Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2010122200928Floor Support · damagedSEA- "L" SUPPORT BRACKET AT STA X-39.000 & Z 100.032 (FORWARD SUPPORT OF FLOOR PANEL 133AZ) HAS APPROX 3.5625" PIECE BROKEN OFF BETWEEN THE TWO INBOARD SEAT RAILS. FERRIED TO PDX FOR REPAIR. REMOVED AND REPLACED KICK PANEL PN 85311097-105 REF SRM 51-42-45. RESDR QXEA2010122100907Frame · corrodedC4 CHECK - INTERNAL FUSELAGE UNDERFLOOR AT STA 19.400 FWD SIDE OF FRAME, FRAME FLANGE HAS SURFACE CORROSION BETWEEN STR 32R TO 31R AND 31R TO 30R. REMOVED CORROSION IAW RD 8/4-53-2344. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. MIN MATERIAL THSDR QXEA2010122100912Frame · corrodedC4 CHECK - INTERNAL FUSELAGE FRAME TO SKIN FLANGE AT STA 71.200, STR 31R TO 30R HAS SURFACE CORROSION. REMOVED CORROSION, MIN MATERIAL REMAINING .037" REF NTM 51-00-02-250-801. COMPLIED WITH RD 8/4-53-2344.SDR QXEA2010122100915Doubler · corrodedC4 CHECK - LAV VENT AFT OF FR 19.400 BY STR 33 INTERNAL SKIN DOUBLER IS CORRODED. REMOVED CORROSION IAW SRM 51-21-00. MIN THICKNESS REMAINING .024" REF NTM 51-00-02-250-801 FOUND OUT OF LIMITS. FABRICATED AND MATCH DRILLED NEW DOUBLER IAW SRM 51-40-07. ALOSDR QXEA2010122100917Skin · corrodedC5 CHECK - BELLY ANTENNA BETWEEN FR 236.000 AND 258.500 IS CORRODED. BLENDED CORROSION FROM SKIN REF SRM 51-21-00-00-01. MIN THICKNESS .05" REF NTM 51-00-02-250-801. CONFIRMED AREA IS CRACKFREE CONDITION. REMAINING THICKNESS FOUND TO BE OUT OF LIMITS IAW SSDR QXEA2010122100918Skin · corrodedC4 CHECK - LAV DRAIN MAST FOUND EXTERNAL DOUBLER HAS CORROSION. REMOVED LAV DRAIN MAST EXTERNAL DOUBLER IAW SRM 51-42-05. FABRICATED NEW EXTERNAL DOUBLER FROM 2024 T3 .063" IAW SRM 51-42-05. ALODINED AND PRIMED PART IAW SRM 51-21-10 AND 51-25-10. INSTALLEDSDR QXEA2010122100913Frame · corrodedC4 CHECK - FR 18.250 LOWER FLANGE BETWEEN STR 32R AND 31R IS CORRODED. CORROSION REMOVED IAW SRM 51-21-00-00-02. MIN THICKNESS REMAINING .023" REF NTM 51-00-02-250-801. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. COMPLIED WITH RD 8/4-53-3446.SDR QXEA2010122100914Doubler · corrodedC4 CHECK - INTERNAL ANTENNA DOUBLER BETWEEN FR 19.400 AND 1.000, STR 33 AND 32R IS CORRODED. REMOVED CORROSION IAW SRM 51-21-00. MIN THICKNESS REMAINING .028" REF NTM 51-00-02-250-801. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801 DOUBLER FOUND OUTSDR QXEA2010122100925Display · failed"PFD 1 MON FAIL" MESSAGE ON ED. C/A FD HAS MULTIPLE FAILURES OF ALL INSTRUMENTS (RED X'S, ATT FAIL, IAS FAIL, ALT FAIL, HDG FAIL). RETURNED TO FIELD, LANDING UNEVENTFUL. INSPECTED GROUNDS FOR NR1 PFD AND NR1 ICP. ALL GROUNDS WERE SECURE. REPLACED NR1 PFD IASDR QXEA2010122000922Hinge · dirtyLANDING GEAR ALTERNATE EXTENSION DOOR ON FLOOR IS VERY HARD TO OPEN. CLEANED AND LUBED ALTERNATE EXTENSION DOOR HINGE AS REQUIRED. DOOR OPS CHECKED GOOD. