Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2011012600083Governor · malfunctionedWHEN BRINGING THE PROPS OUT OF FEATHER AFTER START, NR1 LAGGED BEHIND NR2 COMING OUT OF FEATHER. REPLACED FEATHER PUMP W3ITH NO HELP. R & R NR1 ENG OVERSPEED GOVERNOR IAW AMM 61-20-26-400-801. NO LEAKS NOTED, OPS CK NORMAL. RETURNED TO SERVICE.SDR QXEA2011011900041Frame · corrodedC5 CHECK - FUSELAGE FRAME X258.500 LOWER FLANGE BETWEEN STRINGERS 31S & 32S HAS CORROSION. REMOVED CORROSION FROM FLANGE IAW RD 8/4-53-2344. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. APPLIED ALODINE AND PRIMER TO FRAME AS REQUIRED IAW RD 8SDR QXEA2011011900052Frame · corrodedC5 CHECK - FUSELAGE FRAME X469.500 LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 31S & 32S. REMOVED CORROSION FROM FLANGE IAW RD 8/4-53-2344. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. APPLIED ALODINE AND PRIMER TO FRAME FLANGE AS REQUIRED ISDR QXEA2011011000008Threshold · corrodedC2 CHECK - FWD PAX DOOR TRESHOLD HAS CORROSION. CORROSION FOUND TO BE OUT OF LIMITS. R & R THRESHOLD IAW MFG RD 8/4-53-1660.SDR QXEA2011011000010Cam · brokenRT LANDING GEAR ALTERNATE DOOR RELEASE (CAM MECHANISM ASSY) BROKEN. REF IPC 32-34-26, FIG 1, PAGE 0, PN 48510-1. FERRY FOR REPAIRS. RT ALTERNATE EXTENSION CAM MECHANISM R & R C/W GEAR SWINGS. OPS CHECKS GOOD. RETURNED TO SERVICE.SDR QXEA2011011000011Skin · damagedEXTERIOR FUSELAGE SKIN HAS IMPACT DAMAGE FROM BOTH LATCHES OF THE TOILET SERVICE DOOR. REMOVED DAMAGE IAW RD 8/4-53-2037. HFEC INSP SHOWED NO DEFECTS. PRIMED AND TREATED AREA.SDR QXEA2011011000009Valve · failedDEICE PRESS CAUTION ILLUMINATED IN FLIGHT BOTH BOOTS ON RT HORIZ STAB ILLUMINATED AT SAME TIME. DEICE PRESSURES NORMAL ON ALL CYCLES. INTERROGATED CDS ICE & RAIN PAGE & FOUND LOW PRESSURE 5B FAIL MESSAGE. C/W FIM TASK 30-10-00-810-814. INSPECTED RT INBD HORISDR QXEA2011010700005Power Supply · failedPDX A7 CHECK. EMERGENCY LIGHT ON PANEL 235BZ (CEILING) IS INOP. INSTALLED NEW POWER SUPPLIES IAW AMM TASK 33-51-01-400-801.SDR QXEA2011010700006Structure · corrodedPDX A7 CHECK. CORROSION FOUND AT THE LOWER AFT CORNER OF THE LAVATORY SERVICE DOOR OPENING. DRILLED OUT RIVETS AND CUT OUT DAMAGE AREA IAW RD 8/4-53-347. PERFORMED HFEC OF REMAINING MATERIAL FOR CRACKS. NO CRACKS NOTED. FABRICATED REPAIR PACKERS AND BACKING SDR QXEA2011010700007Bearing · corrodedMAIN CABIN DOOR FWD AND AFT GOOSENECK BRGS HAVE CORROSION INSIDE OF THEM. REPLACED THE BEARINGS IAW AMM 20-10-40.SDR QXEA2011010300955Floor Support · corrodedC2 CHECK - FLOOR SUPPORT WEB AT STA X32.400 JUST AFT OF FWD PAX DOOR ENTRY HAS AREAS OF CORROSION. REMOVED FLOOR