Pratt & Whitney Canada PW150A
Service difficulty reports · 3,094
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW150A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA100804001Engine · smoke(CAN) SMOKE IN CABIN DURING FLIGHT, ON APPROACH, PILOTS REPORTED SMOKE IN THE CABIN. ACFT LANDED AND THE ENGINE AUTO-SHUTDOWN ON TOUCHDOWN. THE ENGINE WILL BE REMOVED AND FORWARDED TO MFG FOR INVESTIGATION.SDR QXEA2010072600442Antenna · failedWX FAIL ON BOTH MFD'S. RETURNED TO THE FIELD, LANDING UNEVENTFUL. R & R WEATHER RADAR ANTENNA IAW AMM TASKS 34-41-06-000-801 AND 34-41-06-400-801 , PERFORMED OPS CHECK IAW AMM TASKS 34-41-00-710-801 AND 34-41-00-710-802 , OPS CHECK GOOD NO FURTHER DEFECTS NOTESDR QXEA2010072600443Actuator · failedOIL TEMP ON NR 1 ENG AS HIGH AS 112 DEG ALL OTHER INDICATIONS NORMAL. RETURNED TO THE FIELD. LANDING UNEVENTFUL. DURING T/S FOUND OIL COOLER FLAP DOOR ACTUATOR FAILED, DOOR WOULD NOT OPEN. R & R OIL COOLER FLAP DOOR ACTUATOR IAW AMM TASK 79-21-31-000/400-801. SDR CA100723001Actuator · failedOIL TEMP ON NR 1 ENG AS HIGH AS 112 C. ALL OTHER PARAMETERS NORMAL. MX FOUND: FOUND OIL COOLER FLAP DOOR ACTUATOR FAILED, CLOSED. REPLACED ACTUATOR.SDR QXEA2010072100428Solenoid Valve · malfunctionedAFTER GEAR SELECTED UP ON TAKEOFF, NOSE GEAR DOORS FAILED TO CLOSE. COMPLIED WITH ALT GEAR EXTENSION METHOD AND RETURNED TO FIELD. LANDING WAS WELL BELOW MAX LDG WEIGHT. ACFT TOWED OFF RUNWAY. FERRIED FOR REPAIRS. FOUND NO RELEVENT FAULTS IN PSEU, REPLACESDR QXEA2010071600423Engine · overtempSEA- ON T/O ROLL TORQUE OBSERVED IN RED. SPEED BELOW 50KTS. ABORTED TAKEOFF. FOUND NR 1 ENG QTOT EXCEEDANCE PEAK VALUE 32320, TIME OVER LIMIT 3 SEC.NR 2 ENG QTOT EXCEEDANCE PEAK VALUE 32286, TIME OVER LIMIT 3 SEC. Q400 AMM 05-11-00 PG6 FIG1 TR05-092 SHOWS BOTHSDR QXEA2010071400417Control Panel · malfunctionedGREEN LIGHT MAIN GEAR INDICATOR STAYED ILLUMINATED AFTER GEAR RETRACTION. R & R LANDING GEAR CONTROL PANEL, IAW AMM TASK 32-31-01-000-801, 32-31-01-400-801, FUNCTIONAL TEST GOOD, IAW AMM TASK 32-31-01-720-801. INSPECTED LANDING GEAR HARNESS, NO DEFECTS NOTED.SDR CA100713002Generator · inoperative(CAN) DURING CRUISE, NR 1 ACFT GEN CAUTION LIGHT CAME ON. FLIGHT CREW OPTION TO RETURN TO DEPARTURE AIRPORT. ON GROUND TROUBLESHOOTING REPLACED NR 1 AC GENERATOR FUNCTION TESTED OK. ACFT WAS RETURNED TO SERVICE.SDR CA100708005Fan · failed(CAN) STRONG ODOR OF BURNING PLASTIC AND SMOKE WERE DETECTED IN COCKPIT AND CABIN BY FLT CREW RIGHT AFTER DEPARTING EWR. THESE PERSISTED THROUGHOUT ENTIRE EVENT UNTIL SHUTDOWN. EMERGENCY MEASURES INITIATED AND ACFT RETURNED & PAX BACK TO TERMINAL. ACFT SECUSDR CA100712001Fire Warning · illuminatedIN-FLIGHT FIRE WARNING AFTER DEPARTURE, THE NR1 ENGINE FIRE WARNING ILLUMINATED. THE FIRST FIRE BOTTLE WAS DISCHARGED AND THE CREW ELECTED TO RETURN TO POINT OF DEPARTURE. EN