SDR 2005UALA00161Shear Tie · corrodedAFT PIT SHEARTIE HAS CORROSION STA 1460, BETWEEN STR 28L AND 28R. REPLACED SHEAR TIE.SDR 2005UALA00162Floorbeam · corrodedAFT CABIN FLOORBEAM HAS CORROSION UPPER CAP STA 1640, RBL 11 TO RBL 12. TYPICAL FLOOR BEAM CORROSION. DAMAGE WAS TRIMMED. NEW SECTION OF FLOOR BEAM WAS SPLICED IN USING SPLICE ANGLES.SDR ASMF200502010Engine · lack of lubeDURING ENGINES STARTING, RT ENGINE DID NOT STABILIZED AND WAS SHUTDOWN. OIL QTY CHECKED & REFILLED TO THE CORRECT LEVEL. RT ENGINE RESTARTED & ACFT DISPATCHED BUT IT RETURNED TO PLATFORM DUE TO DURING TAXING OIL TEMP INDICATION 177 DEGREES. ACFT SENT TO HASDR 2005UALA00140Frame · dentedAFT PIT STA 1480 FRAME IS DENTED ON INBD FLANGE AT STR 26L. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00141Splice · corrodedAFT PIT STA 1400 LBL 18 CIRCUMFERENTIAL SPLICE IS CORRODED. DAMAGE CAUSED BY TYPICAL STA 1400 PIT CORROSION. FABRICATED CIRCUMFRENTIAL SPLICE STRAP AND REPLACED CORRODED STRAP.SDR 2005UALA00142Shear Tie · corrodedAFT PIT FRAME SHEAR TIE IS CORRODED AT STA 1400 BETWEEN STRINGERS 27L AND 28L. DAMAGE CAUSED BY TYPICAL STA 1400 PIT CORROSION. REPLACED SHEAR TIE.SDR 2005UALA00143Shear Tie · corrodedAFT PIT FRAME SHEAR TIE IN BILGE AREA IS CORRODED AT STA 1400 BETWEEN STR 28L AND 29L. DAMAGE CAUSED BY TYPICAL STA 1400 PIT CORROSION. REPLACED SHEAR TIE.SDR 2005UALA00144Shear Tie · corrodedAFT CARGO PIT SHEAR TIE CORRODED AT BS 1340 AND RBL 27. DAMAGE CAUSED BY TYPICAL AFT PIT CORROSION. REPLACED SHEAR TIE.SDR 2005UALA00145Shear Tie · corrodedSTA 1400 SHEAR CLIP SEVERELY CORRODED. DAMAGE CAUSED BY TYPICAL STA 1400 PIT CORROSION. REPLACED SHEAR TIE.SDR 2005UALA00146Shear Tie · corrodedSTA 1400 FRAME SHEAR TIE BETWEEN STR 29R AND 30R IS SEVERELY CORRODED. DAMAGE CAUSED BY TYPICAL STA 1400 PIT CORROSION. REPLACED SHEAR TIE.SDR 2005UALA00148Skin · damagedCREASE NEAR BELLY CENTERLINE AT BS 1385 (EXTERIOR). SKIN DOUBLER REPAIRS AND STRINGER REPAIRS WERE ACCOMPLISHED.SDR 2005UALA00149Skin · damagedCREASE NEAR BELLY SKIN CENTERLINE AT BS 1420 (EXTERIOR). SKIN DOUBLER REPAIRS AND STRINGER REPAIRS WERE ACCOMPLISHED.SDR 2005UALA00150Frame · dentedAFT PIT STA 1580 AT STR 26L FRAME IS DENTED ON INBD FLANGE. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00151Frame · dentedAFT PIT STA 1360 AT STR 26L FRAME INBD FLANGE IS DENTED. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00152Frame · dentedAFT PIT STA 1560 AT STR 26L FRAME IS DENTED ON INBD FLANGE. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00153Frame · dentedAFT PIT STA 1620, FRAME IS DENTED AT STR 25L ON INBD FLANGE. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00154Frame · dentedAFT PIT STA 1620 FRAME IS DENTED ON INBD FLANGE AT STR 25R. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00139Frame · dentedFRAME FLANGE AT BS 1540 AND STR 25L DENTED. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00138Light · inoperativeEMERGENCY SLIDE LIGHT ON EXTERIOR OF AIRCRAFT AFT OF LT WING INOP. RELAMPED PER AMM 33-51-06-201SDR 2005UALA00135Skin · dentedEXTERIOR FUSELAGE SKIN AT STA 600 TO 620 BETWEEN STR 15L AND 18L HAS 8 EACH DENTS. PARTIAL SKIN REPLACEMENT ACCOMPLISHED. PARTIAL SKIN PANEL REMOVED AND NEW SECTION SPLICED IN USING SPLICE DOUBLERS AND TRIPLERS.SDR 2005UALA00137Frame · dentedAFT PIT STA 1460 AND STR 25L, FRAME IS DENTED ON THE INBD FLANGE. INSTALLED NESTED J-ANGLE REPAIR.SDR 2005UALA00126Floorbeam · corrodedFLOORBEAM UPPER CAP IS CORRODED AT STA 365, RBL 16-73. SUPPLEMENTAL DATA UPDATE TYPICAL FLOORBEAM CORROSION DAMAGE. MAJOR REPAIR ACCOMPLISHED. REPAIRED USING NEW T-CAP SECTION AND SPLICE ANGLES.SDR 2005UALA00134Skin · damagedAREA 20 INCHES AFT OF DOOR 3 RIGHT IS DAMAGED. SKIN WAS HFEC INSPECTED FOR CRACKS AND A DOUBLER REPAIR WAS INSTALLED.SDR 2005UALA00120Shear Tie · crackedFUSELAGE AT FRAME STA 640, FWD SHEAR TIE IS CRACKED AT STR 16L. SUPPLEMENTAL DATA UPDATE SHEAR TIE CRACKED DUE TO IMPACT DAMAGE. MAJOR REPAIR ACCOMPLISHED. SHEAR TIE WAS FABRICATED AND REPLACED.SDR 2005UALA00121Shear Tie · damagedSHEAR TIE HAS ELONGATED HOLES STA 620, BETWEEN STR 16L AND 17L. SUPPLEMENTAL DATA UPDATE SHEAR TIE FOUND DAMAGED DURING REPLACEMENT OF PREVIOUS REPAIR IN THE AREA. MAJOR REPAIR ACCOMPLISHED. SHEAR TIE REPLACEMENT WAS FABRICATED AND INSTALLED.SDR 2005UALA00122Floorbeam · damagedFLOORBEAM T-CAP IS DAMAGED AT STA 1640, BL-0 TO RBL 61. SUPPLEMENTAL DATA UPDATE EXISTING REPAIR REQUIRED MODIFICATION. ORIGINAL DAMAGE CAUSED BY TYPICAL FLOORBEAM CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED EXISTING REPAIR AND INSTALLED NEW T-CAP SECTIOSDR 2005UALA00123Pressure Panel · damagedAFT PRESSURE DECK HAS DAMAGE AT STA 1681 TO 1691, RBL 29 TO RBL 56. SUPPLEMENTAL DATA UPDATE DAMAGE CAUSED BY TYPICAL FLOOR CORROSION UNDER THE GALLEY AREA. MAJOR REPAIR ACCOMPLISHED. REMOVED EXISTING REPAIRS AND INSTALLED NEW DOUBLERS ON THE AFT PRESSURE DSDR 2005UALA00124Floorbeam · corrodedCABIN FLOORBEAM STA 365 HAS CORROSION RBL 3 TO RBL 26 UPPER T-CAP. SUPPLEMENTAL DATA UPDATE DAMAGE CAUSED BY TYPICAL FLOORBEAM CORROSION. MAJOR REPAIR ACCOMPLISHED. DAMAGE TO THE T-CAP REMOVED. T-CAP REPLACEMENT SECTION FABRICATED AND INSTALLED USING SPLICSDR 2005UALA00119Floorbeam · corrodedFWD CABIN FLOORBEAM HAS CORROSION AROUND FASTENERS AT STA 324, RBL 51 TO RBL 52, BEAM UPPER CAP. DAMAGE DUE TO CORROSION. MAJOR REPAIR ACCOMPLISHED. DAMAGE WAS BLENDED. ANGLE REPAIR WAS INSTALLED.SDR 2005UALA00125Skin · damagedFUSELAGE SKIN AT STA 1600 STR 14R IS DAMAGED. SUPPLEMENTAL DATA UPDATE DENT DAMAGE CAUSED BY IMPACT WITH FUSELAGE SKIN. MAJOR REPAIR ACCOMPLISHED. SKIN DAMAGE WAS CUTOUT AND REPAIR DOUBLER AND STRUCTURAL FILLER INSTALLED.SDR 2005UALA00117Skin · damagedEXTERNAL FUSELAGE SKIN DAMAGED STA 1618 AT STR 19L. INSTALLED SKIN AND STRINGER REPAIRS.SDR 2005UALA00133Skin · damagedEXTERIOR FUSELAGE 2 FT AFT OF EE DOOR FROM STA 540 TO 580 IS DAMAGED. DAMAGE CAUSED BY IMPACT. TEMPORARY BLIND FASTENER REPAIR WAS INSTALLED. THIS REPAIR WAS REMOVED AND REPLACED WITH ANOTHER EXTERNAL DOUBLER REPAIR INSTALLED WITH PERMANENT SOLID FASTENERS.SDR 2005UALA00108Actuator · malfunctionedUNWANTED FUEL TRANSFER INDICATION. DEFECTIVE CROSS-FEED VALVE ACTUATOR.REPLACED CROSS-FEED VALVE.SDR ASMF200501016Fuel Control · malfunctionedAIRCRAFT RETURNED TO PLATFORM AS A CONSEQUENCE OF DURING TAXING AND AFTER RIGHT ENGINE STARTING AUTO-SHUTDOWN WITHOUT ANY APPARENT CAUSE. CAPTAIN PERFORMED CLEANING PROCEDURE FOR ENGINE REVISION. ENTRANCE, EXHAUST AND MASTER CHIP DETECTOR OF RIGHT ENGINE WERSDR 2005UALA00092Frame · dentedAFT PIT STA 1580 FRAME IS DENTED ON INBOARD FLANGE AT STR 25. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE REPAIR.SDR 2005UALA00093Frame · dentedAFT PIT AT STA 1540 FRAME INBOARD FLANGE IS DENTED AT STR 25R. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE REPAIR.SDR 2005UALA00094Frame · dentedAFT PIT FUSELAGE FRAME INNER FLANGE IS DENTED AT BS 1440, STR 25L. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME FLANGE WITH A NESTED J-ANGLE REPAIR.SDR 2005UALA00095Frame · dentedAFT PIT FUSELAGE FRAME INNER FLANGE IS DENTED AT BS 1400, STR 25L. *S/D* DAMAGE DUE TO TYPICAL CARGO LOADING IN AFT PIT. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE REPAIR.SDR 2005UALA00089Light · damagedEMERGENCY EQUIPMENT LIGHT DAMAGED ROW 1. REPLACED STRIPSDR 2005UALA00086O-Ring · leakingDOOR 1 RIGHT SLIDE LOW BOTTLE PRESSURE. SUPPLEMENTAL DATA UPDATE FILLER VALVE O-RING LEAKING. REPLACED O-RING.SDR 2005UALA00079Skin · dentedLT FUSELAGE SKIN AT BS 610 AND STR 16L IS DENTED ON A PREVIOUS REPAIR DOUBLER. REPAIRED SKIN WITH A DOUBLER-TRIPLER.SDR 2005UALA00080Frame · dentedAFT PIT STA 1480 FRAME IS DENTED ON INBD FLANGE, APPROXIMATELY STR 26L. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE REPAIR.SDR 2005UALA00081Frame · dentedFWD PIT FRAME DENTED ON INBD FLANGE AT STA 620 JUST BELOW STR 24L. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE.SDR ASMF200501015Valve · failedDURING TRANSIT CHECK WAS DETECTED A HYDRAULIC LEAK IN THE LEFT ENGINE FILTERS MODULE TUBE, TUBE WAS TIGHTENED AND ENGINE WAS MOTORIZED, BUT DURING THE PROCESS A NEW LEAK WAS DETECTED IN THE DE-OILER. AIRCRAFT WAS SENT TO THE HANGAR AND DURING OVERNIGHT SERVICSDR 2005UALA00164Aspirator · distortedFOUND ASPIRATOR FLATTENED DURING INSPECTION FOR OVERHAUL. ASPIRATOR MIXING TUBE WAS DISTORTED AT DISCHARGE END. IT IS SUSPECTED THAT ASPIRATOR HAD BEEN DAMAGED DURING THE LAST PACKING PROCESS. NO OTHER DAMAGE WAS OBSERVED. ASPIRATOR WAS REPLACED.SDR ASMF200501006Valve · leakingDURING FUEL SERVICE WAS DETECTED HIGH SUPPLY PRESSURE ON FUEL DISPENSER (80 PSI), PROMOTING FUEL LEAK ON RT CENTRAL TANK VALVE. AIRCRAFT WAS FUELED THROUGH LT VALVE AND RT VALVE WAS DEFERRED IAW MEL 28-21-1. DURING OVERNIGHT SERVICE RT FUEL VALVE WAS REPLACED SDR 2005UALA00053Windshield · crackedDIVERTED DUE TO A CRACK IN THE CAPT SIDE WINDSHIELD, LEFT TO RIGHT EDGE WITH WINDOW HEAT ARCING. WINDOW HEAT FAILURE. REPLACED WINDOW, AND WINDOW HEAT CONTROL.SDR 2005UALA00051Skin · damagedLEFT EXTERIOR FUSELAGE AT STA 620, STR 16L, REPAIR DOUBLER IS DENTED. REMOVED EXISTING DOUBLER AND REPLACED SKIN DOUBLER REPAIR.SDR 2005UALA00052Skin · damagedEXTERIOR FUSELAGE AT STA 1420 BETWEEN STR 28R AND 30R, SKIN IS CREASED. FRAME SHEAR TIES WERE REPLACED.SDR 2005UALA00042Intercostal · corrodedMAIN CABIN AFT SIDE OF STA 365 FLOORBEAM, RBL 45 SEAT TRACK END, TOP SURFACE OF INTERCOSTAL CORRODED BEYOND LIMITS AT FLOORBEAM ATTACHMENT. FABRICATED & INSTALLED DOUBLER AND FILLER.
Back to Pratt & Whitney PW2037