SDR 96UAL900190Fuel Transfer · failedUNWANTED FUEL TRANSFER OUT OF NR 1 MAIN FUEL TANK. REPORTED 1000 POUND LOSS WITH NO PUMPS ON.SDR 96UAL900191Engine · power lossCREW REPORTED LOSING POWER IN CLIMB, CRUISE, AND DESCENT. FRICTION LOCK WORKS NORMAL AND NO THROTTLE MOVEMENT IS EVIDENT. ALL INDICATIONS SHOW LOSS OF POWER. ACCOMPLISHED ENGINE POWER RUN. ENGINE PARAMETERS NORMAL AND STEADY DURING TAKEOFF AND PART POWER SSDR DL72E960583Fuel Contl Unit · failedNR 1 ENGINE FLAMED-OUT AS TAKEOFF POWER WAS BEING APPLIED. C/A: REPLACED FCU AND FUEL PUMP. LEAK CHECKED AND RIGGED PER PFHB. OPS CKS OK.SDR DL72K960541Fuel Control · failedENGINE FAILURE, NR 3, AT LIFT-OFF - FUEL TO ZERO WITH NORMAL WIND DOWN INDICATIONS. REPLACED FCU AND ENGINE DRIVEN FUEL PUMP.SDR 96UAL900174Circuit Breaker · malfunctionedRETURNED TO DEN, DUE TO PRESSURIZATION PROBLEMS. FAILED STANDBY TEST. PULLED AND RESET ALL CIRCUIT BREAKERS.SDR 96UAL900170Fire Loop · out of positionNR 1 ENGINE FIRE DETECTION SYSTEM INOPERATIVE. SQUIB TEST REMAINS ON FOR A SHORT TIME AFTER TEST. FOUND LOWER LOOP RUBBING AGAINST ENGINE COWLING. REPOSITIONED LOOP, FIRE DETECTION SYSTEM CHECKS OKAY.SDR 96UAL900164Fan · failedELECTRICAL FUMES NOTICED IN CENTER OF CABIN, COULD NOT ISOLATE CAUSE. FOUND GASPER FAN POPPING CIRCUIT BREAKER. REPLACED GASPER FAN. OPERATIONALLY CHECKED OKAY AND NO ODOR NOTICED.SDR 96UAL900161Batteries · dischargedRT EEL EXIT DOOR PANEL LIGHTS INOPERATIVE. REPLACED BATTERIES.SDR 96UAL900156Pressurization · malfunctionedDIVERTED TO CID DUE TO LOSS OF PRESSURIZATION. SUPPLEMENTAL DATA UPDATE: AIRCRAFT CHECKED FOR OBVIOUS DEFECTS. NONE FOUND. AIRCRAFT PRESSURE CHECKED OKAY. VERIFIED FORWARD CARGO HEAT OUTFLOW WORKING. NO SUBSEQUENT COMMENTS ON PRESSURIZATION.SDR 96UAL900153Sensor · failedNO FIRE TEST ON NR 1 ENGINE. SUPPLEMENTAL DATA UPDATE: REPLACED NR 1 ENGINE LOWER SENSOR. CHECKS NORMAL.SDR 96UAL900154Pt7 Tube · leakingABORTED TAKEOFF AT 60 KNOTS DUE TO NR 3 ENGINE LOW POWER INDICATION. RETURN TO BLOCKS AT ORD. INTERMEDIATE PT7 MANIFOLD TUBE WAS FOUND TO BE LEAKING DURING PRESSURE CHECK. ENGINE PRESSURE RATIO TRANSMITTER AND INDICATOR WERE REPLACED PER PRECAUTIONARY.SDR 96UAL900146Blade · fracturedDURING CLIMBOUT, HEARD LOUD SQUEAL AND VIBRATION FROM NR 2 ENGINE. EPR DROPPED OFF FROM 2.17 TO APPROXIMATELY 1.6 AND THEN EGT BEGAN TO CLIMB RAPIDLY. PERFORMED ENGINE SHUTDOWN. ORIGIN OF FAILURE NOT DETERMINED DUE TO THE ENGINE OPERATION AFTER THE FAILURE.SDR 96UAL900147Power Supply · inoperativeLT OVERWING EMERGENCY EXIT HATCH EXTERNAL LIGHT INOPERATIVE. REPLACED POWER SUPPLY DUE TO BATTERY CONNECTION