Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2010111200733Structure · damagedON APPROACH, RECEIVED A BIRD STRIKE TO THE RT WING OTBD TO THE NACELLE. BIRD STRIKE DAMAGED THE FWD WING SPAR AND PENETRATED INTO THE FUEL TANK. ACFT IS CURRENTLY DOWN FOR REPAIRS.SDR QXEA2010111000727Switch · stickingCAPTAIN'S TCS BUTTON STUCK. RETURNED TO THE FIELD, LANDING UNEVENTFUL. R & R CAPTAIN'S TCS SWITCH AND A/P FUNCT TEST GOOD IAW TASK 22-11-00-720-801. ACFT REMAINS CAT III. PLACARD CAT III. ALL CHECKS GOOD IAW MX 6221101. RETURNED TO SERVICE.SDR QXEA2010110900721Smoke Detector · no testBAGGAGE FWD SMOKE DETECT INTERMITTANT, WILL NOT TEST. R & R FWD BAGGAGE SMOKE DETECTOR IAW AMM TASKS 26-12-06-000/400-801. PERFORMED OPS TEST OF BAGGAGE SMOKE DETECTORS IAW AMM TASK 26-12-06-710-801. OPS CHECK GOOD. CLEARS MEL 26-10-3.SDR QXEA2010110900722Wire Harness · failedDURING FLIGHT, PROP DEICE CAUTION LIGHT NR 2 ENGINE ILLUMINATE FOR 6 SEC AND THEN EXTINGUISHES. DIVERTED DUE TO ENROUTE WEATHER. LANDING UNEVENTFUL. CHECKED CDS AND FOUND NR2 TMCU FAULTS OPEN HEATER PHASE B AND OPEN HEATER PHASE C. COMPLIED WITH NR2 PROPELLER SDR QXEA2010111000726Seat Track · corrodedC5 CHECK - RT INBD SEAT TRACK HAS CORROSION STA X 644.50 REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW RD 84-53-884, ISSUE 3. REMOVED RT INBD SEAT TRACK IAW SRM 51-40-15-02-01 AND SRM 51-42-05-02-01. MATCH DRILLED NEW SEAT RAIL IAW SRM 51-40-07. INSTASDR QXEA2010110800718Brake · weakBRAKES ARE INEFFECTIVE. EXCESSIVE PRESSURE IS REQUIRED THEN THEY WORK ABRUPTLY. CHECKED CDS FOR ANTI-SKID FAULTS. NONE NOTED. CHECKED BRAKES FOR WEAR, CHECKED SERVICABLE. NOTE: ALL BRAKES FELT TO BE SAME TEMP. C/W ANTI-SKID CONTROL SYS. BITE TEST IAW AMM 3SDR QXEA2010110800720Trim Panel · malfunctionedON CLIMB F/O MOMENTARILY PRESSED AILERON TRIM RWD, AFTER 2 SECONDS AILERON TRIM DEFLECTED FULL RWD ON ITS OWN. RECENTERED TRIM IAW CHECKLIST AND IT SEEMED TO OPERATE NORMALLY. IAW MX CONTROL REQUEST, R & R FLIGHT DATA RECORDER AND ROUTED TO PDX AVIONICS FOR SDR QXEA2010110100692Strap · corrodedC2 CHECK - FWD PAX ENTRY FLOOR SUPPORT STRAP AT STR 23P BETWEEN STA X1.00 AND X38.400 HAS AREAS OF CORROSION. REMOVED CORROSION ON FWD PAX ENTRY SUPPORT STRAP AT STR 23P IAW SRM 51-21-00-00-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-20-23. REMOVED FWD PAX ENTSDR QXEA2010110300702Sensor · failedON ROTATION GOT A WEIGHT ON WHEELS CAUTION LIGHT. RETURNED TO FIELD. THE LIGHT CYCLED SEVERAL TIMES. LANDING UNEVENTFUL. PSEU INDICATED CAPTURED EVENT "LGWOW1 UNREASONABLY NEAR" WITH GEAR EXTENDED IN FLIGHT. R & R NR1 LGWOW PROX SENSOR IAW AMM TASK 32-61-06-00SDR QXEA2010110100673Frame · damagedC2 CHECK - FUSELAGE FRAME X94.800 LWR LEG HAS CORROSION BETWEEN STR 31S AND 32S. REMOVED RIVETS FOM IAW SRM 51-42-05. REMOVED CORROSION FROM FRAME FLANGE STA 94.800 STGR 31R-32R IAW SRM 51-21-00. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .034 REF NTM 51SDR QXEA2010110100674Frame · corrodedC2 CHECK - FUSELAGE FRAME X94.800 LOWER LEG HAS CORROSION BETWEEN STRINGERS 30S AND 31S. REMOVED RIVETS FOM IAW SRM 51-42-05. REMOVED CORROSION FROM FRAME FLANGE STA 94.800 STGR 30R-31R IAW SRM 51-21-00. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .036 RESDR CA101103002Hose · leaking(CAN) FLUID SQUIRTED FROM NOSE WHEEL AT END OF PUSHBACK, AIRCRAFT HAD PUSHED BACK FROM STAND. AT END OF PUSH AND WHILE DISCONNECTING TOW-BAR WHAT APPEARED TO BE HYDRAULIC FLUID SQUIRTED FROM NOSE-WHEEL AND HIT 2 RAMP OPERATIVES IN THE FACE AND EYES. FLEXIBLESDR QXEA2010110100695Autofeather Sys · malfunctionedAUTOFEATHER FAILED TO ARM ON TAKEOFF. ABORTED TAKEOFF AND RETURNED TO THE GATE. FOUND FAULT CODE 400 CH B NR2 PEC IN CDS. PERFORMED GVI OF NR 2 PEC, CONNECTOR PLUGS AND ASSOCIATED WIRING. NO DEFECTS NOTED. C/W NR2 PEC FAULT CLEAR IAW AMM TASK 61-20-36-070-80SDR QXEA2010110100676Seat Track · corrodedRT INBD SEAT TRACK JUST FWD OF STA X783.102 HAS SMALL AREA OF CORROSION. REMOVED CORROSION IAW SRM 51-21-00. MATERIAL LOSS INSIDE OF SEAT TRACK IS .031, MAX ALLOWED IS .050. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884. CONFIRMED CRACK FREE CONSDR QXEA2010110100675Seat Track · corrodedC2 CHECK - LT INBD SEAT TRACK HAS AREA OF CORROSION STA X644.50. REMOVED CORROSION IAW SRM 51-21-00. MATERIAL LOSS INSIDE OF SEAT TRACK IS .034, MAX ALLOWED IS .050. MATERIAL LOSS ON TOP OF TRACK IS .011 MAX ALLOWED IS .015. MATERIAL LOSS FOUND TO BE WITHISDR QXEA2010110100672Floor Support · corrodedC2 CHECK - FWD PAX ENTRY FLOOR SUPPORT WEB AT STA X38.400 HAS AREAS OF CORROSION. REMOVED CORROSION FROM WEB IAW SRM 51-21-00. MATERIAL LOSS IS .004, MAX ALLOWED IS .005. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW ENGINEERING DWG 824844 SHT 1, REV A AND SRSDR CA101027011Compass · misinstalled(CAN) C 12 COMPASS WHEN INSTALLED DID NOT FUNCTION, FOUND ISSUES WITH WIRING. THIS AREA WAS NOT TOUCHED DURING INSTALLATION.SDR QXEA2010110100696Governor · failedDURING PRE-FLIGHT FOUND THE NR2 PROPELLER NOT IN FULL REVERSE POSITION. PREVIOUS CAPTAIN REPORTED IT TOOK 25 SECONDS TO UNFEATHER. REPLACED THE NR 2 OVERSPEED GOVERNOR IAW TASK 61-20-26-000-801/400-801. OPS CHECKS GOOD. NO LEAKS NOTED. RETURNED TO SERVICE.SDR QXEA2010110100694Pseu · malfunctionedGEAR RETRACTED NORMALLY ALL LIGHTS WENT OUT 3-4 SEC LATER. LT MAIN GEAR UNSAFE LIGHT (RED) AND WHITE TRANSITION LIGHTS ILLUMINATED FOR 4-5 SEC. DOOR CAUTION LIGHTS DID NOT COME ON. ALTERNATE GEAR EXTENSION WAS PERFORMED. RETURNED TO THE FIELD LANDING UNEVENSDR