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010122000895Threshold · corrodedC-CHECK. CARGO DOOR THRESHOLD HAS AREAS OF CORROSION. BLENDED CORROSION IAW SRM 51-21-00-02. REMAINING THICKNESS 0.52" OUTSIDE OF LIMITS. FABRICATED AND INSTALLED NEW DOOR THRESHOLD IAW T/C 6-53-958.SDR QXEA2010122000898Stringer Clip · corrodedFRAME 49.500 TO STR 33, CLIP IS CORRODED. REMOVED CLIP FOR ACCESS TO AREA. REMOVED CORROSION IAW SRM 51-21-00, REV 7. REMOVED MATERIAL OUT OF LIMITS. FABRICATED FRAME 49.500 TO STR 33 CLIP OUT OF .040 7078-T6 IAW TASK CARD 6-53-960. NDT DETERMINED TO BE CRACSDR QXEA2010122000901Skin · damagedC-CHECK, EXTERNAL FUSELAGE RT SIDE HAS EVIDENCE OF A LIGHTNING STRIKE. MELT MARKS ON THE SKIN TO RIVETS FROM STR 9R STA 30.000 TO 301.000. BLENDED BURN MARKS IAW SRM 51-14-00-02-03. FOUND TO BE WITHIN LIMITS. TREATED AND PRIMED REPAIRED AREAS. NDT CONFIRMSDR QXEA2010122000908Seat Track · corrodedC-CHECK, INTERNAL FUSELAGE RT CTR SEAT TRACK HAVE CORROSION FROM STA 18.25 TO STA 47.9. SEAT TRACK WAS FOUND TO BE OUT OF LIMITS (NR10 AND NR11). R & R SEAT TRACKS IAW SRM 51-40-15 AND 51-40-07. INSTALLED TOP COAT ON SEAT TRACKS.SDR QXEA2010122000916Frame · corrodedC-CHECK, FRAME 196.000 LOWER FLANGE IS CORRODED BETWEEN STRINGERS 32L AND 33. REMOVED FOR ACCESS, THE RADIO ALTIMETER TRANSCEIVER. REMOVED RIVETS TO GAIN ACCESS. FLANGES ON FRAME BETWEEN 32L AND 33 FOUND TO BE OUT OF LIMITS. BLENDED CORROSION ON FRAME FLANGE 1SDR QXEA2010122000919Frame · corrodedWHILE WORKING CORROSION ON FRAME 18.25 LOWER FLANGE, FOUND CORROSION ON THE VERTICAL WEB JUST OTBD OF STRINGER 31R. RECEIVED NEW FRAME SECTION AND INSTALLED IAW TASK CARD AND RD 8/4-53-3446.SDR QXEA2010122000923Unknown · unknownON PREFLIGHT NR 2 AND NR 1 PROP NOT FEATHERED. GROUND RAN ACFT, CYCLED PROPS SEVERAL TIMES, NO DEFECTS NOTED, ACFT OK FOR CONTINUED SERVICE. NO PARTS REPLACED.SDR QXEA2010122000924Controller · failedFLIGHT WITH A DIVERSION. CAPTAINS WINDSHIELD HEAT UNIT EMITTING SMOKE. TURNED OFF WINDSHIELD HEAT AND SMOKE STOPPED. LANDING UNEVENTFUL. VERIFIED INTEGRITY OF AIRFRAME WIRING ASSOCIATED WITH CAPTAINS WINDSHIELD HEATING SYS. CHECK OK. REPLACED CAPT'S WINDSHIELSDR QXEA2010122000896Frame · corrodedC-CHECK. FRAME 18.250 LOWER FLANGE BETWEEN STRINGERS 31L AND 32L IS CORRODED. REMOVED RIVETS TO GAIN ACCESS TO AREA. REMOVED CORROSION IAW SRM 51-21-00-00-02. CORROSION ALSO FOUND BETWEEN STRINGERS 32L AND 33 AND WAS REMOVED AS WELL IAW R/D 8/4-53-2344. MATESDR QXEA2010122000897Frame · corrodedC-CHECK. FRAME 49.500 TOP FLANGE IS CORRODED BY THE STANTION AT STR 31R. REMOVED TCAS PROCESSOR FOR ACCESS TO THE AREA. REMOVED STANTION FOR ACCESS. REMOVED CORROSION FROM TOP FLANGE AND STA MATING SURFACE OF FRAME IAW SRM 51-21-00-00-02 REV 