SDR UALA2011040101580Flow Divider · leakingFUEL LEAKING FROM APU DRAIN MAST. FOUND DRAIN FOR FUEL FLOW DIVIDER LEAKING ONLY WHEN APU NOT RUNNING AT 10 DROPS EVERY 14 SECONDS. LIMIT FOR STATIC LEAK ON THIS DRAIN IS 1 DROP PER SECOND. APU OK FOR SERVICE TO NEXT MAINT OP FOR FLOW DIVIDER CHANGE. REPLASDR UALA2011033101549Girt Bar · obstructedF/A REPORTS DOOR 2R NOT INDICATING FULLY DISARMED WHEN DISARMED. REMOVED SLIDE COVER AND CLEANED FOD FROM SLIDE ENGAGE BAR. SATISFACTORY ARM AND DISARM FUNCTION. REINSTALLED SLIDE COVER. BRIEFED OUTBOUND FLIGHT ATTENDANT AT DOOR 2R.SDR UALA2011033101542Structure · corrodedGALLEY G4B FLOOR DECK IS CORRODED FROM STA 1686, LBL 20 TO RBL 58. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND AREAS TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGE AND ACCOMPLISHED NDT INSPECTION OF AREA WITH NO CRACKS FOUND. ACCOMP THE FABRICATIONSDR UALA2011033101543Pan · corrodedGALLEY G4B FLOOR PAN IS CORRODED FROM STA 1680 TO 1686 LBL 20 TO RBL 58. MAJOR REPAIR ACCOMPLISHED: REPAIRED WITH PTT SEQ 2572135 UNDER PEMCO EA PD57-53-097. REMOVED CORROSION AND FOUND AREAS TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGE AND ACCOMPLISHED NDTSDR UALA2011033101548Cover · unsecureCREW REPORT: EMERGENCY EXIT LIGHT COVER FELL OFF AT 17ABC. REPLACED EMERGENCY LIGHT STRIP COVER.SDR UALA2011040101583Wire · brokenDURING NR 2 ENGINE START, LOST COCKPIT ELEC POWER. T-R MSG DISPLAYED ON LOWER EICAS. REPLACED LEFT TRU, NO HELP. LEFT ENG DID NOT TRANSFER PWR. SWAPPED LEFT AND RIGHT GCU, NO HELP. SWAPPED BACK. REPLACED LEFT GEN CNTL BREAKER C901 AND LEFT BUS TIE CNTL SDR UALA2011033001512Girt Bar · obstructedCREW REPORTED 1R GIRT BAR HARD TO DISARM. FOUND ICE AROUND GIRT. REMOVED ICE AND EXERCISED ARMING LEVER. OPS NORMAL.SDR UALA2011033001513Web · damagedELONGATED HOLES IN WEB AT STATION 324 RBL 30 - RBL 68. MAJOR REPAIR ACCOMPLISHED: REMOVED WEB ASSEMBLY AT STA 324 RBL 30 - RBL 68 AND FABRICATED NEW SECTION OUT OF 2024 - T3 .063 IAW B757 SRM. LOCATED AND DRILLED NEW WEB PER SRM. PRIMED AND ALODINED NEW PASDR UALA2011033001514Frame · crackedFWD CARGO FRAME HAS CRACK AT BS 600 AT STR 24L. MAJOR REPAIR ACCOMPLISHED: CUT OUT AND REMOVED DAMAGE FRAME, ACCOMPLISHED NDT OF AREA & FOUND NO CRACKS PER REF NDT. FABRICATED REPLACEMENT FRAME ASSEMBLY FROM 7075 T6 ,063 AND HEAT TREATED ON TRAVLER 2486N004SDR UALA2011033001515Frame · dentedFWD CARGO FRAME HAS DENTS IN TWO LOCATIONS AT BS 580 BETWEEN S-25L AND S-24L. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED FRAME. NDT INSPECTED AREA AND FOUND NO CRACKS PER NDT. FABRICATED FRAME OUT OF 7075 T-6 .063. HEAT TREATED PER PEMCO TRAVLER 2486N0041SDR UALA2011033001516Crease Beam · corrodedRIGHT CREASE BEAM UPPER SURFACE HAS CORROSION AT BS 975 AT RBL 71. MAJOR REPAIR ACCOMPLISHED: CORROSION FOUND TO BE OUT OF LIMITS PER SRM. FABRICATED NEW CREASE BEAM WEB OUT OF 7075-0 .063 PER SRM. HEAT TREATED AND PRIMED PER AMM. TOP COATED CREASE