Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011041201766Switch · faultyEXTINGUISHER 1 BTL LT WILL STAY LIT WHEN TESTED. RPL NR 1 CARGO BTL DISCHARGE SWITCH, ACP TEST FROM BOTTLE TO SWITCH, TESTED GOOD PER MM. (PART# 563-3386)SDR UALA2011041201767Windshield · arcedF-O WINDSHIELD ARCING. REMOVED FO NR 1 WINDSHIELD. FOUND PRIMER LIFTING ON LOWER FRAME. CLEANED FRAME OF OLD PRIMER AND SEALANT. REAPPLIED FR PRIMER AND SEALANT PRIMER. CNTR WINDOW TRIM RMV'D FOR WINDOW 1R REPLACEMENT. ALSO 1R WINDOW SUN VISOR RAIL REMOVSDR UALA2011041201777Duct · damagedCENTER CABIN AIR DISTRIBUTION DUCT HAS NUMEROUS HOLES AT ROW 5. REPLACED PORTION OF DUCT ASSY BY ROW 5. LEAK CHECKS GOOD. AIRCRAFT INSPECTED AND IS IN A COND FOR SAFE FLIGHT. MAIN DISTRIBUTION DUCT IN CEILING ABOVE ROW 5 APPEARS TO HAVE HOLE OR CRACK ON TOP OFSDR UALA2011041201779Door · damagedAIRCRAFT HAS EXPERIENCED LIGHTNING STRIKE. DURING CLIMB NORTEAST OF IAD AT 12000 EXPERIENCED LIGHTNING STRIKE NOSE OF A/C. ACP'D LIGHTENING STRIKE INSP PER MM. SIX RIVETS HAD STATIC DISCHARGE FROM LIGHTENING STRIKE BETWEEN STA 347 AND 353 STRINGER AREA S25 TO SDR UALA2011041101749Idg · faultyR GEN TRIPPED OFF AFTER LANDING. FOUND RT IDG OVERSERVICED AND REPLACED RT GCU. REACTIVATED PER MEL RAN ENG SYS. OPERATED NORMALLY.SDR UALA2011041201768Seal · dirtyCREW REPORT: DOOR 2R HAS LOUD SQUEAL DURING CLIMB AND CRUISE. APPLIED REN AROUND THRESHOLD, CURING TIME. INSTLNG THRESHOLD THEN SEAL. DOOR RIG AND ACP PRESSURIZATION CHK TO DO. CLEANED SEAL. REPLACED NUT PLATE THAT HAD BAD FASTENER. INSTALLED ALL THREE 2RSDR UALA2011041201772Skin · dentedDENT REPORTED FWD OF DOOR 3R AT STATION 1630, STRINGER 19R, DENT 1" LONG. 5/32NDS DEEP SHARP, 3 QTR" WIDE. INSPECTED AND REPAIRED DENT PER UA-EVA-80517 AND SRM. HFEC ACP. PERMANENT REPAIR TO BE ACP WITHIN 50 FLT HRS. NEED A THREE SHIFT SLOT FOR REPAIR. NSDR UALA2011041301781Skin · damagedFUSELAGE SKIN AT BS 1610 STR 19 RT HAS DAMAGE. MAJOR REPAIR ACCOMPLISHED, REPAIR WAS COMPLETED PER INSTRUCTIONS ON EVA 80750 WITHOUT DEVIATIONS DURING A HMV3 VISIT IN TPA. THIS REPAIR MUST RECEIVE A NEW FAA FORM 8100-9 SHOWING COMPLIANCE TO 14CFR 25.571 AND 26SDR UALA2011041101735Computer · faultyWEATHER RADAR SHOWS YELLOW AND RED CELLS AT THE 40MILE. IN AUTO TILT OK IN MANUAL, REPEAT ITEM. WX AUTO TILT FUNCTION CONTROL BY EGPWS PER MM. REPLACED EGPWS COMPUTER PER MM. WX CHECKED OKAY.SDR UALA2011041101741Monitor · faultyF/A REPORTED FAINT ELEC SMELL AT DOOR 2 AREA. TURNED OFF LIGHTS & VIDEO AND SMELL STOPPED. DEBRIEFED WITH INBOUND FLT CREW AND SMELL WAS COMING FROM NEAR NR 4 VIDEO MONITOR. DEACTIVATING THE ENTIRE VIDEO SYS TURNED ALL CEILING LTS AND SIDE WALL LTS, THERE'S SDR UALA2011041101727Unknown · corrodedSTATION 1701 THRU 1720 HAS SURFACE CORROSION IN 2 PLACES. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION 2 AREAS FOUND TO BE OUT OF LIMITS STA 1704.5 AND 1708.5 RBL 50. PERFORMED HFEC OF FASTENER HOLES AND DECK PLATE NO DEFECTS NOTED. FABRICATED AND INSTALLESDR UALA2011041101746Light · inoperativeEMERGENCY LIGHT LOCATIONED AT MID LAV BURNT OUT. REPLACED EMERGENCY LIGHT, OPS CHECK GOOD.SDR UALA2011040801700Unknown · unknownFIVE UNITS TRIM IN CRUISE. ACCOMPLISH SPOILER SYSTEM OPERATIONAL CHECK, AILERON SYSTEM OPERATIONAL CHECK, FLAP SYSTEM OPERATIONAL CHECK AND ELEVATOR OPERATIONAL CHECK. ACCOMPLISHED OPERATIONAL CHECK OF EACH SYSTEM AND ALL CHECKS PASSED. NO FAULTS OR MESSAGESDR UALA2011041101715Line · crackedHYDRAULIC RETURN LINE CRACKED AT UPPER RT LANDING GEAR. REPLACED RETURN LINE. PRESSURIZED NO LEAKS NOTED.SDR UALA2011041101710Light · unsecureCREW REPORT: EMERGENCY EXIT FLOOR LIGHTING LOOSE AT 13C. SECURED LIGHT STRIP.SDR UALA2011040801693Circuit Card · faultyFIRE BELL AURAL WARNING WILL NOT EXTINGUISH. REPLACED M1000 BELL-CHIME AURAL WARNING CARD ASSY PER MM. CHECKS OKAY. ALSO REPLACED WARNING ELECTRONICS POWER SUPPLY MODULE.SDR UALA2011040701678Attach Bracket · out of toleranceRIGHT INBOARD TE AFT FLAP, INBOARD PUSHROD ATTACH BRACKET HAS BEARING LOOSE AND COMING OUT OF BRACKET. REPLACED BRACKET AND BEARING ASSY. BRACKET IS SECURED ON FLAP.SDR UALA2011040701690Light · missingEMERGENCY LIGHT ATTACHED TO SEAT 15ABC MISSING. INSTALLED NEW EMERGENCY LIGHT AND OPS CHECKED GOOD.SDR UALA2011040701691Light · inoperativeEMERGENCY LIGHT AT SEAT 18ABC INOPERATIVE. INSTALLED NEW LIGHT STRIP AT 18ABC, OP CHECKED GOOD.SDR UALA2011040701692Floorbeam · corrodedFLOORBEAM CAP AT STA 324 RBL 36 HAS MULTIPLE AREAS OF CORROSION. MAJOR REPAIR ACCOMPLISHED: ACCOMPLISHED REPAIR OF FLOORBEAM AT STATION 324 RBL 36 PER EVA 80737 AND PD 57-53-101.SDR UALA2011040801707Windshield · delaminated1ST OFFICER'S FIXED SIDE-AFT WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS. REPLACE FIRST AVAILABLE. CREW COMMENTS: WINDOW R3 HAS 2 DELAM BUBBLES SIZE OF A CHILDS HAND. REPLACED WINDOW PER MM.SDR UALA2011040601662Floorboard · damagedAISLE FLOOR ROW 20 HAS A DEEP INDENTATION. REPLACED ROW 20 AISLE FLOORBOARD IAW MM. ACFT RETURNED TO NORMAL CONFIGURATION.SDR UALA2011040601668Floor Panel · damagedSPONGY FLOOR MIDDLE OF AISLE JUST FWD OF OVERWING EXITS. INSTALLED NEW FLOORBOARD REF DWG 15F6868-599.SDR UALA2011040601672Handle · out of adjustL-1 DOOR BUTTERFLY HANDLES DO NOT FLUSH DURING OPERATIONAL CHECK. REPLACED L-1 DOOR EXTERNAL HANDLES CENTER SHAFT, INNER SHAFT AND CLUTCH COLLAR PER MM. ADJUSTED AND OPS CHECK GOOD PER CMM ON NON ROUTINE 31885.SDR