7. REMOVED MATSDR QXEA2010122000899Frame · corrodedC-CHECK, FRAME 49.500 LOWER FLANGES BETWEEN STRINGERS 33 AND 31R ARE CORRODED. REMOVED TRANSPONDER RECEIVERS TO GAIN ACCESS AND REMOVED BRACKET. REMOVED CORROSION FROM AREA IAW SRM 51-21-00, REV 7. REMOVED MATERIAL OUT OF LIMITS. CUT OFF LOWER DAMAGED FLANGSDR QXEA2010122000900Frame Splice · corrodedC-CHECK, FRAME X94.800 SPLICE PLATE AT BL 0 CORRODED. FABRICATED NEW REPAIR FRAME SPLICE IAW STEP 7 OF MFG RD 8/4-53-3459. NDT CONFIRMED CRACK FREE. PRIMED AND PAINTED AND INSTALLED REPAIR TO THE ACFT.SDR QXEA2010122000902Skin · crackedC-CHECK. RT OTBD FLAP UPPER SURFACE BETWEEN TRACKS 4 AND 5 HAS 3 DENTS. NO CRACKS FOUND AND NO DISBOND FOUND. APPLIED YELLOW DOTS TO DENTS IAW GPM 10.11.4.SDR QXEA2010122000910Frame · corrodedC-CHECK. FRAME 94.800 LOWER FLANGES BETWEEN STRINGERS 32L AND 31R ARE CORRODED. REMOVED MLS AND ELECTRONIC TRAYS FOR ACCESS. FABRICATED 3 FRAME REPAIR FLANGES OUT OF 2024-T3 TREATED AND PRIMED. NDT CONFIRMED CRACK FREE. INSTALLED REPAIR FLANGES AND STRINGERSDR QXEA2010122000920Skin · dentedC-CHECK, RT HORIZONTAL STABILIZER UPPER SURFACE HAS 2 SMALL DENTS 12 INCHES LONG FROM THE T/E AND 3 FT OUT FROM THE VERTICAL STAB. REMOVED PAINT TO INSPECT AREA. FIRST DENT .017" AND SECOND DENT .005". FWD DENT FOUND TO BE CRACKED. REMOVED PANEL 342BB FOR FOSDR QXEA2010121400890Floor Panel · corrodedC5 CHECK - AFT CARGO COMPARTMENT FLOOR PANEL 144HZ IS CORRODED. REMOVED CORROSION IAW SRM 51-21-00-00-02, MEASURED A NOMINAL THICKNESS OF .042" AND A MIN REMAINING THICKNESS OF .036" FOUND PANEL TO BE OUT OF LIMITS IAW SRM 51-14-00-00-01. MATCH DRILLED HOLESSDR QXEA2010121400891Floor Panel · corrodedC5 CHECK - AFT CARGO COMPARTMENT FLOOR PANEL 144GH IS CORRODED. REMOVED CORROSION IAW SRM 51-21-00-00-02, MEASURED A NOMINAL THICKNESS OF .042" AND A MIN REMAINING THICKNESS OF .032" FOUND PANEL TO BE OUT OF LIMITS IAW SRM 51-14-00-00-01. MATCH DRILLED HOLESSDR QXEA2010121600861Frame · corrodedREMOVED CORROSION FROM FRAME 32.400 IAW SRM 51-21-00, MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-20-15. REMOVED FRAME PIECE STR 33-28R IAW SRM 51-42-05 AND 51-41-00. INSTALLED NEW FRAME SEGMENT IAW SRM 51-42-05. APPLIED PAINT AND CPC AS NEEDED IAW ASDR QXEA2010121600892Door Frame · corrodedC5 CHECK - CORROSION ON THE AFT DOOR FRAME AND FLANGE OF ACCESS DOOR 311AB. REMOVED CORROSION IAW SRM 51-21-00-00-02 AND RD 8/4-53-2344. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. COMPLIED WITH RD 8/4-55-592.SDR QXEA2010121300872Frame · corrodedC5 CHECK - FR 176.000 LOWER FLANGES ARE CORRODED BETWEEN STR 32L AND 31R. REMOVED CORROSION FR 176 LOWER FLANGE, FOUND OUT OF LIMITS, IAW RD 8/4-53-2344. TRIMMED LOWER FRAME FLANGES AT 32L-33 AND 32R-33 IAW RD 8/4-53-017. BLENDED LOWER FRAME FLANGE AT 31R IAWSDR 3LYA20101215Clamp · brokenACFT RETURNED TO DEPARTURE DUE TO THE NR2 ENGINE GENERATOR FAILURE AND LOSS OF OIL PRESSURE. CREW HAD TO SHUTDOWN AND FEATHER THE NR2 ENGINE. THE ACFT LANDED SAFELY AND WAS TOWED BACK TO THE GATE. MX DISCOVERED THAT THE NR2 ENGINE AC GENERATOR V-BAND CLAMP WASSDR NSVA2010222Engine · oil consumptionAIRCRAFT WAS JUST RELEASED FROM HOLDING OVER HELON INTERSECTION WHEN F/O NOTICED SMOKE IN THE VICINITY OF HIS OVERHEAD LIGHT. CAPTAIN ALSO SAW THE SMOKE AND NOTICED ACRID SMELL. LAV SMOKE DETECTOR ACTIVATED. CAPTAIN CALLED F/A AND SHE REPORTED THAT THERE WASSDR QXEA2010121300886Frame · corrodedC5 CHECK - UPON REMOVAL OF STA 49.500 STR 33 CLIP FOUND FRAME AT STA 49.500 STR 33-32R FWD SIDE TO BE CORRODED. REMOVED CORROSION IAW SRM 51-21-00. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-3453. APPLIED ALODINE AND PRIMER IAW SRM 51-21-10 AND 51-25-10. APPSDR QXEA2010121600894Aileron Sys · out of rigLARGE AMOUNT OF LT WING DOWN AILERON TRIM TO MAINTAIN LEVEL FLIGHT, ALSO NOTED CONTROLS TURNED HARDER TO THE RT THAN THE LT. MX WAS UNABLE TO PIN RT TERMINAL QUADRANT WITHOUT PUSHING DOWN ON RT AILERON. FOUND RT AILERON SPLITTER TO AILERON TERMINAL QUADRANT SDR QXEA2010121300871Frame · corrodedC5 CHECK - FOUND CORROSION ON FR 156 LOWER FLANGE STR 33-32R. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. CONFIRMED REPAIR AREA IS CRACK FREE REF NTM 51-00-01-250-801. FABRICATED AND INSTALLED REPAIR IAW RD 8/4-53-017 AND SRM 51-21-10 AND 51-25-10. APPLIED SDR QXEA2010121300881Frame · corrodedC5 CHECK - FR 18.250 UPPER FLANGE IS CORRODED FROM STR 33 TO 32R. REMOVED CORROSION IAW SRM 51-21-00-00-02, FOUND TO BE WITHIN LIMITS IAW SRM 51-14-00-02-03.SDR QXEA2010121300882Frame · corrodedC5 CHECK - FR 236.000 LOWER FLANGES FROM STR 32L TO 31R ARE CORRODED. REMOVED CORROSION SRM 51-21-00-00-02. MIN REMAINING THICKNESS .033" REF NTM 51-00-02-250-801, CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. LOSS FOUND OUT OF LIMITS IAW RD 8/4-SDR QXEA2010121300884Web · corrodedC5 CHECK - WHILE WORKING CORROSION ON FR 18.25 LOWER FLANGE, FOUND CORROSION ON VERTICAL WEB JUST OTBD OF STR 31R. REMOVED CORROSION IAW SRM 51-14-00. FOUND TO BE WITHIN LIMITS IAW SRM 51-14-00 STEP 5C. ALODINE AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-SDR QXEA2010121300885Frame · corrodedC5 CHECK - AFT SIDE OF FRAME AT STA 18.250 IS CORRODED AT STR SPLICE ATTACH POINT STR 31R. R & R FRAME.SDR QXEA2010121500893Pcu · malfunctionedDURING TAXI IN, AFTER LANDING, NR 2 ENGINE TOURQUE WOULD NOT GO BELOW 9 PERCENT THE NR 1 ENGINE TOURQUE WAS AT 1 PERCENT. THE GROUND RANGE LIGHT ON THE NR 2 PROP WAS NOT ILLUMINATED ON THE GROUND. R & R NR 2 ENGINE PCU IAW AMM 61-20-11-000-801 AND 61-20-11-4SDR QXEA2010121300873Sill · corrodedC5 CHECK - AFT BAGGAGE COMPARTMENT