BEAM WSDR UALA2011033001517Feeder Cable · damagedWHILE TROUBLESHOOTING LOG 1 (EEL LIGHTS) FOUND NO OUTPUT FROM INVERTER (SEAT 28A). INPUT 6 VOLTS. INVERTER (560-0853) IS ON AOG. AOG H6079. REPLACED INVERTER AT 28A, NO HELP. REPLACED DAMAGED POWER FEEDER CABLE AND SECURED TRACK AND COVER AND RPL END CAP.SDR UALA2011033001536Floorbeam · corrodedFLOORBEAM CAP AT STA 365.25 HAS CORROSION FROM RBL 2 TO RBL 50. MAJOR REPAIR ACCOMPLISHED: FLOORBEAM CAP HAS PREVIOUS REPAIR WHICH IS ALSO CORRODED. CORR OUT OF LIMITS, CUT OUT DAMAGE, FABBED T-CHORD, 2 EA ANGLES, 2 EA. STRAPS & INSTALLED PER AMM'S.SDR UALA2011033101547Fan Blade · damagedNR 2 ENG N1 FAN 3EA FAN BLADES EVIDENCE OF FOD DAMAGE. NEED TO DRESS BLADES. REPAIRED 3 EA FAN BLADES (MARKED ON BLADE ROOT) ON NR 2 N1 FAN.SDR UALA2011033001524Lanyard · looseDOOR 3L WILL NOT ARM. SECURED LOOSE LANYARD IN POUCH. ARM DISARM FUNCTION CHECKS OKAY.SDR UALA2011032801489Skin · damagedLT INBOARD AFT FLAP INBOARD END POTTING SPLIT OPEN BOTH UPPER AND LOWER SKIN. MAJOR REPAIR ACCOMPLISHED: AREA FROM FWD SPAR T/E AFT 13 INCH ON UPPER SKIN AND 12 INCH ON LOWER SKIN AND OUTBOARD FROM INBD END OTBD 8 INCHES BOTH SIDES HAS DELAMINATION & FROZEN SDR UALA2011032901496Crease Beam · corrodedLEFT CREASE BEAM O/B FLANGE COMMON TO INTERNAL FUSELAGE CORRODED AT STA 1006, LBL 71. AGING ACFT INSP FINDINGS. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FABBED ANGLE, ACP'D HFEC ON ALL HOLES AND AREA FOR CRACKS. NO DEFECTS NOTED. INSTALLED ANGLE PER SDR UALA2011032901497Beam · corrodedAFT CARGO COMPARTMENT STATION 1620 LAP BEAM AT SW-30 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FABBED AND INSTALLED REPAIR DOUBLER PER PEMCO EA PD57-53-103.SDR UALA2011032901498Floorbeam · corrodedSTATION 324 RBL 41 FLOORBEAM HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED FLOORBEAM STA 324, RBL 41 IAW PEMCO EA PD57-536-096.SDR UALA2011032901499Guard · looseEMERGENCY EXIT LIGHT SWITCH COVER LOOSE AT DOOR 1L. REPLACED GUARD.SDR UALA2011033101561Plate · missingLOUD AIR NOISE IN FORWARD CABIN. REMOVE CEILING PANELS AS REQUIRED AND CHECK AIR DISTRIBUTION DUCT FOR DAMAGE AND CONDITION. REMOVED PANELS. FOUND ALL INTACT. RE-INSTALLED ALL PANELS. REMOVED NOZZLE BETWEEN MONITORS 2 AND 3. FWD OF MONITOR 3 FOUND 6" SECSDR UALA2011032801488Seal · leakingCHRONIC FLIGHT DECK NOISE. AIR LEAK FOUND AT THE AFT SIDE OF THE FIRST OFFICERS SLIDING WINDOW. REPLACED RT NR 2 WINDOW SEAL. AIRCRAFT WILL NEED TO BE PRESSURIZED AND NR 2 RT WINDOW LEAK CHECKED. LEAK CHECK IS GOOD. CABIN AIR RISER DUCTS DISCONNECTED FROSDR UALA2011032801482Relay · faultedMAIN BATTERY CHARGER MESSAGE, SUSPECT RIGHT BUS NOT POWERED. REPLACED MAIN SHIP BATTERY AND MAIN BATTERY CHARGER, NO HELP. REPLACED MAIN BATTERY CHARGER DISABLE RELAY K115, NO HELP. PER FIM 24-31-00 P106 PAGE BLOCK 7. FOUND A1-90VAC, B1-77VAC, C1-115VAC. TSDR UALA2011032801470Light · inoperativeDOOR NR 2 LT OUTBD EMERGENCY EXIT LIGHT