TERMINAL BROKEN OFF.SDR AU960332Probe · blocked(AUS) NO1 ENGINE PT2 PROBE BLOCKED WITH INSECT REMAINSSDR CAL960206Engine · failedIAH - FLT 1926 - THE NR 3 ENGINE THROTTLE BEGAN TO VIBRATE AT 1,200 FEET DURING CLIMB-OUT OF IAH. A STRONG VIBRATION WAS REPORTED IN REAR CABIN. THE NR 3 ENGINE POWER WAS REDUCED, BUT THE VIBRATION CONTINUED. A LOUD BANG ACCOMPANIED BY NR 3 ENGINE SHUTDOWN SDR 96UAL900143Battery Pack · dischargedALL EMERGENCY EXIT LIGHTS IN THE AIRCRAFT ARE OUT, INSIDE AND OUT, FERRIED TO DEN. DEN REPLACED BATTERIES AND AFT STAIR LIGHT UNIT.SDR 96UAL900133Csd · failedAFTER NR 1 ENGINE WAS STARTED THE LEFT PACK SMOKED UP CABIN. REPLACED CONSTANT SPEED DRIVE DUE TO INOPERATIVE GENERATOR. NO SUBSEQUENT COMMENTS ON SMOKE IN CABIN.SDR 96UAL900125Fire Bell · malfunctionedFLIGHT CREW ADVISED FIRE WARNING SYSTEM BELL DOES NOT RING WHEN SYSTEM IS TESTED. SUPPLEMENTAL DATA UPDATE: REPLACED AURAL WARNING BOX ASSEMBLY. OPERATIONALLY, CHECKS OK.SDR 96UAL900126Fire Test · inoperativeNR 2 ENGINE FIRE TEST INOPERATIVE.SDR 96UAL900127Rib · crackedRIGHT ELEVATOR LOWER SURFACE INBD END HAD POPPED AND HAD LOOSE RIVETS. AFTER REMOVAL OF ACCESS PANEL FOUND STIFFENER RIB CRACKED. MANUFACTURED AND INSTALLED NEW RIB, REPLACED POPPED AND LOOSE RIVETS.SDR 96UAL900128Battery Pack · dischargedFOUND SEVERAL INOPERATIVE EEL STRIP LIGHTS IN MAIN CABIN, INCLUDING BOTH OVERWING EMERGENCY EXITS. REPLACED BATTERY PACK AND GROUND CHECKED NORMAL.SDR 96UAL900121Fire Det Loop · inoperativeNR 2 ENGINE FIRE TEST INOPERATIVE, FIRE DETECTION LOOP WOULD NOT GROUND TEST. REPLACED FIRE DETECTION LOOP FOR NR 2 ENGINE AND GROUND TEST NORMAL.SDR 96UAL900122Pack · odorFUMES IN COCKPIT WITH PACKS RUNNING. SUPPLEMENTAL DATA UPDATE: OPERATED BOTH PACKS FOR 1 HOUR AND NO FUMES NOTICED.SDR 96UAL900123Battery Pack · dischargedEMERGENCY EXIT LIGHT AT CENTER AISLE CEILING ADJACENT TO AFT GALLEY WOULD NOT GO OUT. REPLACED BATTERY PACK AND CIRCUIT BOARD BASE, CHECKS NORMAL.SDR 96UAL900117Light · inoperativeAFT GALLEY EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY.SDR 96UAL900118Light · inoperativeEEL DOOR FRAME LIGHT INOPERATIVE DOOR 1 LEFT. REPLACED FEEDER.SDR 96UAL900119Battery Pack · inoperativeEMERGENCY EXIT LIGHT ABOVE DOOR 2R AT AFT GALLEY INOPERATIVE. REPLACED BATTERIES.SDR 96UAL900105Switch · shortedGALLEY HOT PLATE NR H41 WAS SMOKING, SPARKING AND GAVE A FLIGHT ATTENDANT A SHOCK. CHECKED WIRING UNDER HOT PLATE ELEMENTS BEHIND CONTROL SWITCH AND NO OVERHEATING EVIDENT. REPLACED SWITCH AND HOTPLATE OPERATION CHECKS NORMAL.SDR 96UAL900106Actuator · failedDURING FLAP RETRACTION ON DEPARTURE, LED