Pratt & Whitney JT8D-15
Service difficulty reports · 2,710
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2000UALA00673Coffeemaker · sparksCREW REPORTED SPARKS IN THE FORWARD GALLEY AND RESULTING LOSS OF POWER TO SOME LIGHTS AND HOT PLATES. SUPPLEMENTAL DATA UPDATE REPLACED COFFEE-MAKER. OP CHECKED NORMAL BY MAKING TWO POTS OF COFFEE.SDR CA001122016Engine · failed(CAN) DURING CLIMB FROM VANCOUVER THE CREW NOTICED NR 2 ENGINE OIL QUANTITY DROP TO ZERO. THEY INITIATED A PRECAUTIONARY SHUT DOWN OF THE ENGINE AND RETURNED TO VANCOUVER. MAINTENANCE PERSONNEL IN VANCOUVER FOUND NORMAL OIL QUANTITY IN THE ENGINE. THEY CARRIEDSDR DL72W002174Engine · failedENG SHUT DOWN IN FLT AFTER OIL CLOG LIGHT AND OIL TEMP RISE OF 130 DEG. FOUND METAL IN GEARBOX CHIP DET AND MAIN OIL FILTER. REPLACED NR 1 ENG.SDR 2000UALA00661Battery · failedINTERIOR EMERGENCY LIGHT ROW 20 DOES NOT OPERATE. SUPPLEMENTAL DATA UPDATE BATTERIES. -REPLACED BATTERIE S ALL OPS CHECKED GOOD.SDR 2000UALA00647Switch · looseAFT ENTRY DOOR CABIN ENTRY DOOR WARNING LIGHT ON WITH DOOR CLOSED. *S/D* FOUND MOUNTING SCREWS FOR DOOR WARNING SWITCH LOOSE. SECURED MOUNTING SCREWS AND WORKS NORMAL.SDR 2000UALA00650Stringer · corrodedFOUND CORROSION ON STRINGER 21R AT BODY STATION 360. CORROSION ALSO ON INNER SIDE OF SKIN. STRINGER IS IN THE AREA OF STATIC PORT. *S/D* REPLACED CORRODED STRINGER WITH NEW HAT SECTION FABRICATED FROM HAT SECTION RAW STOCK. REF SRM 53-10-03 FIG 1.SDR 2000UALA00641Motor · leakingDIVERTED TO DEN DUE TO THE LOSS OF THE A-SYSTEM HYDRAULIC FLUID. *S/D* FOUND OUTBOARD FLAP DRIVE HYD MOTOR LEAKING. REPLACED OUTBOARD FLAP HYD DRIVE MOTOR. NO ACTIVE LEAKS NOTED ON FLAP CYCLING. SERVICED HYDRAULIC SYSTEM.SDR 2000UALA00646Pump · failedDIVERTED TO IAD DUE TO LOSS OF A-SYSTEM HYDRAULICS. REPLACED NR 1 ENGINE HYDRAULIC PUMP.SDR 2000UALA00639Transmission · failedON FLAP RETRACTION AFTER LANDING INBOARD TRAILING EDGE FLAPS STUCK AT 2 DEGREES. OUTBOARDS RETRACTED UP GENERATING SPLIT FLAPS. CYCLED FLAPS WITH SAME RESULTS. *S/D* FOUND RIGHT I/B FLAP TRANSMISSION BAD. REPLACED TRANSMISSION. OPS CHECK OK.SDR 2000UALA00640Engine · malfunctionedOVER BOOSTED ALL THREE ENGINES ON LANDING. FLAMES SEEN FROM NR 2 AND 3 ENGINES. LARGE EPR FLUCTUATIONS ON NR 2 AND 3 ENGINES. EPR ON LANDING NR 1 = 2.08, NR 2 = 2.04 TO 2.11 AND NR 3 = 2.01 TO 2.08. THIS EPR DATA WAS ON LANDING IN REVERSE. SUPPLEMENTAL DATA UPSDR 2000UALA00642Line · leakingA-SYSTEM HYDRAULIC FLUID WENT FROM 3.5 TO 1.0 GAL. THE SYSTEM WAS ISOLATED, A-PUMPS OFF. *S/D* FOUND LINE TO A SYSTEM PRESSURE TRANSMITTER LEAKING. MANUFACTURED AND INSTALLED REPLACEMENT HYDRAULIC LINE. PRESSURE CHECK OK.SDR 2000UALA00615Battery Pack · failedOVERWING CEILING EMERGENCY LIGHT AT ROW 9 INOPERATIVE. *S/D* REPLACED BATTERY PACK, OPS CKS GOOD.SDR DL72W002093Engine · leakingOIL QUANTITY ON NB 3 ENGINE DECREASING AT A RATE OF APPROX 1 QUART EVERY 15 MINUTES. ADDED 18 PINTS OF