INOP. RELAMPED, OPERATES NORMAL.SDR UALA2011032801471Duct · dirtyCREW REPORT: RIGHT RECIRC FAN VERY LOUD, INTEFERES WITH COCKPIT COMMUNICATIONS, MUCH QUIETER WITH FAN OFF. COMPLIED WITH MEL TO DEACTIVATE THE RIGHT RECIRC FAN. PLZ WORK WITH CH1578. IF IT IS DETERMINED BLOCKAGES EXIST, AND GND TIME IS INSUFFICENT TO PERFOSDR UALA2011032801477Slide · dischargedMAIN CABIN R-2 DOOR ESCAPE SLIDE HAS LOW PRESSURE. R-2 PASSENGER DOOR-MOUNTED ESCAPE SLIDE INFLATION BOTTLE PRESSURE HAS IMPROPER INFLATION. GAUGE NEEDLE IS BELOW (LEFT) OF GREEN BAND. REMOVED AND REPLACED R-2 DOOR SLIDE ASSY PER MM.SDR UALA2011032801478Latch · malfunctionedDOOR 4R IS HARD TO CLOSE, AFT LATCH ROLLER IS FALSE LATCHING AT UPPER AFT CAM. ADJUSTED R-4 DOOR GUIDE ARM PER MM AND OPS CHECK GOOD.SDR UALA2011032801479Girt Bar · out of adjustDOOR 4R SLIDE LIGHT INOP WITH DOOR ARMED. ADJUSTED R-4 DOOR GIRT BAR MECHANISM PER MM AND OPS CHECK DOOR LIGHT GOOD PER MM.SDR UALA2011032901493Slide · unwanted deployL-1 DOOR SLIDE INADVERTENTLY DEPLOYED. REPLACED L-1 DOOR SLIDE PER MM.SDR UALA2011032501437Cam · out of positionL-1 DOOR WILL NOT DISARM. REPOSITIONED L-1 DOOR LOCK OUT CAM PER MM AND FUNCTIONAL CHECK OF ARM AND DISARM LEVER IS NORMAL ON NON ROUTINE 20100.SDR UALA2011032501432Floorbeam · corrodedFLOORBEAM HAS CORROSION AT STATION 1661 LBL 11 AND RBL 4. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED AREA OF TOP CHORD AND FABRICATED REPLACEMENT BEAM AND 2 SUPPORT ANGLE AND 2 STRAPS IAW SRM. TREATED AND PRSDR UALA2011032501433Floorbeam · corrodedSTATION 365.25 RBL 0 TO RBL 40 FLOORBEAM IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND ARE TO BE OUT OF LIMITS. REMOVED TEE CHORD AND ATTACHING ANGLE. FABRICATED TEE CHORD AND SUPPORT ANGLES. TREATED & PRIMED PARTS PER SRM. INSTALLED TEE SDR UALA2011032501434Floorbeam · corrodedCORROSION ON CABIN FLOOR BEAM AT STA 1640 AT RBL 14 TO RBL 40. MAJOR REPAIR ACCOMPLISHED: REMOVED TEE ANGLE IAW SRM, DUE TO EXCESSIVE MATERIAL REMOVED AND OUT OF LIMITS. FABRICATED REPLACEMENT TEE CHORD & INSTALLED PER SRM. TREATED AND PRIMED IAW SRM. TOP COASDR UALA2011032801459Structure · damagedCREW REPORT: LEFT ELEVATOR TRAILING EDGE BY FUSELAGE SMALL AREA OF DAMAGE. SAMC TEXT: DAMAGE IS 8 INCHES FROM INBD EDGE OF LEFT ELEVATOR, THE DAMAGE IS A DENT .625 INCHES DEEP AND 1.750 INCHES WIDE ON THE TRAILING EDGE. ELEVATOR EDGE IS CRUSHED AT DAMAGE LSDR UALA2011032801460Lanyard · out of positionCREW REPORT: DOOR 2L WILL NOT ARM PROPERLY, IT IS DIFFICULT TO MOVE ARMING LEVER. SAMC TEXT: INSPECT DOOR SILL AREA FOR ANY FOREIGN OBJECTS AND CONTACT SAM FOR ARM-DISARM CHECK PAPERWORK. FOUND SURVIVAL LANYARD INTERFERING WITH GIRT BAR. REPOSITIONED LANYSDR UALA2011032801461Filter · dirtyODOR LIKE ACETONE VERY STRONG AROUND ROWS 11 &12 AND THROUGHOUT CABIN. REPLACED LEFT AND RIGHT RECIRCULATION HEPA FILTERS PER MM.SDR UALA2011032501447Lamp · faultyDOOR 2L ARM LIGHT WILL NOT ILLUMINATE. REPLACED INOP LAMPS, CHECKS