Pratt & Whitney JT8D-15
Service difficulty reports · 2,710
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL72S001083Engine · stalledDURING TAKEOFF ROLL FLT ATTENDANT AND PASSENGER REPORTED HEARING COMPRESSOR STALL NR 3 ENG. NO ABNORMAL ENGINE INDICATIONS WERE NOTICED. INSPECTED INTAKE AND EXHAUST, CHECKED GOOD. RAN ALL THREE ENG''S TO TAKEOFF PWR PER PFHB. ALL CHECKED GOOD. WINDSSDR 2000UALA00314Relay · failedEMERGENCY EXIT LIGHTING CAME ON. RECYCLED POWER FAILURE CIRCUIT BREAKER AND LIGHTS WENT OUT. *S/D* REPLACED R70 POWER FAIL RELAY. OPERATIONAL CHECK OK.SDR DL73E001071Engine · fodON TAKEOFF, HEARD LOUD BANG. SUSPECT BIRD STRIKES. FOUND NR 2 ENG 1ST STAGE FAN BLADE FOD. REPLACING FAN.SDR L1GA200000130Pump · failedACFT ABORTED TO NR 1 ENGINE POWER REDUCED TO 80 PERCENT N2 W/O THROTTLE INPUT. NR 1 ENGINE FUEL PUMP REPLACED.SDR 2000UALA00289Battery Pack · failedFORWARD ENTRY DOOR EXTERIOR EMERGENCY LIGHTS INOPERATIVE. *S/D* REPLACED BATTERY PACK AND BATTERY.SDR DL72S001004Oil Cap · leakingEN ROUTE NR 2 ENG SHUTDOWN DUE OIL QTY WENT DOWN TO ZERO WITH DECREASING OIL QTY. LOW OIL PRESS LIGHT ILLUM. SHUTDOWN PER POM. FOUND LEAK AT OIL CAP. REPLACED SAME.SDR DL72S000996Engine · malfunctionedDURING CLIMBOUT, NR 2 EPR BEGAN TO ROLL BACK FOLOWED BY N2. RESTORED ENG TO IDLE. ALL INDICATIONS NORMAL. TRIED TO ADVANCE POWER, ENGINE WOULD NOT ACCELERATE. SHUT DOWN ENGINE PER POM. REPLACED P&D VALVE.SDR DL72S000991Wire · brokenNUMBER 3 OIL TEMP WAS FLUCTUATING UP TO THE UPPER PEG. OIL QTY WAS SLOWLY DECREASING TO 1.4, OIL PRESS WAS NORMAL AT 50 PSI. ENG WAS SHUTDOWN IN FLT. ALL OTHER PARAMETERS WERE NORMAL. FOUND BROKEN WIRE AT CANNON PLUG TO OIL TEMP TRANSMITTER. REPAIRED BRSDR 2000UALA00281Switch · failedAFTER TAKEOFF CREW RECEIVED INDICATION OF TRAILING EDGE OUTBOARD FLAP POSITION NR 2 EXTENDED. FOLLOWED PROCEDURE TO RETRACT FLAPS USING ALTERNATE METHOD AND ALL RETRACTED NORMALLY. *S/D* REPLACED NEW SWITCH AND HARNESS ASSEMBLY AND THE SYSTEM OPERATIONALLY SDR 2000UALA00263Switch · failedLEADING EDGE SLAT LIGHT STAYED AMBER TRANSITIONING SLAT 5 TO 2. SLAT APPEARS RETRACTED. RETURNED TO ORD. *S/D* REPLACED NR 1 LEADING EDGE SLAT SWITCH.SDR 2000UALA00260Unknown · odorABORTED TAKEOFF AT 70 KNOTS DUE TO SMELL OF SMOKE IN CABIN. (SMELL LIKE BURNING PAPER). AT THE SAME TIME NR 1 PACK TRIP LIGHT ILLUMINATED. *S/D* PROBABLE CAUSE MAY BE AN