SDR 2000UALA00519Battery · failedDOOR R1 EMERGENCY LIGHT INOPERATIVE INCIDENT 6112001. DOOR R4 OVERWING EMERGENCY LIGHT OUT INCIDENT 6112002. *S/D* REMOVED AND REPLACED BATTERY.SDR 2000UALA00518Light · failedEMERGENCY EXIT LIGHT AT DOOR 1L WILL NOT TURN OFF. *S/D* REPLACED POWER PACK AND BATTERY, OPS CHECK GOOD.SDR CA000907006Position Switch · failed(CAN) FAILED NLG POS IND. SWITCH YIELDED FOLLOWING RESULTS. CURSORY INSP DETECTED INTERNAL RATTLE. WHEN CASE OPENED LOOSE DRIVE SCREW & SLEEVE (THIMBLE) WHICH COMPRISE SWITCH ARM SPRING ANCHOR ASSY WERE FOUND. THE CONTACTOR ASSY APPEARED TO BE IN AS NEW CONDITSDR 2000UALA00512Controller · malfunctionedUNABLE TO MAINTAIN CABIN PRESSURE ABOVE 18,000 FEET. TOTAL FUEL ON BOARD WAS NOT ENOUGH TO CONTINUE TO ORD. DIVERTED TO IND. *S/D* INDIANAPOLIS MAINTENANCE PERFORMED A CABIN PRESSURIZATION SYSTEM TEST AND SYSTEM WAS CLEARED AS CHECKED OK, NO DISCREPANCIES SDR 2000UALA00495Hose · leakingABOUT 5 TO 10 MINUTES OUT OF DEN AIRCRAFT LOST ''B'' HYDRAULIC SYSTEM. LANDED UNDER AMBER ALERT. *S/D* REPLACED ''B'' SYSTEM PUMP PRESSURE LINE TO PRESSURE MODULE. ALSO CHANGED RETURN FILTERS. SERVICED HYDRAULIC FLUID TO FULL. PRESSURE CHECKED OK, NO LSDR 2000UALA00494Actuator · splitON INITIAL MOVEMENT OF THE FLAP HANDLE TO 2 ON APPROACH, HYDRAULIC SYSTEM ''A'' QUANTITY AND PRESSURE WENT TO ZERO. *S/D* FOUND NR 6 SLAT ACTUATOR SPLIT AT AFT UPPER CYLINDER. REPLACED ACTUATOR PER MAINTENANCE MANUAL. SERVICED HYDRAULIC SYSTEM, OPERATIONASDR 2000UALA00482Seal · leakingUNABLE TO MAINTAIN CABIN PRESSURE IN ANY MODE. DESCENDED TO 15000 FEET AND CONTINUED TO DCA. *S/D* LEAK IN THE AFT CARGO SILL SEAL. ACCOMPLISHED TIME LIMITED REPAIR TO SEAL AND CREATED ITEM TO REPLACE SEAL AT NEXT B CHECK.SDR 2000UALA00484Battery · failedTHE EMERGENCY EXIT LIGHT ABOVE THE REAR ENTRY DOOR DOES NOT LIGHT. *S/D* REPLACED BATTERIES, OPERATIONAL CHECK OK.SDR 2000UALA00483Cover · missingEMERGENCY EXIT FLOOR STRIP AT AFT LEFT DOOR IS MISSING ORANGE 2 FOOT STRIP. *S/D* REPLACED ORANGE STRIP, GROUND CHECKS NORMAL.SDR RIVA0000022Shaft · shearedTHE NR 3 ENGINE FAILED APPROXIMATELY 400 FEET ABOVE GROUND LEVEL. ON RETURN TO PIT, THE NR 1 TIRE BLEW. METAL WAS FOUND IN THE FUEL PUMP FILTER. THE FUEL PUMP AND FUEL CONTROL UNIT WERE REMOVED AND REPLACED. THE NR 1 AND NR 2 TIRES WERE REMOVED AND REPLACESDR 2000UALA00460Relay · failedAT DEPARTURE TIME CREW REPORTED EMERGENCY EXIT LIGHTS WOULD NOT EXTINGUISH. *S/D* REPLACED RELAY R70, LIGHTS OPS NORMAL.SDR 2000UALA00442Elbow · crackedUNCOMMANDED FUEL BURN FROM THE NR 1 AND NR 3 TANKS WHILE USING FUEL FROM THE NR 2 TANK. *S/D* NR 3 TANK VENT TUBE FOUND CRACKED. REPLACED VENT TUBE.SDR 