Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 99UAL900095Rt Recirc Fan · failedDIVERTED TO OKC WITH PERSISTENT BURNING RUBBER ODOR IN THE CABIN. *S/D* CAUSE OF RUBBER ODOR WAS DETERMINED TO BE A FAULTY RT RECIRCULATION FAN. THE FAN WAS REPLACED AND NO FURTHER REPORTS OF SMOKE HAVE OCCURRED SINCE.SDR 99UAL900108Tube · leakingSLIDE FAILED AIR RETENTION TEST DURING SHOP VISIT. *S/D* POROSITY CAUSED SEAM LEAK. UNIT WAS SENT TO VENDOR FOR EVALUATION AND REPAIR.SDR 99UAL900107Tube · leakingSLIDE FAILED AIR RETENTION TEST DURING SHOP VISIT. *S/D* POROSITY CAUSED SEAM LEAK. UNIT WAS SENT TO VENDOR FOR EVALUATION AND REPAIR.SDR 99UAL900110Tube · leakingSLIDE FAILED AIR RETENTION TEST DURING SHOP VISIT. *S/D* POROSITY CAUSED SEAM LEAK. UNIT WAS SENT TO VENDOR FOR EVALUATION AND REPAIR.SDR 99UAL900111Tube · leakingSLIDE FAILED AIR RETENTION TEST DURING SHOP VISIT. *S/D* POROSITY CAUSED SEAM LEAK. UNIT WAS SENT TO VENDOR FOR EVALUATION AND REPAIR.SDR 99UAL900112Tube · leakingSLIDE FAILED AIR RETENTION TEST DURING SHOP VISIT. *S/D* POROSITY CAUSED SEAM LEAK. UNIT WAS SENT TO VENDOR FOR EVALUATION AND REPAIR.SDR 99UAL900066Mask · leakingDIVERTED TO ORD DUE TO DECREASING CREW OXYGEN PRESSURE. *S/D* THE HOSE TO THE OBSERVER OXYGEN MASK BOX WAS REPLACED BECAUSE IT WAS FOUND LEAKING.SDR DL75A990132Fairing · detachedNR 2 ENG FWD PYLON FAIRING DEPARTED AIRCRAFT DURING T/O. RETURNED TO DFW. REPLACED FAIRING.SDR 99UAL900047Warning · activatedDIVERTED TO PHX UNDER AMBER ALERT DUE TO FLAP/SLAT PROBLEM. *S/D* CHECKS OF THE SYSTEM DID NOT REVEAL A ROOT CAUSE, AND PROBLEM COULD NOT BE DUPLICATED. SYSTEM OPERATIONALLY CHECKED OK.SDR 99UAL900040Sensor · failedDOOR 1L AND 3R ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHTS INOP. *S/D* REPLACED BOTH PROXIMITY SENSORS AT 3R DOOR AND CLEANED PROXIMITY SENSORS AT 1L DOOR, OP CHECK OK.SDR 99UAL900031Tat Probe · failedRETURNED TO FIELD DUE TO TAT PROBE EICAS MESSAGE. *S/D* TAT PROBE FAILED. REPLACED TAT PROBE PER APPLICABLE MM.SDR 99UAL900032Switch · failedOXYGEN MASKS DEPLOYED ON TOUCH DOWN. *S/D* RECEPTICLE ON S119 ALTITUDE PRESSURE SWITCH WAS FOUND DETACHED FROM SWITCH BODY. REPLACED S119 AND PERFORMED CALIBRATION CHECK PER MM 35-21-00.SDR 98UAL900616Switch · failedLANDED LAX UNDER AMBER ALERT DUE TO LEADING EDGE SLAT ASYMMETRY. *S/D* FAILURE OF ONE OF TWO INBOARD LEADING EDGE SLAT LOSS SWITCHES CAUSED THE EICAS MESSAGE, LIGHT AND SHUTDOWN OF THE LEADING EDGE SLAT SYSTEM. REPLACED BOTH INBOARD SLAT LOSS SWITCHES AND RSDR DL72S982552Battery Pack · dischargedRT FWD OVERWING EMERGENCY LIGHT INOP. REPLACED CARTRIDGE AND BATTERY PACK.SDR DL72S982553Battery Pack · dischargedRT OVERWING EMERGENCY LIGHT INOP. REPLACED