SDR CA120809001Bypass Valve · failed(CAN) LT ENGINE OIL TEMP INDICATED HIGH, THE CREW REDUCED THE ENGINE POWER BUT THE OIL TEMP WAS OVER 107 DEGREES C FOR MORE THAN 10 MIN SO THAT THE PILOT COMMANDED SHUTDOWN THE AFFECTED ENGINE AND DECLARED AN EMERGENCY. THE ACFT MADE ATB TO THE ORIGIN AIRPORTAug 8, 2012 · Bombdr DHC8400 · Engine Oil CoolerSDR CA120813012Oil Cooler · malfunctioned(CAN) DURING CLIMB, THE FLIGHT CREW OBSERVED AN EXCEEDED INDICATION OF HIGH OIL TEMPERATURE ON THE NR 1 ENGINE. THE ENGINE POWER WAS REDUCED TO BRING THE OIL TEMPERATURE DOWN BUT WITHOUT A SUCCESSFUL RESPONSE. THE FLIGHT CREW THEN ELECTED TO SHUTDOWN THE NR Aug 8, 2012 · Bombdr DHC8400 · Engine Oil CoolerSDR QXEA2012080700772Frame · corrodedFRAME X301, FLANGES BETWEEN STRS 29S-33 BUBBLING PAINT PROBABLE CORROSION. REMOVED RIVETS FOM AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .035" CONFIRMED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-Aug 7, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080700781Stanchion · corrodedFRAME X469.5 AND STRINGER 31S STANCHION SHOWS CORROSION. CLEANED AREA AND FOUND CORROSION. REMOVED STANCHION LOCATED AND DRILLED NEW STANCHION FASTENER HOLES IAW SRM 53-20-43-00-01 AND SRM 51-42-05-02-01. INSTALLED STANCHION IAW SRM 51-42-05-02-01. PRIMED Aug 7, 2012 · N405QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR QXEA2012080700796Nut Plate · corrodedAFTER REMOVAL OF LT AND RT WINDSHIELDS FOUND 15 CORRODED NUTPLATES. REMOVED 15 CORRODED NUTPLATES IAW SRM 51-40-07-02-01. INSTALLED NEW NUT PLATES IAW SRM 51-42-05-02-01.Aug 7, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Attach FittingsSDR CA120809013Roller · worn(CAN) FLAP ROLLOR UPPER INBD, FROM LT INBD FLAP CARRIAGE FOUND COMPLETELY WORN OUT.Aug 7, 2012 · Bombdr DHC8400 · Trailing Edge FlapsSDR QXEA2012080600764Frame · corrodedFRAME X236 FLANGES BETWEEN STR 28S - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS AS NESESSARY AND BLENDED CORROSION REF SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .037", CONFIRMED AFFECTED AREA CRAug 6, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080600769Stringer · corrodedSTRINGER 32S BETWEEN FRAMES X564.5 TO X714.6 MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. REMOVED RIVETS FOM IAW SRM 51-42-05-02-0`1. CLEANED AREA AND REMOVED CORROSION IAW SRM 51-26-00-02-01 51-21-00-00-02. INSTALLAug 6, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012080600770Frame · corrodedFRAME X509, FLANGES BETWEEN STRS 28S - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .044" CONFIRMED AFFECTED AREA CRACKAug 6, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080600771Frame · corrodedFRAME X529, FLANGES BETWEEN STRS 29S-30S AND 31S-32S BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-01. MIN REMAINING THICKNESS .043", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1Aug 6, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080600774Stringer · corrodedSTRINGER 27P BETWEEN FRAMES X236 TO X373.1 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED MAY INCLUDE FWD ATTACH