NR 6 REMAINED FULLY EXTENDED AFTER MOVING FLAP HANDLE FROM POSITION 2 TO ZERO. FLIGHT RETURNED TO ORD. NR 6 LEADING EDGE SLAT ACTUATOR FAILED IN THE EXTENDED POSITION. ACTUATOR WAS REPLACED AND OPERATION WAS NORMAL.SDR 96UAL900107Connectors · dirtyTWO EMERGENCY EXIT LIGHTS INOPERATIVE AT LEFT OVERWING WINDOWS. CLEANED CONNECTIONS, CHECKS OKAY.SDR 96UAL900108Power Supply · inoperativeEXTERIOR LEFT FWD OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED POWER SUPPLY ASSEMBLY (P/N M654).SDR 96UAL900109Air Distr · smokeWHILE OPERATING PACKS ON GROUND WITH APU AIR, CABIN FILLED WITH SMOKE. OPERATED PACKS FROM APU FOR OVER AN HOUR AND NO ODOR NOTED. SUSPECT DE-ICING FLUID. CHECKED APU AND FLOW MULTIPLIER INLETS, NO RESIDUAL FLUID NOTED.SDR 96UAL900110Door · missingCREW REPORTS, LOUD NOISE FROM NOSE GEAR AREA. GROUND CREW FOUND EXTERNAL POWER DOOR MISSING. NEW DOOR AND ATTACHMENTS INSTALLED.SDR 96FDEA00195Fuel Control · failedAT IDLE POWER NR 3 ENGINE FAILED TO RESPOND TO THROTTLE MOVEMENT. CONTINUED OPERATION UNTIL NR 3 GEN FAILED. ACCOMP ENGINE SHUTDOWN PROCEDURES IAW CHECKLIST PROCEDURES AND LANDING UNEVENTFUL. REMOVED AND REPLACED MAIN FUEL PUMP AND FUEL CONTROL UNITS AS PERSDR AWXA960054Engine · failedCMH/BOS - FLT 1620 - AIR TURNBACK, IN-FLIGHT SHUTDOWN. ENGINE 2 LOW OIL PRESSURE LIGHT ILLUMINATED WITH PRESSURE ERRATIC. OIL TEMPERATURE AROUND 10. SHUT DOWN ENGINE. FOUND FERROS METAL IN THE MAIN ENGINE OIL FILTERS. REMOVED AND REPLACED ENGINE. (X)SDR AU960170Disc · corroded(AUS) ENGINE 9TH STAGE HIGH PRESSURE COMPRESSOR DISC CONTAINED CORROSION PITTING IN THE BLADE SLOT PRESSURE FACES AND BLADE SLOTSIDES IN EXCESS OF LIMITS - FOUND DURING INSPECTION IAW PWA SB 6038 AND AD/JT8D/29 - ENGINE HAD BEEN FITTED TO A LOW UTILISATIONAIRCSDR 96ZZZM255Pt7 Jam Nut · looseFLT NR 282 - MDW-CMH - ABORTED TAKEOFF, NR 2 EPR INDICATION WAS LOW AND FLUCTUATING. MAINTENANCE INSPECTION AND FOUND THE P2 TEST CAP AT EPR TRANSMITTER LOOSE AND THE JAM NUT AT PT7 TEE FITTING TO TRANMITTER LOOSE, RESECURED. RAN ENGINES TO TAKEOFF POWER. ESDR AWXA960035P2 Cap · looseFLT NR 282 - MDW-CMH - ABORTED TAKEOFF, NR 2 EPR INDICATION WAS LOW AND FLUCTUATING. MAINTENANCE INSPECTION AND FOUND THE P2 TEST CAP AT EPR TRANSMITTER LOOSE AND THE JAM NUT AT PT7 TEE FITTING TO TRANMITTER LOOSE, RESECURED. RAN ENGINES TO TAKEOFF POWER. ESDR DL72L960238Prbc · failedON TAKEOFF, GOT COMPRESSOR STALL NR 2 ENGINE. INSPECTED INLET AND EXHAUST, ALL OK. RAN ENGINE TO TAKEOFF POWER, ALL CKS NORMAL, BUT ON DECEL GOT COMPRESSOR STALL AT 80 TO 85 N2. REPLACED PRBC, RAN ENGINE PER PFHB TEST-E AND ALL CKS GOOD.SDR