BATTERY PACK AND CARTRIDGE.SDR DL757982551Compressor · stalledNR 2 ENG COMP STALL AFTER TAKEOFF AT APPROX 10,000 FT, OVERTEMP 692. FLAMES NOTED, ENGINE SHUTDOWN IN FLIGHT BY CREW. TEMP ONLY STARTED TO DECREASE AFTER FUEL WAS SHUTOFF. REPLACED NR 2 ENG PER TRANS 6T103.SDR 98UAL900597Hose · failedLANDED LAX UNDER AMBER ALERT DUE TO THE LOSS OF THE LEFT HYDRAULIC SYSTEM. *S/D* FOUND MLG DOWNLOCK PRESSURE HOSE RUPTURED. REPLACED HOSE.SDR DL757982526Pump · failedDESCENDING THROUGH 10000 FT INTO SNA SPEEDBRAKES EXT LT HYD QTY MSG ILLUM. OVERHEAD PNL YIELDED LT SYS PRESS LIGHT. LT ENG PUMP PRESS LIGHT AND LT ELEC PUMP PRESS LIGHT. ALSO, LT YAW DAMPER LIGHT ILLUM. LT HYD QTY ZERO. FOUND LT EDP CASE DRAIN PRESSURE FISDR 98UAL900589Seal · looseRETURNED TO FIELD DUE TO DOOR 1L SQUEAL. *S/D* RESECURED LOOSE INNER COSMETIC TRIM SEAL, PRESSURIZED TO 8 PSI WITH NO SQUEALS NOTED. OPS CHECKS NORMAL.SDR 98UAL900585Power Strip · failedEEL LIGHTING FROM ROW 9 TO ROW 16 INOP. REPLACED EEL FEEDER POWER STRIP FROM ROW 9 TO ROW 16.SDR 98UAL900588Union · facturedLANDED SFO UNDER AMBER ALERT DUE TO LOSS OF LEFT HYDRAULIC SYSTEM. *S/D* FOUND PRESSURE LINE UNION FITTING ON NR 1 EDP PRESSURE AND CASE DRAIN FILTER ASSY BROKEN. REPLACED UNION AND FILTERS, CHECKED ACMP AND EDPM FILTER FOR CONTAMINATION AND NONE WAS FOUND.SDR 98UAL900581Pneumatic Syst · smokingCREW REPORTED TWO AFT SMOKE DETECTORS SOUNDING INTERMITTENTLY. *S/D* MAINTENANCE DETERMINED THAT THE CAUSE OF SMOKE IN CABIN WAS A RESULT OF PNEUMATIC SYSTEM OIL CONTAMINATION FROM THE APU. THE SUSPECT APU WAS REPLACED IN ORD ON 12/3/98. PACK BURNOUT WAS ASDR 98UAL900552Fan · fodDIVERTED TO CLE DUE TO AN EQUIPMENT OVERHEAT INDICATION. *S/D* THE OVERHEAT INDICATION WAS TO REMOVE DEBRIS FROM THE EQUIPMENT COOLING FANS. THE SOURCE OF THIS DEBRIS IS PRESENTLY UNDER INVESTIGATION.SDR 98UAL900544Apu · fodOIL LIKE ODOR DETECTED IN REAR CABIN AREA. THE ODOR WAS NOT STRONG OR PUNGENT, BUT IT DID SET OFF THE AFT LAV SMOKE DETECTORS. *S/D* THE APU WAS REPLACED DUE TO CONTAMINATED PNEUMATICS. DURING DISASSEMBLY AND SHOP INSPECTION OF THE APU A PLASTIC BAG WAS FOSDR 98UAL900524Seal · coakedFLIGHT DIVERTED TO TLH DUE TO SMOKE IN THE COCKPIT AND CABIN. *S/D* AFTER ENGINE DISASSEMBLY, EVIDENCE SHOWED OIL HAD GONE THROUGH THE HPC OF THE NUMBER 2 ENGINE. THIS CAUSED SMOKE TO PASS THROUGH THE RIGHT ENGINE BLEED. THE NUMBER 2 ENGINE WAS REPLACED.SDR 98UAL900631Material · leakingSLIDE FAILED AIR RETENTION DURING SHOP TEST. *S/D* UNIT WAS SENT TO THE VENDOR FOR EVALUATION AND REPAIR. THE SLIDE LEAKED DUE TO POROSITY OF THE INFLATABLE MATERIAL, AND WAS BEYOND REPAIR.SDR 98UAL900523Retract Mech · malfunctionedLANDED UNDER AMBER ALERT DUE TO A