OVERHEATED PACK, PACK TRIP LIGHT CAME ON. MAINTENANCE TESTED BOTH PACKS, AND DID NOT SDR 2000UALA00256Line · leakingLOST A HYDRAULIC SYSTEM. CONTINUED TO ORD. EXTENDED GEAR MANUALLY. TOWED TO GATE. *S/D* FOUND NR 2 ENG HYD PUMP PRESS OUT LINE CRACKED AT SUPPORT CLAMP. REPLACED INLET PRESSURE LINE AND RETURN LINE. CHECKED CASE DRAIN FILTER. SERVICED HYDRAULIC SYSTEM.SDR 2000UALA00273Skin · damagedAIRCRAFT FUSELAGE IMPACTED BY GROUND EQUIPMENT. RPL FRAMES 65-61420-10, 65-16342-35 & -34, 65-16343-69 & -68AT BS 1050, 65-16342-35 & -34 AT BS 1030, 65-61420-10 AT BS 1026.4, 65-56156-80, 65-16344-44. REPAIRED FRAMES 65-16341-65 BETWEEN STR 18R AND 25R AT BSDR 2000UALA00252Connector · failedRIGHT WING ANTI-ICE VALVE INOPERATIVE. *S/D* MAINTENANCE REPORTED FINDING BURNT WIRING IN STUBWING VALVE CONNECTOR D932. CONNECTOR WAS REPLACED. OPERATIONAL CHECK NORMAL. NO FURTHER PROBLEMS REPORTED.SDR 2000UALA00253Battery · dischargedEMERGENCY LIGHTS INOPERATIVE AT L1 DOOR ENTRY, LEFT HAND SIDE ABOVE OVERWING EXIT DOORS (ROWS 14 AND 156ABC) AND OVERWING EXTERIOR AT STATION 940 RIGHT SIDE. *S/D* RECONNECTED LOOSE EEL STRIP AND REPLACED A BATTERY CARTRIDGE ASSEMBLY AT STATION 940 RT SIDE. SDR DL72K000920Pump · damagedAS ENG POWER WAS ADVANCED FOR TAKEOFF NR 1 ENG FLAMED OUT. EPR ON NR 1 ENG REACHED 1.3 BEFORE ENGINE INST. ROLLED BACK, NO TAKEOFF WAS INITIATED. FOUND ENG FUEL PUMP SHEARED. REPLACED SAME AND ENG FUEL CONTROL.SDR DL72S000916Fcu · malfunctionedON CLIMBOUT, NR 2 ENG ALL INDICATORS FLUX AND EGT AT 580 DEG. REPLACED FUEL CONTROL.SDR 2000UALA00235Light · failedINSIDE EMERGENCY LIGHT AT DOOR 1R INOPERATIVE. *S/D* REPLACED LIGHT ASSEMBLY.SDR 2000UALA00236Duct · crackedTHE NR 2 ENGINE INLET GUIDE VANE ANTI-ICE SYSTEM DUCT FOUND TO BE CRACKED THREE QUARTERS OF THE WAY AROUND. REPLACED THE NR 2 ENGINE INLET GUIDE VANE DUCT. ALSO REPLACED THE RIGHT HAND INLET GUIDE VANE ANTI-ICE VALVE AND ACTUATOR. OPERATIONALLY CHECKED GOODSDR 2000UALA00234Compensator · leakingHYDRAULIC SYSTEM A FAILURE ON TAXI OUT PRIOR TO TAKEOFF. *S/D* FOUND ''A'' SYSTEM AILERON FLIGHT CONTROL MODULE COMPENSATOR CARTRIDGE LEAKING. REPLACED COMPENSATOR PER MAINTENANCE MANUAL. SERVICED HYDRAULIC SYSTEM. PRESSURIZED ''A'' SYSTEM, NO LEAKS NOTEDSDR 2000UALA00231Pump · failedLEADING EDGE SLAT NR 6 DID NOT EXTEND FOR LANDING AT DEN. AIRCRAFT LOST SYSTEM A HYDRAULICS. AIRCRAFT TOWED TO THE