OIL TO NR 3 ENGINE. FOUND OIL LINE LEAKING. REPLACED BOTH O-RINGS, ITEM 75 AND 40 IPC 79-20-00-20 NR 4, 5 AND 6 BREATHER LINE.SDR 2000UALA00607Limit Switch · malfunctionedABORTED TAKEOFF AT APPROXIMATELY 80 KNOTS DUE TO FORWARD ENTRY DOOR WARNING LIGHT. *S/D* AIRCRAFT HISTORY INDICATED AMT CYCLED FWD ENTRY DOOR SEVERAL TIMES AND SWITCH CHECKED GOOD. AS PRECAUTIONARY MEASURE, EG2110 CALL OUT WAS INITIATED TO ACCOMPLISH THE FOSDR USAASB00298Duct · crackedLGA-MCO - FLT 2667 - DURING CRUISE, THE RIGHT ENGINE OVERHEAT LIGHT ILLUMINATED. THE LIGHT WENT OUT WHEN THE ENGINE POWER WAS REDUCED. THE AIRCRAFT DIVERTED TO BWI AND LANDED WITHOUT INCIDENT. NO EMERGENCY WAS DECLARED AND NO ENGINE SHUTDOWN OCCURRED. MAINSDR DL72S002028Engine · bird strikeDURING TAKEOFF, A/C SUFFERED BIRD STRIKE, FODDING OUT NR 1 ENGINE. REPLACED ENGINE.SDR 2000UALA00594Light · intermittentOPERATIONS REPORTED THAT WHEN REMOVING POWER FROM THE AIRCRAFT THE FORWARD EMERGENCY LIGHT REMAIND ON AND CYCLING OF EMERGENCY LIGHTS DID NOT HELP. *S/D* RESET LIGHT AT LIGHT ASSEMBLY, OPS CHECK NORMAL.SDR CA001103019Stator · broken(CAN) NR 2 BRAKE FOUND DAMAGED DURING MAIN WHEEL ASSEMBLY (WORN TO LIMITS) REPLACEMENT. BROKEN PIECE FELL OUT ONTO GROUND. REF. ATTACHED PICTURE. NR 2 BRAKE WAS REPLACED AND THE AIRCRAFT RETURNED TO SERVICE.SDR DL73K002013Engine · inoperativeOIL FILTER BYPASS LIGHT ON AFTER TAKEOFF. NR 1 ENG SHUT DOWN. RETURNED TO MCI. OIL PRESSURE WAS NORMAL WHILE ENGINE RUNNING. ENGINE WINDMILLED ABOUT 30 MIN. METAL FOUND IN MAIN FILTER AND GEARBOX CHIP DETECTOR. REPLACED NR 1 ENGINE PER CARD DECK 3T213.SDR 2000UALA00593Line · failedHYDRAULIC SYSTEM A QUANTITY GAUGE INDICATED SLOW PARTIAL LOSS OF FLUID. DECREASED APPROXIMATELY 1 GALLON IN 2 HOURS. DIVERTED TO DEN, LANDED UNDER AMBER ALERT. TOWED TO GATE DUE TO NO NOSE GEAR STEERING. *S/D* FOUND RIGHT HAND GEAR DOOR ACTUATOR LINE LEAKSDR 2000UALA00726Structure · damagedDUE TO GROUND EQUIPMENT IMPACT, STRINGER 22R BUCKLED BETWEEN BS 302.5 & 334.5. BS 328 FRAME WEB & SAFE CHORD BUCKLED & CRACKED ALONG A 13 INCH SECTION ADJACENT TO STRINGER 22R. FUSELAGE SKIN PUNCTURED & CRACKED LENGTHWISE BETWEEN BS 301 & 341 & CIRCUMFERENTISDR 2000UALA00608Frame · buckledON OCTOBER 11 A CART COLLIDED WITH THE AIRCRAFT. IT MADE A HOLE IN THE AIRCRAFT FOUR FEET AFT OF THE AC POWER PLUG. THE BS 328 FRAME WEB AND FAIL-SAFE CHORD WERE BUCKLED AND CRACKED ALONG A 12 INCH SECTION ADJ TO STRINGER 22R. THE FUSELAGE SKIN WAS PUNCTURESDR 2000UALA00589Actuator · malfunctionedON DEPARTURE FROM PVD, NR 2 LEADING EDGE SLAT REMAINED IN THE EXTENDED POSITION. DIVERTED TO BOSTON. *S/D* FOUND FAILED TAI TELESCOPING DUCT AND RESULTING DAMAGE TO NR 2 L/E SLAT. REPLACED FAILED DUCT AND NR 2 L/E SLAT ASSY PER MAINTENANCE MANUAL. SYSTEMSDR 2000UALA00585Light · failedEEL STRIP INOPERATIVE FROM ROW 16 T0 24. *S/D* REPLACED FEEDER CABLE AT ROW 22. GROUND TEST EEL NORMAL.SDR DL72L002083Flange · bentAT