TRAILING EDGE FLAP DEPLOYMENT PROBLEM.SDR 98UAL900506Wire · brokenRETURNED TO ORD DUE TO ELECTRICAL PROBLEMS. *S/D* W2018-0002-06 WAS FOUND BROKEN AT LEFT GENERATOR CIRCUIT BREAKER C901 PHASE B. LOSS OF PHASE B AT L GEN CB CAUSED PARTIAL ELECTRICAL FAILURE. THE BROKEN WIRE TERMINAL WAS REPLACED.SDR 98UAL900491Disarm Light · malfunctionedDOOR 1 LEFT EMERGENCY ESCAPE SLIDE LIGHTS REMAIN ILLUMINATED IN THE ARMED AND DISARMED POSITION. *S/D* CYCLED DOOR ARM HANDLE SEVERAL TIMES AND FOUND LIGHT TO OPERATE NORMAL.SDR DL757982052Skin · crackedNR 2 NACELLE STRUT SKINS, IB AND OB WERE FOUND CRACKED BEYOND PREV STOP DRILLS, ON REPETITIVE INSP BOTH WERE REPAIRED ON SRM 54-51-01-2-203 MIF ERA 259383-14. LOCATION IS NAC STA 107.7 REPAIR IS CLASSIFIED MAJOR.SDR 98UAL900471Fan · malfunctionedDIVERTED TO HNL WITH A LEFT RECIRCULATION FAN PROBLEM.SDR 98UAL900470Line · failedLANDED UNDER AMBER ALERT DUE TO LOSS OF FLUID FROM THE LEFT HYDRAULIC SYSTEM. *S/D* LEFT HAND DOWNLOCK ACTUATOR LINE DAMAGED. LINE REPLACED.SDR 98UAL900450Valve · failedDIVERTED TO DEN WHEN IT BECAME DIFFICULT TO MAINTAIN CABIN PRESSURE. *S/D* EQUIPMENT COOLING OVERBOARD EXHAUST VALVE FAILED. SHOP FOUND MOTOR BEARING FROZEN. SHOP REPLACED BEARING AND VALVE OPERATES CORRECTLY.SDR DL757981867Engine · failedDURING DESCENT, RT ENGINE OIL QTY SHOWED 0. RT ENGINE OIL PRESS LIGHT CAME ON. ENGINE SHUTDOWN PER CHECK LIST. REPLACED ENGINE.SDR 98UAL900441Valve · failedAIRCRAFT RETURNED DUE TO A LOUD HUM AND VIBRATION IN THE FORWARD PASSENGER CABIN. *S/D* EQUIPMENT COOLING OVERBOARD EXHAUST VALVE FAILED CAUSING VIBRATION DURING CLIMB. SHOP FOUND DAMPER BROKEN.SDR 98UAL900410Hpc Vane · out of adjustRIGHT ENGINE FUEL FLOW AND EPR GAUGES STARTED SURGING PASSING THROUGH FL330 ON CLIMB. CREW ALSO FELT RIGHT ENGINE SURGING. FLIGHT DECENDED TO FL250 AND ENGINE RETURNED TO NORMAL INDICATIONS. FLIGHT RETURNED TO SFO WITH EQUIPMENT STANDING BY. *S/D* ENGINE SDR 98UAL900408Actuator · failedRETURNED TO ORD DUE TO A LEADING EDGE FLAP PROBLEM. *S/D* POSITION NUMBER 15 LEADING EDGE SLAT ACTUATOR WAS FOUND WITH AN INTERMITTENT PROBLEM CAUSING THE EICAS MESSAGE AND LOCKOUT OF THE LEADING EDGE SLATS. REPLACED NUMBER 15 LEADING EDGE SLAT ACTUATOR ANDSDR 98UAL900388Manifold · crackedMADE AN UNSCHEDULED LANDING INTO DEN, BECAUSE THE NUMBER 2 ENGINE WAS SHUTDOWN DUE TO LOSS OF OIL. *S/D* FOUND CRACKED OIL BREATHER MANIFOLD. REPLACED MANIFOLD AND RELEASED A/C BACK INTO SERVICE AFTER WINDMILLING INSPECTION PER 757 MM. MANIFOLD HAS BEEN RETSDR 9809875534Engine · failedDURING FINAL APPROACH AT 1000 FEET, NR 2 ENGINE EXPERIENCED A COMPRESSOR STALL AND FLAMED OUT. AN UNEVENTFUL SINGLE ENGINE LANDING WAS PERFORMED. MAINTENANCE FOUND