QXEA2010102800671Actuator · malfunctionedWITH GEAR RETRACTION NOSE WHEEL REMAINED DOWN AND LOCKED FOR 23 SEC AFTER MAINS WERE UP AND LOCKED. NOSEWHEEL AMBER, RED AND UNSAFE LIGHTS REMAINED ILLUMINATED. GEAR CAME UP BY ITSELF AND LIGHTS WENT DARK. ALTERNATE GEAR EXT. ACCOMPLISHED. LANDING UNEVENTFUL.SDR CA101027003Pump · failed(CAN) ON CLIMB-OUT, THE NR 2 HYD PUMP CAUTION LIGHT ILLUMINATED. THE POWER TRANSFER UNIT AUTO STARTED. HYDRAULIC QUANTITY AND PRESSURE IN THE NR 2 SYSTEM WAS NORMAL. THE QRH CHECKLIST WAS ACTIONED. A "PAN PAN" CALL WAS MADE AND THE AIRCRAFT RETURNED FOR A SDR CA101108013Actuator · failed(CAN) WITH GEAR RETRACTION NOSE WHEEL REMAINED DOWN AND LOCKED FOR 23 SEC AFTER MAINS WERE UP AND LOCKED. NOSEWHEEL AMBER, RED AND UNSAFE LIGHTS REMAINED ILLUMINATED. GEAR CAME UP BY ITSELF AND LIGHTS WENT DARK. ALTERNATE GEAR EXT ACCOMPLISHED. REPLACED NLSDR QXEA2010102600670Battery Pack · dischargedEMERGENCY LIGHTS INOP FWD OF ROW 9. REPLACED THE FWD BATTERY PACKS. PERFORMED OPS CHECK OF THE SYS IAW AMM TASK 33-51-00-710-801. CHECKS GOOD. ACFT RETURNED TO SERVICE.SDR QXEA2010102500667Proximity Sensor · out of adjustCOE- NOSE GEAR DOOR FAILED TO RETRACT AFTER T/O. ACCOMPLISHED ALT GEAR EXT. WITHOUT INCIDENT. MAX AIRSPEED WAS 175 KIAS. RETURNED TO THE FIELD. LANDING UNEVENTFUL. NGLK1, NGLK2 AND NGDN2 PROXIMITY SENSORS ADJUSTED. LANDING GEAR EXTEND/RETRACT FUNCTIONAL TEST ASDR QXEA2010102500668Transducer · malfunctionedGEG- NR1 OIL PRESS FLUCTUATING 71-74 PSI. ALL TEMPS NORMAL. DIVERTED, LANDING UNEVENTFUL NR 1 ENG OIL PRESS TRANSDUCER REPLACED AND OIL PRESS REGULATOR ADJUSTED. GROUND RAN ACFT AT RATING POWER- NO DEFECTS NOTED. OIL PRESS STABLE. RETURNED TO SERVICE.SDR QXEA2010102500669Lamp · inoperativeFWD EMERGENCY LIGHT SWITCH LIGHT INOP. RELAMPED THE EMERGENCY LIGHT SWITCH LIGHT. OPS CHECKS GOOD.SDR NSVA2010190Connector · dirtyRETURNED TO GATE BEFORE TAKEOFF DUE TO POWERPLANT MESSAGE. CLEANED THE FADEC CONNECTORS ALONG WITH THE PECU CONNECTORS PER THE MANUAL. MX PERFORMED THE RUNS, OPS CHECKED GOOD AND THE POWER PLANT MESSAGE EXTINGUISHED.SDR QXEA2010102100661Fitting · chafedCOE - 9 YR - HORIZONTAL STABILIZER RT SIDE , ELEVATOR OTBD MOUNT FITTING INBD LWR SIDE HAS CHAFING MARK. BLENDED IAW RD 8/4-55-572. CONFIRMED AFFECTED AREA CRACK FREE REF RD 8/4-55-572 STEP 3. TREATED AND PAINTED IAW RD 8/4-55-572. ALL WORK COMPLIED WITH TASSDR QXEA2010102200665Link · wornAFTER GEAR RETRACTION ALL LIGHTS ON GEAR HANDLE & ANNUNCIATOR WENT DARK (NORMAL) , THEN LT MAIN GEAR UNSAFE (RED) AND GEAR DISAGREEMENT (HANDLE) ILLUMINATED FOR 3 SEC THEN ALL INDICATIONS BACK TO NORMAL. ALTERNATE GEAR EXTENSION PERFORMED. LANDING UNEVENTFUL. SDR QXEA2010102200664Landing Gear · malfunctionedNOSE GEAR SLOW TO RETRACT. DIVERTED. LANDING