FITTING. CLEANED, FOUND TO BE CORRODED RIVETS ONLY. REMOVED 5 RIVETS AS NECESSARY IAW SRM 51-42-05-02-01. INAug 6, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012080600775Stringer · corrodedSTRINGER 26P BETWEEN FRAMES X236 TO X373.1 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. CLEANED, REMOVED 8 RIVETS, CORROSION LIMITED TO FASTENERS IAW SRM 51-26-10-02-01, 51-42-05-02-01. INSTALLED 8 RIVETS IAW SRM 51-42Aug 6, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012080600776Stringer · corrodedSTRINGER 25P BETWEEN FRAMES X236 TO X373.1, MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. CLEANED, REMOVED 7 CORRODED RIVETS IAW SRM 51-26-00-02-01, 51-42-05-02-01. NO OTHER CORROSION NOTED. INSTALLED RIVETS IAW SRM 5Aug 6, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012080500751Seat Track · damagedSEAT TRACK NR 14 MULTIPLE AREAS OF DAMAGE, CORROSION. REMOVED CORROSION IAW RD 8/4-53-884. MEASURED AND FOUND OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACK IAW SRM 51-42-05-02-01 AND 51-40-15-02-01. MATCH DRILLED NEW SEAT TRACK NR 14 AND ALODINED, PRIAug 5, 2012 · N405QX · Bombdr DHC8402 · Fuselage, Seat/Cargo Attach FittingsSDR QXEA2012080500755Frame · corrodedFRAME X236, FLANGES BETWEEN STRS 28P-33 BUBBLING PAINT PROBABLE CORROSION. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .038" REF NTM 51-00-04-910-801 PT 1. CONAug 5, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080500976Frame · corrodedFRAME X258, FLANGES BETWEEN STRS 25S-26S AND 28S - 32S, BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS PAINT, PRIMER AND CORROSIN IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. NO OTHER CORROSION OR DEFECTS NOTED. MIN REMAININAug 5, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080500977Stringer · corrodedSTRINGER 33 BETWEEN FRAMES X564.5 TO X714.6 AND SKIN ADJACENT TO STRINGER, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED MAY INCLUDE FWD ATTACH FITTING. CLEANED AREA IAW SRM 51-26-04-02-01, CORROSION FOUND LIMITED TO FAug 5, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Longeron/StringerSDR QXEA2012080400757Frame · corrodedFRAME X301, FLANGES BETWEEN STR 29P - 33 BUBBLING PAINT PROBABLE CORROSION. REMOVED RIVETS IAW SRM 51-42-05-02-01, REMOVED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .037 CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-0Aug 4, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080400765Frame · corrodedFRAME X439, FLANGES BETWEEN STR 28S - 33 BUBBLING PAINT PROBABLE CORROSION. REMOVED RIVETS AS NECESSARY AND BLENDED CORROSION REF RD 8/4-53-2344. MIN REMAINING THICKNESS .060", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-91Aug 4, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080400768Frame · corrodedFRAME X439.5, FLANGES BETWEEN STRS 31P - 33, BUBBLING PAINT PROBABLE CORROSION. CLEANED AREA, REMOVED RIVETS AND BLENDED AREA IAW RD 8/4-53-2344. REMAINING THICKNESS NOTED .061", CONFIRMED AREA CRACK FREE REF 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. Aug 4, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080300752Flange · corrodedFRAME 703.6, FLANGE AT STR 24S HAS CORROSION. REMOVED HI LITE AND BLENDED CORROSION IAW SRM 51-40-15-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .046", CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOAug 3, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080300756Frame · corrodedFRAME X281, FLANGES BETWEEN STRS 28S -33 AND ABOVE STR 24S BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. BLENDED AREA IAW RD 8/4-53-2344. CLEANED AND REMOVED RIVETS IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .037" CONFIRMEDAug 3, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080300758Frame · corrodedFRAME X449.5 FLANGES BETWEEN STR 31P - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .060", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51Aug 3, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080300759Frame · corrodedFRAME X584 FLANGES BETWEEN STR 30P - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .046", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 5Aug 3, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080300760Frame · corrodedFRAME X156, FLANGES BETWEEN STR 28S - 29S BUBBLING PAINT PROBABLE CORROSION. REMOVED RIVETS IAW SRM 51-42-05-02-01 AND CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .038" REF NTM 51-00-04-910-801-PT 1. CONFIRMED AFFECTED AREA CRACK FREE REF NTM Aug 3, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080300763Frame · corrodedFRAME X624, FLANGES BETWEEN STR 29S - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED IAW SRM 51-26-00-02-01. REMOVED RIVETS AS NESESSARY AND BLENDED CORROSION REF RD 8/4-53-2344. MIN REMAINING THICKNESS .046", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00Aug 3, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080300767Frame · corrodedFRAME X489.5 FLANGES BETWEEN STRS 29S - 33 BUBBLING PAINT PROBABLE CORROSION. CLEANED AREA, REMOVED FOUR RIVETS AND BLENDED CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS NOTED .046", CONFIRMED AREA CRACK FREE REF 51-00-04-910-801 PT 1 AND 51-00-06-910-80Aug 3, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080200747Light · looseF/A ADVISED ENROUTE THAT EMERGENCY LIGHT LOOSE AT ROW 1 AB. APPLIED TAPE TO FWD EMERGENCY LIGHT. OK FOR CONTINUED SERVICE.Aug 2, 2012 · N420QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012080200748Bulb · inoperativeSEVERAL CABIN CEILING ADVISORY LIGHT BULBS INOPERATIVE. RELAMPED.Aug 2, 2012 · N400QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012080200750Lamp · inoperativeCENTER AND FORWARD CABIN OVERHEAD INFORMATION SIGNS HAS INOPERATIVE LAMPS. REPLACED LAMPS.Aug 2, 2012 · N434MK · Bombdr DHC8402 · Emergency LightingSDR QXEA2012080200753Seat Track · damagedSEAT TRACK NR 13 MULTIPLE AREAS OF DAMAGE CORROSION, MISSING RIVET BETWEEN FRAMES X321 - X341 . CLEANED AREA AT SEAT TRACK NR 13 IAW SRM 51-26-00-02-01. BLENDED OUT CORROSION IAW SRM 51-18-00-00-01. FOUND OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACKAug 2, 2012 · N405QX · Bombdr DHC8402 · Fuselage, Seat/Cargo Attach FittingsSDR QXEA2012080100746Warning Light · illuminatedNR 1 RUDDER HYDRAULIC CAUTION LIGHT ILLUMINATED AFTER TAKEOFF. RETURNED TO FIELD. LANDED UNEVENTFUL. R & R NR 1 RUDDER SHUTOFF VALVE AS A PRECAUTION. INSTALLED IAW AMM TASK 27-21-28-400-801. REMOVED IAW AMM 27-21-28-000-801. PERFORMED OPS TEST IAW TASK 27-Aug 1, 2012 · N411QX · Bombdr DHC8401 · Hydraulic System, MainSDR QXEA2012080100749Bulb · inoperativeSEVERAL CENTER AND FORWARD OVERHEAD SIGN BULBS ARE INOPERATIVE. RELAMPED.Aug 1, 2012 · N439QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012080100744Frame · damagedFRAME BS 714, FLANGES BETWEEN STR 31P-32P BUBBLING PAINT PROBABLE CORROSION. CLEANED FRAME IAW SRM 51-26-00-02-01. REMOVED 1 RIVET AND CORROSION IAW SRM 51-40-07-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .037" CONFIRMED AREA CRACK FREE REF 51-00-04-9Aug 1, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, FrameSDR QXEA2012080100754Access Panel · damagedRT WING FUEL ACCESS PANEL LANDING AT APPROX STA YW140.000 HAS DEEP BLENDS AND BARE METAL AROUND 2 BOLT HOLES. MEASURED DEEP BLENDS AND FOUND OUT OF LIMITS IAW RD 8/4-57-441. MIN REMAINING THICKNESS .155" CONFIRMED CRACK FREE REF NTM 51-00-04-910-801 PT 1 ANDAug 1, 2012 · N405QX · Bombdr DHC8402 · Wing, Plate/SkinSDR QXEA2012073100761Stringer Clip · corrodedSTRINGER CLIP, STRINGER 24P AT FRAME X564.5 BUBBLING PAINT PROBABLE CORROSION. STRINGER CLIP HEAVILY CORRODED, REMOVED STRINGER CLIP IAW SRM 51-40-07-02-01. MATCH DRILL NEW STR CLIP IAW SRM 51-40-07-02-01. INSTALLED CLIP IAW SRM 51-42-05-02-01. ALODINED ANJul 31, 2012 · N405QX · Bombdr DHC8402 · Fuselage Main, Attach FittingsSDR QXEA2012073000745Line · leakingNR 2 HYD QUANTITY LOST, DROPPED TO ZERO, BEGAN WITH NR 2 HYD FLUID QUANTITY LOW, TRANSITIONED TO NR 2 ENG HYD PUMP CAUTION CHECKLIST, NR 2 ENG RAN FOR 25-30 MINUTES AFTER TOTAL LOSS OF FLUID, ALTERNATE GEAR EXTENSION ACCOMPLISHED SUCCESSFULLY. LANDING UNEVENTFJul 30, 2012 · N406QX · Bombdr DHC8401 · Hydraulic System, MainSDR QXEA2012073000766Intercostal · crackedCRACKED INTERCOSTAL ON LT NACELLE, VIEWED THRU BOAT TAIL ACCESS INTERCOSTAL IS FOR FINGERNAIL MOUNTING. REMOVED CRACKED INTERCOSTAL ON LT NACELLE IAW SRM 51-42-05-02-01. RECEIVED NEW INTERCOSTAL AND MATCH DRILLED TO EXISTING STRUCTURE IAW SRM 51-40-07-02-01.Jul 30, 2012 · N405QX · Bombdr DHC8402 · Nacelle/Pylon Miscellaneous StructureSDR CA120731002Control Cable · frayed(CAN) AFTER A SCHEDULED INSPECTION, TWO PRIMARY AILERON CABLES WERE FOUND FRAYED OUT OF LIMIT. INVESTIGATION ON THE REMAINING OF THE FLEET WAS DONE AND THE SAME PROBLEM WAS FOUND ON THE ACFT. LT 82742407-001 AND RT 82742409-001, PRIMARY AILERON CABLES HAD TO Jul 30, 2012 · Bombdr DHC8400 · Aileron Control SystemSDR CA120731003Control Cable · frayed(CAN) AFTER A SCHEDULED INSPECTION, 2 PRIMARY AILERON CABLES WERE FOUND FRAYED OUT OF LIMIT. INVESTIGATION ON THE REMAINING OF THE FLEET WAS DONE AND THE SAME PROBLEM WAS FOUND ON THE ACFT. LT, 82742407-001 AND RT 82742409-001, PRIMARY AILERON CABLES HAD TO BEJul 30, 2012 · Bombdr