SUPPORT WEB TO FOM IAW SRM 51-42-45. FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00. FABRICATED FLOOR SUPPORT WEB IAW TC 6-53-967 USING .050 2024T3SDR QXEA2011010300950Seat Track · corrodedC2 CHECK - RT INBD SEAT RAIL NR10 HAS AREAS OF CORROSION TOP AND BOTTOM SURFACES AT STA X16.000 XO AND X1.000-X7.000. FOUND SEAT RAIL TO BE OUT OF LIMITS IAW RD 8/4-53-884. REMOVED NR10 SEAT RAIL IAW SRM 51-42-05 AND 51-40-15. PREPARED AND INSTALLED NEW SESDR QXEA2010010400964Steering Sys · out of rigSELECTED GEAR UP-3 RED UNSAFE AND GEAR HANDLE ILLUMINATED. RAN CK LIST. WHEN SELECTED GEAR DOWN 3 GREEN AND HANDLE LIGHT OUT. TOWER VISUALLY VERIFIED GEAR DOWN. PERFORMED ALTERNATE EXTENSION. RETURNED TO THE FIELD. LANDING UNEVENTFUL. FERRY, CHECKED PSEU ASDR QXEA2010010400965Circuit Breaker · arcedCIRCUIT BREAKERS A1 AND C1 ON RT CB PANEL SHOW EVIDENCE OF ARCING AT THE TERMINAL LUG. RE-TERMINATED NEW TERMINAL LUGS AND REPLACED BOTH OF THE CB'S IAW WM 20-25-00. OPS TEST GOOD.SDR QXEA2010010400966Support · damagedRT DC CIRCUIT BREAKER PANEL SUPPORT HAS 4 ARCING SPOTS ALONG THE LT SIDE NEXT TO THE FASTENERS. PERFORMED A TEMP REPAIR FOR THE PANEL FRAME IAW RD 8/4-53-3490.SDR QXEA2011010300951Frame · corrodedC2 CHECK - FRAME X71.200 LOWER FLANGE HAS CORROSION BETWEEN STR 32S AND 33. REMOVED CORROSION IAW RD 8/4-53-2344. FOUND FLANGE TO BE WITHIN LIMITS. COMPLIED WITH RD 8/4-53-2344.SDR QXEA2011010300952Frame · corrodedC2 CHECK - FRAME X116.000 LOWER FLANGE HAS CORROSION BETWEEN STR 31P AND 32P. REMOVED CORROSION IAW RD 8/4-53-2344. FOUND FLANGE TO BE WITHIN LIMITS. COMPLIED WITH RD 8/4-53-2344.SDR QXEA2011010300953Access Panel · corrodedC2 CHECK - LT WING FUEL ACCESS PANEL 524BT MOUNT FLANGE HAS AREAS OF CORROSION AND MINOR FRETTING. REMOVED DAMAGE FROM ACCESS PANEL 524BT IAW RD 8/4-57-445. FOUND DAMAGE TO BE WITHIN LIMITS. RESTORED SURFACE PROTECTION IAW SRM 51-21-10-02-01 AND 51-25-40-0SDR QXEA2011010300954Access Panel · damagedC2 CHECK - LT WING FUEL ACCESS MOUNT FLANGE HAS AREAS OF FRETTING. REMOVED DAMAGE FROM MOUNT FLANGE IAW RD 8/4-57-445. FOUND FLANGE TO BE WITHIN LIMITS. RESTORED SURFACE PROTECTION IAW SRM 51-21-10-02-01 AND 51-25-40-02-01. COMPLIED WITH RD 8/4-57-445.SDR QXEA2011010400962Access Panel · corrodedC2 CHECK - LT WING FUEL ACCESS PANEL 524BT HAS AREAS OF CORROSION AND MINOR FRETTING. REMOVED DAMAGE IAW RD 8/4-57-442. FOUND WITHIN LIMITS IAW RD 8/4-57-442. RESTORED SURFACE PROTECTION IAW SRM 51-21-10-02-01 AND 51-25-40-02-01. COMPLIED WITH RD 8/4-57-44SDR QXEA2011010400963Access Panel · damagedC2 CHECK - LT WING FUEL ACCESS PANEL, 524AT HAS AREAS OF FRETTING. REMOVED