GATE. *S/D* REPLACED NR 1 ENG HYD PUMP AND CASE DRAIN FILTER ASSY, NO CONTAMINATION WAS FOUND.SDR 2000UALA00315Battery · failedEMERGENCY EXIT LIGHT ABOVE AFT ENTRY DOOR INOPERATIVE. *S/D* REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.SDR 2000UALA00230Skin · crackedA CRACK IN THE FUSELAGE SKIN AND BEAR STRAP WAS DETECTED PROPAGATING FROM THE AFT LOWER CORNER OF THE FORWARD GALLEY DOOR OPENING. THE CRACK WAS PROPAGATING UNDERNEATH THE THRESHOLD PLATE. AFTER THE THRESHOLD PLATE WAS REMOVED THE CRACK WAS FOUND TO EXTEND ASDR 2000UALA00222Valve · stuckNR 1 ENGINE OIL TEMPERATURE AT 135 TO 140 DEGREES FOR 13 MINUTES. WENT TO 150 DEGREES AT SHUT DOWN. WINDMILLED ENGINE FOR 25 MINUTES. RE-STARTED ENGINE ON FINAL, RAN ENGINE FOR 9 MINUTES AND OIL TEMPERATURE 120 DEGREES. OIL PRESSURE AND QUANTITY GOOD ENTIRSDR 2000UALA00212Battery Pack · failedEEL CEILING LIGHT AT ROW 3 INOPERATIVE. *S/D* BATTERY PACK AND CHARGE CONTROL UNIT. REPLACED BATTERY PACK AND CHARGE CONTROL UNIT TEST OK.SDR 2000UALA00213Cover · damagedIMMEDIATELY AFTER TAKEOFF THERE WAS A LOUD NOISE FROM THE AREA JUST FORWARD OF DOOR 1 LEFT. SOUND SUBSIDED DURING DESCENT BELOW 160 KNOTS. PRESSURE NORMAL. RETURNED TO ORD. *S/D* FOUND LOWER INTERIOR HINGE COVER DAMAGED, REPLACED SAME. ACCOMPLISHED PRESSSDR 2000UALA00214Panel · overheatedFORWARD FLIGHT ATTENDANTS PANEL REPORTED TO BE HOT AND HAS A SMOKEY ODOR. RETURNED TO DEN. *S/D* IN USE LIGHT ON AT FORWARD ATTENDANTS PANEL. RESET HANDSET. GROUND CHECKS GOOD.SDR CA000511011Fitting · cracked(CAN) FORWARD ENGINE MOUNT WAS REMOVED FOR INSPECTION AND A BUSHING ON THE O/B SIDE WAS MISSING.ATTACHED LUG ON MOUNT WAS FOUND CRACKED. THE FWD ENGINE MOUNT ASSY WAS REPLACED.SDR 2000UALA00208Switch · failedON GEAR RETRACTION WARNING HORN CAME ON. RETURNED TO DEN. *S/D* REPLACED NR 1 THROTTLE SWITCH. OPERATIONAL CHECK OK.SDR 2000UALA00209Air Duct · overheatedSMOKE IN CABIN AND SMOKE WAS SEEN COMING OUT OF RIGHT WHEEL WELL AREA JUST BEFORE PUSHBACK. ALL PASSENGERS EVACUATED THROUGH FORWARD CABIN DOOR. *S/D* OVERHEATED FLOW MULTIPLIER. REPLACED FLOW MULTIPLIER.SDR 2000UALA00203Duct · separatedGROUND CREW REPORTED THAT APU MADE A LOUD BANG. APU SOUNDED DIFFERENT AFTER THAT. THE CABIN FLOOR VIBRATED THEN THERE WAS SMOKE IN THE COCKPIT. *S/D* NO CAUSE REPORTED. DENVER LINE PERSONNEL REPLACED CLAMP AFTER FLOW MULTIPLIER BYPASS VALVE. OPERATIONALLSDR 