2000UALA00444Heat Exchange · leakingSHUTDOWN NR 2 ENGINE. SUSPECTED FUEL / OIL HEAT EXCHANGER LEAKING FUEL INTO THE OIL SYSTEM. CAPTAIN DECLARED AN EMERGENCY AND DIVERTED TO DTW. *S/D* FUEL-OIL COOLER LEAKING. REPLACED FUEL-OIL COOLER.SDR DL73K001380Valve · leakingAIRCRAFT TAKEOFF ABORTED AT 120 KIAS. NR 1 ENGINE EGT GOING THROUGH 625 CELSIUS. PEAK TEMP OBSERVED 628 - 629 CELSIUS. PACKS OFF T/O. FOUND NR 1 ENG NOSE COWL ANTI-ICE VLV BYPASSING BLEED AIR. REMOVED AND REPLACED NOSE COWL ANTI-ICE VLV PER MM. PERFORMEDSDR 2000UALA00443Light · failedEMERGENCY EXIT LIGHT OVER DOOR 1L COMES ON WHEN EMERGENCY EXIT LIGHTS ARE ARMED. *S/D* REPLACED EMERGENCY EXIT LIGHT ASSY PER MM 33-50-12.SDR 2000UALA00437Indicator · failedWHEN FUELING PANEL OPENED AND POWER ON, SMOKE AND SPARKS ERUPTED. *S/D* REPLACED NR 2 TANK IN TRANSIT INDICATOR LIGHT ASSEMBLY.SDR 2000UALA00438Battery · failedEMERGENCY LIGHT AT AFT ENTRY DOOR INOPERATIVE. *S/D* REPLACED BATTERIES.SDR 2000UALA00439Access Panel · looseCREW REPORTED A FUEL LEAK AND FLIGHT RETURNED TO ORD. REQUESTED FIRE EQUIPMENT. TOWED TO GATE. *S/D* FUEL ACCESS PANEL 7216 WITH MISSING AND UNDERTORQUED FASTENERS. REPLACED AND RETORQUED ALL FASTENERS.SDR DL72S001342Csd · failedNR 2 GENERATOR CIRCUIT BREAKER TRIPPED IN FLIGHT, NR 2 CSD IN TEMP IN CAUTION RANGE, VOLTS AND FREQS NORMAL. NR 1 GENERATOR ALREADY ON MCO. REPLACED CSD, GENERATOR, AND CSD OIL COOLER. ALL OPERATION AND LEAK CHECKS NORMAL.SDR 2000UALA00425Oven · shortedGALLEY OVEN SMOKING AND SPARKING. *S/D* SMOKING AND SPARKING AFT GALLEY OVEN WAS REPORTED. POWER WAS REMOVED. LOG WRITE-UP NOTES IT APPEARS TO BE HOT PLATE. THIS ITEM IS RELATED TO MRR 2000UALA000000365 (DF 106 ON THIS SAME AIRCRAFT. COFFEEMAKER SMOKING SDR 2000UALA00426Csd · failedAFTER TAKEOFF, NR 3 GENERATOR FREQUENCY WENT TO 420 AND BUS 1 AND 2 TRIPPED WITH OVEREXCITE INDICATION. DECLARED AMBER ALERT AND RETURNED TO TUL. *S/D* REPLACED NR 3 GENERATOR AND CSD. GENERATOR SYSTEM OPERATIONAL CHECK NORMAL. GENERATOR P/N MR24214 (976JSDR 2000UALA00418Light · failedOVERHEAD EMERGENCY LIGHT IN COCKPIT WILL NOT SHUTOFF. *S/D* REPLACED EMERGENCY LIGHT ASSEMBLY.SDR DL72K001310Engine · flamed outNR 2 ENGINE FLAMED OUT ON LANDING. REPLACED ENGINE.SDR 2000UALA00415Battery Pack · inoperativeINTERIOR EMERGENCY EXIT LIGHTS BOTH FORWARD AND AFT RIGHT HAND OVERWING DOORS ARE INOPERATIVE. *S/D* BATTERY PACK AND BATTERY CARTRIDGE AT STATION 800,OPERATIONAL CHECK OK.SDR DL72W001305Engine · failedON CLIMB, NR 3 ENG HAD VIBRATION, LOUD BANG, AND LOSS OF THRUST. NO FIRE WARNING. REPLACED NR 3 ENGINE.SDR DL73K001264Panel · missingUPON ARRIVAL FOUND 01 O/B PYLON PANEL 5126L MISSING. REPLACED