DAMAGE IAW RD 8/4-57-442. FOUND WITHIN LIMITS IAW RD 8/4-57-442. RESTORED SURFACE PROTECTION IAW SRM 51-21-10-02-01 AND 51-25-40-02-01. COMPLIED WITH RD 8/4-57-442.SDR QXEA2010010300956Feel Sensor · malfunctionedON DECENT F/O LEG, RUDDER JAMMED UNTIL F/O APPLIED ENOUGH FORCE TO FREE RUDDER. DVI OF ALL RUDDER CABLE RUNS, RIGGING OF CABLE RUNS, AND REPLACEMENT OF RUDDER FEEL AND SUMMING UNIT. ALL RIG CHECKS AND OPS CHECKS NOW PASS. C/W FREEDOM OF MOVEMENT OF RUDDER ISDR QXEA2010010300957Door · frozenF/A REPORTS MAIN CABIN DOOR HARD TO OPEN FROM THE INSIDE CABIN. HANDLE HARD TO PUSH UP TO RELEASE DOOR. FOUND ICE AT THE BOTTOM, DOOR FRAME. CLEANED ICE OFF AND CHECKED DRAINS AND FOUND DRY. LUBRICATED DOOR. PERFORMED OPS TEST OF THE FWD PASSENGER DOOR IASDR QXEA2010010300959Door · icedF/A UNABLE TO OPEN MAIN CABIN DOOR. PERFORMEND GVI OF MCD AND FOUND ICE FROZEN TO MCD FWD & AFT GOOSENECK ATTACH POINTS. REMOVED BRUSH GUARDS AND DRAIN PLUGS AND MELTED ICE ACCUMULATION. INSTALLED BRUSH GUARDS AND DRAIN PLUGS AND PERFORMED OPS TEST OF MCD IASDR QXEA2010123000941Seat Track · corrodedC2 CHECK - RT INBD SEAT RAIL NR11 HAS SURFACE CORROSION AT STA 15.000. REMOVED MINOR CORROSION FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884. APPLIED ALODINE, PRIMER AND PAINT IAW SRM 51-21-10, 51-25-10 AND 51-25-15-02-01.SDR QXEA2010123000942Frame · corrodedC2 CHECK - CORROSION ON LOWER FLANGE OF AFT BAGGAGE COMPARTMENT STEPUP STA X783.10 LT SIDE. REMOVED LIGHT SURFACE CORROSION IAW SRM 51-21-00-00-02. FOUND TO BE WITHIN LIMITS IAW SRM 51-14-00-02-03. APPLIED ALODINE, PRIMER AND PAINT IAW SRM 51-21-10-02-01 ANSDR QXEA2010123000943Cargo Track · corrodedC2 CHECK - AFT BAGGAGE COMPARTMENT SEAT TRACK, NR 9 MID AND AFT AREA HAVE CORROSION. REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884 AND RD 8/4-53-2362. COMPLIED WITH STEP IAW RD 8/4-53-884 AND RD 8/4-53-2362.SDR QXEA2010123000944Cargo Track · corrodedC2 CHECK - AFT BAGGAGE COMPARTMENT SEAT TRACK NR 25 HAS CORROSION. REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884. COMPLIED WITH STEP IAW RD 8/4-53-884.SDR QXEA2010123000945Cargo Track · corrodedC2 CHECK - AFT BAGGAGE COMPARTMENT SEAT TRACK NR16 HAS CORROSION. REMOVED CORROSION IAW RD 8/4-53-884. FOUND TO BE WITHIN LIMITS IAW SRM 51-14-00-02-03. COMPLIED WITH STEPS IAW RD 8/4-53-884.SDR QXEA2010123000938Skin · corrodedC2 CHECK - AFT LT SCREW SPINNING ON THE LWR TCAS ANTENNA, TEMP REPAIR INSTALLED. REMOVED LWR TCAS ANTENNA IAW TC 344300Q01. REMOVED EXTERNAL DOUBLER, TRIPLER, INTERNAL FWD AND AFT INTERCOSTALS, AND THE PLASTIC DAM IAW SRM 51-42-05-02-01. FOUND CORROSION ON SDR