DL72S960236Fuel Pump · failedON TAKEOFF ROLL CVG AT 78 KTS, NR 2 ENGINE APPEARED TO FLAME, ALL ENGINE INST ROLLED BACK. REJECTED TAKEOFF AND RETURNED TO GATE. INSPECTED INTAKE AND EXHAUST, PULLED OIL FILTER, ALL CHECKS OK. FOUND NO FUEL FLOW TO ENGINE. REPLACED FUEL CONTROL AND FUEL PSDR 96UAL900075Flow Contl Valve · malfunctionedAIRCRAFT RETURNED, UNABLE TO MAINTAIN PRESSURE. CABIN WOULD NOT HOLD MORE THAN 1 DIFFERENTIAL PRESSURE CLIMBING THROUGH 10K FEET, CABIN WAS 8,000 FEET. ACCOMPLISHED PRESSURE CONTROL SYSTEM CHECK, NO DEFECTS FOUND. RAN ENGINES AND DUCT PRESSURE NORMAL. AIRCSDR AU960707Chord · corroded(AUS) RH WING LEADING EDGE RIB 'T' AT STN 269.298 CORRODED ON THE BOTTOM FLANGE - FURTHER INVESTIGATION FOUND A SECTION OF THE CHORD APPROXIMATELY 152.4MM (6IN) FROM THE WING FRONT SPAR AND APPROXIMATELY 50.8MM (2IN) IN LENGTH COMPLETELY CORRODED AWAYSDR 96UAL900063Press Controller · malfunctionedAT 31,000 FT CABIN ALT OBSERVED AT 9,000 FT SWITCHED TO STANDBY AND CABIN CONTINUED TO CLIMB. WENT TO MANUAL AND FLIGHT RETURNED TO DEN. MAINTENANCE REPLACED PRESSURE CONTROLLER.SDR 96UAL900052Battery · dischargedEMERGENCY EXIT ABOVE DOOR 1L IS INOPERATIVE. REPLACED BATTERIES AND GROUND CHECKS GOOD.SDR 96UAL900053Sign · malfunctionedEMERGENCY EXIT LIGHT ABOVE DOOR 1 ILLUMINATES WITH POWER, SWITCH AND BATTERY OFF. REPLACED EXIT SIGN LIGHT ASSEMBLY AT DOOR 1L.SDR 96UAL900046Apu · smokingCREW REPORTED SMOKE AND FIRE COMING FROM APU ON ARRIVAL. RESET CB AND APU STARTED, NO SMOKE. COULD NOT DUPLICATE.SDR 96UAL900047Vent Tube · brokenWHILE OPERATING ALL OUT OF NR 2 FUEL TANK, THE NR 3 TANK DECREASED SLOWLY IN QUANTITY WITH ONLY THE AFT PUMP OPERATING. LEAKED 1,200 LBS OVER 1 HOUR 15 MINUTES. TURNING OFF BOTH BOOST PUMPS QUANTITY DECREASE STOPPED. FOUND BROKEN VENT TUBE AND REPLACED TUBESDR 96UAL900049Seam · leakingNR 2L EVACUATION SLIDE REMOVED FOR EXPIRATION OF TIME. SHOP FOUND MINOR SEAM LEAK ON THE TUBE DIRECTLY UNDER THE GIRT. REPAIRED SEAM LEAK, NON-STRUCTUAL.SDR AALA960045Fuel Pump · defectiveMEX - FLT 2087 - DURING DESCENT INTO MEX, FUEL HEAT APPLIED PER PROCEDURES. UPON LEVEL OFF WHEN POWER LEVERS INCREASED, NOTED NR 3 ENGINE HAD EXPERIENCED FLAME-OUT. ATTEMPTED NR 3 ENGINE RESTART. ACCOMPLISHED ENGINE SHUT-DOWN PROCEDURE AND AIRCRAFT PROCEEDESDR AU960722Skin · corroded(AUS) AIRCRAFT LOWER SKIN CORRODED AND SPLIT IN THE AREA OF THE LH RAM AIR INTAKE BETWEEN STRINGERS 27LH AND 28LH AT FRAME AT STN 700 - AREA OF CORROSION APPROXIMATELY 50.8MM BY 76.2MM (2IN BY 3IN) - INVESTIGATION FOUND THAT THE EXFOLIATION CORROSION WAS CAUS
Back to Pratt & Whitney JT8D-15