Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2010101800644Attach Fitting · crackedRT NACELLE INBD REAR SPAR ATTACH FITTING, HAS 2 SUSPECTED CRACKS. PERFORMED A FPI INSP AND CONFIRMED 2 CRACKS. UPPER ONE IS APPROX .5" LONG AND LOWER ONE IS APPROX .6875" LONG. REPLACED RT NACELLE INBD REAR SPAR ATTACH FITTING IAW TC SB84-54-15.SDR CA101012007Selector Valve · failedLANDING GEAR WOULD NOT EXTEND DURING APPROACH, USED ALT EXTENSION, ALL GREEN LAND SAFELY. (SDR 2010102301602/NSVA2010183)SDR CA101013001Sequence Valve · faultedONCE IN THE CRUISE THE LANDING GEAR INOP CAUTION LIGHT CAME ON, AFTER ABOUT 30 SECONDS IT WENT OFF AGAIN AND PROCEEDED TO DO THIS 3 TO 4 TIMES. IT THEN CAME ON AND REMAINED ON. THE FOLLOWING FAULT CODES WHERE RETRIEVED FROM THE PSEU, AS IAW FIM 32-10-00: PSESDR QXEA2010101400598Frame · corrodedCOE -C5 CHECK - INTERIOR FRAME FLANGE AT STA 32.40 BETWEEN STRINGERS 31R AFT SIDE HAS CORROSION. REMOVED CORROSION FROM FLANGES AT STA 32.40 STR 32-31R AND STR 31-30R IAW SRM 51-21-00. MEASURED AFFECTED AREA, MIN MATERIAL REMAINING .035" REF NTM 51-00-02-250SDR QXEA2010101400599Frame · corrodedC5 CHECK - INTERIOR FRAME FLANGE AT STA 47.975 AT STRINGERS 31R AFT SIDE HAS CORROSION. REMOVED CORROSION FROM FLANGES AT STA 47.975 STR 32-31R AND STR 31-30R IAW SRM 51-21-00. MEASURED AFFECTED AREA, MIN MATERIAL REMAINING .054" STR 30-31 AND .052" STR 31-32SDR QXEA2010101400607Door · bindingUPON OPENING THE MAIN PAX DOOR (L1) THE F/A REPORTS THAT RAMP HAD A DIFFICULT TIME CLOSING THE DOOR AND THE F/A HAD A DIFFICULT TIME OPENING THE DOOR. CLEANED AND LUBED MAIN CABIN DOOR. PERFORMED FUNCTIONAL CHECK OF THE AIRSTAIR DOOR IAW AMM TASK 52-11-00-720SDR QXEA2010101400608Brake · draggingNO BRAKES AFTER TOUCHDOWN WITH FULL FORCE APPLIED THEN PULSATED DURING SLOW DOWN, MOSTLY ON RT SIDE AT LOW SPEEDS. ON TROUBLESHOOTING, PERFORMED LOW SPEED TAXI, FOUND BRAKING FUNCTION TO BE NORMAL WITHOUT ANTI SKID ON. WITH ANTI SKID ON BRAKES PULSED ON AND OFSDR QXEA2010101400609Sensor · malfunctionedAFTER TAKEOFF FROM LT MAIN GEAR UNSAFE (RED) LIGHT STAYED ON AND STARTED FLASHING. GEAR HANDLE UNSAFE LIGHT ILLUMINATED THE SAME AS THE GEAR HANDLE AMNUNCIATOR LIGHT. RETURNED TO FIELD. LANDING UNEVENTFUL. REMOVED LT MLG PROXIMITY SENSORS IAW AMM 32-61-06-SDR CA101108011Proximity Sensor · failed(CAN) AFTER TAKEOFF, LEFT MAIN GEAR UNSAFE (RED) LIGHT STAYED ON AND STARTED FLASHING. GEAR HANDLE UN SAFE LIGHT ILLUMINATED THE SAME AS THE GEAR HANDLE ANNUNCIATOR LIGHT. MAINTENANCE: REMOVED LEFT MLG PROXIMITY SENSORS IAW DASH 8 400 AMM 32-61-06-000-802. SDR QXEA2010101300596Governor · malfunctionedAFTER START, WHEN CONDITION LEVERS ADVANCED TO 1020, PROP NR2 DID NOT ADVANCE OR COME OUT OF START AND FEATHER. AFTER 90 SECONDS,PLACED THE NR2 CONDITION LEVER TO START & FEATHER FOR 1 MIN. THEN ADVANCED TO 1020, THE PROP TOOK APPROX 45 SECONDS. 