TRACE OF METAL IN THE TAILPIPE AND REPLACED THE ENGINE.SDR 98UAL900361Blade · crackedTHREE LOUD JOLTS CAME FROM RIGHT ENGINE DURING CLIMB. *S/D* ENGINE WAS REPLACED AND A FAILED 6TH STAGE HPC BLADE WAS DISCOVERED AFTER ENGINE DISASSEMBLY. THE UA INVESTIGATION FOUND THAT A 6TH STAGE BLADE HAD FAILED DUE TO FATIGUE CRACKING ORIGINATING 2/3 OFSDR 98UAL900330Idg · failedCREW DIVERTED TO DEN DUE TO LOSS OF NUMBER 2 GENERATOR. *S/D* THE IDG STATOR ASSEMBLY HAD SHIFTED WHICH CAUSED A CRACK IN A CONTROL CURRENT TRANSFORMER CONNECTION INTERNAL TO THE GENERATOR. REPLACED NUMBER 2 INTEGRATED DRIVE GENERATOR.SDR DL757981483Engine · failedON CLIMB-OUT, FL 260, LT ENG STALLED AND QUIT ALL ENG IND WENT BLANK CLB 2 SELECTED SHUTDOWN CK LIST C/W RETURNED TO CVG. REPLACED NR 1 ENG PMA AND ROTOR SHAFT CKS, OK.SDR DL757981471Stator · failedNR 1 ENG STALLED AT V1 AND AUTO SHUT DOWN HARD CARD AND POM EMERGENCY PROCEDURES FOLLOWED RETURNED TO RUNWAY 9L. BORESCOPED OK OF 6TH STAGE LPT - 16TH STAGE HPC CKS OK, CKD WIRING BETWEEN EEC AND SVA ALL OK. REPLACED EEC AND SVA AS PRECAUTION DUE TO EICAS MSSDR 98UAL900317O-Ring · tornLANDED MCI UNDER AMBER ALERT DUE TO LOSS OF LEFT HYDRAULIC FLUID. *S/D* FLUID LEAKING AT TORN O-RING FOUND ON ENGINE HYDRAULIC LINE QUICK DISCONNECT FITTING. REPLACED O-RING.SDR 98UAL900314Fuel Control · malfunctionedON TAKEOFF, MAX POWER OF 1.42 EPR SET, LEFT ENGINE WAS 1.42. RIGHT ENGINE 1.38 TO 1.39 EPR. RIGHT ENGINE FUEL FLOW SEVERAL HUNDRED POUNDS LESS THAN LEFT ENGINE. LEFT ENGINE HAD THROTTLE REMAINING. RIGHT ENGINE THROTTLE AGAINST THE FIREWALL.SDR DL757981416Ecu · failedAPU FLAMED OUT IN FLT FOLLOWED PROCEDURES AND GOT APU FAULT LIGHT, NO START ALLOWED. ONE ENG GEN PREV DEFERRED, ROBBED APU CONTROL ECU FROM A/C 628. INSTALLED BITE CK OK. OPERATED APU W/AIR AND ELECTRIC OPS NML.SDR 98UAL900310Slide · deployedNUMBER 1 RIGHT DOOR SLIDE DEPLOYED. *S/D* INADVERTENT DEPLOYMENT DUE TO HUMAN ERROR. DEPLOYMENT WAS NORMAL. SLIDE WAS REPLACED.SDR 98UAL900306Air Compressor · failedRETURNED TO LAX DUE TO VIBRATION UNDER AFT GALLEY. *S/D* POTABLE WATER SYSTEM ELECTRIC AIR COMPRESSOR FAILED. COMPRESSOR WAS REPLACED AND AN OPERATIONAL CHECK WAS PERFORMED. COMPRESSOR CHECKED OUT OK.SDR 98UAL900291Hydraulic Line · rupturedRETURNED TO ORD DUE TO LEFT SYSTEM HYDRAULIC FAILURE. *S/D* LINE TO THE LEFT SIDE STRUT DOWNLOCK ACTUATOR WAS LEAKING. REPLACED LINE.SDR 98UAL900290Bearing · failedDIVERTED TO LAS DUE TO AN OIL INDICATION LIGHT ON THE RIGHT ENGINE. *S/D* METAL WAS FOUND IN THE MAIN OIL FILTER AND ON ALL CHIP DETECTORS. THIS WAS CAUSED BY A FAILED BUMPER BEARING. ENGINEERING HAS CREATED TASKS TO REPLACE THE BUMPER BEARINGS.
Back to Pratt & Whitney PW2037