OUTER DOOR SILL HAS CORROSION IN MULTIPLE AREAS ON INBD SIDE. REMOVED CORRODED DOOR SILL IAW SRM 51-21-00-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00-01. REMOVED DOOR SILL AND INSTALLED NEW SILL IAW SRM 51-42-05.SDR QXEA2010121300874Fitting · corrodedC5 CHECK - AFT CABIN FLOOR FITTING AT X697 BETWEEN SEAT TRACKS 15 AND 23 ARE CORRODED. REMOVED CORROSION IAW SRM 51-21-00. FOUND TO BE OUT OF LIMITS. REMOVED FITTING IAW SRM 51-42-05-02-01, INSTALLED NEW FITTING IAW SRM 51-42-02-01.SDR QXEA2010121300875Stringer · corrodedC5 CHECK -STR 32R IS CORRODED ON THE INBD SIDE APPROX 16" AFT OF THE PILOTS BULKHEAD. REMOVED CORROSION IAW SRM 51-21-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-20-03. COMPLIED WITH RD 8/4-53-3444, SRM 51-21-10-02-01 AND 51-25-10-02-01.SDR QXEA2010121300878Skin · corrodedC5 CHECK - FUSELAGE SKIN CORROSION UNDER FRAME NR3 BOTTOM STA X882.703. REMOVED LIGHT CORROSION IAW SRM 51-21-00. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. MIN REMAINING THICKNESS OF SKIN .060 REF NTM 51-00-02-250-801. MATERIAL LOSS FOUND WISDR QXEA2010121300879Seat Track · corrodedC5 CHECK - SEAT TRACK 9 HAS CORROSION AROUND THE FASTENERS BY STA X747.602. REMOVED FASTENERS AND BLENDED CORROSION IAW SRM 51-40-15. COMPLIED WITH RD 8/4-53-884, RD 8/4-53-3439 AND SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01.SDR QXEA2010121300880Stringer · corrodedC5 CHECK - STR 32R IS CORRODED ON THE INBD SIDE APPROX 16" AFT OF THE PILOTS BULKHEAD. REMOVED CORROSION IAW SRM 51-21-00. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. MIN THICKNESS REMAINING .036" REF NTM 51-00-02-250-801. LOSS FOUND TO BE OUTSDR QXEA2010121000865Seat Track · corrodedC5 CHECK - SEAT TRACK 24 HAS AREAS OF CORROSION. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884. REMOVED AND INSTALLED NEW TRACK IAW SRM 51-42-05 AND 51-42-45.SDR QXEA2010121000866Web · corrodedC5 CHECK - AFT BAGGAGE COMPARTMENT UPPER FLOOR WEB HAS WIDESPREAD CORROSION BETWEEN STA 714.6 AND 789.1. REMOVED CORROSION IAW SRM 51-21-00-00-02. MEASURED A NOMINAL THICKNESS OF .050" AND REMAINING THICKNESS OF .035" FOUND TO BE OUT OF LIMITS IAW SRM 51-14-SDR QXEA2010121000867Floor Panel · corrodedC5 CHECK - AFT CARGO COMPARTMENT FLOOR PANEL 144FZ IS CORRODED. REMOVED PANEL 144FZ IAW SRM 51-41-05-00-01. REMOVED CORROSION IAW SRM 51-21-00-00-02, MEASURED DEPTH OF DAMAGE REMOVAL AT .004" MEASURED NOMINAL THICKNESS OF .042" FOUND PANEL WITHIN LIMITS IAW SDR QXEA2010121000868Frame · corrodedC5 CHECK - CORROSION ON FRAME IN TAIL COMPARTMENT JUST FWD OF DOOR 311AB. REMOVED FRAME NR3 BOTTOM AT X882.703 AND LT AND RT CAP SPLICE REF SRM 53-50-15, FIG 1, PG 14, BY DRILLING OUT RIVETS IAW SRM 51-42-05. LOCATED AND DRILLED FASTENER HOLES IN NEW NR3 BOT
Back to Pratt & Whitney Canada PW150A