QXEA2010010300960Cam · stickingRT MLG DOOR ALTERNATE EXTENSION CABLE CAM MECHANISM STICKS. REMOVED SAFETY WIRE APPLIED AS PART OF ANOTHER NON ROUTINE, CAM MOVES FREELY. NO DEFECTS NOTED.SDR QXEA2010010300961Proximity Sensor · out of adjustAFTER T/O, GEAR SELECTED UP, ALL 3 GEAR UNSAFE LIGHTS ILLUMINATED, GEAR DOOR LIGHTS DID NOT ILLUMINATE, GEAR HANDLE STAYED ILLUMINATED. F/A'S REPORTED BOTH MAIN GEAR WERE DOWN. RETURNED TO THE FIELD AND ACCOMPLISHED A UNEVENTFUL LANDING. FERRIED FOR REPAIRSSDR QXEA2010123000949Connector · not seatedDURING CLIMB EXPERIENCED MOMENTARY CHECK FIRE DET WARNING MESSAGE. COMPLIED WITH CHECK LIST. INTERROGATED CDS FOR FAULTS NO FAULTS LOG. INSPECTED APU FIRE DET SYS, RESEATED PNEUMATIC DETECTOR CONNECTOR. VISUAL INSP SHOWED NO DEFECTS. C/W AMM TASK 26-13-00-SDR QXEA2010122900946Panel · crackedTHREE CRACKS FOUND ON PANEL 422BL ABOVE AND BELOW THE 3RD FASTENER FROM THE BOTTOM. REPLACED PANEL 422BL.SDR QXEA2010122900947Engine · smokeAFTER STARTING BOTH ENGINES, BOTH PROPS OUT OF FEATHER, ALL SYS ON LINE, GROUND AGENT URGENTLY ADVISED EXCESS SMOKE COMING FROM NR 2 ENGINE COWLING, TOP AND SIDE. BOTH ENGINES IMMEDIATELY SHUTDOWN. CREW VERIFIED SMOKE AFTER SHUTDOWN BUT DIMINISHING. NO FIRESDR QXEA2010122900948Stick Shaker · malfunctionedDURING THE TAKE OFF ROLL, THE PUSH SYS FAIL CAUTION ILLUMINATED, TAKEOFF WAS ABORTED AT 50 KTS. C/W OPS CHECK OF THE ELEVATOR CONTROL STICK PUSHER IAW TASK 27-33-710-802, NO DEFECTS NOTED. COULD NOT DUPLICATE. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010122800939Unknown · odorBURNING ODOR COMING FROM BLEEDS AT POWER SETTINGS BELOW 25 PERCENT TQ. ODOR GRADUALLY DISAPPATES AT HIGHER POWER SETTINGS. INTEROGATED CDS FOR FAULTS , NONE NOTED. GROUND RAN BOTH ENGINES, NO ODORS NOTED WITH BLEEDS SELECTED. PERFORMED PURGE OF AC DUCTS IAWSDR QXEA2010122700934Cargo Track · corrodedC4 CHECK - AFT CARGO PIT SEAT TRACK NR9 HAS PITTING AT ST 744. BLENDED CORROSION IAW RD 8/4-53-884. DAMAGE REMOVAL FOUND TO BE WITHIN LIMITS OF MFG RD 8/4-53-2362. APPLIED ALODINE AS NECESSARY IAW SRM 51-21-10-02-01.SDR QXEA2010122700933Shear Tie · corrodedC4 CHECK - INTERNAL FUSELAGE FRAME TO SKIN FLANGE AT STA X71.200, STR 31R TO 30R HAS SURFACE CORROSION. REMOVED LIGHT SURFACE CORROSION IAW RD 8/4-53-2344. REMAINING FLANGE THICKNESS IS WITHIN LIMITS IAW RD 8/4-53-2344. TREATED, ALODINED, PRIMED AND PAINTEDSDR QXEA2010122700936Plate · malfunctionedPROP DE-ICE CAUTION ILLUMINATED. WHEN RESET, NR 1 SIDE ILLUMINATED, GOT DUAL AC GENERATOR CAUTION LIGHT. AC GENERATORS SUCCESFULLY RESET. R & R NR 1 PROP BACK PLATE ASSY. PERFORMED GVI NR 1 AC