SAME.SDR 2000UALA00398Wire · failedEEL LIGHTS ON FLOOR FROM ROW 18 TO ROW 24 ARE INOPERATIVE. *S/D* REPAIRED EEL LIGHTING PIG TAIL AT ROW 22 LEFT. SYSTEM CHECKS OK.SDR DL72E001261Warning System · false activationTEN MINS PRIOR ARRIVAL LEX, HAD NR 2 ENG FIRE WARN. NR 2 ENG F/W A LOOP ON MCO. SHUTDOWN ENG PER POM. FIRED BOTH BOTTLES. LIGHT DID NOT GO OUT. LIGHT WENT OUT 2 MINS PRIOR LANDING. DECLARED EMERGENCY, NO FIRE CONFIRMED BY GROUND EQUIP. REPLACED FWD AND SDR 00FDEA00420Drain Line · crackedDURING ROUTINE INSPECTION, NR 3 ENGINE PS 4 DRAIN BOSS FOUND CRACKED. R&R NR 3 ENGINE PER IAW FEDEX WORK CARD 70T0001-03SDR 00FDEA00421Case · crackedDURING ROUTINE INSPECTION, THE NR 3 ENGINE INLET GUIDE VANE CASE WAS FOUND CRACKED. R&R NR 3 ENGINE IAW FEDEX WORK CARD 70T0001-03.SDR 2000UALA00374Connector · failedAPU GENERATOR INOPERATIVE AT DISPATCH. PHASE INBALANCE THEN ZERO VOLTS ON GENERATOR. *S/D* MAINTENANCE FOUND BURNT CONTACTS IN THE APU FEEDER CABLE CONNECTORS D4688P&J. CONNECTORS AND ASSOCIATED WIRING WERE REPLACED AND GENERATOR SYSTEM OPERATIONAL CHECKSNSDR 2000UALA00372Battery · failedEMERGENCY EXIT LIGHT ABOVE DOOR 1R INOPERATIVE. *S/D* REPLACED BATTERIES ABOVE DOOR 1R. OPERATIONAL CHECK NORMAL.SDR 2000UALA00373Battery Pack · failedBOTH AFT DOORS EMERGENCY SLIDE LIGHTS ARE INOPERATIVE. *S/D* REPLACED BATTERY PACK.SDR 2000UALA00370Fan · failedRETURNED TO GATE WITH SMOKE IN THE CABIN. *S/D* FOUND PACK COOLING FAN INOP. REPLACED COOLING FAN.SDR 2000UALA00365Coffeemaker · shortedAFT LOWER COFFEEMAKER SMOKING AND SPARKING. *S/D* AFT GALLEY DRAIN TRAY FOR M42 COFFEEMAKER PLUGGED CAUSING WATER TO DRIP ONTO M41. THIS CAUSED EXCESSIVE STEAM TO EMIT FROM M41 COFFEEMAKER. THIS ITEM IS RELATED TO MRR 2000UALA000000425 (DF 108 ON THIS SSDR 2000UALA00356Slide · tornDURING SHOP OVERHAUL OF EVACUATION SLIDE A MASSIVE FABRIC FAILURE WAS SUSTAINED AT THE RELIEF VALVE ASSEMBLY WHILE INFLATING UNIT TO PROOF PRESSURE. UNIT FAILED AT ABOUT 3.50 PSI. SLIDE ASSEMBLY SENT TO VENDOR FOR INVESTIGATION OF FAILURE AND WARRANTY REPAIRSDR 2000UALA00363Coalescer Bag · dirtySLIGHT ODOR OF BURNING RUBBER AND OIL ALONG SEAT ROW 22. RUBBER SMELL STRONGER THAN THE OIL. CANNOT SMELL IT AT ROWS 21 OR 23. *S/D* FOUND DIRTY COALESCER BAGS, EVIDENCE OF OIL DEPOSITS ON BAG. REPLACED BOTH PACKS WATER SEPARATOR BAGS.SDR 2000UALA00361Engine · overtempSTICK SHAKER WENT OFF AT V2. CREW FIREWALLED ALL 3 ENGINES FOR MAXIMUM EGT NR 1-675, NR 2-675, NR 3-700. THROTTLES AT THIS POSITION FOR 10 SECONDS. *S/D* REPLACED NR 2 ENG PER MM 71-00-04. REPLACED NR 1 ENG PER MM 71-00-03, AND REPLACED NR 3 ENG PER MM 7SDR 2000UALA00362Fuel Cell · overservicedABORTED