2000UALA00199Altimeter · intermittentFORTY-FIVE MINUTES INTO FLIGHT CREW REPORTED RADIO PROBLEMS FOR BOTH 1 AND 2. TCAS, OPWS AND LLWS ALERT SYSTEMS ARE INOPERATIVE. DIVERTED TO MCI. *S/D* REMOVED AND REPLACED NR 1 RADIO ALTIMETER, OPERATIONAL NORMAL.SDR SCNA00031Line · looseDURING CRUISE FLIGHT, THE NUMBER ONE ENGINE OIL QUANTITY AND PRESSURE WERE FOUND LOW AND IN THE YELLOW ARC ON THE INDICATOR. THE FLIGHT CREW COMPLIED WITH ENGINE SHUT DOWN, PROCEDURES ON APPROACH. AIRCRAFT DIVERTED. THE OIL VENT LINE WAS FOUND LOOSE AT THE SDR DL72S000733Valve · damagedAIR TURNBACK DUE TO NR 3 ENGINE START VALVE LIGHT ILLUMINATED DURING CLIMBOUT. FOUND STARTER VALVE AT FAULT. ADDITIONAL DAMAGE TO STARTER AND STARTER ADAPTOR. REPLACED STARTER VALVE STARTER AND STARTER GEARBOX ADAPTER.SDR DL72W000715Fire Loop · intermittentAT 15,000 FT WITH B LOOP SELECTED FOR NR 3 ENGINE FIRE DETECTION SYS, NR 2 ENGINE FIRE LIGHT ILLUMINATED AND BELL. ABNORMAL POM C/W AND NR 2 ENG SHUTDOWN. FIRE LIGHT NEVER WENT OUT AND BELL INTERMITTENT. FOUND DETECTOR LOOP NR M447 BAD. REMOVED AND REPLACESDR 2000UALA00182Switch · dirtyTAIL SKID LIGHT ILLUMINATED AFTER TAKEOFF. RETURNED TO MSY. *S/D* MAINTENANCE CLEANED AND LUBED TAIL SKID UP SWITCH, S663. LANDING GEAR HANDLE WAS CYCLED SEVERAL TIMES WITH LANDING GEARS PINNED. NO PROBLEMS FOUND. NO FURTHER PROBLEMS REPORTED.SDR 2000UALA00181Oven · smokeRETURNED TO DEN DUE TO SMOKE SMELL IN CABIN FROM AFT GALLEY. *S/D* CABIN SMELL DUE TO MALFUNCTIONING AFT GALLEY UNIT. REPLACED AFT HOT UNIT. ALL CHECKS NORMAL NOW.SDR 20000525SH001Duct · ruptured13TH STAGE SADDLE DUCT RUPTURED, DAMAGING THE UPPER NR 1 ENGINE COWL, MAINTENANCE INSPECTED ENGINE AND FOUND NO OTHER DAMAGE. AFTER TAKEOFF, CREW REPORTED FIRE WARNING ON NR 1 ENGINE. CREW FOLLOWED STANDARD PROCEDURES AND RETURNED TO MBJ. (X)SDR 2000UALA00178Battery · dischargedEMERGENCY LIGHT IN AISLE ABOVE SEAT ROW 20 IS INOPERATIVE. *S/D* CLEANED CONTACTS AND RECHARGED BATTERY. OPERATIONAL NORMAL.SDR BJNA000402Engine · malfunctionedDURING FLIGHT FROM COS PILOT NOTICED ENGINE OIL LEVEL GETTING LOW. OIL LEVEL CONTINUED TO DECREASE AND LOW LEVEL LIGHT STARTED TO ILLUMINATE. PILOT DECIDED TO SHUTDOWN NR 1 ENGINE 15 MINUTES OUT OF LAS. PILOT DECLARED EMERGENCY, AND LANDED SAFELY AT LAS. PSDR P2EA00110Engine · vibrationMCI - UNUSUAL VIBRATION NOTED FROM NR 1 ENGINE AT IDLE TO 55 