UNEVENTFUL.SDR QXEA2010101900623Seat Track · corrodedC5 CHECK - RT INBD SEAT TRACK ADJACENT TO FWD BAG PIT HAS AREAS OF CORROSION. EVALUATION AND MEASUREMENT OF CORROSION FOUND OUT OF LIMITS IAW RD 8/4-53-884. REMOVED RT INBD SEAT TRACK NR11 IAW SRM 51-42-05-02-01. DRILLED UP NEW SEAT TRACK IAW SRM 51-40-07 ASDR QXEA2010101900651Flasher · malfunctionedF/A ADVISES DURING EMERGENCY PA TEST THE RED LIGHT AT THE MID CABIN DOES NOT ILLUMINATED. RELAMP IS NO HELP. PLACED ON MEL 23-30-1B. CLEARED BY REPLACING THE FLASHER UNIT IAW AMM TASK 33-24-00-000-803 AND TASK 33-24-00-400-803. PSU AND INFORMATION SIGNS CHECKSDR QXEA2010101900652Handle · bindingMAIN CABIN DOOR HANDLE IS DIFFICULT TO OPERATE DURING OPENING OPERATION. COULD NOT DUPLICATE PROBLEM, INSPECTED DOOR AND FOUND NO DEFECTS. OPERATED DOOR SEVERAL CYCLES WITH NO DEFECTS. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010101900655Selector Valve · malfunctionedALTERNATE GEAR DOOR ON FLOOR WILL NOT OPEN FULLY. FERRIED FOR REPAIRS. REPLACED THE SECONDARY MLG SELECTOR VALVE IAW AMM TASK 29-21-06-000-801 AND 29-21-06-400-801. OPS TEST OF THE ALTERNATE EXTENSION SYS. GOOD. OK FOR CONTINUED SERVICE. DOOR OPENS FULLY. RESDR CA101108012Proximity Sensor · false activation(CAN) AFTER ROTATION WHEN GEAR WAS REQUESTED UP, CLIMBING OUT AND ACCELERATING TO 200 KTS AT AROUND 160 KTS GEAR HANDLE WAS ILLUMINATED WITH AMBER GEAR LIGHT ILLUMINATED, RED WARNING ILLUMINATED AT SAME AT SAME TIME FOR APPROX 10 SEC THEN OPERATED NORM. THEN SDR QXEA2010101800622Frame · corrodedINTERIOR FRAME FLANGE AT STATION X196.000 AT STRINGER 13R AFT SIDE HAS CORROSION. REMOVED RIVET FOR INSPECTION REMOVED CORROSION. MATERIAL REMOVED IS OUT OF LIMITS. FABRICATED REPAIR ANGLE FROM 0.63" 2024 T-3. INSTALLED REPAIR IAW SRM 53-10-15. PRIMED AND PAISDR QXEA2010101800648Downlock Sensor · malfunctionedAFTER ROTATION WHEN GEAR WAS REQUESTED UP, CLIMBING OUT AND ACCELERATING TO 200 KTS AT AROUND 160 KTS GEAR HANDLE WAS ILLUMINATED WITH AMBER GEAR LIGHT ILLUMINATED, RED WARNING ILLUMINATED AT SAME AT SAME TIME FOR APROX 10 SEC. THEN OPERATED NORM. THEN HANDLE SDR QXEA2010101400600Skin · damagedC5 CHECK - FORE RUDDER SKIN T/E HAS 3 AREAS OF DAMAGE BY THE UPPER HINGE POINT. PERFORMED CLEAN UP OF DAMAGED AREAS IAW SRM 51-14-00, REPAIR-03. MATERIAL LOSS LOWER AREA FOUND WITHIN LIMITS AND UPPER AREAS TO BE OUT OF LIMITS IAW SRM 51-14-00 REPAIR-03 PART SDR QXEA2010101400601Skin · damagedC5 CHECK - FORE RUDDER SKIN T/E HAS 2 AREAS OF DAMAGE BY THE CTR HINGE POINT. PERFORMED CLEAN UP OF DAMAGED AREAS IAW SRM 51-14-00 REPAIR-03. MATERIAL LOSS ON UPPER AREAS FOUND TO BE WITHIN LIMITS AND LOWER AREAS TO BE OUT OF LIMITS IAW SRM 51-14-00 REPAIR-0SDR QXEA2010101400602Skin · damagedC5 CHECK - FORE RUDDER SKIN T/E HAS 2 AREAS OF DAMAGE BY THE LOWER HINGE POINT. PERFORMED CLEAN UP FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00 REPAIR-03 PART 5-C-7-C. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-01-250-801. COMPLIED WITH TC RD 8/4-55-571SDR QXEA2010101400603Skin · damagedC5 CHECK - FORE RUDDER SKIN T/E HAS AN AREAS OF DAMAGE BY THE LOWER HINGE POINT. PERFORMED CLEAN UP OF DAMAGED AREAS IAW SRM 51-14-00 REPAIR-03. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-01-250-801. COMPLIED WITH TC RD 8/4-55-571 FOR PERMANENT REPAIRSDR QXEA2010101500606Doubler · corrodedC5 CHECK - LAV DRAIN MAST INTERNAL AND EXTERNAL DOUBLERS ARE CORRODED. REMOVED INTERNAL AND EXTERNAL DOUBLERS FROM ACFT IAW SRM 51-42-06-02-01. CORROSION ON DOUBLERS WAS FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00. FABBED NEW DOUBLERS IAW DWG 85328855, 85328SDR QXEA2010101500618Nut Clip · wornCOE - C5 CHECK - LAV DRAIN PORT ANCHOR NUT CLIP AT STA X28.000 STR 31R IS CORRODED. NUT CLIP PLATES WERE FOUND TO BE OUT OF LIMITS W/ MORE THAN 10 PERCENT THICKNESS OF CORROSION, IAW SRM 51-14-00. FABRICATED NUT NUT PLATE STRIP IAW DWG 85328857 AND HORIZON ASDR QXEA2010101800641Pin · corrodedLT MLG OTBD YOKE PIN HAS PITTING CORROSION.SDR QXEA2010101800642Bolt · corrodedNR2 INBD FITTING UPPER SPAR ATTACHMENT PIN BOLT IS CORRODED. REPLACED BOLT IAW AMM 20-10-01 TABLE 3.SDR QXEA2010101800643Pin · corrodedRT MLG OTBD YOKE PIN HAS PITTING CORROSION. REPLACED YOKE PIN IAW AMM 32-11-21-00-801.SDR QXEA2010101800645Unknown · odorWITH APU BLEED SELECTED ON STRONG ODOR FROM BLEEDS IN THE AFT GALLEY, WITH BLEED SELECTED OFF ODOR DISIPATES. C/W HS NR49-0006 PRIOR TO STARTING APU. STARTED APU IAW AMM TASK 49-00-00-869-801. APU OPS CKS NORMAL. NO ODOR FROM BLEED & NO OTHER DEFECTS NOTED. RESDR QXEA2010101800647Socket · looseF/A REPORT STRONG ODOR FROM AFT GALLEY. CREW STATED THE ODOR WAS A BURNED ELEC SMELL ISOLATED TO THE AFT GALLEY RT SIDE INSP READING LIGHT SWITCHES, EMERG LIGHT AND BALLAST ON/OFF NO ODOR NOTED INSP MAPCOS AND SOCKETS INCLUDING GVI OF ASSOC WIRING FOUND INBD SSDR QXEA2010101800646Valve · malfunctionedAFTER PUSHBACK IN SEATTLE WHEN CONDITION LEVERS BROUGHT TO MAX. ODOR FROM THE BLEED AIR SYS, SEEMS TO BE ELECTRICAL. REPLACED THE P2.2 VALVE, NO HELP. FERRIED FOR FURTHER WORK. RAN ENGINES AT DIFFERENT POWER SETTINGS AND BLEEDS ON AND OFF AND INTAKE HEAT ON ASDR QXEA2010101500620Frame · corrodedC5 CHECK - INTERIOR FRAME FLANGE AT STA X94.800 AT STR 31R AFT SIDE HAS CORROSION. REMOVED CORROSION FROM FLANGE IAW SRM 51-21-00. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .035" REF 51-00-02-250-801. LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-20-15 FIG 1
Back to Pratt & Whitney Canada PW150A