBLY 18" STRIP AT MAIN CABIN DOOR ENTRY WAY IAW AMM TASK 33-51-16-000-801 & 33-51-16-400-801, NO FURTHER DEFECTS NOTED. RETURNED TO SERVICEJul 12, 2012 · N432QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012071200662Light · damagedAISLE EMERGENCY LIGHT BY FWD GALLEY REQUIRES REPLACEMENT. REPLACED AISLE LIGHT TRACK BY FWD GALLEY IAW AMM TASK 33-51-16-000-801 & 33-51-16-400-801. NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.Jul 12, 2012 · N420QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012071200664Light · inoperativeFORWARD 2 EMERGENCY LIGHT STRIPS INOPERATIVE. REMOVED EMERGENCY LIGHT STRIPS AT ENTRY TO COCKPIT AND IN FRONT OF FWD CARGO BAY. IAW AMM TASK 33-51-16-000-801, SUB TASK 33-51-16-020-004. INSTALLED NEW LIGHT IAW AMM TASK 33-51-16-400-801, SUB TASK 33-51-16-420Jul 12, 2012 · N435QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012071200659Light · damagedEMERGENCY FLOOR PATH LIGHT AT STA X32-X71 REQUIRE REPLACEMENT. REPLACED FLOOR PATH STRIPS IAW AMM 33-51-00-900-801. RETURNED TO SERVICE.Jul 12, 2012 · N401QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012071200655Frame · corrodedFRAME X94.800, LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 29P AND 33. REMOVED RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .035 REF NTM 51-00-04-910-801 PT 1. CONFIRMED CRACK FREE CONDITION REF NTM 51Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012071200656Arm · chafedFWD BAGGAGE DOOR HINGE ARM HAS CHAFE DAMAGE ON LOWER SURFACE. SMOOTHED OUT CHAFE DAMAGE IAW SRM 51-14-00-02-03. BLENDED AREA CONFIRMED CRACKFREE REF NTM 51-00-06-910-801 PT 1. MAPPED DAMAGED AREA AND SUBMITTED TO ENGINEERING. FOUND TO BE WITHIN LIMITS IAW Jul 12, 2012 · N408QX · Bombdr DHC8401 · Cargo/Baggage DoorsSDR QXEA2012071200673Skin · corrodedINTERIOR FUSELAGE BELLY SKIN PANEL HAS AREAS OF CORROSION FROM STA X281.000 TO X301.000 BETWEEN STRINGERS 31P AND 32P. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-505. REMAINING THICKNESS .048" REF NTM 51-00-04-910-801 PT 1. Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Plate/SkinSDR QXEA2012071200674Support Angle · corrodedWEB SUPPORT ANGLE UNDER AFT CARGO WEB AT Y-20.000 BETWEEN STATIONS 763.602 AND 783.102 IS CORRODED. REMOVED CORROSION IAW SRM 51-21-00-00-02. MEASURED AND FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00-00-01. MAPPED FOR ENGINEERING. PERFORMED HFEC OF BLENDS NJul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071200675Sill · corrodedLOWER MAIN SILL CORRODED BETWEEN STA 728.102 - 783.102 AT THE AFT BAG DOOR. REMOVED CORROSION IAW SRM 51-21-00-00-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-40-52-00-01. MAPPED FOR ENGINNERING. PERFORMED HFEC IAW NTM 51-00-06-910-801 PT 1. NO CRACKS NOTED. Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071200676Web · corrodedVERTICAL WEB AT STATION 763.00 HAS CORROSION BETWEEN STRINGERS 31P AND 24P. REMOVED CORROSION IAW SRM 51-21-00-00-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-40-15-00-01. MAPPED DAMAGE FOR ENGINEERING. PERFORMED HFEC IAW NTM 51-00-06-910-801 PT 1. FOUND TO BJul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071200677Floor Support · corrodedAFT BAGGAGE COMPARTMENT, LT FWD FLOOR SUPPORT WEB GUSSET HAS AN AREA OF CORROSION AT STA X 698.000. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED CRACK FREE. MIN REMAINING THICKNESS .068 REF 51-00-06-910-801 AND 51-00-04-910-801 PT 1. FOUND WORKED ARJul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071200678Floor Support · corrodedAFT BAGGAGE COMPARTMENT LT FWD FLOOR SUPPORT WEB HAS AREAS OF CORROSION BETWEEN STA X698.000 AND X714.602. REMOVED RIVETS AND REMOVED CORROSION IAW SRM 51-21-00-00-02 AND 51-42-05-02-01. MIN REMAINING THICKNESS .043, CONFIRMED CRACK FREE REF NTM 51-00-04-910Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071200679Support Bracket · corrodedPULLEY SUPPORT BRACKETS AT STA 783.102 STRINGERS 31P AND 29P ARE CORRODED. REMOVED CORROSION IAW 51-21-00-00-02. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-06-910-801, PART 1. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801, PT 1. MAPPED AJul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071200681Stringer · corrodedSTRINGER 24P HAS CORROSION AND CORRODED RIVETS BETWEEN STA X216.000 AND X236.000. CLEANED STRINGER AND REMOVED RIVETS IAW SRM 51-26-00-02-01, 51-42-05-02-01, AND 51-21-00-00-02. BLENDED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING MATERIAL .030 REF NTM 5Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Longeron/StringerSDR QXEA2012071200683Seat Track · corrodedLT NR 5 INBD SEAT TRACK NR 8 HAS AREAS OF WEAR AND CORROSION BETWEEN STA X570.000 AND X670.000. BLENDED CORROSION IAW RD 8/4-53-884. REMAINING THICKNESS FOUND OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACK IAW SRM 51-42-05-02-01, 51-40-15-02-01. MATCHJul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage, Seat/Cargo Attach FittingsSDR QXEA2012071200724Frame · corrodedFRAME X156.0 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 28P AND 30P. REMOVED CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS IS 0.39. CONFIRMED CRACK FREE. MATERIAL REMOVED WITHIN LIMITS. ALODINGED AND PRIMED AREA INSTALLED PROTECTIVE COATING.Jul 12, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012071200697Arm · chafedAFT PAX DOOR MAIN HINGE ARM IS CHAFED ALONG LOWER EDGE. SMOOTHED OUT CHAFED AREA ALONG LOWER EDGEPER SRM 51-14 CONFIRMED BLENDED AREA CRACK FREE USING HFEC REF NTM 51-00-06-910-801, PT 1. REMOVED MAIN HINGE COVER IAW AMM 25-26-21-000-801. MEASURED MAXIMUM Jul 12, 2012 · N408QX · Bombdr DHC8401 · Passenger/Crew DoorsSDR CA120801005O-Ring · failed(CAN) DURING ENGINE NR 2 START, THE GROUND AGENT REQUESTED THE CREW TO IMMEDIATELY SHUTDOWN THE ENGINE. CREW NOTICED SOME SMOKE IN THE COCKPIT BUT NO OTHER INDICATION. CREW DECIDED TO PROCEED TO AN GROUND EMERGENCY EVACUATION INCLUDING THE TRIGGERING OFF 1 Jul 12, 2012 · Bombdr DHC8400 · Hydraulic System, MainSDR QXEA2012071100638Angle · corrodedAFT BAGGAGE COMPARTMENT, RT RE-ENFORCEMENT ANGLE AT BOTTOM OF STEP UP AT STA 783.102 HAS AREAS OF CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02, APPLIED ALODINE IAW SRM 51-21-10-02-01. CONFIRMED BLENDED AREA WAS CRACK FREE REF NTM 51-00-06-910-801 PT Jul 11, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071100639Frame · corrodedFRAME X 32.400 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 30P AND 32P. REMOVED RIVETS IAW SRM 51-42-05-02-0-1. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .039", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 AND 51-00Jul 11, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012071100640Frame · corrodedFRAME X176.000 LOWER FLANGE HAS CORROSION BETWEEN STRINGER 27P AND 28P. REMOVED RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .039", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 AND 51-00-06Jul 11, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012071100641Seat Track · corrodedLEFT INBD SEAT TRACK NR 5 HAS AREAS OF CORROSION BETWEEN STA X-19.400 AND 49.500. BLENDED OUT DAMAGE IAW RD 8/4-53-884. MINIMUM REMAINING THICKNESS IS OUT OF LIMITS IAW RD 8/4-53-884. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLENDJul 11, 2012 · N408QX · Bombdr DHC8401 · Fuselage, Seat/Cargo Attach FittingsSDR QXEA2012071100649Floor Support · corrodedINBD FLOOR SUPPORT FOR WARDROBE FLOOR HAS AREA OF CORROSION FROM STA X-15.000 TO X1.00. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .049 REF NTM 51-00-04-910-801 PT 1. BLENDED AREA CONFIRMED CRACKFREE REF NTM 51-00-06-910-801 PT 1. MAJul 11, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071100653Stringer Clip · corrodedSTRINGER CLIP 24P AT STA 236 IS CORRODED. REMOVED CLIP IAW SRM 51-42-05-02-01. MATCH DRILLED NEW CLIP AND INSTALLED ON FRAME AND STRINGER IAW SRM 51-40-07-02-01 AND 51-42-05-02-01.Jul 11, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Attach FittingsSDR QXEA2012071100661Light · deterioratedCABIN FLOOR EMERGENCY PATH LIGHT STRIP DETERIORATED IN FRONT OF THE MAIN CABIN DOOR, IN FRONT OF THE EMERGENCY EXIT. REPLACED THE DETERIORATED LIGHT STRIPS AS REQUIRED IAW AMM 33-51-16-000-801 AND 33-51-16-400-801. RETURNED TO SERVICE.Jul 11, 2012 · N407QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012071100660Light · deterioratedDURING INSPECTION OF THE FLOOR TRACK EGRESS LIGHTING, FOUND STRIPS TO BE DETERIORATED AT THE FLIGHT COMPARTMENT DOOR AND AT THE FORWARD BAGGAGE DOOR. REPLACED THE EFFECTS STRIPS AS REQUIRED. RETURNED TO SERVICE.Jul 11, 2012 · N403QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012071100658Glowstrip · damagedPHOTOLUMINESCENT STRIP IN BETWEEN THE LAV AND INTERNAL CARGO DOOR IS MORE THAN 80 PERCENT DAMAGED. REPLACED PHOTOLUMINESCENT STRIP IAW AMM TASK 33-51-16-000-801 AND 33-51-16-400-801, NO FURTHER DEFECTS NOTED. RETURNED TO SERVICE.Jul 11, 2012 · N429QX · Bombdr DHC8402 · Emergency EquipmentSDR QXEA2012071100688Floorbeam · corrodedFLOORBEAM X32.400 HAS AREA OF CORROSION OTBD OF LT WIRE BUNDLE TRAY. REMOVED FLOOR SUPPORT FOM IAW SRM 51-42-05-02-01. REMOVED CORRROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .069" REF NTM 51-00-04-910-801 PT 1. BLENDED AREA CONFIRMED CRACK FREJul 11, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Floor BeamSDR QXEA2012071000631Stringer · corrodedSTRINGER 25P HAS CORROSION AND CORRODED RIVETS BETWEEN STA X216.000 AND X281.000. CLEANED AND REMOVED CORRODED RIVETS REF SRM 51-26-00-02-01, 51-42-05-02-01 AND 51-21-00-00-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED INTERIOR ALODINE, PRIMER IAW SRJul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Longeron/StringerSDR QXEA2012071000632Frame · corrodedFRAME X258.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 27P AND 29P. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. CONFIRMED AFFECTED AREA CRACK FREE, MIN REMAINING THICKNESS .039" REF NTM 51-00-06-910-801 AND 51-00-04-910-801 PT 1. MATERIAL LOSS FJul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012071000633Joint · corrodedZEE JOINT 29S AT STA -18.25 IS CORRODED. ZEE JOINT FOUND OUT OF LIMITS IAW SRM 53-10-33-00-01. REMOVED ZEE JOINT IAW SRM 51-42-05-02-01. INSTALLED NEW ZEE JOINT IAW SRM 51-42-05-02-01. APPLIED PRIMER AND TOP COAT IAW SRM 51-25-10-02-01 AND AMM 51-25-31-370Jul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR QXEA2012071000634Skin · corrodedINTERIOR FUSELAGE BELLY SKIN STRAP HAS AREAS OF CORROSION FORWARD OF STA X116.000 BETWEEN STRINGERS 31S AND 32S. REMOVED AND BLENDED CORROSION IAW SRM 51-21-00=00-02. MIN REMAINING THICKNESS ,045" REF NTM 51-000-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE WIJul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, Plate/SkinSDR QXEA2012071000635Frame · corrodedFRAME BS 258.5 FLANGES HAVE CORROSION BETWEEN STRINGER 31 AND 33 PORT. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .039" REF NTM 51-00-04-910-801 PT 1. CONFIRMED CRACK FREE CONDITION OF AFFECTED AREA REF NTM 51-00-06-910-801 PT 1. MAJul 10, 2012 · N408QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012071000637Frame · corrodedFRAME 32.400, LOWER FLANGE HAVE CORROSION BETWEEN STRINGERS 30S AND 29S. REMOVED RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .038", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 AND 51-00-06-910Jul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage Main, FrameSDR QXEA2012071000648Seat Track · corrodedRT INBD SEAT TRACK NR 12 HAS AREAS OF WEAR AND CORROSION BETWEEN STA X102.500 AND X228.500. CLEANED AND BLENDED IAW RD 8/4-53-884. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884. AREAS THAJul 10, 2012 · N408QX · Bombdr DHC8401 · Fuselage, Seat/Cargo Attach Fittings
Back to Pratt & Whitney Canada PW150A