2ND ATTEMPT SDR QXEA2010101100586Seat Track · corrodedC CHECK - RT INBD SEAT TRACK HAS A SPOT OF CORROSION AT STA X125.000. MAX MATERIAL REMOVED .018" IAW RD 8/4-53-884 REV FOR ABOVE REF IS MAY 04. CONFIRMED AFFECTED AREA IS CRACK FREE CONDITION OF REF Q400 NTM 51-00-01-250-801 REV 5. BLEND IS WITHIN LIMITS IAW SDR QXEA2010101100591Propeller · malfunctionedNR2 ENGINE TOOK LONGER THAN 30 SECONDS TO START AND FEATHER POSTION TO MIN 850 RPM. INTERROGATED CDS, FOUND NO FAULTS. PERFORMED FUNCTIONAL CHECK OF PROP TIME TO UNFEATHER ON NR2 ENG. IAW AMM TASK 61-20-00-720-801, NR2 PROP UNFEATHERED WITH IN TIME LIMITS, NO SDR QXEA2010101100587Control Unit · malfunctionedWITH AUTO PILOT OFF, EXCESS PRESSURE REQUIRED TO PULL BACK YOKE FOR ROTATION ON TAKEOFF AND SAME FOR FLARING UPON LANDING ACFT. REPLACED NR1 SSCU IAW AMM TASK 27-61-05-000-801-A01 AND 27-61-05-400-801-A01. OPS CHECK GOOD. FUNCTIONAL TEST OF THE PITCH FEEL SYS SDR QXEA2010101100588Bleed Valve · malfunctionedFOUL SMELL FROM BLEED AIR DUCTING (APU AND ENGINES RUNNING). REPLACED NR1 & NR2 ENGINE P2.2 INTERSTAGE BLEED VALVES IAW AMM TASK 75-31-11-000-801 & -400-801. GROUND RAN ACFT & PERFORMED REMOVAL OF ODOR FROM A/C DUCTS IAW TASK 21-00-00-160-801. NO DEFECTS NOTEDSDR QXEA2010100800581Unknown · odorBURNED TRANSMISSION FLUID ODOR AT 30 PERCENT TORQUE ON DESCENT IN THE CABIN AND FLIGHT DECK. POWER LEVER SPLIT ALSO AT POWER SETTINGS BETWEEN 30 PERCENT AND 60 PERCENT TORQUE WITH THE NR 2 POWER LEVER .2500" FWD OF THE NR1. PURGED THE BLEED AIR SYS IAW SL DH8SDR QXEA2010100700580Brush Block · malfunctioned"PROP DEICE" CAUTION ILLUMINATED DURING CLIMBOUT -4C LIGHT ILLUMINATES WHEN NR2 PROP DEICE COMES ON. RETURNED TO FIELD. LANDING UNEVENTFUL. INTERROGATED CDS, FOUND FAULT CODE TMCU(14) IN TMCU2. C/W CONTINUATY CHECK OF THE PROPELLER DEICING HEATER ELEMENT IAW SDR QXEA2010100600578Filter · dirtySLIGHT OILY ODOR IN BLEEDS ON DECENT, ODOR LIKE DIRTY GYM SOCKS. INSPECTED NR1 AND NR2 ENGINES CHECKED THE CIS FOR DEFECTS NONE NOTED. CHECKED INTAKE ADAPTORS, INTAKE THROATS, ENGINE COMPARTMENTS AND CP HOOK UP FOR ANY DEFECTS. NO DEFECTS NOTED. R & R RECIRSDR QXEA2010100600579Coffeemaker · odorTWO COFFEEMAKERS IN REAR ARE NOT HEATING, F/A SAY THEY SMELL LIKE ASBESTOS. REPLACED BOTH COFFEEMAKERS, ONE HAD LOW COFFEE. BOTH OP'S CK GOOD NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.SDR QXEA2010100400575Door · bindingLANDING GEAR ALTERNATE EXTENSION DOOR DIFFICULT TO FULLY OPEN. CLEANED AND LUBRICATED DOOR. OPS CHECK GOOD. NO OTHER DEFECTS NOTED. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010100400577Skin · crackedCRACK ON TRAILING RUDDER LT UPPER SIDE (RIB 28) THIRD FROM THE TOP. REPLACED TRAILING RUDDER. CHECK FLIGHT GOOD. RETURNED TO SERVICE.SDR QXEA2010100400573Power Supply · malfunctionedFWD PAX DOOR, EMERGENCY EXIT SIGN AND EGRESS LIGHT ILLUMINATED WHEN BATTERIES SELECTED OFF. TROUBLESHOT TO FAULTY EMERGENCY PWR SUPPLY UNIT NR1 . R & R IAW AMM TASK 33-51-01-000-801 AND 33-51-01-400-801. C/W OPS TEST OF EMERGENCY LIGHTS IAW AMM TASK 33-51-00-SDR QXEA2010100400574Door · bindingMAIN CABIN DOOR DIFFICULT TO OPEN. CLEARED MCD OF DEBRIS AND WATER IAW AMM 53-20-23-680-801. CLEANED AND LUBED DOOR AND HANDRAILS AS REQUIRED. PERFORMED OP'S TEST OF DOOR IAW 52-11-00-710-802. OPS CHECK GOOD. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010100400576Shutoff Valve · failedNR 1 & NR 2 BLEED AIR HOT CAUTION LIGHTS ILLUMINATED AFTER APPLYING TO POWER. REPLACED ABSOLUTE PRESSURE SENSOR IAW 21-52-06-400-801 AND REPLACED NR2 NACELLE SHUTOFF VALVE IAW AMM 36-11-19-400-801. OPS CHECKS GOOD. RETURNED TO SERVICE.SDR QXEA2010092800564Splice · corrodedC-CHECK - UPON REMOVAL OF APU DC GEN TO FOM, FOUND CORROSION ON SPLICE STRAP FROM STA 281-301, S32-31L. REMOVED FASTENERS TO ACCESS CORROSION REMOVAL IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MEASURED AFFECTED AREA MINIMUM REMAINING SDR QXEA2010092500568Rvdt · out of adjustACFT PULLS TO THE LT DURING LANDING AND TAXI. ON LANDING ROLL AT SPEEDS ABOVE 40 KTS SIGNIFCANT RT RUDDER NEEDED TO MAINTAIN CTR LINE. WINDS WERE CALM. CHECKED RIGGING OF THE NOSE WHEEL STEERING RVDTS IAW AMM 32-51-00-830-801 AND ADJUSTED BOTH RVDTS AS REQUISDR QXEA2010092900569Power Supply · failedWHEN ACFT IS POWERED DOWN, FWD. EMERGENCY LIGHTS STAY ON. R+R FWD. EMERGENCY LIGHT PWR. SUPPLY UNIT, IAW AMM TASKS 33-51-01-000-801,33-51-00-400-801, ALSO R+R BATTERY PACKS IN FWD PWR SUPPLY UNIT IAW AMM TASK 33-51-00-820-801. OP'S CHECK GOOD. IAW AMM TASK 33SDR QXEA2010092700563Floor Panel · corrodedC-CHECK - FLOOR PANEL 144JZ HAS AREAS OF CORROSION. REMOVED SURFACE CORROSION, NO MEASURABLE MATERIAL LOSS NOTED. TREATED AND PAINTED IAW SRM 51-21-10 AND SRM 51-25-10. DINOTROL APPLIED IAW AMM 51-25-01-390-801.SDR QXEA2010092800567Lamp · failedF/A'S EMERGENCY LIGHT SWITCH WILL NOT ILLUMINATE IN THE "NORMAL" POSITION. RELAMPED THE SWITCH. CHECKS GOOD.SDR CA101006001Fuel Control · failedTORQUE FLUCTUATIONS, THE ENGINE EXPERIENCED A NO-START EVENT WHILE PREPARING FOR A REVENUE FLIGHT. PRIOR TO THIS EVENT, THE ENGINE HAD EXPERIENCED SOME TORQUE FLUCTUATIONS ON THE FLIGHTS PRECEDING THE NO-START EVENT. THE TORQUE WAS SEEN OSCILLATING BETWEEN 88SDR QXEA2010092700554Frame · corrodedC-CHECK - FRAME AT STA 301.000 LOWER ATTACH FLANGES BETWEEN STR 31L AND 31R HAVE MINOR CORROSION. REMOVED CORROSION FROM FLANGES IAW SRM 51-21-00. REMOVED RIVETS TO FOM IAW SRM 51-40-07. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .044" REF HORIZON NTM 4.2SDR QXEA2010092700555Web · corrodedC-CHECK - AFT CARGO COMPARTMENT FLOOR LEVEL WEB IS CORRODED IN MULTIPLE AREAS JUST AFT OF STA 728.102. REMOVED FLOORBOARD STA 704-722 IAW SRM 51-42-05 AND 51-40-10. REMOVED CORROSION FROM WEB IAW SRM 51-40-00. MEASURED MIN MATERIAL REMAINING .046" FOUND HOSDR QXEA2010092200549Connector · looseAFT BAGGAGE INLET VALVE CLOSED LIGHT WILL NOT ILLUMINATE ON TEST. BULB TESTS OK. CYCLED "VENT VALVES" CIRCUIT BREAKERS, RESEATED VENT VALVE (AFT CARGO PIT) CONNECTOR PLUG. INLET VENT VALVE CLOSED LIGHT OPS CHECKS GOOD WITH VENT VALVE TEST. NO FURTHER DEFESDR QXEA2010092200550Engine · failedAPU FAILED ON START, RAMP REPORTED SMOKE FROM APU EXHAUST, APU L3 SOV C/B POPPED. PLACED APU ON MEL 49-00-1. RETURNED TO SERVICE.SDR QXEA2010092200551Fan · failedBURNING ODOR IN DUCTS WITH RECIRC FAN ON ODOR LESSENS WITH FAN OFF. REMOVED RECIRC FAN IAW AMM TASK 21-22-16-00-801. INSTALLED SERVICEABLE FAN IAW AMM TASK 21-22-16-400-801. OP CHECKS GOOD. RETURNED TO SERVICE.SDR QXEA2010092100545Valve · malfunctionedDURING MORNING CHECKLIST THE AFT BAGGAGE COMP INLET VENT VALVE WOULD NOT CLOSE DURING AFT BAGGAGE COMP FIRE TEST. R & R AFT BAGGAGE COMP. INLET VENT VALVE IAW AMM TASK 21-22-74-000-801/TASK 21-22-74-400-801. OPS CHECKED GOOD. NO OTHER DEFECTS NOTED. RETURNSDR QXEA2010092100546Switch · unsecureEMERGENCY LIGHTS REMAIN ON WHEN IN THE "ARM" POSITION. INSPECTED AND FOUND THE F/A'S EMERGENCY LIGHT SWITCH NOT FULLY SECURED. RESECURED SWITCH. OPS CHECKS GOOD. LIGHTS DO NOT COME ON IN "ARM" POSITION. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010092100547Connector · damagedNR 2 FUEL TEMP FLUCUATES BETWEEN 60-99C, WITH OCCASIONAL DASH LINES REPLACING THE TEMP READING. RETURNED TO FIELD. LANDING UNEVENTFUL. INSPECTED HARNESS TO TEMP SENSOR AND FOUND IT TO BE TIGHT, DISSASSEMBLED CONNECTOR PLUG AND DISCOVERED WIRE SEPARATED FROM SDR QXEA2010092000544Panel · leakingWHILE REFUELING TO AN ALMOST FULL FUEL LOAD FOR TANKERING (10,500 LBS), FUEL BEGAN LEAKING FROM THE RT WING (ON TOP) SPILLING DOWN THE FRONT, INBD OF THE NR2 ENG NACELLE. INSPECTED AND FOUND FUEL PANEL 622BT LEAKING FUEL ONLY DURING PRESSURE REFUELING OPERATIOSDR QXEA2010092000543Pressure Switch · malfunctionedFLAP DRIVE CAUTION LT ILLUMINATED SEVERAL TIMES DURING CLIMB AND CRUISE. FLAPS OPERATED NORMALLY DURING LANDING. DIVERTED TO PSC AND ACCOMPLISHED A UNEVENTFUL LANDING. REMOVED FLAP POWER UNIT PRESSURE SWITCH IAW AMM TASK 27-52-01-000-802 INSTALLED NEW PRESSURSDR QXEA2010091700541Fire Warning · false activationMASTER WARNING CHECK FIRE DETECTED WITH APU BOTTLE LOW LIGHT. PERFORMED FIRE TEST OF APU, OPS TEST GOOD. APU FIRE PANEL BTL LOW NOT ILLUMINATED. OPS CHECK OF APU