ROUTE BACK TO DEPARTURE, THE FIRE WARNING AGAIN ILLUMINATED AND THE SECOND FIRE BOTTSDR QXEA2010070800391Seal · leakingON CLIMBOUT OF 21,000 HAD A VERY LOUD WHINE COMING FROM RT FWD EMERGENCY EXIT CABIN DIFFERENTIAL WAS 4.5 PSI CABIN ALT WAS 6000. RETURNED TO FIELD. LANDING UNEVENTFUL. INSPECTED DOOR SEAL AND MATING SURFACE, RECONTOURED SEALANT AT UPPER AND LOWER DOOR INTERSSDR CA111110004Wire Harness · burned(CAN) AFTER CHANGING FLUX VALVE AND AHIRS COMPUTER THAT FIXED INITIAL WRITEUP FOR HEADING FLAG, RUNNING AC AND NR 1 AUX FUEL PUMP BREAKER POPPING. FOUND BAD WIRE BUNDLE. CURRENTLY T/S TO ISOLATE FUEL PUMP WIRING. BUNDLE FOUND UNDER FLOORBOARD JUST BEFORE STSDR QXEA2010070200376Doubler · corrodedC CHECK - NR2 COMM ANTENNA DOUBLER HAS EXTERNAL CORROSION. REMOVED CORROSION FROM OUTER SURFACE. UT THICKNESS CHECKED AFFECTED AREA IAW D8-400 NDTM PART 1, 51-00-04, HI=.071" LOW=.068". HFEC INSPECTED AFFECTED AREA FOR CRACKS IAW NDTM PART 6, 51-00-01, NO SDR QXEA2010070100372Arm · chafedC CHECK -THERE IS AN APPROX 6" CHAFED AREA ON THE BOTTOM OF THE MAIN HINGE ARM FOR THE AFT SERVICE DOOR. REMOVED CHAFE DAMAGE BY BLENDING IAW SRM 51-14-00-02-01. DIMENSIONS OF BLEND ARE AS FOLLOWS: LENGTH 1.20", WIDTH 0.38" AND DEPTH OF BLEND IS .004". BLESDR QXEA2010063000368Angle · corrodedC-CHECK - FUSELAGE VERTICAL WEB AT FS X783 HAS CORROSION ON BOTTOM ANGLE ALONG AFT SIDE 11" LT OF C/L THROUGH 23" LT OF C/L. REMOVED (4) FASTENERS IN BOTTOM ANGLE FOR FOM. REMOVED PITTING CORROSION ON BOTTOM ANGLE WITH SCOTCHBRITE REF SRM 51-21-00. PERFORMEDSDR NSVA2010108O-Ring · damagedDURING TAXI, F/A REPORTED TO CAPTAIN THAT THERE WAS AN ODOR IN THE CABIN. CAPTAIN SMELLED FAINT TRACE OF ODOR AND RETURNED TO GATE. FOUND FUEL LEAKING FROM NR 2 ENG TRANSFER TUBE ON FUEL OIL HEAT EXCHANGER. REMOVED AND REPLACED O-RINGS ON THE FUEL OIL HEAT SDR QXEA2010070100375Engine · shutdownAFTER PUSH BACK AND ENGINES START, ADVANCED CONDITION LEVERS OUT OF START AND FEATHER TO MAX, BOTH ENGINES SHUT DOWN. RETURNED TO THE GATE. INTERROGATED CDS, FOUND FAULT CODES 968 A AND B 3 1 ENGINE. 968A NR 2 ENGINE. PERFORMED FIM TASK NR73-20-00-810-821. OPSSDR CA100705006Selector Valve · malfunctioned(CAN) PILOT REPORT: AFTER TAKEOFF AND SELECTING LANDING GEAR TO THE UP POSITION. LEFT MAIN GEAR DID NOT COME UP. LT DOOR AMBER AND LT DOOR RED WERE ILLUMINATED. COMPLETED CHECK LIST AND ALTERNATE GEAR EXTENSION CHECKLIST AND ALL THE GEAR CAME DOWN AND LOCKESDR QXEA2010062100358Structure · crackedFRONT OTBD CLIP ON RT NACELLE SPINE COWL IS CRACKED UNDER WASHER. REMOVED AND REPLACED DAMAGED CLIP REF RD 8/4-71-032.SDR CA100621006Bulkhead · damagedNR 1 ENG FIRE, CHECK FIRE DETECT LIGHT DURING FLIGHT. ENG SHUTDOWN AND 1 FIRE BOTTLE DISCHARGED. FOUND NR 1 ENG "HORSE COLLAR" FOUND DAMAGED. "HORSE COLLAR" REPLACED. Q400 NACELLE HAS A SINGLE FIRE ZONE WITH