HMV, THE AFT FLANGE OF THE NR 2 INLET WAS TORN/BENT. REMOVED DAMAGE PER SRM 54-10-3D FIG 801D. DYE CKED, NO FURTHER DAMAGE NOTED. FABRICATED REPAIR PARTS AND INSTALLED PER SRM 54-10-3D FIG 801D.SDR 2000UALA00581Relay · failedEMERGENCY FLOOR STRIP EEL LIGHT AND OVERHEAD LIGHTS AS WELL FLICKERS ON AND OFF INTERMITENTLY. *S/D* REPLACED RELAYS R70, R600 AND AFT EMERGENCY EXIT LIGHT SWITCH.SDR CA001016011Bolt · missing(CAN) CREW REPORTED ON TAXI OUT WHEN THEY CHECKED THE FLIGHT CONTROLS THE ELEVATOR FELT VERY RESTRICTED IN DOWN TRAVEL MOTION. OPERATION FELT NORMAL WITH A SYSTEM HYDRAULIC DEPRESSURIZED. UPON INVESTIGATION FOUND A SYSTEM ELEVATOR PCU INPUT ROD TO ELEVATOR INPSDR 20001113SH017Valve · failedSAI/BZE - FLT TA410 - DURING CRUISE, RIGHT ENGINE COWL VALVE FAILED IN THE OPEN POSITION AND THE LIGHT REMAINED ILLUMINATED. THE AIRCRAFT RETURNED TO EL SALVADOR STATION FOR MAINTENANCE. AT EL SALVADOR STATION, MAINTENANCE TECHS PERFORMED INSPECTION OF THE ESDR 20001012SH001Pin · damagedSAL/TGU - FLT TA211 - DURING CRUISE STAGE FLIGHT, THE THRUST REVERSER NR 2 ISOLATION VALVE LIGHT CAME ON. ACFT RETURNED FOR MAINT. UPON LANDING, THE LIGHT WENT OFF AND THRUST REVERSER WORKED NORMALLY. AFTER UNEVENTFUL LANDING, MAINT TECHS PERFORMED INSPECSDR 2000UALA00557Actuator · leakingON TAKEOFF THE OUTBOARD FLAPS WOULD NOT RETRACT BEYOND POSITION 2. RETURNED TO ORD. ON APPROACH TO GATE SYSTEM A HYDRAULIC FLUID QUANTITY WENT TO ZERO. *S/D* REPLACED NR 5 RIGHT WING MIDDLE KRUEGER FLAP ACTUATOR PER MAINTENANCE MANUAL. SERVICED HYDRAULIC SDR CA001103010Fitting · cracked(CAN) CRACK DETECTED VISUALLY IN WEB OF RIGHT ARM OF THE NR 1 ENGINE FORWARD MOUNT FITTING. THE ENGINE WAS REMOVED TO FACILITATE LAP JOINT MODIFICATION AND REMOVAL TASK CARD CALLS FOR INSPECTION OF ALL ENGINE MOUNTS.SDR 2000UALA00554Battery · failedOVERHEAD EMERGENCY LIGHT AT SEAT ROW 1 IS INOPERATIVE. *S/D* REPLACED BATTERY PACK.SDR 2000UALA00555Power Supply · failedSMOKE LIKE SMELL DETECTED IN CABIN. *S/D* DURING CHECK OF PASSENGER CABIN LIGHTING, MAINTENANCE FOUND AFT SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. THE POWER SUPPLY AND BATTERIES WERE REPLACED. NO OTHER PASSENGER CABIN LIGHTING OR ELECTRICAL SYSTEM DEFECTSSDR DL72K001788Helicoil · backed outNR 1 ENG WAS SHUT DOWN DURING CRUISE DUE TO ZERO OIL QTY AND LOW OIL PRESSURE. OCCURRED AT FL 200 WHEN WE LEVELED OFF. FOUND BUSHING/HELICOIL PULLED OUT OF GEARBOX AT LP6 DRAIN TUBE ABOVE OIL FILTER. REPLACED SAME, RAN ENGINE PER PFHB CKS GOOD.SDR 2000UALA00551Battery Pack · failedRIGHT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. *S/D* REPLACED BATTERY PACK.SDR 2000UALA00548Duct · rupturedCREW SHUT DOWN THE NR 3 ENGINE AND RETURNED TO IAD DUE TO NR 3 ENGINE FIRE BELL AND LIGHT INDICATION AT 1500 FEET. *S/D* MAINTENANCE FOUND Y DUCT BETWEEN 13TH STAGE AND TAI BLOWN. Y DUCT WAS REPLACED. ACCOMPLISHED ENGINE RUN WITH NO FAULTS FOUND.SDR 2000UALA00549Lead · failedEEL STRIP BLINKING AT SEAT 27. *S/D* REPLACED POWER LEAD CABLE DUE TO ARCING AT STRIP CONNECTION.SDR 2000UALA00534Oven · overheatedFORWARD GALLEY HAD STRONG SMELL OF BURNING SUBSTANCE. OPENED CARRIER FOR FOOD AND TRAYS WERE EXTREMELY HOT AND CARDBOARD COVERS WERE BURNT. GALLEY POWER TURNED OFF. *S/D* AMIS HISTORY INDICATES GALLEY FOOD CARRIER WAS REPLACED ON 07 SEPT. NO FURTHER PROBLSDR 2000UALA00535Heater · failedRETURNED TO IAD DUE TO SMOKE IN COCKPIT FROM CAPTAINS OVERHEAD PANEL AFT OF NR 4 EYEBROW WINDOW. *S/D* MAINTENANCE REPORTED FINDING CAPT''S NR 4 EYEBROW WINDOW ARCHING AT TERMINALS. CAPT''S NR 4 WINDOW WAS REPLACED. SHOP FINDINGS CONCUR, EVIDENCE OF ARCHINSDR 0003279984Fuel Control · inoperativeDURING CLIMBOUT FROM MSP, THE RIGHT ENGINE EXPERIENCED SURGES AND FLUCUATING ENGINE PARAMETER READINGS. THE FLIGHT CREW FOLLOWED COM PROCEDURES, RETURNED TO MSP, AND LANDED WITHOUT INCIDENT. AN EMERGENCY WAS DECLARED ON APPROACH TO LANDING DUE TO RIGHT ENGINSDR AU000859Skin · corroded(AUS) LOWER CENTRE LINE FUSELAGE SKIN CORRODED AT STN 360. FOUND DURING CORROSION INSPECTION.SDR AU000860Spar · corroded(AUS) REAR SPAR UPPER CHORD CORRODED AT UPPER SKIN INTERFACE INBOARD OF NR 4 SPOILER INBOARD HINGE. FOUND DURING CORROSION INSPECTION.SDR EISA20000133Bleed Valve · looseON CLIMBOUT, NR 3 ENGINE STRUT OVERHEAT LIGHT ILLUMINATED. RAN CHECKLIST AND HAD NR 3 BLEED VALVE CLOSED AND NR 2 RT BLEED VALVE OPEN TO RESTORE NORMAL OPERATION. FOUND IN NR 3 STRUT LOOSE FASTENERS ON BLEED VALVE. TIGHTENED PER M/M 77 STANDARD PRACTICES, OSDR AU000855Keelbeam · corroded(AUS) KEEL BEAM WEB CORRODED AT STN 950 LOCATED IN THE UPPER AFT CORNER OF THE LT WHEEL WELL. FOUND DURING CORROSION INSPECTION.SDR AU000856Web · corroded(AUS) UPPER WEB LOCATED IN THE LT UPPER WHEEL WELL AT STN 870 BETWEEN WBL 0 AND WBL 24.75 CORRODED. FOUND DURING CORROSION INSPECTION.SDR AU000857Fitting · corroded(AUS) SPLICE FITTING LOCATED BETWEEN STN 870 FORGING AND HORIZONTAL BEAM LOCATED IN LT WHEEL WELL CORRODED. FOUND DURING CORROSIONINSPECTION.SDR AU000858Angle · corroded(AUS) BULKHEAD T' ANGLE LOCATED IN RT WHEEL WELL AT STN 950 CORRODED AT KEEL BEAM ATTACHMENT. FOUND DURING CORROSION INSPECTION.SDR AU000861Spar Cap · corroded(AUS) REAR SPAR CAP CORRODED AT UPPER SKIN INTERFACE ADJACENT TOOUTBOARD FLAP OUTBOARD JACKSCREW GEARBOX. FOUND DURING CORROSIONINSPECTION.SDR 2000UALA00527Switch · failedFLIGHT RETURNED TO ORD AFTER LOSS OF BOTH FORWARD AND AFT RIGHT BOOST PUMPS IN THE CENTER TANK. *S/D* PROBABLE CAUSE: BOOST PUMP SWITCHES. REPLACED NR 2 TANK FWD AND AFT BOOST PUMP SWITCHES.SDR 2000UALA00520Coffeemaker · arcedFLIGHT ATTENDANT OBSERVED ARCING AND SPARKING IN THE AREA AFT OF THE COFFEEMAKER IN THE FORWARD GALLEY. *S/D* AMIS HISTORY INDICATES CIRCUIT BREAKERS WERE CYCLED AND RETESTED. MAINTENANCE CREW COULD NOT DUPLICATE PROBLEM. ALL HOT PLATES AND COFFEE POTS OPE
Back to Pratt & Whitney JT8D-15