PERCENT N-1 AFTER PUSHBACK. REPLACED NR 1 ENGINE PER VANGUARD TASK CARD J271-00-01-C. LEAK AND OPERATIONAL CHECKS OK. (X)SDR 2000UALA00177Relay · arcedNR 2 TANK LEFT FORWARD, LEFT AFT AND RIGHT FORWARD BOOST PUMP CIRCUIT BREAKERS POPPED AFTER TAKEOFF. ONLY THE RIGHT AFT PUMP WAS STILL WORKING AND THAT FAILED BEFORE LANDING. RETURNED TO MSY. *S/D* MAINTENANCE FOUND SIGNS OF ARCING AT R109 ESS BUS RELAY ASDR 2000UALA00174Battery · inoperativeEXIT SIGN ABOVE AIRSTAIR DOOR DOES NOT COME ON WHEN EMERGENCY SWITCH IS ON. *S/D* REPLACED CHARGER AND BATTERY.SDR L1GA200000243Anti-Ice Valve · inoperativeRT FUEL HEAT LIGHT CAME ON DURING TAXI-OUT. RETURNED TO GATE. REMOVED AND REPLACED ANTI-ICE VALVE, NR 2 ENG OPS CHK GOOD ON ENG RUN. RETURNED TO SERVICE.SDR 2000UALA00171Battery Pack · inoperativeEMERGENCY LIGHTS OVERWING EXIT SIGNS RIGHT SIDE AND FORWARD ENTRY DOOR SLIDE LIGHT INOPERATIVE. *S/D* REPLACED M1086 AND M982 BATTERY PACK, OPERATIONALLY CHECKED GOOD. (REPLACED (P/N 900835A AND 6013211LB).SDR 2000UALA00169Skin · crackedRIGHT ELEVATOR HAS AN APPROXIMATELY 8 INCHES L SHAPED CRACK IN THE SKIN STARTING FROM THE SMALL RECTANGULAR ACCESS PANEL JUST FORWARD OF THE OUTBOARD END OF THE TRIM TAB. *S/D* FATIGUE CRACK. INSTALLED REPAIR DOUBLER IN CONJUNCTION WITH BEADED DOUBLER REPAISDR 2000UALA00170Tube · brokenFUEL TANK NR 1 DROPPED FROM 11,600 TO 10,900 ON TWO SUCCESSIVE LEGS WHILE FEEDING ALL ENGINES FROM TANK 2. BALANCE WAS CORRECTED AND REMAINED STABLE WITH X-FEEDS SET TO ENGINE FOR REMAINDER OF THE FLIGHT. *S/D* BROKEN NR 1 TANK VENT TUBE. REPLACED VENT TUSDR 2000ZZZM272Engine · fodDFW - FLT 1396 - JUST AT ROTATION NR 1 ENGINE EXPERIENCED SEVERE COMPERSSOR STALL. SHUT DOWN ENGINE RETURNED AND LANDED DFW WITHOUT INCIDENT. REPLACED NR 1 ENGINE. SYSTEM GROUND CHECK NORMAL OPERATION. FOD DAMAGE FROM TREAD SEPARATION OF NR 1 MLG TIRE. (MSDR 2000UALA00154Actuator · malfunctionedNR 4 LEADING EDGE SLAT CYCLING OPEN AND CLOSED IN FLIGHT. DIVERTED TO MCO. *S/D* REPLACED NR 4 LEADING EDGE FLAP ACTUATOR AND SWITCH PER 27-83-06, OPERATIONALLY CHECKS NORMAL.SDR 2000UALA00159Switch · malfunctionedLEADING EDGE SLAT NR 4, RIGHT INBOARD DISPLAYED INTRANSIT AT SLAT POSITION 2 AND 0. CYCLED TWICE AND GOT THE SAME INDICATION. RETURNED TO DEN. *S/D* REPLACED NR 4 LEADING EDGE FLAP ACTUATOR AND SWITCH PER 27-83-06, OP CHECKS NORMAL.
Back to Pratt & Whitney JT8D-15