SATISFACTORY.SDR UALA2011032801462Idg · faultyLEFT ENGINE GEN DROPPED OFF LINE ON FINAL. RESET ON 1ST ATTEMPT. REPLACED NR 1 IDG PER MM. LEFT ENGINE IDG WAS DISCONNECTED FOR DEF. THEN DF NOT FINISHED. STILL DISCONNECTED. CONFIRMED IDG CONNECTED DURING ENG RUN. LEFT ENGINE GEN DRIVE LIGHT NOT ILLUMINATED.SDR UALA2011032801463O-Ring · leakingRT WHEEL WELL INTERLOCK ACTUATOR (M10279) LEAKING AT UNION FITTING OUTBD LINE (MKD W-TAPE). REPLACED O-RING AND SECURED LINE. LEAK CHECKED. NO LEAKS NOTED.SDR UALA2011032501441Sensor · inoperativeF/A REPORTED DOOR 3R SLIDE ARMED LIGHT INOP. VERIFIED GIRT BAR ENGAGEMENT CORRECT AND DOOR ARMS CORRECTLY. ONLY LIGHT INOP. NEEDS LIGHT SOCKET ASSY, (PCN 561-2342) NIS AT MCO. WILL NEED TIME TO DISASSEMBLE OVERHEAD DOOR LINER TO REPLACE SWITCH ASSY L408. SDR UALA2011032501414Floorbeam · corrodedFLOORBEAM HAS EVIDENCE OF CORROSION AT STA 1640 FROM BL 64 TO BL 0. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION REMOVAL AREA OF FLOORBEAM WAS OUT OF LIMITS PER SRM. REMOVED DAMAGE UPPER CHORD AT STA 1640 LBL 10 - RBL 65. PERFORMED NDT OF CUT OUT AND FOUND SDR UALA2011032501415Shear Tie · corrodedAFT CARGO PIT CORROSION DISCOVERED AT BS 1620 ON SHEAR TIE AT S-30. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION REMOVAL IT WAS DISCOVERED TO BE BEYOND LIMITS IAW SRM. FABRICATED A NEW SHEAR TIE FROM 7075-T6, 063 PER SRM AND INSTALLED PER SRM.SDR UALA2011032501436Plate · corrodedMAIN CABIN L-2 DOOR UPPER AND LOWER SERPENTINE PLATES CORRODED AND LUBE DEPRIVED. REMOVED L-2 DOOR, REMOVED AND CLEANED UPPER AND LOWER CAM PLATES PER MM, RE-INSTALLED CAM PLATES AND DOOR PER MM AND OPS CHECK GOOD.SDR UALA2011032501431Floorbeam · corrodedSTA. 1640 FLOORBEAM CORR. 0 BL TO 59 RBL, TOP FLG. MAJOR REPAIR ACCOMPLISHED: REPAIRED PER SRM, REPAIR. NR 5, ON SM W-US E9906H, E9917H & E9959H.SDR UALA2011032501435Switch · malfunctionedLANDING GEAR MONITOR CAME BACK ON ECS MESSAGE PAGE GEAR DOOR MSG DISPLAYED AND PSEU BITE CHECK FAULTS LEFT MLG DOOR CLOSED SENSOR S10242. REPLACED LEFT MAIN GEAR DOOR LOCKED SWITCH S10371, GROUND CHECKED OKAY.SDR UALA2011032401402Idg · faultyNR 1 IDG TEMP SENSOR MESSAGE INTERMITTENTLY ON. NO TIME TO T/S, HAS HISTORY. REPLACED NR 1 IDG, OPS GOOD.SDR UALA2011032501439Lamp · intermittentDOOR NR 4 SLIDE LEFT EXTERIOR EMERGENCY LIGHT INTERMITTENT. RELAMPED PER MM.SDR UALA2011032201385Wedge · damagedFLT CREW ON WALKAROUND REPORTS METAL PROTRUDING FROM LEFT WING UPPER WINGROOT. NR 5 L/E SLAT HAS 4 X 4 INCH TEAR TO SKIN PANEL ON UPPER SURFACE ADJACENT TO TRAILING EDGE WEDGE. REMOVED NR 5 L/E SLAT FOR REPAIR TO SHOP. REPLACED LEADING EDGE SLAT NR 5 PER MMSDR UALA2011032301394Speaker · faultyCAPT'S SPEAKER MAKES STATIC NOISES EVEN WHEN TURNED ALL THE WAY DOWN. REPLACED CAPT'S SPEAKER.SDR UALA2011032101352Shutoff Valve · faultyRT ENG FUEL SHUTOFF VLV WOULD NOT OPEN FOR ENG RUN. REPLACED FUEL SHUT-OFF VALVE PER MM. OPS CHECK NORMAL.
Back to Pratt & Whitney PW2037