UALA2011040601673Reservoir · out of toleranceL-1 DOOR POWER ASSIST RESERVOIR OUT OF DATE. REMOVED AND REPLACED L-1 DOOR POWER ASSIST RESERVOIR PER MM ON NON ROUTINE BY MECH AND INSP.SDR UALA2011040701686Sensor · faultyDOOR 1R SLIDE ARMED LIGHT DOES NOT ILLUMINATE. SLIDE ARM LIGHT INOPERATIVE. CONFIRMED GIRT BAR ENGAGEMENT NORMAL. LIGHT IS OK, SUSPECT ONE OF THE SENSORS TO BE AT FAULT.SDR UALA2011040801709Steering Sys · out of adjustAIRPLANE PULLS LEFT DURING TAXI. ADJUSTED NOSE WHEEL STEERING, TAXI TEST GOOD.SDR UALA2011040601657Floorbeam · corrodedCORROSION ON TOP OF FLOORBEAM AT STA 1640 RBL 24. MAJOR REPAIR ACCOMPLISHED: AFTER REMOVING CORROSION FOUND TO BE OUT OF LIMITS PER SRM. REMOVED TOP CHORD AT 1640 LB 10 THRU RBL 68. FABRICATED REPLACEMENT T-CHORD, ANGLES AND STRAPS FROM 7075-T6511 PER SRM.SDR UALA2011040601661Mechanism · lack of lubeDOOR 4L EXTERNAL DOOR HANDLE DOES NOT RETRACT. REMOVED EXTERNAL HANDLE CENTER SHAFT AND CLUTCH COLLAR, LUBED EXTERNAL HANDLE MECH AND ADJUSTED EXTERNAL HANDLE MECH. NOW WITHIN TOLERANCE.SDR UALA2011040501639Wire Harness · faultyTHE INSULATION ON WIRE BUNDLE LEADING TO F/O WINDOW IS DETERIORATED. OUTER PROTECTIVE INSULATION SPIRAL CABLE DETERIORATED FOR THE FO NR 2 WINDOW HEAT. WIRE INSULATION & CLEAR INSULATION STILL GOOD. CABLE NEEDS TO BE REPLACED. C-B PULLED & COLLARED PER MEL. SDR UALA2011040701676Tee Fitting · corrodedCORROSION AT STA 324 TEE FITTING. A REPAIR WAS PERFORMED.SDR UALA2011040401608Bracket · crackedDOOR 4R LWR GATE COVER BRACKET THAT SLIDE CHAIN ATTACHES TO IS CRACKED. INSTALLED NEW HARNESS LATCH BRACKET (P/N 69-59926-3) N-R 32131.SDR UALA2011040401628Panel · delaminatedLT VERTICAL STABILIZER PANEL AT APPROX STA 1770 TO STA 1808 PNL P/N 175N2001-35, FOR REPAIR. STARTED LT VERTICAL STAB PANEL REMOVAL, NEED TO CONTINUE WITH REMOVING PANEL FASTENERS.SDR UALA2011040401621Floor Support · corrodedFLOOR SUPPORT CORRODED STA 322, RBL 42. MAJOR REPAIR ACCOMPLISHED: FLOOR SUPPORT FROM STA 310.5 TO 322, RBL 42 REPLACED PER SRM.SDR UALA2011040401622Crease Beam · corrodedCREASE BEAM TRUSS BETWEEN BS 500 AND BS 480 HAS EVIDENCE OF CORROSION. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION FOUND OUT OF LIMITS PER SRM. FABRICATED CREASE BEAM ANGLES OUT OF 7075-T6 PER SRM. TREATED, PRIMED AND INSTALLED PER SRM.SDR UALA2011040401623Fitting · corrodedSTA 1720 RT CUSP TO BULKHEAD T-FITTING CORRODED AT PRESSURE DECK. MAJOR REPAIR ACCOMPLISHED: RT T-FITTING AT STA 1720 REPLACED PER SRM.SDR UALA2011040501634Intercostal · corrodedINTERCOSTAL CORRODED AT R1 DOOR BS 324 TO 367. MAJOR REPAIR ACCOMPLISHED: REPLACED INTERCOSTAL AT DOOR R1 STA 324 TO STA 367 PER SRM.SDR UALA2011040501635Beam · corrodedCORROSION ON SUB BEAM AT