AN EDUCTOR/EJECTOR DRIVEN VENTILATION SYS. THE SYSSDR QXEA2010061700355Connector · damagedFOLLOWING GEAR SELECTION TO UP, GEAR DID NOT RETRACT NORMALLY. ON INITIAL GEAR RETRATION THE GEAR GEAR HANDLE ILLUMINATED AND ALL 3 RED GEAR UNSAFE LIGHTS ILLUMINATED, FOLLOWING A DELAY OF APROX 5-10 SECS GEAR RETRATION CONTINUED NORMALLY TO COMPLETION. FOR GESDR QXEA2010061600350Bulkhead · chafedMOD - THERE IS POSSIBLE CHAFE ON FWD FACE OF LOWER FWD PRESSURE BULKHEAD AT STA X-111.00. BLENDED AREA OF CHAFE AND FOUND IT TO BE WITHIN LIMITS IAW SRM 53-10-19 WITH .010" OF MATERIAL REMOVED. HFEC IAW -8400 NDTM PART 6, 51-00-01 AT BLEND. NO CRACKS NOTED.SDR QXEA2010061500353Hinge · lack of lubeMAIN CABIN DOOR HARD TO OPEN. DRAINED WATER FROM DOOR SILL AREA, CLEANED AND LUBED MCD HINGE BEARINGS. DOOR & HANDLE CK NORMAL. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2010061400349Door · bindingMCD INTERIOR LEVEL HARD TO OPERATE OPENING & CLOSING DOOR. LUBED FWD PASSENGER DOOR INTERIOR LEVEL. PERFORMED OPS TEST OF THE FWD PASSENGER DOOR IAW AMM TASK 52-11-00-710-802, OPS CHECK GOOD. PERFORMED GVI OF FWD PASSENGER DOOR, NO DEFECTS NOTED. RETURNED TO SDR CA100621012Selector Valve · leakingON FINAL APPROACH, AFTER SELECT MLG DOWN, HOWEVER THE GEAR STAYED IN UP POSITION. DUE TO INSUFFICIENT TIME TO PERFORM LANDING, MISSED APPROACH PROCEDURE HAS BEEN PERFORMED. NO NORMAL L/G EXTENSION. PERFORMED MANUAL EXTENSION ACCORDING TO EMERGENCY PROCEDURESDR QXEA2010061400348Bleed Valve · malfunctionedAT 2000' AND 180 KTS, POWER WAS SET AT ABOUT 17 PERCENT TORQUE THERE WERE 3 LOUD BANGS AND THE AIRFRAME VIBRATED. NO OTHER ANOMALIES WERE NOTED. EVENT MARKER PRESSED ABOUT 3 MINS LATER. SUSPECT NR 2 ENG. LANDING UNEVENTFUL. PERFORMED GVI OF LT AND RT MLG ASSYSSDR CA100623001Engine · vibrationSMOKE IN CABIN DURING REVENUE FLIGHT, CREW NOTED VIBRATION AND NOISE FROM LT ENGINE, FOLLOWED BY DETERIORATION OF ALL PARAMETERS AND AN IMMEDIATE SMELL OF SMOKE IN THE CABIN. THE CREW ELECTED TO SHUTDOWN THE ENGINE AND ACCOMPLISHED AN UNEVENTFUL SINGLE-ENGINESDR QXEA2010061100341Fcu · leakingLARGE FUEL LEAK FROM APU WITH APU RUNNING (ON GROUND). PLACED THE APU ON MEL 49-00-1. 6/9 MEL CLEARED BY R &R THE FCU IAW AMM 49-30-01-000-801 AND 49-30-01-400-801. OPS CHECK AND LEAK CHECKS GOOD. CLEAR MEL. RETURNED TO SERVICE.SDR QXEA2010060100328Seat Track · corrodedTOP FLANGE OF NR 15 SEAT TRACK AT FS 670 HAS CORROSION PITTING. BLENDED AREA OF CORROSION AND FOUND OUT OF LIMITS. REPLACED SEAT TRACK BY SPLICING IN NEW TRACK.SDR CA100531007Fastener · missing(CAN) DURING UNSCHEDULED MAINTENANCE, IT WAS FOUND THAT THE NLG TRAILING ARM PIN MIGRATED TO THE LEFT, DUE TO MISSING SAFETY HARDWARE. AIRCRAFT WAS REMOVED FROM SERVICE AND NEW NLG TRAILING ARM PIN AND NLG PROXIMITY SENSOR COVER WERE REPLACED. BOMBARDIER ANDSDR QXEA2010052800314Seat Track · corrodedC1 CHECK - ON RT INBD SEAT TRACK NR 12 AT APPROX STA X154-X156 THERE IS CORROSION INSIDE THE TRACK. REMOVED CORROSION BY BLENDING AND POLISHING SMOOTH. MAX MATERIAL LOSS WAS .008. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-884. ALODINED ALL BARE METAL. HFEC SDR CA100607003Wire Harness · intermittentPROP DEICE CAUTION LIGHT INTERMITTENTLY COMES ON WHEN THE NR 1 PROP HEAT ENERGIZES. WHEN THE NR 1 PROP HEAT QUITS, THE CAUTION LIGHT GOES OUT. PERFORMED EMERGENCY/ABNORMAL CHECKLIST, DIDN`T HELP. ELECTRICAL PAGE SHOWED THAT THE PROP HEAT WAS DWG A LOAD OK. SDR QXEA2010052600308Warning Light · false activationIN CRUISE, SMOOTH IMC CONDITIONS, 250 KIAS, GOT LT AND RT RED GEAR UNSAFE LIGHTS, RT AMBER GEAR DOOR LIGHT, AND GEAR HANDLE LIGHT. LIGHTS REMAINED ON FOR 10 -15 SECONDS. THEN, WENT OUT. NO FURTHER ABNORMALTIES NOTED. NO GEAR MOVEMENT NOTED. PERFORMED ALT GEASDR QXEA2010051700302Bearing · migratedMOD - BEARING ON NR 1 NACELLE FOR TOP ALTERNATE EXTENSION ACTUATOR ROD END HAS MIGRATED OUT. REPAIRED THE ALTERNATE EXTENSION ACTUATOR ATTACHMENT HOLE ON LT NACELLE TO WING SPAR ATTACHMENT FITTING IAW -8 400 RD 8/4-54-667 STEPS 1 THRU 3. PERFORMED HFEC OF RESDR QXEA2010051800305Toilet · leakingAFTER ROTATION LAV FLUID LEAKED FROM UNDERNEATH LAV DOOR. RETURNED TO THE FIELD. LANDING UNEVENTFUL. REMOVED TOILET SURROUND, CLEANED RESIDUAL FLUID, REINSTALLED SURROUND, AND SEALED WITH WHITE RTV 102. RETURNED TO SERVICE.SDR QXEA2010051800304Windshield · failedWINDSHIELD CONTROL CAUTION LIGHT. RETURNED TO FIELD, LANDING UNEVENTFUL. FOUND CIRCUIT BREAKER B6 "COPILOT - W/S PILOT - WDO HT CONT" OPEN, RESET CIRCUIT BREAKER IAW GPM 9.2.2. PERFORMED OPS TEST OF THE PILOT WINDSHIELD ANTI-ICING SYSTEM IAW AMM TASK 30-41-00SDR QXEA2010051400301Connector · contaminatedABORTED TAKEOFF BELOW 60 KTS FOR "POWERPLANT" MESSAGE. NOTICED THE MESSAGE AS WE TOOK CTRLINE AND POWER LEVERS ADVANCED JUST ABOVE FLIGHT IDLE. RETURNED TO THE GATE. INTEROGATED CDS FOUND FAULT CODES ON P-PLANT 1 CH A 14,28,30,456. CH B 794. POWERPLANT 2 CH SDR QXEA2010051100299Unknown · unknownPTU CONTROL "ON" GREEN LIGHT WILL NOT GO OUT WITH SWITCH PUSHED OUT. MECHANIC THAT TAXIED ACFT FROM GATE SAID AFTER SHUTTING DOWN NR 2 ENGINE, PTU "ON" LIGHT STAYED ON AND NR 2 HYD SYS REMAINED PRESSURIZED, LIGHT EXTINGUISHED AND ALL HYD WENT TO "0" PSI. PTUSDR QXEA2010050700295Proximity Sensor · malfunctionedNOSE GEAR DOOR LIGHT ILLUMINATED 30 SECONDS AFTER GEAR EXTENSION WITH 3 GREEN LDG GEAR LIGHTS. CAUTION LIGHT WENT OUT 20-30 SECONDS LATER ACCOMPANIED BY A FAINT BANG SOUND. LANDING UNEVENTFUL. CHECKED PSEU AND FOUND NO CURRENT FAULTS, FOUND "PSEU CHAN D FAIL 1SDR QXEA2010050700296Proximity Sensor · out of rigLT MAIN GEAR CAUTION AND WARNING (AMBER AND RED) LIGHTS CYCLED ON AND OFF 3 TIMES ON GEAR RETRACTION, BEFORE THE GEAR LIGHT PANEL WENT