DHC8400 · Aileron Control SystemSDR QXEA2012072900742Floor Support · corrodedFRAME X32.4 CENTERLINE FLOORBOARD ATTACH AND STRUCTURE LIFTING PAINT/PROBABLE CORROSION. REMOVED FLOORBOARD ATTACH IAW SRM 51-42-05-02-01. CORROSION LIMITED TO FLOORBOARD . MATCH DRILLED IAW SRM 51-40-07-02-01. INSTALLED FLOORBOARD ATTACH IAW SRM 51-42-05-Jul 29, 2012 · N408QX · Bombdr DHC8401 · Fuselage Miscellaneous StructureSDR CA120801001Valve · leaking(CAN) SHORTLY BEFORE DEPARTURE, RAMP CREW REQUESTED MAINTENANCE TO INSPECT A MAIN WHEEL TIRE. LOCAL MAINTENANCE ARRIVED AND CONFIRMED FLAT TIRE ON THE NR 1 AND NR 3 MAIN WHEEL ASSEMBLIES. INSPECTION OF THE MAIN WHEEL ASSEMBLIES REVEALED THAT 1 OF THE TIRE INFJul 29, 2012 · Bombdr DHC8400 · TireSDR QXEA2012072800736Light · damagedCABIN FLOOR PATH LIGHTING AT ROWS 1-2 IS DISCOLORED FOR MORE THEN 50 PERCENT OF THE WIDTH. REPLACED EFFECTED FLOOR PATH LIGHTING STRIPS AS REQUIRED.Jul 28, 2012 · N403QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012072800737Light · damagedEMERGENCY FLOOR PATH LIGHTING STRIP DISCOLORED MORE THAN 50 PERCENT OF THE WIDTH . CLEAN SEGMENTS AS REQUIRED AND REPLACED AFFECTED SEGMENTS THAT WERE OUT OF LIMITS.Jul 28, 2012 · N418QX · Bombdr DHC8402 · Emergency LightingSDR QXEA2012072800741Connector · brokenF/A REPORTS BURNED RUBBER ODOR IN THE AFT GALLEY, DETERMINED TO BE AFT CARGO BAY LIGHTS, DEACTIVATED. INSPECTED AND FOUND FORWARD LIGHT TO HAVE A BROKEN POSITIVE CONNECTOR. R & R LIGHT ASSY IAW AMM TASKS 33-31-01-000-801/400/801. OPS CHECKED GOOD. NO ODORSJul 28, 2012 · N408QX · Bombdr DHC8401 · Light System WiringSDR CA120730001Control Cable · frayed(CAN) WHEN DOING A SCHEDULED INSPECTION, 2 AILERON CONTROL CABLES WERE FOUND FRAYED OUT OF LIMIT ON 1 ACFT. INSPECTION IS CURRENTLY BEING DONE ON THE REMAINING OF THE FLEET, AND 2 OTHER ACFT SO FAR WERE IDENTIFIED WITH OUT OF LIMIT FRAYED CABLES.Jul 28, 2012 · Bombdr DHC8400 · Aileron Control SystemSDR QXEA2012072700733Seat Track · corrodedSEAT TRACK NR 15 MULTIPLE AREAS OF DAMAGE/CORROSION. REMOVED CORROSION IAW RD 8/4-53-884. FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884. REMOVED SEAT TRACK NR 15 IAW SRM 51-42-05-02-01. MATCH DRILLED NEW SEAT TRACK NR 15 IAW SRM 51-40-07-02-01. ALODINED HOLJul 27, 2012 · N408QX · Bombdr DHC8401 · Fuselage, Seat/Cargo Attach FittingsSDR CA120802013Indicator · malfunctioned(CAN) IT WAS REPORTED THAT THE ENGINE WAS NOT PRODUCING MORE THAN 43 PERCENT OF TORQUE LEADING TO AN ABORTED TAKEOFF. SAME ACFT HAD ANOTHER ABORTED TAKEOFF THE DAY BEFORE DUE TO TORQUE NOT GOING OVER 60 PERCENT. TROUBLESHOOTING ONGOING.Jul 27, 2012 · Cndair CL6002B19 · Engine BMEP/Torque IndicatingSDR QXEA2012072600743Light · no testEMERGENCY LIGHT SYSTEM IN THE CABIN FAILS TEST. OPENJul 26, 2012 · N408QX · Bombdr DHC8401 · Emergency LightingSDR QXEA2012072500727Attach Bracket · crackedLEFT NR 3 HYD SYS ELEVATOR PCU AIR FRAME STRUCTURE ATTACH BRACKET IS BROKEN (CRACKED). ACFT CURRENTLY DOWN FOR REPAIRS.Jul 25, 2012 · N416QX · Bombdr DHC8401 · Wing, Attach Fittings
Back to Pratt & Whitney Canada PW150A