TAKEOFF AT 120 KNOTS DUE TO AIRCRAFT VENTING FUEL FROM NR 1 TANK. *S/D* MAINTENANCE SUSPECTED TOO MUCH FUEL WAS PUT IN NR 1 TANK. DRIPPED TANK AND TRANSFERRED EXCESS FUEL.SDR DL72W001180Fuel Heater · intermittentNR 1 ENG FUEL HEAT VLV INTRANSIT LIGHT ILLUMINATED AFTER TAKEOFF. OIL TEMP IND HIGH. ACCOMPLISHED POM PROCEDURE. LIGHT REMAINED ON AND TEMP HIGH. WHEN FUEL DUMPING WAS STARTED THE LIGHT WENT OUT AND TEMP RETURNED TO NML. REPLACED NR 1 ENG FUEL HEAT VLV, OSDR CA000712011Cylinder · cracked(CAN) DURING WALK AROUND, AIRCRAFT HYDRAULIC FLUID WAS NOTICED COMING FROM THE LEFT HAND WHEEL WELL. FURTHER INVESTIGATION FOUND THE FLUID WAS LEAKING FROM A CRACK IN THE MAIN LANDING GEAR TRANSFER CYLINDER. THE TRANSFER CYLINDER ASSY WAS REPLACED AND THE AIRSDR 2000UALA00344Battery Pack · failedAISLE OVERHEAD EMERGENCY LIGHT AT ROW 3 IS DIM. *S/D* REPLACED BATTERY PACK.SDR C8GA200000004Pump · inoperativeFLT 216 KDAY-KHSV WITH ENG POWER SET AT REDUCED TAKEOFF POWER SETTING OF 2.0 EPR AND 95 PERCENT N1 NR 1 ENG WENT TO 2.4 EPR, RETARDED THROTTLE AND EPR QUICKLY DROPPED TO 1.8. TRIED TO RESET POWER AND NO EPR RESPONSE TO THROTTLE MOVEMENT OCCURRED. ABORTED TAKSDR DL72K001172Engine · flamed outAPROX 20 SECONDS AFTER TAKEOFF NR 1 ENGINE FLAMED OUT WITH NO OTHER ABNORMAL INDICATIONS OR SOUNDS NOTED BY FLIGHT CREW. REPLACED NR 1 ENGINE DRIVEN FUEL PUMP AND FUEL CONTROL UNIT PER MM. RAN AND ADJUSTED NR 1 ENGINE FUEL CONTROL PER PFHB AND MM, ALL PARAMESDR 2000UALA00341Light · failedEMERGENCY EXIT LIGHT ABOVE AFT ENTRY DOOR IS INOPERATIVE. *S/D* ITERIM REPAIR ON EMERGENCY LIGHT BATTERY PACK.SDR 2000UALA00337Light · failedEMERGENCY EXIT LIGHT CENTER CABIN INOPERATIVE. *S/D* OVERHEAD EMERGENCY LIGHT ASSEMBLY. REPLACED OVERHEAD EMERGENCY LIGHT ASSEMBLY CENTER AISLE AT ROW 9, OPS GOOD.SDR 2000UALA00330Wire · brokenFOUND SEVERAL EMERGENCY EEL STRIPS INOPERATIVE BETWEEN ROWS 17 ABC THROUGH 25 ABC AND AT ROW 12 ABC. ALSO, EMERGENCY EXIT LIGHT AT DOOR L1 INOPERATIVE. *S/D* BROKEN WIRES. REPAIRED WIRES AT VARIOUS LOCATIONS USING THE EEL STRIP SPLICE KIT WHICH IS A PERMANSDR 2000UALA00331Power Supply · failedDOOR 2L EMERGENCY EXIT LIGHT INOPERATIVE. *S/D* REPLACED BATTERY AND CHARGER IN AFT GALLEY CEILING.SDR 2000UALA00329Power Supply · failedRIGHT HAND AFT OVERWING EXIT LIGHT INOPERATIVE. *S/D* POWER SUPPLY AND BATTERY PACK. REPLACED POWER SUPPLY AND BATTERY PACK.SDR 2000UALA00321Coalescer Bag · contaminatedRETURNED TO DEN DUE TO SMOKE IN COCKPIT AND CABIN. *S/D* SUSPECT OVERSERVICING OF A SYSTEM HYDRAULIC RESERVOIR. DRAINED EXCESS FLUID FROM RESERVOIR AND REPLACED WATER SEPARATOR COALESCER BAG AS PRECAUTIONARY.
Back to Pratt & Whitney JT8D-15