GENERATOR, AC CONTACT BOX, NR 1 PROP. C/W OPS TEST OF AC GEN SYSDR QXEA2010122700937Shutoff Valve · malfunctionedON APPROACH WITH POWER MACHED AND STABLZED, NR 2 ENG TORQUE JUMPED 10 PERCENT. BIG POWER LEVER SPLIT. POWER AGAIN STABLIZED, POWER LEVER MATCHED. TORQUE RISE AGAIN, POWER LEVER SPLIT. PATTERN REPEATED TO LANDING. SLIGHT SMOKEY/ OILY ODOR NOTED FROM BLEEDS. DSDR QXEA2010122200927Frame · corrodedC4 CHECK - INTERNAL FUSELAGE UNDERFLOOR AT STA 32.4000 FRAME FLANGES HAVE CORROSION BETWEEN STR 33 TO 32R, 32R TO 30R. REMOVED CORROSION IAW RD 8/4-53-2344. MIN MATERIAL REMAINING .039" REF NTM 51-00-02-250-801, FLANGES ARE WITHIN LIMITS IAW RD 8/4-53-2344. SDR QXEA2010122700935Brake Sys · malfunctionedEXCESSIVE BRAKING REQUIRED TO STOP. C/W BLEEDING OF THE BRAKE SYS. IAW AMM 32-42-00-870-801. C/W FUNCTIONAL TEST OF BRAKE SYS IAW AMM 32-42-00-720-801. CHECKS GOOD. C/W FUNCTIONAL TEST OF ANTI-SKID SYS IAW AMM 32-46-00-720-802. TESTS GOOD. C/W ANTI-SKID BUILTSDR QXEA2010122300930Controller · malfunctionedAUTOFEATHER ARM WENT BACK TO AUTOFEATHER SELECT BETWEEN 80 AND 100KTS. REPLACED NR1 PEC. RETURNED TO SERVICE.SDR QXEA2010122300931Door · frozenF/A ADVISES MAIN CABIN DOOR VERY DIFFICULT TO OPEN. FOUND MAIN CABIN DOOR TO OPEN AND CLOSE NORMAL. FOUND ICE AROUND DOOR REMOVED ICE FROM DOOR. NO FUTHER DEFECTS NOTED. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010122300932Power Supply · malfunctionedAFT INTERIOR EMERGENCY LIGHTS CAME ON WHEN THE BATTERY POWER WAS TURNED ON. REPLACED THE NR 4 EMERGENCY LIGHT POWER SUPPLY IAW AMM TASK 33-51-01-000-801. CHECKS GOOD. RETURNED TO SERVICE.SDR QXEA2010122100904Floor Panel · corrodedC4 CHECK - AFT CARGO PIT FLOOR 144DZ HAS CORROSION AROUND PANEL 144JZ CUTOUT. REMOVED CORROSION IAW SRM 51-21-00-00-02. COMPLIED WITH RD 8/4-53-3450.SDR QXEA2010122100905Floor Support · corrodedC4 CHECK - AFT CARGO PIT UPPER FLOOR ANGLE TO VERTICAL WEB AT ST 783.102 HAS SURFACE CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. MIN THICKNESS REMAINING .060" REF NTM 51-00-02-250-801. COMPLSDR QXEA2010122100906Angle · corrodedC4 CHECK - AFT CARGO PIT FLOOR WEB 144DZ, OTBD THRESHOLD ANGLE AT CARGO DOOR CUTOUT HAS CORROSION AROUND 2 FASTENER HOLES ST 747.602 AND 763.602. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. MIN THICKNESSSDR QXEA2010122100909Skin · corrodedC4 CHECK - INTERNAL FUSELAGE SKIN JOINT STRAP AND FRAME SKIN TIES AT STA 47.975 STR 30R TO 29L HAS SURFACE CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN THICKNESS REMAINING .047" REF NTM 51-00-02-250-801 AND FOUND TO BE BEYOND LIMIITS AS IAW SRM
Back to Pratt & Whitney Canada PW150A