TO ITS NORMAL DARK CONFIGURATION. IAW PROCEDURE, GEAR WAS EXTENDED USING THE ALTERNATE GEAR EXTENSION CHECKLIST. LANDING UNEVSDR QXEA2010050400294Drain Line · rupturedRT AFTER LANDING AND DURING TAXI IN BOTH F/A AND SOME PAX NOTICED A JET EXHAUST TYPE SMELL IN THE CABIN. NO VISIBLE SMOKE OBSERVED. THE SMELL WAS NOT NOTICED IN FLIGHT BUT ON LANDING AND DURING STARTUP. THE F/O WENT TO THE BACK OF ACFT AND STATED HE SMELLED THSDR QXEA2010050300292Wire Harness · damagedNOSE GEAR DOOR CYCLED ON FINAL 2-3 TIME NO OTHER GEAR ABNORMALITY NOTICED. INTERROGATED PSEU FOR CODES- NO CURRENT FAULTS. PREVIOUS LEG SHOWED PSEU CHANNEL D FAIL - CHANNEL INOP AND NGRDRCL FAULT - UNREASONABLE FAR. C/W FIM TASK 32-61-01-810-810 AND FOUND NO SDR QXEA2010043000291Controller · malfunctionedON AFTER TAKEOFF FLOW WHEN PROPS WERE BROUGHT BACK TO 900 RPM A NOISE SIMILAR TO PROPELLER UNSYNC BEGAN AND CONTINUED. ENGINE INDICATIONS APPEARED TO BE MATCHED. NOISE DECREASED WHEN PROPS WERE BROUGHT TO 1020 ON LANDING BUT STILL OCCURED EVERY 15 SECONDS OR SSDR QXEA2010042900290Warning Light · illuminatedMASTER CAUTION PITCH TRIM, ELEVATOR FEEL LIGHTS ILLUMINATED ON TAKEOFF ROLL AT 80 KNOTS. ABORTED TAKEOFF AND RETURNED TO THE GATE. INTERROGATED CDS NO FAULTS POSTED. PERFORMED AMM TASK 27-32-00-710-802 AND TASK 27-30-00-710-801. RECHECKED CDS NO FAULTS POSTSDR QXEA2010042600288Bellcrank · damagedCAPTAINS RT BRAKE PEDAL IS LOOSE OR MISALIGNED, HAS ABNORMAL AMOUNT OF PLAY. FOUND BELLCRANK HAS ELONGATED HOLE WHERE BRAKE CONTROL ROD ATTACHES TO BELLCRANK. REMOVED PILOT SIDE RUDDER / BRAKE PIVOT SHAFT AND REMOVED DAMAGED BRAKE BELLCRANK AND REPLACED WITH NSDR QXEA2010042300284Gcu · failed"NR 2 AC GEN" CAUTION ILLUMINATED AFTER TAKEOFF. DIVERTED, LANDING UNEVENTFUL. FOUND FAULT 28 "NR 2 AC GCU FAIL" IN EPCU. R & R NR 2 AC GCU IAW AMM 24-21-06-000/400-801. OPS TEST GOOD. FAULT 28 DID NOT RETURN. INSPECTED NR 2 AC GEN CHIP DETECTOR FOR CONTAMINATSDR QXEA2010042300285Light · unsecurePLASTIC ELECTRICAL SMELL NEAR LAV AREA. FOUND UNSECURE LIGHT BAR FOR FWD LAV INFO LOOSE RESECURED AS NEEDED. RETURNED TO SERVICE. NO PARTS REPLACED.SDR NSVA201074Filter · dirtyABORTED TAKEOFF NR 1 BLEED HOT LIGHT ILLUMINATED. CLEANED FILTER AND OPS CHECK GOOD.SDR QXEA2010041900281Smoke Detector · malfunctionedELECTRICAL ODOR IN FWD BAGGAGE COMPARTMENT. R & R BAGGAGE SMOKE DETECTOR IN FWD BAGGAGE COMPARTMENT IAW AMM TASKS NR 26-12-06-000-801 AND 26-12-06-400-801. OPS CKS GOOD. NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.SDR QXEA2010041300259Door · damagedC5 CHECK - FWD BAGGAGE DOOR REQUIRES REMOVAL TO FOM STRUCTURES REPAIR. RE-INSTALLED REPAIRED FWD BAG DOOR IAW AMM TASK 52-32-00-400-801 PARA 1-4 A-F H-J. NA STEP G DUE TO AC S/N. CONTINUED INSTALL OF FWD BAG DOOR IAW AMM TASK 52-32-00-400-801 5A AND TASK 52
Back to Pratt & Whitney Canada PW150A