CHECKS GOOD NO DEFECTS NOTED. NO CURRENT FAULTS IN CDS. PERFORMED GVI OF APU AND APU FIRE BOSDR QXEA2010091700542Fire Bottle · malfunctionedMASTER CAUTION CHECK FIRE DETECT BOTTLE LOW APU INTERMITTENT ON APPROACH AND AFTER LANDING, EVENT MARKER PRESSED. R & R APU FIRE EXTINGUISHER BOTTLE IAW AMM TASKS 25-23-01-000-801/ 400-801. SYS TESTED GOOD. RETURNED TO SERVICE.SDR QXEA2010091600539Unknown · odorF/A SMELL SOMETHING IN THE AFT GALLEY POSSIBLY ELECTRIC. PERFORMED GVI OF THE AFT GALLEY, NO ABNORMAL SMELL OR OTHER DEFECTS NOTED. ACFT OK FOR CONTINUED SERVICE. NO PARTS REPLACED.SDR QXEA2010091400538Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPERATE. CLEANED AND LUBED THE MAIN CABIN DOOR STOPS. DOOR OPENS AND CLOSES OK. RETURNED TO SERVICE. NO PARTS REPLACED.SDR NSVA2010160Handle · unsecureDURING CRUISE, "FUSELAGE DOORS" WARNING LIGHT ILLUMINATED. THERE WAS NO LOSS OF CABIN PRESSURIZATION AND THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. MX MET THE ACFT AND FOUND THE DOOR HANDLE IN THE POPPED OUT POSITION. MX LUBED THE LOCK ASSY. OPS CHECKED OKSDR QXEA2010090900527Skin · chafedC-CHECK- LT WING OB FLAP UPPER SKIN HAS 64IN OF CHAFING FROM WING T/E SHROUD. BLENDED FLAP SKIN IAW SRM 57-52-30-02-01. MEASURED AFFECTED AREA MIN MATERIAL REMAING .029 REF HORIZ NTM 4.2.0-1. THICKNESS IS WITHIN LIMITS IAW HORIZ RD 8/4-57-1428. REWORKED ARESDR QXEA2010090900528Skin · chafedC-CHECK - LT WING OTBD FLAP L/E INBD END HAS CHAFING .2500 IN BY .1250 IN WIDE. BLENDED DAMAGE IAW SRM 51-14-00. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .052 REF HORIZON AIR NTM 4.2.0-1. REMAINING THICKNESS IS WITHIN LIMITS IAW RD 8/4-57-1427. INSPECTSDR NSVA2010158Solenoid Valve · inoperativeDURING GEAR EXTENSION GOT 3 REDS AND NO INTRANSIT LIGHT. USED ALTERNATE GEAR EXTENSION PROCEDURE AND GOT THREE GREENS, LANDED WITHOUT FURTHER INCIDENT. AFTER LANDING AND TAXIING OFF THE ACTIVE RUNWAY, SHUTDOWN TO PIN GEAR AND TAXIED TO THE GATE. INSPECTED ACFTSDR QXEA2010091000534Flap Track · damagedVERY LOUD SCRAPING NOISE HEARD FROM RT WING ROOT AREA WHEN LDG-GEAR WAS EXTENDING. CYCLED LANDING GEAR WITH ANTI-SKID ENGAGED, CYCLED FLAPS, CYCLED AILERONS/SPILLERS, RAN PTU DURING GEAR CYCLING. UNABLE TO DETECT ANY ABNORMAL NOISES AS DESCRIBED. ALL SYS OPESDR QXEA201009100534Smoke Detector · no testFWD BAGGAGE SMOKKE DETECTOR FAILED TEST. REPLACED FWD BAGGAGE SMOKE DETECTOR IAW 26-12-06-000-801 AND 26-12-06-400-801. OPS TEST GOOD. RETURNED TO SERVICE.SDR CA100908002Selector Valve · inoperativeDURING LANDING, LANDING GEAR WOULD NOT EXTEND, USED ALT EXTENSION, ALL LIGHTSGREEN, LAND SAFELY. UPON LANDING THE SWITCHES WERE RETURNED TO NORMAL BUT THE GEAR DOORS REMAINED OPEN. LANDING GEAR SELECTOR VALVE REPLACED.
Back to Pratt & Whitney Canada PW150A