STA 1713, RBL 40 TO RBL 60. MAJOR REPAIR ACCOMPLISHED: REPLACED SUB BEAM AT STA 1713, RBL 40 TO RBL 60, PER SRM.SDR UALA2011040501638Battery · faultyMAIN BATTERY CHARGER STATUS MESSAGE IN CRUISE. REPLACED MAIN BATTERY AND CHARGER PER MM, OPS CHECKED NORMAL.SDR DALA1149690695Bonding · defectiveFRONT SPAR ENGINE FUEL FEED HOSE ELECTRICAL BONDING REWORKED IAW EA 06-093241-03, ME01, ME02.SDR UALA2011040401594Radio Altimeter · faultyWHEN THRUST IDLE IN DESCENT EICAS GEAR NOT DOWN CAME ON L RA YELLOW BOX FLASHING ON AND OFF. REPLACED LEFT RADIO ALTIMETER IAW MM. LANDING CONFIG SYS TEST CHECKED OKAY.SDR UALA2011040401600Guide Arm · defectiveDOOR 3R (AFT PAX DOOR) VERY DIFFICULT TO OPEN AND CLOSED. FOUND GUIDE ARM ATTACH BOLTS TO DOOR LOOSE AND GUIDE ARM ROD ARM BEARING WORN AND SERPENTINE GUIDE PIN WORN. REPLACED GUIDE ARM AND RIGGED. DOOR STILL VERY HARD TO OPERATE. FOUND HANDLE MECHANISM VESDR UALA2011040401616Relay · failedFUEL PROBLEM, FLT DIVERTED. COMPLIED WITH MEL 2822J, CTR TANK QTY 3.8K, CB'S PULLED AND WRAPPED WITH DF STICKER F20 F14, DF STICKER APPLIED OVER RT AND LT LENS COVER. DF555. WORK IN CONJUNCTION WITH DF554 FOR LT CTR PUMP INOP, PREVIOUSLY DEFERRED. COA 50722SDR UALA2011040501651Guide Arm · looseDOOR 3L VERY DIFFICULT TO OPEN AND CLOSE. FOUND GUIDE ARM ATTACH BOLTS TO DOOR LOOSE AND GUIDE ARM ROD ARM BEARING WORN AND SERPENTINE GUIDE PIN WORN. REPLACED GUIDE ARM AND RIGGED. DOOR STILL VERY HARD TO OPERATE. FOUND HANDLE MECHANISM VERY STIFF. WILL SDR UALA2011040401602Valve · faultyENG DUCT PRESSURES SPLIT DURING CRUISE WITH ISOL VLV CLOSED & BLEED SW SELECTED ON. RECORD DUCT PRESSURES. CREW COMMENTS: LEFT 45 PSI RIGHT 30 PSI CRUISE AT 26000FT. APPLIED MEL 3611A. REPLACED HIGH STAGE PILOT VALVE PER AMM. RAN ENGINE AT HIGH POWER PERSDR UALA2011040401604Light · inoperativeEMERGENCY LIGHTS INOP AFT CABIN ROWS 25 AND 33. RELAMPED BOTH POSITIONS, OPS CHECKED OKAY.SDR UALA2011040401605Light · inoperativeSEAT 23C EEL LT INOPERATIVE. REPLACED LIGHT ASSY, OPS CHECKED OKAY.SDR UALA2011040401610Housing · damagedRT MLG FWD TRUNNION SUPPORT BEARING HOUSING REPAIR HAS RECEIVED FIRST STAGE APPROVAL FOR STATIC STRENGTH AND IS TIME LIMITED TO 03APR11. A NEW FAA 8100-9 IS REQUIRED BY 03APR11 OR THE AIRWORTHINESS CERTIFICATE OF THIS AIRPLANE IS NO LONGER CURRENT. SFOLM TRUSDR UALA2011040101563Floorbeam · corrodedSTA 365 FLOORBEAM UPPER FLANGE CORRODED. MAJOR REPAIR ACCOMPLISHED: REPAIRED ON SM W-U E9952H PER SRM FROM LBL 8.5 TO RBL 59.SDR UALA2011040101565Light · bowedEMERGENCY LIGHT STRIP BOWING AT AISLE 13. CHECKED EEL TRACK LIGHTING. ROW 13 IS BULKHEAD FEED TO STRIP CAUSING SLIGHT RISE IN CARPET. NO DEFECTS NOTED. OK PER SMFMM.
Back to Pratt & Whitney PW2037